HomeMy WebLinkAbout5179-4FINISH GRADE (LAWN) VALVE BOX WATER. SERVICE LINE (if applicable) 2X4 REDWOOD BLOCK CONTINUOUS AROUND FINISH GRADE (0ROU D COVER) LIN. SIZE BRASS GATE VALVE PC MALE ADAPTOR T'; IRRIGATION MAIN PVC SCH u: UNION FOR 1 CUBIC FOOT PEA GRAVEL ILL GATE VALVE N.T.S. 10 WATERPROOF A.I.I. WIRE CONNECTIONS IONS AS PER STD. RED BLACK WHITE (COMMON) UF 14 WIRES BLUE FLOW SENSOR DIAMETER SAME SIZE AS FLOW METER SIZE MINIMUM DISTANCE UPSTREAM 1 OX DIAMETER OF FLOW METER SIZE MASTER CONTROL VALVE L. Y 'EE tf, MINIMUM DISTANCEJUWNSTREA M 5X DIAMETER OF FLIM METER SIZE FONTANA STANDARD #5010 MASTER VALVE / FLOW SENSOR N.T.S. 11 STEP STEP STEP STEP 4 • SLIP BASE SOCIET OVER END OF WIRES STRIP WIRES APROX. 5/8 FROM ENDS PUT CRIMP SLEWE OVER WIRE ENDS-CRIPP SLEEVE APPLY SEALER 1) INSIDE OF SEALING PLS FILL BASE SOCKT WITH SEALER PUSH SEALING FUG INTO BASE SOCKET UITIL IT LOCKS PUSH WIRES TO END OF BASE SOCKET TO ASSURE COMPLETE SEALING OF CONECTION RAINBIRD SNAP -ITE WIRE CONNECTOR 'OR EQUAL* FONTANA STANDARD #5013 WIRE CONNECTOR N.T.S. 12 PVC SCH 80 NIPPLE (TYPICAL, LENGTH AS REQUIRED) PVC SCH 40 ELL 30 -INCH LINEAR LENGTH OF WIRE, COILED WATER PROOF CONNECTION: RAIN BIRD SPLICE -1 (1 OF 2) VALVE BOX WITH COVER: RAIN BIRD VBWJMB ID TAG: RAIN BIRD VID SERIES TOP OF MULCH FINISH GRADE CONTROL ZONE: BRASS VALVE (USE BALL VALVE, 100 GB VALVE, AND QKCHK100 PRESSURE REGULATED BASKET FILTER) PVC LATERAL PVC SCH 40 MALE ADAPTER PVC SCH 80 UNION FOR SERVICING ASSEMBLY PVC SCH 80 NIPPLE, CLOSE PVC MAINLINE 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL BRICK (1 OF 4) PVC SCH 40 IEE OR ELL BRASS VALVE CONTROL ZONE N.T.S. 7 1/4 -INCH TUBING: POLYETHYLENE DISTRIBUTION TUBING RAIN BIRD XQ SINGLE -OUTLET EMITTER: RAIN BIRD XERI-BUG EMITTER XB- 10PC 1/4 -INCH BARB TRANSFER TEE: RAIN BIRD XBF3TEE 14 -INCH TUBING STAKE: RAIN BIRD TS -025 1/4 -INCH TUBING RUN FROM XERI-BIRD POLYETHYLENE DISTRIBUTION TUBING RAIN BIRD XQ EMITTER AROUND PLANT ON 1/4" TUBING N.T.S. 8 FIELD SATELLITE CONTROLLER: TORO ENTINEL U2-MPEA1 1 OAC-OB1-VRA* CbNCRETE PAD: -INCH MINIMUM THICKNESS 0 FINISH GRADE WIRES TO REMOTE CONTROL VALVES INCH PVC SCH 40 CONDUIT, FITTINGS AND SWEEP ELL 1 -INCH PVC SCH 40 CONDUIT, FI-TINGS AND SWEEP ELL TO POWER SUPPLY *PER CITY OF FONTANA REQUIREMENT AUTOMATIC CONTROLLER N.T.S. 9 CLEAN BACK AL SATURATE AND COMPACT TO 90% HARCAPING IATIVE BACKFILL 2" MINUS ION PRESSURE LATERAL LINE W/SLEEVE IRESSURE SUPPLY LINE W/SLEEVE :ONTROL WIRE SLEEVE SAND BACK FILL 2" 1��41`. ��IIIII�III! INSTALL CONTROL WIRE SLEEVE ADJACENT TO TH' PRESSURE SUPPLY LINE, SIZE PER SPEC. ALL SLEEVES TO BE SCH. 40 PVC AND TO BE a THE DIAMETER OF THE LINE TO BE SLEEVED. * INCREASE THIS DISTANCE TO 36" WHEN SLEEVJG UNDER ROADWAYS AND COMMERCIAL TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. SLEEVES SHALL BE EXTENDED BEYOND HARDSCA'E TO POINTS AS REQUESTED BY INSPECTOR IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND PROVIDE A VERTICAL MARK AT ENDS OF SLEEVIM VISIBLE AT GROUND LEVEL. FOVTANA STANDARD #5018 SLEEVING N.T.S. 4 PRESSURE REGULATOR IF REQUIRED. SET AS SHOWN ON SITE DRAWING STRAINER #40 MESH MODEL BRASS ELBOW BRASS BALL VALVE BRASS PIP` 18" i Vat"..4,1140, 41 11•WIirtit#f1 "� lr#Its •1Ilitlll BELIEF ORTIP as LOOSE KEY 184110 I ,'■,a„ I HOSE 61B ♦♦♦♦♦ LOCK BOX -;, j ice, 6 t 4 REBAR REDUCE PRESSURE BACKFLOW PREVENTER BRASS NIPPLE (4 PLACES) BRASS ELBOW BRASS UNION BRASS PIPE BRASS BALL VALVE PRESSURE CONC. STABILIZER SUPPLY LINE (TRUST BLOCK) (INTAKE) p. . FRONT 3/4" GRAVEL 12' PLA\ NOTE: BACKFLOW ENCLOSURE, "GUARDSHACK" SIZE TO FIT HINGED AT ONE END SECURE TO 6"X8" FOOTING W/4" J BOLTS (EQUIPMENT TO BE CENTERED INSIDE HOUSING) GENERAL NOTES if 'RESSURE ;UPP LY LINE DISCHARGE) 18' ...141,7fret:\ FOOTING/FOUNDATION Riv.Ya��y' END BACKFLOW ENCLOSURE (SEE NOTE BELOW) BRASS ELBOW BRASS UNION BRASS BALL VALVE #4 REBAR 1. CONTRACTOR SHALL FORM ENCLOSURE MD REQUEST INSPECTION PRIOR TO POURING FOOTING/FOUNDATIOI 2. USE 520-C-2500 CONCRETE FOVTANA STANDARD #5007 BACKFLOW PREVENTER N.T.S. 5 z FINISIED GRADE 6" MIN FROM HARDSCAPES _111X11=J11_ 11_=111E11 111 111=NON PRESSURE LATERAL LINE 6"MIN Ili III=III=I 111 -TI -111= PRESSURE SUPPLY LINE CONTROLL WIRES CLEAN BACKFILL 2" MINUS ` SAND FINE GRANULAR MATERIAL WILL BE LACED ON ALL LINES, NO LARGER THAN 1/2" INCH IN SIZE, HIS WILL BE PERMITTED IN THE INITIAL BACKFILL MEASURED 6" FRCA THE TOP OF PIPE. THE REMAINDER OF TRENCH CAN BE FILL WITH RO(< SCREENED 2" MINUS. ALL BACK FILL IS TO BE SATURATE AND COMPACTED TO 90; INSTALL ALL PVC PIPE WITH LABEL JP, SNAKE ALL PIPE IN TRENCH. BUNDLE AND TAPE ALL CONTROL W; ES AT 10' 0.C. TO PRESSURE SUPPLY LINE AND PROVIDE A SERVI:E LOOP AT ALL 90 DEGREE CHANGES IN DIRECTION. PRESSURE MAIN 2" AND LARGER STALL BE P.V.C. CLASS 315 SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40. CONTRACTOR SHALL PROVIDE SLEEV.S OR CONDUIT LINES WHEN MAINLINE INSTALLATION IS UNDER APHALT OR CONCRETE. CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE SERVING A DRINKING FOUNTAIN OR RESSURE MAINLINE 3" AND LARGER, FONTANA STANDARD #5015 TRENCHING N.T.S. 6 FINISH GRADE/TOP OF MULCH QUICK -COUPLING VALVE: RAIN BIRD MODEL 33DRC VALVE BOX WITH COVER: 10 --INCH SIZE WITH 2" LETTERS QV LOCK BOLT BRASS NIPPLE (LENGTH AS REQUIRED) 6 -INCH MINIMUM DEPTH OF WASHED PEA GRAVEL BRASS STREET ELL BRICK (1 OF 2) BRASS NIPPLE (LENGTH AS REQUIRED) BRASS ELL WITH BRASS THREADED NIPPLE PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE BRASS ELL #4 REBAR 24a' LONG W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT NOTE: SUPPORT SYSTEM 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE, QUICK -COUPLING VALVA N.T.S. 1 INSIDE VIEW OF XER1,721,Fla EMISSION DEVICES SAME AS XERI—BIRD AT GRADE NOTE: COIL ADDITIONAL 9 -INCHES OF TUBIMG IN VALVE BOX TO FACILITATE MAINTENIANCE, (7) RIEMOVABLE PORT PLUGS XBD-80 XERI-BIRD IN VALVE BOX 6 -INCH VALVE BOX RAIN BIRD VB-GRND MULTI.OUTLET EMISSION DEVICE RAIN BIRD XERI-BIRD XBD-80 TOP OF MULCH FINISH GRADE 1/4 -INCH TUBING: POLYETHYLENE DISTRIBUTION TUBING RAIN BIRD XQ PVC SCH 80 CLOSE NIPPLE PVC LATERAL PIPE PVC SCH 40 TEE OR ELL 3—INCH MNP DEPTH OF 3/4 -INCH WASHED GRAVEL XERI-BIRD MULTI -OUTLET EMISSION DEVICE N.T.S. PLAN VIEW TYP. CONCRETE TO REST AGAINST UNDISTURBED SOIL NOTE: THRUST BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH PIPE MANUFACTURER'S RECOMMENDATION FOR SIZE OF" PIPING REQUIRED. UTILIZED IN ALL (2 1/2" AND LARGER MAINLINE PIPE) #3 REBAR TO BE PLACED AROUND PIPE INITO THRUST BLOCK TYP. CIN OF FONTANA, CALIFORNIA Drawn By: LKD C.F.D. LANDSCAPE IMPROVEMENT PLANS for A T No. 18907 Designed By: R.J.P. Scale: 1 30' APPROVED: rim =;rrs ► m ikook-. -01/4017.2-41. 11 Date: 11/5/2013 Dwg. No. 5t -1q THRUST BLOCK ASSEM BLY N.T.S. 3 RICH AR D DoPf fAN1DMA1SSto1C1IrA%TIES Landscape Architecture 1585 S. 'D' Street, Suite 103 San Bernardino, CA 92408 phone: (909) 888-5568 fax: (909) 384-9854 e-mail: rpa.la@verizon.net www.richardpopeandassociates.com Richard Pope, Landscape Architect CA# 2664 Owner/Applicant: Frontier Enterprises 8300 Utica Avenue, Suite 300 Rancho Cucamonga, CA 91730 (909) 354-8000 C.7 •-• 0 u Sheet Description: Irrigation Details Date: November 5, 2013 RP$A Job No.: 13-19 Drawn by: LKD Revisions: S w �i h ��y outallllll nt0 ill e r . ,$ , 12' PLA\ NOTE: BACKFLOW ENCLOSURE, "GUARDSHACK" SIZE TO FIT HINGED AT ONE END SECURE TO 6"X8" FOOTING W/4" J BOLTS (EQUIPMENT TO BE CENTERED INSIDE HOUSING) GENERAL NOTES if 'RESSURE ;UPP LY LINE DISCHARGE) 18' ...141,7fret:\ FOOTING/FOUNDATION Riv.Ya��y' END BACKFLOW ENCLOSURE (SEE NOTE BELOW) BRASS ELBOW BRASS UNION BRASS BALL VALVE #4 REBAR 1. CONTRACTOR SHALL FORM ENCLOSURE MD REQUEST INSPECTION PRIOR TO POURING FOOTING/FOUNDATIOI 2. USE 520-C-2500 CONCRETE FOVTANA STANDARD #5007 BACKFLOW PREVENTER N.T.S. 5 z FINISIED GRADE 6" MIN FROM HARDSCAPES _111X11=J11_ 11_=111E11 111 111=NON PRESSURE LATERAL LINE 6"MIN Ili III=III=I 111 -TI -111= PRESSURE SUPPLY LINE CONTROLL WIRES CLEAN BACKFILL 2" MINUS ` SAND FINE GRANULAR MATERIAL WILL BE LACED ON ALL LINES, NO LARGER THAN 1/2" INCH IN SIZE, HIS WILL BE PERMITTED IN THE INITIAL BACKFILL MEASURED 6" FRCA THE TOP OF PIPE. THE REMAINDER OF TRENCH CAN BE FILL WITH RO(< SCREENED 2" MINUS. ALL BACK FILL IS TO BE SATURATE AND COMPACTED TO 90; INSTALL ALL PVC PIPE WITH LABEL JP, SNAKE ALL PIPE IN TRENCH. BUNDLE AND TAPE ALL CONTROL W; ES AT 10' 0.C. TO PRESSURE SUPPLY LINE AND PROVIDE A SERVI:E LOOP AT ALL 90 DEGREE CHANGES IN DIRECTION. PRESSURE MAIN 2" AND LARGER STALL BE P.V.C. CLASS 315 SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40. CONTRACTOR SHALL PROVIDE SLEEV.S OR CONDUIT LINES WHEN MAINLINE INSTALLATION IS UNDER APHALT OR CONCRETE. CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE SERVING A DRINKING FOUNTAIN OR RESSURE MAINLINE 3" AND LARGER, FONTANA STANDARD #5015 TRENCHING N.T.S. 6 FINISH GRADE/TOP OF MULCH QUICK -COUPLING VALVE: RAIN BIRD MODEL 33DRC VALVE BOX WITH COVER: 10 --INCH SIZE WITH 2" LETTERS QV LOCK BOLT BRASS NIPPLE (LENGTH AS REQUIRED) 6 -INCH MINIMUM DEPTH OF WASHED PEA GRAVEL BRASS STREET ELL BRICK (1 OF 2) BRASS NIPPLE (LENGTH AS REQUIRED) BRASS ELL WITH BRASS THREADED NIPPLE PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE BRASS ELL #4 REBAR 24a' LONG W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT NOTE: SUPPORT SYSTEM 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE, QUICK -COUPLING VALVA N.T.S. 1 INSIDE VIEW OF XER1,721,Fla EMISSION DEVICES SAME AS XERI—BIRD AT GRADE NOTE: COIL ADDITIONAL 9 -INCHES OF TUBIMG IN VALVE BOX TO FACILITATE MAINTENIANCE, (7) RIEMOVABLE PORT PLUGS XBD-80 XERI-BIRD IN VALVE BOX 6 -INCH VALVE BOX RAIN BIRD VB-GRND MULTI.OUTLET EMISSION DEVICE RAIN BIRD XERI-BIRD XBD-80 TOP OF MULCH FINISH GRADE 1/4 -INCH TUBING: POLYETHYLENE DISTRIBUTION TUBING RAIN BIRD XQ PVC SCH 80 CLOSE NIPPLE PVC LATERAL PIPE PVC SCH 40 TEE OR ELL 3—INCH MNP DEPTH OF 3/4 -INCH WASHED GRAVEL XERI-BIRD MULTI -OUTLET EMISSION DEVICE N.T.S. PLAN VIEW TYP. CONCRETE TO REST AGAINST UNDISTURBED SOIL NOTE: THRUST BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH PIPE MANUFACTURER'S RECOMMENDATION FOR SIZE OF" PIPING REQUIRED. UTILIZED IN ALL (2 1/2" AND LARGER MAINLINE PIPE) #3 REBAR TO BE PLACED AROUND PIPE INITO THRUST BLOCK TYP. CIN OF FONTANA, CALIFORNIA Drawn By: LKD C.F.D. LANDSCAPE IMPROVEMENT PLANS for A T No. 18907 Designed By: R.J.P. Scale: 1 30' APPROVED: rim =;rrs ► m ikook-. -01/4017.2-41. 11 Date: 11/5/2013 Dwg. No. 5t -1q THRUST BLOCK ASSEM BLY N.T.S. 3 RICH AR D DoPf fAN1DMA1SSto1C1IrA%TIES Landscape Architecture 1585 S. 'D' Street, Suite 103 San Bernardino, CA 92408 phone: (909) 888-5568 fax: (909) 384-9854 e-mail: rpa.la@verizon.net www.richardpopeandassociates.com Richard Pope, Landscape Architect CA# 2664 Owner/Applicant: Frontier Enterprises 8300 Utica Avenue, Suite 300 Rancho Cucamonga, CA 91730 (909) 354-8000 C.7 •-• 0 u Sheet Description: Irrigation Details Date: November 5, 2013 RP$A Job No.: 13-19 Drawn by: LKD Revisions: Sheet: ELK:34 Of: 7