HomeMy WebLinkAbout5166-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC
EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER,
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE
LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO
AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL
UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND
SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES
PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT POR11ON OF THE WORK UNTIL THE SPECIFIED
DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME
OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE
SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF
THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET
SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE
BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED
BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
BENCH MARK:
CITY OF FONTANA BENCHMARK NO. 289
NGVD29, ELEVATION=1032.22'
FOUND RAILROAD SPIKE IN POWER POLE, NE CORNER
CATAWBA AVENUE & SANTA ANA AVENUE
BASIS OF BEARING:
THE BEARINGS SHOWN HEREON ARE BASED ON
THE CENTERLINE OF CATAWBA AVENUE BEING
NORTH 00' 15' 00" EAST PER R.S.B. 79/56.
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
l .i00jTjv4p
ass jtj]� I : Eu J] ED j
ffl? I [oil I IS; "
I p -m.
IT
STREET CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
A. CONTRACTOR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
AFTER FINAL PAVING HAS BEEN INSTALLED.
CONSTRUCTION NOTES QUANTITIES
O
CONSTRUCT 8" CONCRETE CURB AND 18" PERVIOUS GUTTER PER DETAIL ON SHEET 2,
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
TOP OF PAVEMENT
TIC ......
SEE CITY OF FONTANA STD. NO. 1000 FOR NOTES.......................................................................................................
1225
LF
5O
CONSTRUCT 6' WIDE CONCRETE SIDEWALK PER CITY OF FONTANA STD. NO. 1006.................................................................
9674
SF
60
CONSTRUCT ACCESS RAMP PER CITY OF FONTANA STD. NO. 1003...................................................................................
1
EA
A/0
5"AG /5" C43
CONSTRUCTOVER 12" MIN 959 COMPACTED NATIVE SUBGRADE PER CITY OF FONTANA STD. NO. 400 ....................28762
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
SF
15
CONSTRUCT COMMERCIAL DRIVEWAY PER CITY OF FONTANA STD. NO. 1002.....................................................................
3
EA
17
CONSTRUCT CONCRETE CROSS GUTTER & SPANDREL PER CITY OF FONTANA STD. NO. 403, W=10', R=50' .................................
870
SF
20
CONSTRUCT 8" AC DIKE PER CITY OF FONTANA STD. NO. 1007................................................................. .....................
54
LF
3o
REMOVE EXISTING WATER METER BOX AND CAP SERVICE LATERAL PER FONTANA WATER COMPANY REQUIREMENTS ......................
1
EA
4s
CONSTRUCT DOUBLE PARKWAY DRAIN PER SPPWC STD. NO. 151-2, INLET TYPE Il, S=6' .......................................................
72
LF
so
SAWCUT AND REMOVE EXISTING AC PAVING.................................................................................................................11626
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
SF
61
SAWCUT AND REMOVE EXISTING PCC CURB & GUTTER....................................................................................................
640
LF
s2
SAWCUT AND REMOVE EXISTING PCC SIDEWALK............................................................................................................
4584
SF
s3
REMOVE EXISTING AC BERM....................................................................................................................................
130
LF
ss
REMOVE OR SALVAGE EXISTING TREE, LANDSCAPE AND IRRIGATION (COORDINATE WITH LANDSCAPE ARCHITECT) ..........................
-
-
s7
REMOVE EXISTING STREET LIGHT...............................................................................................................................
1
EA
76
REMOVE & SALVAGE EXISTING SIGN AND POST (SEE SHEET 4).......................................................................................
2
EA
73
REMOVE EXISTING FENCE.........................................................................................................................................
620
LF
s0
PROTECT IN PLACE (ITEM AS INDICATED ON PLAN).......................................................................................................
-
-
92
EXISTING OVERHEAD POWER LINES TO BE UNDERGROUNDED AND POLES REMOVED BY SCE ......................................................
4
EA
94
TIE -OUT AND RESET EXISTING SURVEY MONUMENT........................................................................................................
3
EA
8
COLD PLANE EXISTING AC MINIMUM 0.15' DEPTH & AC OVERLAY TO MATCH EXISTING..........................................................
26502
SF
* THE PAVEMENT SECTIONS AND COMPACTION REQUIREMENTS ARE PRELIMINARY. FINAL SECTIONS
AND COMPACTION REQUIREMENTS WILL BE AS DIRECTED BY THE SOILS ENGINEER AT THE
COMPLETION OF THE ROUGH GRADING OPERATION AND UPON COMPLETION OF R -VALUE TESTS.
UNAUTHORIZED CHANGES AND USES
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR,
UTILITY PROVIDERS
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
TOP OF PAVEMENT
TIC ......
SEWER
NOTESm
CITY OF FONTANA
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE
8353 SIERRA AVENUE
CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST OF
FONTANA, CA 92335
THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE
(909) 350-6632
CITY ENGINEER FOR REVIEW.
CURB FACE
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
GAS
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
SOUTHERN CALIFORNIA GAS CO.
COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF
SAN DIMAS CA 91773
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT
(800)427-2000
SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CATCH BASIN
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN
ROOF DRAIN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
WATER
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
EDGE OF PAVEMENT
NEGLIGENCE OF DESIGN PROFESSIONAL.
FONTANA WATER COMPANY
SMH .....
15966 ARROW ROUTE
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
FONTANA, CA 92335
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
(909) 822-2201
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
CENTERLINE
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
DRIVEWAY
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
TELEPHONE
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
AT&T
TC.....
LYDIA CANDIA
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO
3939 E CORONADO STREET
THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE
ANAHEIM, CA 92807
PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS
714-237-6155
SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS OF THE U.S.
FINISHED SURFACE
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
ELECTRIC
RELATIONS CONSTRUCTION SAFETY ORDERS".
TOP OF GRATE
INV ....
SOUTHERN CALIFORNIA EDISON
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS' AND
PABLO IBARRA
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS"
7951 REDWOOD AVENUE
OF THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF
FONTANA, CA 92336
INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS".
909-357-6203
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
CABLE - TV
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
TIME WARNER
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY
EDDIE WALKER
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS
m
PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR
ENGINEER.
NO.
I REVISION DESCRIPTION
DATE
I ENGR.
I CITY
I DATE
SANTA
ANA
SHOULD CONSTRUCTION OF THE i Q .FESS/pN,\
REQUIRED IMPROVEMENTS NOT p q� 11
COMMENCE WITHIN TWO YEARS /`c�,, J� 6%
OF THE DATE OF APPROVAL Iw 4�NO. 333669 m
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER, EXPIRATION ;
THE CITY ENGINEER MAY REQUIRE ��*'• 6-30-2016
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE 9l��
WITH STANDARDS IN EFFECT. \0,
R� - GO/�D I�R,QI,V/NGS .�/5//� �'l•/�i�+. - K l � 511b
ABBREVIATIONS
VC ......
VERTICAL CURVE
TP ......
TOP OF PAVEMENT
TIC ......
TOP OF CURB
EL .......
ELEVATION
FL .......
FLOWLINE
FG ......
FINISH GRADE
FS ......
FINISH SURFACE
CF ......
CURB FACE
GB ......
GRADE BREAK
HP ......
HIGH POINT
INV......
INVERT ELEVATION
TG ......
TOP OF GRATE
CB ......
CATCH BASIN
RD ......
ROOF DRAIN
LD .......
LOCAL DEPRESSION
EP.......
EDGE OF PAVEMENT
COTG ....
CLEANOUT TOP OF GRATE
SMH .....
SEWER MANHOLE
R ........
RIDGE LINE
P.I.P.....
PROTECT IN PLACE
CL .......
CENTERLINE
DWY.....
DRIVEWAY
C&G.....
CURB AND GUTTER
TB.....
TOP OF BERM
TC.....
TOP OF CURB
TW.....
TOP OF WALL
FL.....
FLOWLINE
EP.
EDGE OF PAVEMENT
FS.....
FINISHED SURFACE
EG
EXISTING GROUND
TG.....
TOP OF GRATE
INV ....
INVERT
GB.....
GRADE BREAK
R .....
RIDGE LINE
CB.....
CATCH BASIN
PP. _ ...
POWER POLE
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED. IN
PART, ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
BEEN
WHICH ERRORS OR OMISSIONS
INCORPORATED INTO TTH SE DOCUMENTS
HAVE B
HAVE
AS A RESULT THEREOF.
LEGEND
i
I
I
I
1
I
I
I
I
I
I
DESCRIPTION
1
TITLE SHEET
2
-
I
STREET IMPROVEMENT PLANS AND PROFILE
PROJECT
LIMITS
T
SLOVER AVENUE
w
w
�
w
ZD
w
z
w
z
w
>
w
z
W
z
Q
Q
>
a
Q
Q
J
In
Q
w
W
U
U
m
SANTA
ANA
AVENUE
ROSE
AVENUE
JURUPA
AVENUE
VICINITY MAP
NOT TO SCALE
■i
SHEET 4
-------
-_-_-_-_ SANTA _AI1IA_AYE�III�_-_-_-
--- - ------ - ------------
I I I I I
I 1 I I 1
_ =
-
-
i
I
I
I
1
I
I
I
I
I
I
DESCRIPTION
1
TITLE SHEET
2
-
I
STREET IMPROVEMENT PLANS AND PROFILE
I
f1
1
I I
I I
1 I
II I I
I I I
i
I I
I I
I I
I I
I
I I
I I
I I
I I
SHEET INDEX MAP
SCALE: 1"=200'
SHEET INDEX
SHEET NO.
DESCRIPTION
1
TITLE SHEET
2
CROSS SECTION AND DETAILS
3-4
STREET IMPROVEMENT PLANS AND PROFILE
LEGEND
CENTERLINE
RIGHT OF WAY
LOT LINE
EASEMENT
EXISTING SEWER
EXISTING WATER
EXISTING ELECTRICAL
EXISTING GAS
LIMITED USE AREA
CITY OF FONTANA, CALIFORNIA
Huitt-Zollars, Inc. Ontario DRAWN BY: P.M. NO. 19527 - OAKMONT SANTA ANA WAREHOUSE SCALE:
3990 CONCOURS, SUITE 330 * ONTARIO, CALIFORNIA 91764 * (909) 941-7799 MAY M P AR AVENUE & SANTA ANA AVENUE AS SHOWN
DESIGNED BY: DATE:
APPROVED BY MAURICE H. MURAL)R.C.E. EXPIRES DATE DLw TI L SHEET -CON TION NOTES 8c QUANTITY ESTIMATE
CHECKED BY: APPROV Y: DWG. NO.: 1
u 33366 6-30-16 /Orem M.H.M. 5166
CITY NGINEER R.C.E. 51152 DATE: