Loading...
HomeMy WebLinkAbout5058-131 NEWSERVICEMP' ❑ W W W W W w .,. W W `✓ `' - - - - I \V Nil >>, o W_' MN<11 MP 9 1 -1 ac 3.5 B 1, 6 11 (E S.C.E PULLBOXZ i North 7 - I < PLAN NOTES: (E) SCE _ - POWER POLE O7 VERIFY RISER QUADRANT PRIOR TO RUGH—IN. O1 3/4"C. 2 #10 do 1 X10 E/G. ® PROVIDE SPLICE BLOCKS AND REQUIRI TO DOWNSIZE SITE O2 1'C. 2 #8 do 1 #10 E/G. CONDUCTORS PRIOR TO CONNECTION 0 CIRCUIT BREAKERS 30 1 "C.O. 92 1 "C.0, 10 ® 1 1/4-C. 4 #8 do 1# 10 E/G. \ VERIFY EXACT LOCATION W/ UTILITY CIMPANY PRIOR TO _ ROUGH—IN O5 CONTRACTOR SHALL OBTAIN SEPARATE PERMIT FOR STREET < 11 CONTRACTOR SHALL OBTAIN SEPARATE PERMIT FOR DRNEWAY CROSSING AND INCLUDE TRAFFIC CONTROL IN BID. i w CROSSING. COORDINATE DRIVEWAY CLGURE WITH OWNER AND INCLUDE TRAFFIC CONTROL IN BID. © 4"C.0. INSTALLED PER CITY OF S.C.E. I REQUIREMENTS TO PICK—UP POINT. VERIFY PRIOR TO 1 © ' 2C. 6 �8 do 1 X10 E/G. ROUGH—IN. I CONTRACTOR SHALL BE RESPONSIBLE FOR THE FOLLOWING I LLI • ITEMS AND SHALL INCLUDE ALL COST IN BID: 13 1-C. 4 #10 do 1 #10 E/G. —IDENTIFYING LOCAL UTILITY COMPANY SERVICE PLANNER z —SUBMITTAL OF PLANS TO UTILITY COMPANY J —INCORPORATION OF UTILITY COMPANY RED LINES ONTO PLANS ! _ —APPROVAL OF PLANS WITH UTILITY COMPANY U —ALL COORDINATION WITH UTILITY COMPANY I--- —COMPLETE INSTALLATION OF ALL REQUIRED CONDUIT AND PULLBOXES < j -1 2+CO 1 14+00 ENLARGED ELECTRICAL SITE PLAN SCALE 1 , 8w_, •_0- 1 IRRIGATION — - r 14/ \1/ -4/ —_� \4/ \1/ 1.11 CONTROLLER \1/ 14/ EIL� MP—, 1 91 L i Q F] a . - L_ 49 ___I 5 W 1 ! I No th i 34 34 _ 01 5 1 5 _ / � _ 1 1 ,�� 5-- O 13 � • 3 � 3 = — — — — — — —— — 5 — — — — — — — -- — — — • � � �` � 5 I, � - 1 3 3 5 3 W \ 1 z J 1T _ 34 2 1 1T 1 2 34 \ 2 1 - 1T 22 . � 1T I 1T 1S 2 14 1S 2 34 34 34 34 27 34 ENLARGED ELECTRICAL SITE PLAN1/8.a,._o. SCALE 21 Underground Service Alert w"TOUG1,100 Mv- ROM TA SHOULD CONSTRUCTION OF THE CITY OF FONTANA, CALIFORNIA SECTION 4216/4217 OF THE GOVERNMENT CODE REQUIRES A DIG ALERT IDENTIFICATION ESS a Engineering Inc. Electrical Engineering &Consulting ELECTRICAL IMPROVEMENTSREQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE ENLARGED ELECTRICAL SITE PLANS o NUMBER BE ISSUED BEFORE_ A PERMIT TO r NO. E 13883 �� , ' 8048 Palm Ave o � U ,N FOOTHILL BOULEVARD DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN' A DILIGENT wAvN BY, PMM FOOTHILL BOULEVARD MEDIAN IMPROVEMENTS �E, AS SHOWN EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UP.6/30A4 _ ,..1,_I Highland. Ca. V -4E SIERRA AVENUE TO MANNER, THE CITY ENGINEER MAY ELECTRICAL PLANS DESIGNED ears DATE, UNDERGROUND SERVICE ALERT- *, �4F 92346 909 864-0223 Fax 909 864-0280 MANGO AVENUE REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH JJC MARCH 2013 CHECKED BIYi BY, DATEi PROJECT N3j TOLL FREE 1-800-227-2600 Cp1.t rn CONDITIONS AND STANDARDS IN APPROVED 13 TWO WORKING DAYS BEFORE YOU DIG C jca.eng@jcaeng.com EFFECT. RAG �— — /O l /3 5058 14 REV. REVISION DESCRIPTION DATE ENGR. CITY DATE CITY ENGINEER R.C.E. No. 51152 1