Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5149-2
POLE AND EQUIPMENT SCHEDULE® o z 8 NO. STANDARDS VEH. SIGNAL KG. PED. SIG. P.P.B. POLE LOC. H.P.S.V. SHAFT MOUNTED REFLECTIVE STREET NAME SIGN (RSNS) COMMENTS TYPE HEIGHT SIGNAL M.A. LUMIN. M.A. MAST ARM P0_E MTG. 0 QUAD A B Luminare (N) Q 26-4-100 30' 45' 15' 2 -MAS SV -I -T SP -1 -CS 4 2 25 4' 250W Santa Ana Ave F=20' (N) © 1-A 10' - - - TV -I -T SP -1 -CS 6 3 22' 4' - - #10 (N) © 26-4-100 30' 40' _ 15' 2 -MAS SV -I -T SP -1 -CS 6 3 20' 4' 250W Citrus Ave F=15' (N) © 1-A 10' - - _ - TV -I -T _ SP -1 -CS 8 4 21' 4' - - 3 (N) © 26-4-100 30' 40' *15' 2 -MAS SV -I -T SP -1 -CS 8 4 24' 4' *250W Santa Ana Ave F= 16'; Straight Arm Luminare (N) Q 1-A 10' - - - TV -I -T SP -1 -CS 2 1 20' 4' - - (N) © 26-4-100 30' 45' 15' 2 -MAS SV -I -T SP -1 -CS 2 1 25' 4' 250W Citrus Ave F=18' (N) QH 1-A 10' - - - TV -I -T SP -1 -CS 4 2 20' 4' - 5 © EXACT POLE LOCATIONS DETERMINED BY FIELD ENGINEER; POTHOLE POLE FOUNDATIONS PRIOR TO ORDERING POLES. * INSTALL STRAIGHT MAST ARM 4 1 2 3 QUADRANT D ETAI L PEDESTRIAN/EQUESTRIAN PUSH BUTTON LOCATION (TOP VIEW) Sanaa Ana 1Ave 6000 CUrusAve 10800 Sana Ana16100Ave CilrusAve 10900 PROP. C/G PROP. S/W 01 AWG SIZE CABE TYPE 02 AAAAA/AI'\A\AWGSIZE 03 ::si 11 05 ) 06 -- -41 -- 07 1 d' PROPOSED PHASE DIAGRAM CUT S PROP. C/G °+ 2"C(1 DLC) a 0 a 2"C(1 DLC) PROP. C/G PROP. S/W 2"C(4 DLC) / • PROP. BERM \z-IPROP. BERM OVERHEAD WIRES CONIDUCTOR SCHEDULE AWG SIZE CABE TYPE POLE OR CIRCUIT AAAAA/AI'\A\AWGSIZE CIRCUIT 00000/6\onn 2' 3' 3' 3' 2' 3' 3' 2-4 2-4' #8 GROUND 1 1 1 1 1 1 1 2 2 12 ONDUCTOR 3 CONDUCTOR POLE - A —/- 1 11 1 #10 LUMINAIRES 2 2 2 2 - 2 2 2 - B 11�11 DLC i�E'B') 01 - - - - 3 3 3 3 3 C 11�1�1�11 02 - - - 3 - - - 3 3 D - - - - 1�11�1�1�11 03 - 3 3 3 - - - 3 3 E 111111-_- -_1�1 1 04 - - - - - - 5 5 5 F -_1�1�1�-_- -_1�1� 05 - - - 3 - - - 3 3 G 1 11------1 1 1 06 - - - - 3 3 3 3 3 H 1 1 07 - - - - - _ 3 3 3 TOTAL 1 1 2 3 3 4 1 2> 2 3 3 8 8 8 08 - 5 5 5- - 5 5 NOTE: ALL CONDUIT AND CABLES ARE NEW ci ei TOTAL - 8 8 14 6 6 14 28 28 EVP CABLE 1 1 2 2- 1 1 4 4 CCN CABLE - - - - - - - 1 1 R73-3(CA) CURB/BEIM FLOW UNE OR EDGE OF SHOULDER 0 0 0 B.C.R. ".• LA1 Ji.QI: FOR "A' AND "B' DIMENSIONS, SEE POLE SCHEDULE OR AS DIRECTED BY ENGINEER (TYPICAL SIGNAL POLE PLACEMENT, UNLESS SHOWN ON PLANS) SIGNAL STANDARD PLACEMENT [DIMENSIONS AND EQUIPMENT LOCATIONS AVE E 2"C(4 DLC) _ _ r 2"C(1 DLC) fl5T EX IRR. WATER(APPROX. LOCATION) BACK OF MIT UNE -00 Q R73-3(CA) +00 0 6 PACK CONDUIT WITH FIBER CAB FROM JIRUPA OVERHEAD WIRE. R73-3(CA cV R73-3(CA) STRAIGHT ARM LUMINAIRE P#4774818E TRAFFIC SIGNAL CONSTRUCTION NOTES ❑j INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCUDING TYPE "R" CABINET, LOOP DEFECTION, AND APPURTENANT EQUIPMENT. CONROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWVG 4001. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRAIIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CiY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. E FURNISH AND INSTALL SHAFT ARM MOUNTED REFLECTIVE STREET NAME SIGI PER CITY OF FONTANA STANDARD PLAN NO. 4005. p FURNISH AND INSTALL MAST ARM MOUNTED SIGN PER CALTRANS STANDARC PLAN ES -7N, DETAIL U. FURNISH AND INSTALL 3" PCV CONDUIT WITH PULL ROPE FOR SERVICE CONNECTION. CONTACT SOUTHERN CALIFORNIA EDISON PRIOR TO BEGINNIN( OF WORK (909-357-6116). 5T FURNISH AND INSTALL fl5T TRAFFIC BEARING PULLBOX. 6E FURNISH AND INSTALL j6E PULLBOX. [i]El FURNISH AND INSTALL fl6T TRAFFIC BEARING PULLBOX. Q7 COIL 50' OF 12 STRAND SMFO CABLE IN EX. P48 SPUCE VAULT. EJ FURNISH AND INSTALL 2"C, 21110 WIRES. (LUMINAIRES). El FURNISH AND INSTALL 2"C, 2116, 1i8, AND GROUND WIRE. (SERVICE). jJEl FURNISH AND INSTALL MAST ARM MOUNTED OPTICOM EVP DETECTOR AND DETECTOR CABLE. SEE DETAIL 'A'. ftij FURNISH AND INSTALL CCTV CAMERA PER MANUFACTURERS SPECIFICATIONS AND AS DIRECTED BY THE ENGINEER. Ei FURNISH AND INSTALL TYPE 116 PULL BOX. 13 FURNISH AND INSTALL 2* CONDUIT FOR 12 STRAND SMFO CABLE. 14 CITY TO PROVIDE FIBER OPTIC SPUCE ASSIGNMENT CHART FOR FIBER TERMINATIONS. EX. C/G EX. S/W ' 2"C(1 DLC) EX. 6 PACK CONDUIT WITH FIBER CABLE FROM JURUPA 2*C(4 DLC) EX. P48 SPUCE VAULT TRAFFIC SIGNAL GENERAL NOTES: SEE SHEET 1 OF 2. TYP. • TYP •%.o • 0 LIMIT LINE OR CROSSWALK BIKE LOOP PLACEMENT & SAWCUT DETAIL 'B' 1' TYP. Know what's below. 0111 before you dig. EX. BERM (IX / 2"C(4 DLC) 150W STREET UGHT EX. S/W 20C(1 DLC) OVERHEAD WIRES 2 VARIES 10' 12 46' 103 EX. E/P — c ±15' ;,d • 108 12' 17' 5 2"C(1 DLC) EX. C/G LX. S/W EX. C/G EX. DWY EMERGENCY VEHICLE PRE-EMPTION DETECTOR MAST ARM -FR"- EX. DWY EMERGENCY VEHICLE PRE-EMPTION DETECTOR MOUNTING DETAIL N.T.S DETAIL 'A' 2"C(1 DLC) ME -PROP. C/G 230' TO _ BACK OF XWALK in EX. S/W EX. C/G �P- SCALE: 1" = 20' 11111111113111 1111121111111 10 0 10 20 30 SERVICE ADDRESS 10916 CITRUS AVE. REV. REVISION DESCRIPTION DATE ENGR. an, DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. Prepared Under The Supervision Of : TJW ENGINEERING, INC. Traffic Engineering & Transportation Planning Consultants 540 N. Golden Circle Dr. Suite 104 Santa Ana, CA 92705 t: (949) 878-3509 f: (949) 878-3593 www.tjwengineering.com i THOMAS JOSEPH WHEAT R.C.E No. 69467 ,/(-7(1(q Exp. 8/70//16 CITY OF FONTANA, CALIFORNIA TRAFFIC SIGNAL PLAN CITRUS AVENUE ANA AVENUE ovizi DRAWN BY: KM DESIGNED BY: TJW CHECKED BY: TJW TY ENGINEER WALE: 1:20 DAZE: 12/12/2014 DRAWING NO.: 2 DA,�Z •� ly 5149 2 R.C.E.5115 R.C.E 51152 1,/17,/.2014 J• 46: 15 PAI a Nft 6