Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5128-2
POLE AND EQUIPMENT SCHEDULE C) E-= C) NO. STANDARDS •R• CABINET, VEH. SIGNAL MTG. PED. SIG. P.P.B. CONTRACTOR POLE LOC. H.P.S.V. SHAFT MOUNTED REFLECTIVE STREET NAME SIGN (RSNS)* COMMENTS TYPE HEIGHT SIGNAL M.A. LUMIN. M A. MAST ARM POLE MTG. 0 QUAD A B Luminare (N) QA 29-5-100 30' 55' 15' 3—MAS SV— 1—T SP-1—CS 2 4 1 20' 4' 250W Sultana Ave. F=18.5' (N)1@1 2 1—A 10' —I — — I TV -2—T SP-1—CS 4 1 20' 4' — — — (N) © 19-4-100 30' 30' 15' MAS SV— 1—T — 4 1 20.5' 9' 250W Foothill Blvd. — (N) QD 15TS 30' — 15' — SV-2—TA SP-1—CS — — 15.5' 8' 250W — — (N) QE 61-5-100 30' 60' 15' 3—MAS SV— 1—T SP-1—CS — — 9' 4' 250W Sultana Ave. F=15' (N)QF - 1—A 10' — — — TV -2—T — 8 3 9' 4' — — — (N) © 19-4-100 30' 25' 15' MAS SV— 1—T SP-1—CS 8 3 10' 4' 250W Foothill Blvd. — (N) 0 15TS 30' — 15' — SV-2—TA SP-1—CS 2 4 14' 4' 250W 3 — ■ EXACT POLE LOCATIONS DETERMINED BY FIELD ENGINEER; POTHOLE POLE FOUNDATIONS PRIOR TO ORDERING POLES. EMERGENCY VEHICLE PRE-EMPTION DETECTOR-\ MAST EMERGENCY VEHICLE PRE—EMPTION DETECTOR MOUNTING DETAIL N.T.S DETAIL 'A' E/P 285' TO _ N BACK OF uMff UNE - -- N N 104 FF N O #5 o�lRfW - — PROP. C/G 2'C: 1 DLC TRAFFIC SIGNAL CONSTRUCTION NOTES: Ffl INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE 03 •R• CABINET, LOOP DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET 1A3 AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4001. � CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT � REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. 0 FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF l2 FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. ❑3 INSTALL CITY FURNISHED OPTICOM EVP DETECTOR AND DETECTOR CABLE. SEE DETAIL 'A' ® FURNISH AND INSTALL MASTARM MOUNTED SIGN PER CALTRANS STANDARD PLAN ES -7N, 06 DETAIL U. 07 08 FURNISH AND INSTALL 3• PVC CONDUIT WITH QUARTER INCH (1/4-) POLY PULL ROPE 2-4' PER SCE REQUIREMENTS. COORDINATE SERVICE WITH EDISON PLANNING AT #8 909-357-6116. PROPOSED PHASE 6E FURNISH AND INSTALL #6E PULLBOX. F7 FURNISH AND INSTALL POLE MOUNTED SIGNS. *CONTRACTOR FURNISHED R.S.N.S. TO BE INSTALLED ON A SHAFT EX. E/P MOUNTED MAST ARM SUPPLIED BY THE CONTRACTOR. 1 2•C: 1 FOOTHILL rnvr. v/v - 2 C: 4 DLC 2•C: 1 DLC PROP. C/G 102 SCHEDULE 03 0-----------4 � 1A3 � A � � , g� AWG SIZE CIRCUIT z l2 z3 A4 A5 z i zi z 3• 06 4' 07 08 4' 4' 2-4' 2-4' #8 GROUND PROPOSED PHASE DIAGRAM 1 1 106 37' IIx EX. E/P 8 FURNISH AND INSTALL 2"C, 2#10 WIRES. (LUMINAIRES) F9 FURNISH AND INSTALL 2•C, 2#6, 1#8, AND GROUND WIRE. (SERVICE) �2OB TRAFFIC SIGNAL GENERAL NOTES: a DUE TO THE CURB s 2•C: 1 DLC RAMP DESIGN,V�l 24 SEE SHEET 1 OF 2. ME CONTRACTOR TO FIELD Know what's below. Call before you dig. CONDUCTOR SCHEDULE AWG SIZE OR CABLE TYPE POLE OR CIRCUIT � 1A3 � A � � � g� AWG SIZE CIRCUIT z l2 z3 A4 A5 z � zi z 3• 4' 4' 4' Y 4' 4' 2-4' 2-4' #8 GROUND 1 1 1 1 1 1 1 2 2 12 CONDO= AOR POLE - A B -_ - _ - --- - - - - -1 - 1 1 1 1 #10 LUMINAIRES 2 2 2 2 2 2 2 2 - 1 1 1 1 1 (TYDPECB') 02 03 - - - - - - - 3 - - - - 3 - 3 3 3 3 4 3 _ C ---------- 1 1 1 1 1 1 1 1 ID -_-_-_-_1_1_1_1_1_ 04 - - - - 4 4 4 4 E 1 _ 1 _ 1 _ 1 _ - _ - _ - _ 1 _ 1 _ 06 - 3 3 3 - - - 3 IF -1 1 1 11 1-- -1 1 1 1 07 08 - - - - 3 3 3 3 3 G H -_-_1111-_-_-_1111 - - -_ 1 1 - _ - _ - _ 1 1 1 1 - - - 4 - - - 4 4 TOTAL - 3 3 10 7 7 10 20 20 TOTAL 1_ 2 1 3 2 4 3 1- 2 1 3 2 8 g [,8Z61 EVP CABLE 1 1 2 2 1- 1 1 4 4 CONDUIT FILL 11 11 r15 24 14 13 19 23 23 NOTE: ALL CONDUIT AND CABLES ARE NEW Sultana Ave8100 PROP. C/G 2•C: 4 DLC C Foothill 15300 ULEVARD rmvr. zo/ w PROP. C/G F_ 2•C: 1 DLC C3 Li •A' CURB/BERM FLOW UNE OR EDGE OF SHOULDER •I B.C.R. - t - - - - O I 'Ba r &M- FOR 'A• AND 'e' DIMENSIONS, SEE POLE SCHEDULE OR AS DIRECTED BY ENGINEER (TYPICAL SIGNAL POLE PLACEMENT, UNLESS SHOWN ON PIANS) SIGNAL STANDARD PLACEMENT DIMENSIONS AND EQUIPMENT LOCATIONS 2•C: 1 DLC PROP. C G ---0l5 106 20+001 PROP. S/W PROP. C/G S' �••, \x.5.7 LOCATE POLE TO - v MAINTAIN 4' WALKING � � m � 2 y W/ 5' OF THE CROSSWALK. 62' PATH AND BE WITHIN 2'C: 1 DLC SCALE: 1 " = 20' 1INTO LIMIT LINE OR BACK OF CROSSWALK PROP. C/G BIKE LOOP PLACEMENT & SAWCUT 10 0 10 20 30 PROP. C/G PROP. S/W ko DETAIL 'B' 102 PROP. S/W 7 C-DPHASES 4 AND 8 WILL BE PLACED ON VEHICLE RECALL c=v1f1C- ennoE-cc 1 9i41 1 Fl1nTHll I RI VIS