Loading...
HomeMy WebLinkAbout3706-8of 1'/Angle2 "(1I/2'x1/4 " MINE elt re". 'A "Steel Plate DETAIL -PLATE STIFFENER ALTERNATE JUNCTION NOTES: 1. Riser pipe shall extend to 'Elev. A. 2. Elevation A, D1 , D2 , LI , L2 are shown on plans. 3. Corrugated steel pipe shall conform to AASHTO M-36. 4. Grote assembly shall be galvanized after fabrication. 5. For DI =54" and larger, weld 11/2"x11/21x1/4 " angles -to plate with 1' welds at 6" O.C. 6. n=number of bars on grate cssembly. 7. Gouge of pipe for diarrater D2 shall be same as for riser. 8. Riser and stub shall be shop fabricated and galvanized after welding. 9. The following shall be stencilled using 2 inch high letters end block paint on the face of the curb adjacent to the inlet (either side) and on the top ,of the Inlet: Teflon tape 2V2"x2%2"x76" Stl. bar (typ) Scarf and %"x%' Spacer rla 1/2" Allen bolt HOLD-DOWN Rhg 0.0. (TyOrn" places Y2 ' std. pipe or rr 1d steel bar t A 'x2" Irk). /4hotop p match late BOTTOM VIEW CAGE RETAINER RING NO DUMPING DRAINS TO OCEAN ORANGE COUNTY ENVIRONMENTAL MANAGEMENT AGENCY Adopted: Res. 77-S2 Revised: Res. 96-546 INLET TYPE V STD. PLAtL 1305 SHT. 2 OF 2 1/4"x 51" DIAM. STL. PLATE 1/4"x 6" STL. BAN D NICOLON MIRAFI 140N FILTER FABRIC CONST 3" THICK A.C. SLOPE PROTECTION ELEV. A: 42.0 Di: 48" D2: 36" Li: 10.83' L2: 2.5' 1/4"x 2" STL. BAR @ 6" 0.C. a N z LrJ o PIPE RIM 2' 1/4"x 6" STL. BAND 40.0 /FL a N a N 6" x 12" OPENING 2' 12" (TYPT 48" DIAM. C. .P. 2' 2' 42.0 MODIFIED "TYPE V" INLET DETAIL 8A SCALE: 1"=2' ROP R/W 7644.6 FS 3/ " Hole, 'H.D.". equally spaced Center of hole to be 1" from 0.D. of plate Elev. A 1-6 (See note 5) ee Stiffener etail next page BOTTOM VIEW TOP PLATE See detail for Locking Devices Grading at lip, unless otherwise shown on plan. 'l: /2 n places Standard galvanized connection band. C.S.P. R.C.P. slope to drain Conc. slob ELEVATION D. RISER DIAMETER C.S.P. GAUGE 18"-27" 16 30"-39" 14 42`-48" 12 51"-66' 10 '"---Dry pock DI t n" HD" 18' 40' 9 2 24"-27" 30' 12 150 mm (61 30'-3 3" 24' 15 900 ms (36') 36'-39" 20' 18 3 42"-45' 16.5' 22 nut (10') 48'-S1' 14.5' 25 1500 ass (601 '1650 54'-57" 13' 28 4 60'-63' 11.5' 31 300 as (127 66' 10.5' 34 -ORANGE COUNTY ENVIRONMENTAL MANAGEMENT AGENCY Approved. Adopted: Res. 77-92 Revised: Res. 96-546 WLZoun. a' Public Worts INLET TYPE -V STD. PLAN 1305 GRADE SURFACE TO DRAIN \\r //,/ /\\\ /\\\ CONST 3" THICK A.C. SLOPE PROTECTION NOTES: FABRICATE WELDED ASSEMBLY WITH MODIFICATIONS AS SHOWN HEREON. CONSTRUCT STRUCTURE PER 0.C.E.M.A. (0.C.P.F. & R.D.) STD. PLAN 1305. WRAP W/NICOLON MIRAFI 140N FABRIC AND SECURE WITH CHICKEN WIRE. 10+64.31 END OF PIPE FL EDGE PROP R/W 23+58.73_ LINE =10+00.00 LAT 'E-1 ON .68 BCS. / SCE R/W 1 / 0-CONSTRUC % R.C.P. /1® CTRUCT C.S.P. INC CONSTRUCT/ON ' OTES: ORM DRAIN (D LOAD SHOWN ON PLAN). MODIFIED TYPE V (SEE DETAIL 8A ON SHT. 8) / CURVE TABLE CURVE DELTA RADIUS LENGTH TANGENT C4 34'41'52" 22.50 13.63 Z03 INLET DETAIL 8B SCALE: 1'=20' DIAL BEFORE YOU DIG Eff TWO WORKING DAYS YOUBEFORE TOLL FREE • 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 2ND BRICK ROW ALL CASES 5" THICK GROUT SHT. 1 OF 2] 2't Cement grout copping at end of pipe SECTION PIPE Brick laid lengthwise* . and mortared "Inside edge of R.C.P. groove or end of pipe (if broken) Cement grout capping ELEVATION, Brick a mortar closure PIPE CLOSURE -TYPE "B" (Brick and Mortar) L Type 'B" closure for '0' not larger than 36' unless approved or specified try the Engineer. 2.See specifications for additional Information. 3.FOR LARGER THAN 36' USE TYPE'A' , CLOSURE PER SBCFCD S.P. 176. SEE SHT. 4 SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT REVISIONS OWN. SY. DAT[ C.L. 5-9-63 PRA NO. S.P. *176A -I LOCATION TIE PATE SCORING LINE 2 EXTRA I51A(041 ON 2 SIDES OF MANHOLE FRAME ANO COVER CATCH BASIN MANHOLE FRAME AND COVER i d/ I ' ISM 4 300 mm(040121 EACH WAY 5 mm(I/4')R `*-100 mm (41R "'FLOW LINE DO WPE1LL -CURB LINE STEPS STEPS e tI d ( iLic<1.0.440/R.' -7-100 mm ' 1- 11 I 1 DOWEL (TVP.) I I PLAN • Oe 100 ova (4114114. 300 awn (Ir)MAX. 3 me )R FACE PLATO ASSEMBLY STREET. GUTTER. OR LOCAL DEPRE3- ION SURFACEi SLOPE OPTIONAL SUBGRADE 8 SECTION A -A CONNECTOR PIPE OR MONOLITHIC CATCH BASIN CONNECTION DOWEL DETAIL S TR U CTU R AL DATA WALL AND SLAB DIMENSIONS AND REINFORCEMENT REQUIREMENTS MAX w MAX V REINFORCEMENT 11r REQUIRED IN FRONT REAR BOTTOM END WALL WALL SLAB WALL 1.0 6(3.51 2.4 Wel ) 150 ran(61 1.0 n(3.5' ) 3.5 m(121 200 mm(e-1 2.0 m(71 I.8 ads') 150 mm(61 2.0m(7') 3.5 m(ir) 200 Mn(B') 4.0 6(4.1 1.2 .(49 150 msd61 2.4 air 1 150 mm(61 4.0 m(14') z o � N • ID 3.5 m1121 1.2 rd4') 200 mm(8') I.8m(6') 150 rwn(61 150 mm(61 2.4 m(e') 200 mm(89 3.0 m(101 3.5 m(121 200 made') 200 mm(8') 150 mm(61 200 mm(81 150 arr(s') 200 mm(81 150 arts') 200 motel 250 mm I07 f/0 150 6ni61 200 mnde7, C 200 *. S') �Mj 250 srar(t0') N 250 0.11101 #4 REBAR 0 12' 0.C. FOR W ) 9 64281). V ) 3.3 m(I2) OR 8 ' 1.2 m(41 SEE PROJECT PLANS . AMERICAN PUBUC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED SY TME OREENIPOOK COMMITTEE ism REV. MI • CURB,OPENING CATCH BASIN STANDARD PLAN 30METRIC 0 - 2 SHEET 1 OF 2 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION NOTES: 1. WHERE THE BASIN IS TO BE CONSTRUCTED WITHIN THE LIMITS OF EXISTING OR PROPOSED SIDEWALK OR IS CONTIGUOUS TO SUCH SIDEWALK. THE TOP SLAB OF THE BASIN MAY BE POURED EITHER MONOLITHIC WITH THE SIDEWALK OR SEPARATELY. USING THE SAME CLASS OF CONCRETE AS IN THE BASIN. WHEN POURED MONOLITHICALLY. THE SIDEWALK SHALL BE PROVIDED WITH A WEAKENED PLANE OR A 25 mm(I') DEEP SAWCUT CONTINUOUSLY AROUND THE EXTERNAL PERIMETER OF THE CATCH BASIN WALLS. INCLUDING ACROSS THE FULL WIDTH OF THE SIDEWALK. SURFACE OF ALL EXPOSED CONCRETE SHALL CONFORM IN SLOPE. GRADE. COLOR. FINISH. AND SCORING TO EXISTING OR PROPOSED CURB AND WALK ADJACENT TO THE BASIN. 2. ALL CURVED CONCRETE SURFACES SHALL BE FORMED BY CURVED FORMS. AND SHALL NOT BE SHAPED BY PLASTERING. 3. FLOOR OF BASIN SHALL BE GIVEN A STEEL TROWEL FINISH AND SHALL HAVE A LONGITUDINAL AND LATERAL SLOPE OF 1:12 MINIMUM AND 1:3 MAXIMUM. EXCEPT WHERE THE GUTTER GRADE EXCEEDS 8 PERCENT. 1N WHICH CASE THE LONGITUDINAL SLOPE OF THE FLOOR SHALL BE THE SAME AS THE GUTTER GRADE. SLOPE FLOOR FROM ALL DIRECTIONS TO THE OUTLET. 4. DIMENSIONS: B = 970 mm(3'-2') V = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF THE CATCH BASIN AT THE OUTLET = 1.35 m(4.5'). YU = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT AT THE UPSTREAM END OF THE BASIN. AND SHALL BE DETERMINED BY THE REQUIREMENTS OF NOTE 3. BUT SHALL. NOT BE LESS THAN CURB FACE PLUS 300 mm(121. V 1 = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF THE INLET. NOTED ON THE PROJECT PLANS. H = NOTED ON THE PROJECT PLANS. W = NOTED ON THE PROJECT PLANS. A * THE ANGLE. IN DEGREES. INTERCEPTED BY THE CENTERLINE OF THE CONNECTOR PIPE AND THE CATCH BASIN WALL TO WHICH THE CONNECTOR PIPE IS ATTACHED. 5. PLACE CONNECTOR PIPES AS INDICATED ON THE PROJECT PLANS. UNLESS OTHERWISE SPECI- FIED. THE CONNECTOR PIPE SHALL BE LOCATED AT THE DOWNSTREAM END OF THE BASIN. WHERE THE CONNECTOR PIPE IS SHOWN AT A CORNER. THE CENTERLINE OF THE PIPE SHALL INTERSECT THE INSIDE CORNER OF THE BASIN. THE PIPE MAY BE CUT AND TRIMMED AT A SKEW NECESSARY TO INSURE MINIMUM 80 mm(3') PIPE EMBEDMENT. ALL AROUND. WITHIN THE CATCH BASIN WALL. AND 75 arn(3•) RADIUS OF ROUNDING OF STRUCTURE CONCRETE. ALL AROUND. ADJACENT TO PIPE ENDS. A MONOLITHIC CATCH BASIN CONNECTION SHALL BE USED TO JOIN THE CONNECTOR PIPE TO THE CATCH BASIN WHENEVER ANGLE 'A' IS LESS THAN 70 DEGREES OR GREATER THAN 110 DEGREES. OR WHENEVER THE CONNECTOR PIPE 1S LOCATED IN A CORNER. THE OPTIONAL USE OF A MONOLITHIC CATCH BASIN CONNECTION IN ANY CASE IS PERMITTED. MONOLITHIC CATCH BASIN CONNECTIONS MAY BE CONSTRUCTED TO AVOID CUT- TING STANDARD LENGTHS OF PIPE. 6. STEPS SHALL BE LOCATED AS SHOWN. IF THE CONNECTOR PIPE INTERFERES WITH THE STEPS. THEY SHALL BE LOCATED AT THE CENTERLINE OF THE DOWNSTREAM END WALL. STEPS SHALL BE SPACED 300 mm(121 APART. THE TOP STEP SHALL BE 175 mm(T) BELOW THE TOP TO THE MANHOLE AND PROJECT 65 mm(2-1/2'). ALL OTHER STEPS SHALL PROJECT 130 mm(5'). 7. DOWELS ARE REQUIRED AT EACH CORNER AND AT 2 m(7') ON CENTER (MAXIMUM) ALONG THE BACKWALL. 8. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN: 308 MONOLITHIC CATCH BASIN CONNECTION 309 CATCH BASIN REINFORCEMENT 310 CATCH BASIN FACE PLATE ASSEMBLY AND PROTECTION BAR 312 CATCH BASIN MANHOLE FRAME AND COVER 635 STEEL STEP 636 POLYPROPYLENE PLASTIC STEP 9. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EOUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING BARS SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 300 - 2 SFIEIcT2oF2 CURB OPENING CATCH BASIN REV. REVISION DESCRIPTION r DATE ENGR. CITY DATE 450 not (181" 300 ars ((27 123 on (31 600 an (241 300 we ((2') 150 mm (61 750 ars (30'1 450 an (187 173 bra (7') 900 ms (36') 450 nm (187 225 m (9.1 1050 Tara (42'>w 450 we (18') 225 lata (9') 1200 mm (48') 450 urs (18') ,250 nut (10') 1425 am (57') 450 mat (18')1250 sea (10') 1500 ass (601 '1650 525 srs (211 273 an (111 am (661 525 ass (21') 275 met (11 1800 ars (721 600 alis (24') 300 as (127 A Re Ls TAD 01 Lieu i g'e-/ ISM 0 300 mm (e4 a i2' 330-C-23 (560-C-3250) CONCRETE L/2 (TYP.) 25 mm (11 (TYP.) NEW OR ° EXIST. PIPE n FLOW • ISM 0 300 mm (e4 0 12') CUT L NE 150 mm 3 -ISM (.4) CIRCULAR TIES. SEE NOTE 9 CUT NO. 1 N 90° CUT 2 LINE 150 mm 16.1 MIN, D L ' T 300 arm (12') 300 an (121 (00 ars (4') 450 not (181" 300 ars ((27 123 on (31 600 an (241 300 we ((2') 150 mm (61 750 ars (30'1 450 an (187 173 bra (7') 900 ms (36') 450 nm (187 225 m (9.1 1050 Tara (42'>w 450 we (18') 225 lata (9') 1200 mm (48') 450 urs (18') ,250 nut (10') 1425 am (57') 450 mat (18')1250 sea (10') 1500 ass (601 '1650 525 srs (211 273 an (111 am (661 525 ass (21') 275 met (11 1800 ars (721 600 alis (24') 300 as (127 CUT N0. 2 3.14 (00-D) DETAIL 'A' (SEE NOTE 10) SONO -TUBE. OR EOUAL. INTERIOR FORM CUT NO. Is SAW THE TUBE AT AN ANGLE OF A/2 WITH THE TRANS- VERSE PLANE. REVERSE ONE SECTION AND TAPE BOTH SECTIONS TOGETHER FORMING THE DEFLECTION ANGLE A. CUT NO. 2: SAW THE TUBE LONGITUDINALLY REMOVING A STRIP 3.14 (D0-0) WIDE ON THE SIDE OPPOSITE THE OPEN JOINT. BEND THE ENDS OF THE CUT TOGETHER AND INSERT THE TUBE IN THE PIPE. INTERIOR SURFACE OF PIPE DETAIL 'B' TYPICAL. JOINT FOR REINFORCED CONCRETE PIPE - AMERICAN PUBUC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER N0. OF CIRCULAR TIES 525 mm (211 OR LESS BY THE PUBUC WORKS STANDARDS INC-. REV. 19911 CONCRETE COLLAR FOR RCP 300PROMULGATED mm (12") THROUGH 1800 mm (72") STANDARD PLAN 1.1E7RIC 380 - 2 SHEET 1 OF 2 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION NOTES I. A CONCRETE COLLAR IS REQUIRED WHERE THE CHANGE IN GRADE • EXCEEDS 10 PERCENT. 2. FOR CURVE JOINTS (SEE DETAIL B. SHEET I) IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE THAT IS GREATER THAN 25 mm (11. BUT IS LESS THAN 75 mm((3') A CONCRETE COVER IS REQUIRED IN ACCORDANCE WITH SUBSECTION 306-1.2.4 OF THE SSPWC. IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE THAT IS EQUAL TO OR GREATER THAN 75 mm (31. BUT LESS THAN 150 mm (6'). A CONCRETE COLLAR IS REQUIRED. IF THE CLEAR SPACE IS 150 mm (6') OR GREATER. A TRANSITION STRUCTURE IS REQUIRED. 3. CONCRETE COLLAR SHALL NOT BE USED FOR A SIZE CHANGE ON THE MAIN LINE. 4. CONNECTOR PIPES A. WHERE PIPES OF DIFFERENT DIAMETERS ARE JOINED WITH A CONCRETE COLLAR. L AND T SHALL BE THOSE OF THE LARGER PIPE. De DI OR 02. WHICHEVER IS GREATER. B. WHEN D1 IS EQUAL TO OR LESS THAN D2. JOIN INVERTS AND WHEN Di IS GREATER THAN D2, JOIN SOFFITS. 5. FOR PIPE LARGER THAN 1800 mm (721 SPECIAL COLLAR DETAILS ARE REQUIRED. 6. FOR PIPE SIZE NOT LISTED USE NEXT SIZE LARGER. 7. REINFORCEMENT SHALL CONFORM TO ASTM A 615 M (A 615) GRADE 300(40). 8. WHERE REINFORCING IS REQUIRED THE DIAMETER OF THE CIRCULAR TIES SHALL BE D+(2X WALL THICKNESS) + T. 9. REINFORCING SHALL BE USED WHERE THE PIPE DIAMETER IS GREATER THAN 525 mm (21') AND ON ALL PIPES WHERE THE SPACES BETWEEN THE EXTREME OUTER ENDS IS 75 mm (31 OR LARGER. CIRCULAR TIES: PIPE DIAMETER N0. OF CIRCULAR TIES 525 mm (211 OR LESS 3 . 600 mm (24') TO 750 mm (30') 3 825 mm (33') TO 1425 mm (57') 4 1500 min (60') TO 1800 mm (72') 5 . WHERE THE SPACE BETWEEN PIPE ENDS EXCEEDS 75 mm (3'). THE NUMBER OF CIRCULAR TIES SHALL BE INCREASED TO MAINTAIN AN APPROXIMATE SPACING OF (50 mm (6') 0.C. 10. WHERE THE PIPE IS 525 mm (214 OR LESS IN DIAMETER AN INTERIOR FORM OF UNSEALED SONO -TUBE OR EQUAL SHALL BE USED TO PROVIDE A SMOOTH INTERIOR JOINT. THE PAPER FORM MAY BE LEFT IN PLACE (SEE DETAIL A). WHEN THE PIPE IS 600 mm (24') OR LARGER A REMOVABLE INTERIOR FORM SHALL BE USED OR THE INTERIOR JOINT SHALL BE COMPLETELY FILLED WITH MORTAR AND NEATLY POINTED. II. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBUC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 380 `2 SHEET20F2 CONCRETE COLLAR FOR RCP 300 aim (12") THROUGH 1800 mm (721 tRECORI] DRAWING THESE RECORD DRAWING HAVE BEEN PREPARED, ICI PART, ON THE BASIS OF INFORMATION COMPILED AND 1 FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE DOCUMENTS AS A RESULT THEREOF SHOULD CONS TRUC TION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND. STANDARDS IN EFFECT. BENCH MARK: if 8-17 CAL TRANS BENCHMARK 0-17. A BRASS CAP IN THE CONCRETE BASE OF THE SOUTH LEG OF AN SCE TOWER 343' NORTH OF HIGHLAND, Q2 M/ WEST OF SAN SEVAINE RD., 2.65 MI WEST OF SIERRA AVE ELEVATION: 1 1428.609 BASIS OF BEAR/NGS: THE BRG NO8959'31 "E ALONG THE CL SUMMIT AVE AS SHOWN ON 77?. NO. 16427-1, M.B. 296/7-11. Prepared Under The Supervision Of : PREPARED IN THE OFFICE OF MADOLE AND ASSOCIATES, INC. 760-A SOUTH ROCHESTER AVENUE ONTARIO, CA 91761 PHONE (909) 937-9151 IL LATERAL/CONNECTOR PIPE CLASS C i MORTAR STA. PT. I tB 5. MAIN LINE RCP CASE 1 PLAN 265 Kg -C -I4 Apo (450-C-2000) CONC. ENCASEMENT. SEE NOTE 5 SEE NOTE 3 45. • BEDDING OF INLET PIPE BACKFILL WITH 265 C-14 Mpe (450-C-20001 CONCRETE OR COMPACT SOIL TO RELATIVE DENSITY REQUIRED BY SPECIFICATIONS UNDISTURBED EARTH CONC. PIPE. RCP OR CSP ERIN LINE RCP 1 41 115 mis (I/2') MIN. ISEE NOTE 4 4454 FOR OUTLET SEE STD. g CATCH BASIN PLANS =4A. CATCH BASIN FLOOR f Itirasa IV/4,„......,,,,, 4 SEE NOT CASE 2 (SEC NOTES 9 EL 101 CONC. PIPE. RCP OR CSP VARIES TO SUIT CONDITIONS PLAN SEE NOTE 6 BEDDING. PER SPECIFICATIONS CASE I SECTION B -B CASE 1 SECTION C -C CASE 3 SADDLE CONNECTION AMERICAN PUBUC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED NY THE PUBLIC WORKS STANDARDS WC.. GREENBOOK COMMITTEE REV. 1996 JUNCTION STRUCTURE PIPE TO PIPE '.- STANDARD PLAN METRIC SHEET 1 OF 2 USE VVITH STANDARD SPECIFICATIONS FOR PUBUC WORKS CONSTRUCTION GENERAL NOTE 1. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. NOTES CASE I AND CASE 2 L IF ANGLE A IS LESS THAN 45' OR IF D IS LARGER THAN 600 mm (24'). THEN ANOTHER STANDARD STRUCTURE SHALL BE SPECIFIED. 2. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED ONE-HALF THE INSIDE DIAMETER OF THE MAIN LINE. 3. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY. IF THE INLET PIPE CANNOT ENTER RADIALLY. THEN ANOTHER STANDARD STRUCTURE SHALL BE SPECIFIED. 4. THE SIZE OF THE OPENING INTO THE MAIN LINE SHALL BE THE OUTSIDE DIAMETER OF THE INLET PIPE PLUS 30 mm (11 MINIMUM TO 75 rnm (31 MAXIMUM. 5. ALL CONNECTOR P IPES FOR CASE 2 SHALL BE ENCASED IN CONCRETE IF LAID WITHIN THE MAIN LINE EXCAVATED TRENCH OR IF LAID ON FILL WHICH HAS NOT BEEN DENSIFIED. 6. BURN OR CHIP END OF CONNECTOR PIPE FLUSH WITH INNER SURFACE OF MAIN LINE. ROUND EDGE OF CONCRETE PIPE OR RCP. 7. ALL CSP AND FITTINGS SHALL BE GALVANIZED. 8. STATION SPECIFIED ON THE PROJECT DRAWINGS APPLIES AT THE INTERSECTION OF THE INSIDE WALL OF MAIN LINE AND THE CENTER LINE OF INLET PIPE. 9. CASE 2 SHALL NOT BE USED TO CONNECT TO THE FLOOR OF A GRATING CATCH BASIN WHERE THE GRATE WILL BE SUBJECT TO VEHICLE TRAFFIC. 10. FOR CASE 2. NOT MORE THAN 3.5 m (12') OF INLET PIPE SHALL BE LOCATED WITHIN THE MAIN LINE EXCAVATED TRENCH. CASE 3 II. CONNECTIONS TO PIPES 525 mm (21') OR LESS IN DIAMETER WITHOUT JUNCTION STRUCTURES OR PRECAST Y BRANCHES SHALL BE MADE WITH SADDLES. 12. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED ONE-HALF THE INSIDE DIAMETER OF THE MAIN LINE. 13. TRIM OR CUT SADDLE TO FIT SNUGLY OVER THE OUTSIDE OF THE MAIN LINE SO ITS AXIS WILL BE ON THE LINE AND GRADE OF THE CONNECTOR PIPE. 14. THE OPENING INTO THE PIPE SHALL BE CUT AND TRIMMED TO FIT THE SADDLE SO THAT NO PART WILL PROJECT WITHIN THE BORE OF THE SADDLE PIPE. IS. THE CONNECTOR PIPE SHALL BE SUPPORTED AS SHOWN IN CASES I AND 2. AMERICAN PUBUC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN - METRIC JUNCTION STRUCTURE PIPE TO PIPE CITY OF FONTANA, CALIFORNIA DETAILS DRAWN BY: KNOX AVENUE A".644 s.1 Da tee7/4_4edc- RCE 3663 EXP. -30 6 DESIGNED BY: if CHECKED BY: SCALE: AS SHOWN DATE MARCH 2005 DRAWING NO. 3706 gc ec co J:\126-20121storm\sd08.dwa. 3/22/2005 10:46:45 AM. Dawn. Dawn