Loading...
HomeMy WebLinkAbout5150-6lo1/2"IN .TURF AREAS, 12 2" IN SHRUB MV10 BACKFLOW PREVENTER -� 9 %J 2 8 ____,jo� e- r all P1114H G R 0 U P 6 3 LANDSCAPE ARCHITECTURE 12 3 8 1=1 I IEHI I 11=1 I 1=1 I I- I 1= 5 I'll- 12 5 4 -4T- 4649 Brockton Ave. 11 4 0 6 18'* -24" 2 Q ji Riverside, CA 92506 ;4 d 36" CONCRETE 1 11 Phone: (951) 369-0700 I I I F ACCESS PAD 1 1 12*x12"x12" MINIMUM CONCRETE THRUST BLOCK 0- 0� 9 0 2. TO 'POINT OF CONNECTION' - ADAPT AS NECESSARY 10 Fax: (951) 369-4039 3. BRASS 90 DEGREE ELL - TxT 4. PVC SCH 40 MALE ADAPTER - SIZE AS REQUIRED 11 WWW.comworksdg.com HF I I -El 11-1 5. PVC MAINLINE PER LEGEND - SIZE PER PLAN 6. FINISH GRADE 7 8 14 10o 7. BRASS NIPPLE - TxT - LENGTH AS REQUIRED 15 12 1. ELECTRIC CONTROL VALVE PER LEGEND 13 1. CONTROLLER ENCLOSURE PER LEGEND AND/OR NOTES S. BRASS UNION SIZE AS REQUIRED -DOWN LID AND SS 80 9. BRASS NIPPLE TxT - 4" MINIMUM LENGTH 2. RECTANGULAR PLASTIC VALVE BOX WITH BOLT 2. AUTOMATIC CONTROLLER PER LEGEND H Ill LT 3. FINISH GRADE 10. BRASS NIPPLE TXT - 2- MINIMUM LENGTH (TYP. OF 2) 3. HEAT BRAND "MV" ON LID IN 2" HIGH CHARACTERS 11. BRASS Y -STRAINER - 60 MESH SCREEN W/ HOSE BIB 4. FINISH GRADE 4. DIRECT BURIAL CONTROL WIRES TO VALVES 12. VANDAL RESISTANT ENCLOSURE - MODEL PER LEGEND 5. PVC SCH 40 MALE ADAPTER 5. 3" PVC SWEEP ELL - EXTEND BEYOND EDGE OF BASE INSTALL PER MANUFACTURERS REQUIREMENTS 6. 'QUICKPAD' ENCLOSURE MOUNTING PAD PER MFG'S SPECS 1. METERED CONTROLLER ENCLOSURE PER LEGEND 13. INSTALL 4" CONCRETE PAD, EXTEND 6" PAST ENCLOSURE 6. WATERPROOF WIRE CONNECTION W/36" EXPANSION LOOP 7. SLOPE EDGE OF BASE 1% TO DRAIN AWAY FROM ENCLOSURE 2. ELECTRICAL METER SOCKET WITH TEST BLOCKS 12" MINIMUM, 30" MAXIMUM 7. #14 OF WIRES TO CONTROLLER MASTER VALVE OUTPUT 8. 120V AC POWER IN CONDUIT 3. LOAD CENTER 8. 3/4- CRUSHED ROCK - 6" DEEP 9. 120V ON-OFF SWITCH WITH CONVENIENCE OUTLET 4. DIRECT BURIAL CONTROL WIRES TO VALVES NOTES: 9. COMMON BRICK - 4 REQUIRED 10. TERMINAL STRIPS FOR CONTROL WIRES 5. 3" PVC SWEEP ELL - EXTEND BEYOND EDGE OF BASE INSTALL BACKFLOW PREVENTER PER LOCAL CODES, HEALTH DEPARTMENT STANDARDS, AND 10. PVC MAINLINE PER LEGEND - LENGTH AS REQUIRED 6. QUICKPAD ENCLOSURE MOUNTING PAD PER MANUFACTURE MANUFACTURER'S DIRECTIONS. VERIFY LOCAL REQUIREMENTS PRIOR TO INSTALLATION. 11. PVC SCH 40 ELL - SxS 11. 5/8" x 5' MIN. LENGTH COPPER GROUNDING ROD 7. CONDUIT FOR LINE FEED INTO METER WHERE BACKFLOW DEVICE SIZE IS SMALLER THAN MAINLINE, ENTIRE APPARATUS TO BE SIZE 12. MAINLINE PIPING FROM POINT OF CONNECTION 12. EXTEND EDGE OF BASE 6" BEYOND EDGE OF ENCLOSURE 8. FINISH GRADE OF MAINLINE. BUSH DOWN ONLY AT THE BACKFLOW DEVICE. FINAL LOCATION OF DEVICE 13. MAINLINE PIPING TO CONTROL VALVES 13. GROUND CONTROLLER PER MANUFACTURER TO BE DETERMINED IN THE FIELD. BACKFLOW TO BE LOCATED IN PLANTER AREA AND 14. PVC UNION - SIZE AS REQUIRED EXTEND 4" ABOVE TOP OF BASE 9. IRRIGATION CONTROLLER IN ENCLOSURE PER LEGEND " SCREENED WITH SHRUBS AS POSSIBLE. Ij6QUE ME gF gaE 15. FILTER FABRIC A Controe r Meterenc osu re-ackflow Preventer Dill Master Valve 1/2" IN TURF AREAS 2 NOTES: 2" IN SHRUB AREAS ............ /- TEE OFF MAINLINE TO BE 2 NORTHWOODS NOTE: 12IN TURF AREAS SAME SIZE AS LATERAL 3 USE TEFLON TAPE ON 5 2" IN SHRUB AREAS- LINE EXITING VALVE. A - 1 _401 T R 17165 FSALL MALE PIPE THREADS. QCV ONLY REDUCE PIPE AT 3 THE VALVE. SIZE BOX FOR CONTROL VALVE AND LMD 3 61'-12 13 BALL VALVE TO FIT WITH ADEQUATE OPERATION OF 10 BALL VALVE HANDLE. LENNAR HOMES 2 391 N. MAIN ST I , I _ = !- I } 5 I 1i=1 I F 6" SUITE 300 18» -24f1 12' 4 5 15 CORONA, CA 92880 18" MIN. 6 it 10 14 1 F0 18"-24 7 15 18'9-24" 4 JOB NUMBER: 131244 8 FLOW 16 DRAWN BY: KCK 9 914 0 0 2 it 8 CHECKED BY: SJR 0- 12 0 0 Q01-1 d-lu 2" 8 7 DATE: 9/4/14 0 4 12 11 4 6 13 4 1 1 0 vojc��O'c V ou ra ­ �uo ), e% 00 1. ELECTRIC CONTROL VALVE PE EGEND 0 Rpc 44 10 0 O_ 9. PVC LATERAL LINE PER LEGEND REVISIONS: MIN. UPSTREAM LENGTH OF MIN. DOWNSTREAM LENGTH OF 12 V 2. 'JUMBO' PLASTIC VALVE BOX WITH BOLT DOWN LID AND SS BOLT - HEAT 10. PVC SCH 40 ELL - SxS STRAIGHT PIPE - 1 Ox PIPE DIA. STRAIGHT PIPE = 5x PIPE DA 1. 10" ROUND PLASTIC VALVE BOX 8. PVC SCH 40 ELL TxT 11. PVC MAINLINE PER LEGEND 7/8 CITY 1ST PLAN 1. RECTANGULAR PLASTIC VALVE BOX WITH 9. VALVE BOX EXTENSION(S) AS REQUIRED WITH LOCKING LID AND SS BOLT 9. SCH 40 PVC MAINLINE FITTING BRAND STATION NUMBER 1. 10" ROUND PLASTIC VALVE E30X 8. PVC MAINLINE TO SYSTEM - BOLT -DOWN LID AND - SS BOLT 10. FILTER FABRIC 10. PVC SCH 40 MAINLINE PIPING PER ON LID IN 2" HIGH CHARACTERS 12. SCH 40 PVC MAINLINE FITTING CHECK CORRECTIONS WITH LOCKING LID AND SS BOLT PER LEGEND 2. HEAT BRAND "BV" ON LID IN 2" HIGH 2. HEAT BRAND "QCV" ON LID IN 2" 3. FINISH GRADE 13. '3/4" GRAVEL - 6" DEEP 7/8 FIRE PROTECTION HIGH CHARACTERS EQUIPMENT LEGEND 2. HEAT BRAND "FS" ON LID IN 9. VALVE BOX EXTENSIONS AS REQUIRED CHARACTERS 11. WALK, CURB, OR WALL, ETC. 4. PVC SCH 40 MALE ADAPTER - SIZE AS 14. 'CHRISTY'S' I.D. TAG OR EQUAL I MODIFICATIONS NOTE: 3. FINISH GRADE REQUIRED - TYP. OF 2 15. BALL VALVE PER EQUIPMENT LEGEND 12 CITY 2ND PLAN 2" HIGH CHARACTERS 10. WATERPROOF WIRE CONNECTORS WITH 3. FINISH GRADE USE TEFLON TAPE ON ALL MALE PIPE THREADS. 4. 3/4- CRUSHED ROCK 4- DEEP 12. #4 REBAR, 18" MINIMUM LENGTH 5. WATERPROOF WIRE CONNECTOR WITH 36" SAME SIZE AS CONTROL VALVE 8/ 3. FINISH GRADE 36" EXPANSION LOOP 4. 3/4" CRUSHED ROCK - 4" DEPTH 5. QUICK COUPLER PER LEGEND SUPPORT STAKE COILED EXPANSION LOOP 16. PVC UNION - SIZE AS REQUIRED CHECK CORRECTIONS 4. 3/4- CRUSHED ROCK - 4- DEEP 11. CABLE TO TRANSMITTER/CONTROLLER 5. BALL VALVE PER IRRIGATION PLAN 1/2- IN TURF AREAS AND 6. PVC SCH 80 NIPPLE LENGTH AS 13. STAINLESS STEEL CLAMP - 2 REQ. 6. WIRES FROM CONTROLLER 17. FILTER FABRIC 9/4 CITY 3RD PLAN 5. FLOW SENSOR PER LEGEND PER MANUFACTURER 6. COMMON BRICK - 4 REQUIRED 2" IN SHRUB AREAS REQUIRED 14. COMMON BRICK 3 REQUIRED 7, COMMON WIRE TO OTHER VALVES ON 4 CHECK CORRECTIONS 6. COMMON BRICK - 4 REQUIRED 12. FILTER FABRIC 7. SCH 40 PVC MALE ADAPTER - 2 REQUIRED 7. PVC SCH 40 STREET ELL TxT 15. FILTER FABRIC SAME CONTROLLER 7. PVC MAINLINE FROM POC PER LEGEND 8. MAINLINE PIPING PER IRRIGATION PLAN 8- - :1 REQUIREQ 1/2- IN TURF, 2- IN PLANTER W apiCK E owSensor- F_ B -all --Valve---- _G Quick ---Cour) el -r Vavel,,,,--- --Remote Control Valve V%A L 0 ANPF NOTES: 8 % N ,TEE OFF A I I=i I I=i N N 6 MAINLINE TOBE3 1 -ew 711 1-01- J W SAME SIZE AS II ISI F10/31/15 LATERAL LINE 2 8 (In Renewal Date o^ EXITING VALVE. ARV ONLY REDUCE LLUL 9 of Dot 12 0 PIPE SIZE AT IJj I :III VALVE. JUMBO 7 10 1 9 12' C N\_ VALVE BOX TO 3 BE USED TO FIT 5 8 V) 3 ALL EQUIPMENT WITH EASY 24 .......... ........ ... ;--- �-JE ACCESS TO . ..... 00 00 BALL VALVE AND ISI IRRIGATION FILTER FOR 0DOO op(g r_N 4 .4 :00 CLEANING. 0 8 00 Ct__ DETAILS 10 17 12 12 16 19 16 13 11 SCALE: AS NOTED 0 0 0 0 10 0 0 0 )�� ) <� 7 1 Ilk - If!_Iii 00 00 00, )01, U 1. FINISH GRADE/TOP OF MULCH 9. PVC SCH 40 FEMALE ADAPTOR 0 %00j ou ou 0 00 0 0 0 0 0 0 1 . MULCH PER PLAN 2. JUMBO PLASTIC VALVE BOX WITH BOLT DOWN 10. LATERAL PIPE PER PLAN 9 2. RAINBIRD SEB 7XB EMITTER BOX 6 0 LID AND SS BOLT - HEAT BRAND STATION 11. PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 3. FLUSH CAP 1. FINISH GRADE NUMBER ON LID IN 2" HIGH CHARACTERS 12. PVC SCH 40 ELL 4. EASY FIT COUPLING 0 1/2" BLANK POLYETHYLENE TUBING NOTE: 5. 2. CLEAN BACKFILL 909 COMPACTION REQUIRED 1SEE SPECS - 3. 36 -INCH LINEAR LENGTH OF WIRE, COILED 13. PVC SCH 80 NIPPLE (2 -INCH LENGTH, HIDDEN) 3. NON -PRESSURE LATERAL LINE PER LEGEND 4. WATERPROOF WIRE CONNECTION AND PVC SCH 40 ELL . RAINBIRD SEB-7XB PLASTIC EMITTER BOX 6. FINISH GRADE ALLOW 6" MINIMUM 4. PRESSURE SUPPLY UNE PER LEGEND 2. AIR RELIEF PER IRRIGATION LEGEND 7. PVC EXHAUST HEADER OF DRIPLINE 5. 1 -INCH BALL VALVE (INCLUDED IN 14. PVC SCH 40 TEE OR ELL 3. FINISH GRADE 8. SCH. 40 PVC TEE OR EL 5. CONTROL WIRES - INSTALL BELOW PRESSURE SUPPLY LINE XCZ-PRB-100-COM KIT) 15. MAINLINE PIPE 8. PVC TEE CONNECTED TO PVC HEADER 9. BARB X MALE FITTING TUBING IN VALVE 6. PROVIDE 2" OF CLEAN BACKFILL BELOW PRESSURE MAINLINE 6. 'CHRISTYS' I.D. TAG 16. 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED 4. X" X -Y4" PVC REDUCER BUSHING PIPE 10. DRIPLINE PER IRRIGATION LEGEND BOX Know what's below. 7. REMOTE CONTROL VALVE: RAIN BIRD PESB GRAVEL 5. BARB X FEMALE THREAD CONNECTOR: 9. 3" MINIMUM DEPTH OF -Y4" WASHED 11. 3" MINIMUM DEPTH 3/4" WASHED PEA GRAVEL NOTES: (INCLUDED IN XCZ-PRB-100-COM KIT) 17. PVC SCH 80 NIPPLE, CLOSE (INCLUDED IN RAIN BIRD XFD-TFA FITTING GRAVEL 12. COMMON BRICK (2 NEEDED) BUNDLE AND TAPE WIRES AT 12'O.C. PIGTAIL AND LOOP CONTROL WIRES AT ALL 90' Call before you dig. 8. PRESSURE REGULATING QUICK CHECK BASKET XCZ-PRB-100-COM KIT) 6. X" BLANK DRIPLINE TUBING: RAIN BIRD 10. COMMON BRICK 2 REQUIRED CHANGES IN DIRECTION. SPLICING OF WIRE RUNS IS NOT ALLOWED UNLESS APPROVED FILTER: RAIN BIRD PRB-QKCHK-100 (INCLUDED 18. COMMON BRICK - 4 REQUIRED 7XF SERIES 11. FILTER FABRIC BY THE CITY. 36" MIN. COVER IS REQUIRED FOR RECLAIMED WATER MAINLINE (WHERE 19. FILTER FABRIC . BARB X MALE THREAD CONNECTOR: RAIN APPLICABLE). INSTALL 1'x1'X1' THRUST BLOCK AT ALL TERMINAL POINTS ON MAINLINE. IN XCZ-PRB-100-COM KIT) BIRD XFD-MA FITTING D ri trol Valve Assern ly J Air Relief Valve K Automatic Flush Valve L Trenchinc SHEET 6 OF 12 p DRAWING NO. 5150