HomeMy WebLinkAbout5164-9LL
0
0
U
8.23 Al \
WAL �T�AVE
12.0 A2 16.3
WALNUT AVE
e
ALL
- WIRE SLEEVE
SLEEVE
1
4
WIRE SLEEVE
MADISON WAY
a
NOTES (TYPICAL):
1. 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.)
INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT
PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER
SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON
EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL
ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER.
2. MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR
SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE
SITE.
3. ADJUST ALL SPRINKLERS FOR 100% COVERAGE.
4. AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE
PROGRAMMED TO IRRIGATE SOLELY DURING EARLY MORNING.
DRIP IRRIGATION NOTES:
INSTALLATION NOTES
1. PRIOR TO INSTALLATION DRIPLINE AREA IS TO BE RAKED SMOOTH. ALL SHARP
OBJECTS AND DEBRIS THAT MAY PUNCTURE TUBING IS TO BE COLLECTED AND
DISPOSED OF.
2. INSTALL DRIPLINE AT A DEPTH OF 2". REFER TO IRRIGATION DETAILS FOR LAYOUT
INFORMATION.
3. ALL IRRIGATION LATERALS, AND IRRIGATION MAINLINE ARE TO BE SLEEVED UNDER
ALL PAVING AREAS. ALL SLEEVES ARE TO BE SCHEDULE 40 AND SIZED AT TWICE THE
SIZE OF PIPE TO BE SLEEVED.
4. DRIPLINE IS TO BE LAID OUT WITH ENOUGH 'PLAY' TO ALLOW FOR EXPANSION AND
CONTRACTION DUE TO CLIMATIC CONDITIONS.
5. ALL CUTS TO DRIPLINE, LATERAL LINES, AND MAIN LINE ARE TO BE AT 90 DEG TO
PIPE AND CLEANED PRIOR TO INSTALLATION.
6. DRIPLINES, IRRIGATION LATERALS AND IRRIGATION MAIN LINES ARE TO BE DEBRIS
FREE.
7. PRIOR TO OPERATION OF IRRIGATION SYSTEM OPEN ALL FLUSH VALVES AND RUN
WATER TO PURGE SYSTEM OF ALL DEBRIS.
8. DO NOTE USE ANY SOLVENTS OR DETERGENTS ON DRIPLINES.
9. LATERAL LENGTH FOR DRIPLINE NOT TO EXCEED MANUFACTURER'S
RECOMMENDATION.
WALNUT AVE
WIRE SLEEVE
.. .. 1•
a
CRU
2" WIRE SLEEVE
"r1
WIRE SLEEVE'
w
w
LL
w
-■-■-■-■-■-■_■-■_■_■�■.�■�:._s_■ '
LEGENDS AND NOTES:
IRRIGATION SCHEDULE
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
PSI
RADIUS
115
Rain Bird RWS-B-C, Root Watering System 1402 0.5 gpm
30
1'
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
PSI
RADIUS
ARC
25
Rain Bird 5006 -SAM -R -NP -SS -MPR
Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched
Precipitation Rotor (MPR nozzle). Arc and Radius as per
Symbol. With Seal -A -Matic Check Valve, and Non -Potable
Purple Cover. Pressure Regulating.
45
25'
e.ARC
30
Rain Bird 5006 -SAM -R -NP -SS -MPR
Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched
Precipitation Rotor (MPR nozzle). Arc and Radius as per
Symbol. With Seal -A -Matic Check Valve, and Non -Potable
Purple Cover. Pressure Regulating.
45
30'
dRC
Rain Bird 5006 -SAM -R -NP -SS -MPR
Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched
Precipitation Rotor (MPR nozzle). Arc and Radius as per
Symbol. With Seal -A -Matic Check Valve, and Non -Potable
Purple Cover. Pressure Regulating.
45
35'
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
V
Rain Bird MDCFPCAP
Dripline Flush Valve purple cap in compression fitting coupler.
For non -potable water use.
Rain Bird ARV075
3/4" Air Relief Valve, made of quality rust -proof materials, with a
6.0" drip valve box (SEB 7XB emitter box). Use with installation
below soil. The valve will allow air to escape the pipeline, thus
preventing water hammer or blockage.
Area to Receive Dripline
Rain Bird XFS-P-09-18 (18)
XFS Sub -Surface Pressure Compensating Landscape Dripline
w/Copper Shield Technology. 0.9GPH emitters at 18.0" O.C.
Dripline laterals spaced at 18.0" apart, with emitters offset for
triangular pattern. Purple Tubing for Non -Potable Water.
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
®
Rain Bird PESBR-PRS-D
1" Durable Chlorine -Resistant Valves for Reclaimed Water
Applications. With Scrubber Mechanism Technology, Purple
Flow Control Handle, and Pressure Regulator Module. Install
with QKCHK-100M Quick Check Basket Filter and Ball Valve.
Install in Purple Valve Box.
®
Rain Bird PESBR-PRS-D (2)
1", 1-1/2", and 2" Durable Chlorine -Resistant Valves for
Reclaimed Water Applications. With Scrubber Mechanism
Technology, Purple Flow Control Handle, and Pressure
Regulator Module. Install in Purple Valve Box
Rain Bird 33 -DNP
3/4" Brass Quick -Coupling Valve, with Corrosion -Resistant
Stainless Steel Spring, Locking Thermoplastic Non -Potable
Purple Rubber Cover, and 2 -Piece Body. Install in Purple
Valve Box.
p
1
Ball Valve
Watts B -6080 -SS -SH Full Port Brass Ball Valve - Line Size -
Install in Purple Valve Box
C)
Hunter IBV -R
1", 1-1/2", 2", and 3" Brass Electric Master Valve, Globe
Configuration, with NPT Threaded Inlet/Outlet, for Commercial/
Municipal Use. With Reclaimed Water ID Purple Tag.
Febco 825Y
Reduced Pressure Backflow Preventer w/ Recycled Water Tag
7)
`�
Controller Assembly
Toro Sentinel Model # SB12-U2-PS3-S3-VRA Assembly by
Turfstar Contact: Doug Dahl (760) 597-6045
X
FS
Flow Sensor
1" Data Industrial Flow Sensor Badger 735 Series 1"
Wire Bundle (as indicated for future use)
Purple Round Pull Box for wiring, contractor to install 2 spare
wires and 1 common wire in a pull box at all ends of the
mainline as shown on plan. Coil wires in valve box, and run
continuous wire back to controller. Label each wire with a
plastic I.D. tag at the wire bundle and at the controller.
CW
Water Meter 1"
With 1-1/2" Service Line - Install per Civil Plans
X
Irrigation Lateral Line: PVC Schedule 40
Purple PVC Schedule 40 irrigation pipe. Only lateral transition
pipe sizes 1" and above are indicated on the plan, with all
others being 3/4" in size.
Irrigation Mainline: PVC Class 315 SDR 13.5 Purple
Pipe Sleeve: PVC Schedule 40
SITE MAP
THIS SHEET
WALNUT AVENUE
i E, q `,11■ •■V■`I■lam• =�=N
iemilNan
CADENCE LANE
11.1. �l �]� �'., I it_
11i.
ri
!II IIIIIIpa r rill Ell III
IMI II �
0.m.
1
.e4e N FIRTI 1 -
or -min
'II! 11���-`�� v Eli tni W
BRUNO LANE
....--..--44,
��'�Il II��� ��. 1 Q ll s ...
LI• SONNET LANE di.
. 1
JUNIPER AVE
I\
NORTH
DATE
SUBMITTAL TRACKER
06-02-2014
1ST SUBMITTAL
TWO WORKING
DAYS BEFORE
YOU DIG
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE ENGR. aTY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT
NORTH
FRONTIER COMMUNITIES
TR 18657 - CFD LANDSCAPE PLANS
DRAWN BY:
JB, SF
DESIGNED BY:
SK
IRRIGATION PLAN
SCALE:
1"=10'
DATE
06-02-14
CHECKED BY:
SK
BM
ENGINEE
DATA " tY
DRAWING NO.:
Si‘L}
9
21