Loading...
HomeMy WebLinkAbout5164-11WATER EFFICIENT LANDSCAPE WORKSHEET ESTIMATED TOTAL WATER USE (ETWU) ETWU = (Eto)(0.62) [(PFXHA)/IE+SLA] Eto = REFERENCE EVAPOTRANSPIRATION FROM APPENDIX A (INCHES PER YEAR) PF = PLANT FACTOR FROM WUCOLS HA = HYDROZONE AREA [HIGH, MEDIUM AND LOW WATER USE AREAS] (SQUARE FEET) SLA = SPECIAL LANDSCAPE AREA (SQUARE FEET) 0.62 = CONVERSION FACTOR (TO GALLONS PER SQUARE FOOT) IE - IRRIGATION EFFICIENCY (MINIMUM 0.71) OR PER LOCAL AGENCY REQUIREMENTS HYDROZONE TABLE FOR CALCULATING ETWU MANUFACTURER/MODEUDESCRIPTION PSI PLANT FACTOR AREA (HA) Rain Bird 5006 -SAM -R -NP -SS -MPR Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched Precipitation Rotor (MPR nozzle). Arc and Radius as per Symbol. With Seal -A -Matic Check Valve, and Non -Potable Purple Cover. Pressure Regulating. HYDROZONE PLANT WATER USE TYPE(S) (PF) (SF) PF X HA (SF) Al MODERATE 0.5 1142 571 A2 MODERATE - 0.5 104 52 A3 MODERATE 0.5 2266 1133 A4 LOW 0.3 1321 396 A5 MODERATE 0.5 144 72 A6 MODERATE 0.5 2588 1294 A7 LOW • 0.3 2381 714 A8 MODERATE 0.5 144 72 A9 MODERATE 0.5 2660 1330 A10 MODERATE 0.5 112 56 TOTAL= 12862 5691 ESTIMATED TOTAL WATER USE = 280,266 GALLONS PER YEAR ETWU = (ETo)(0.62) [(PFXHA)/IE + SLA] Eto 0.62 PF *• HA ETWU IE + SLA Irrigation Mainline: PVC Class 315 SDR 13.5 Purple 56.4 0.62 - 5691280266 - 0.71 + 0 ETWU = 280266 Landscape Water Use Calculations Frontier Tr 18657 LMD Streetscape 1 Maximum Annual Water Allowance (Eto)(ET Adjustment Factor)(Landscape Area)(Conversion Factor) = MAWA 56.6 * 0.7 * 12862 * 0.62 = 315,947 gal / yr 2 Estimated Total Water Use Hydrozone # 1 (High) (ETo*Conversion Factor)(Plant Factor*Hydrozone Areal= ETWU Irrigation Efficiency 56.6 * 0.62 Hydrozone # 2 (Medium) * 0.7 * 0 0.71 0 gal / yr (ETo*Conversion Factor)(Plant Factor*Hydrozone Area) = ETWU Irrigation Efficiency 56.6 * 0.62 * 0.5 * 9160 Hydrozone # 3 (Low) 0.71 226,368 gal / yr (ETo*Conversion Factor)(Plant Factor*Hydrozone Area) = ETWU Irrigation Efficiency 56.6 * 0.62 * 0.3 * 3702 0.71 54,892 Total ETWU = 281,260 MAWA - ETWU = 34,687 gal / yr gal / yr (this number must be positive) BRUNO LANE MATCH BOTTOM RIGHT SHEET10 Ammimimmilimimmumumnimilimmilimminimmumpimmirmil II Y� O I III IIIIIHhIIuII � r'1 NOTES (TYPICAL): 1. 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.) INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2. MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE SITE. 3. ADJUST ALL SPRINKLERS FOR 100% COVERAGE. 4. AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE PROGRAMMED TO IRRIGATE SOLELY DURING EARLY MORNING. DRIP IRRIGATION NOTES: INSTALLATION NOTES 1. PRIOR TO INSTALLATION DRIPLINE AREA IS TO BE RAKED SMOOTH. ALL SHARP OBJECTS AND DEBRIS THAT MAY PUNCTURE TUBING IS TO BE COLLECTED AND DISPOSED OF. 2. INSTALL DRIPLINE AT A DEPTH OF 2". REFER TO IRRIGATION DETAILS FOR LAYOUT INFORMATION. 3. ALL IRRIGATION LATERALS, AND IRRIGATION MAINLINE ARE TO BE SLEEVED UNDER ALL PAVING AREAS. ALL SLEEVES ARE TO BE SCHEDULE 40 AND SIZED AT TWICE THE SIZE OF PIPE TO BE SLEEVED. 4. DRIPLINE IS TO BE LAID OUT WITH ENOUGH 'PLAY' TO ALLOW FOR EXPANSION AND CONTRACTION DUE TO CLIMATIC CONDITIONS. 5. ALL CUTS TO DRIPLINE, LATERAL LINES, AND MAIN LINE ARE TO BE AT 90 DEG TO PIPE AND CLEANED PRIOR TO INSTALLATION. 6. DRIPLINES, IRRIGATION LATERALS AND IRRIGATION MAIN LINES ARE TO BE DEBRIS FREE. 7. PRIOR TO OPERATION OF IRRIGATION SYSTEM OPEN ALL FLUSH VALVES AND RUN WATER TO PURGE SYSTEM OF ALL DEBRIS. 8. DO NOTE USE ANY SOLVENTS OR DETERGENTS ON DRIPLINES. 9. LATERAL LENGTH FOR DRIPLINE NOT TO EXCEED MANUFACTURER'S RECOMMENDATION. __1‹ a 1111 11 If 1I111i111111m MATCH TOP RIGHT JUNIPER AVE 1111111111111111111111 11111111111111 LIMIT OF WORK JUNIPER AVE LEGENDS AND NOTES: IRRIGATION SCHEDULE SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI RADIUS Rain Bird RWS-B-C, Root Watering System 1402 0.5 gpm 30 1' SYMBOL MANUFACTURER/MODEUDESCRIPTION PSI RADIUS RC 25 Rain Bird 5006 -SAM -R -NP -SS -MPR Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched Precipitation Rotor (MPR nozzle). Arc and Radius as per Symbol. With Seal -A -Matic Check Valve, and Non -Potable Purple Cover. Pressure Regulating. 45 25' e.ARC 30 Rain Bird 5006 -SAM -R -NP -SS -MPR Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched Precipitation Rotor (MPR nozzle). Arc and Radius as per Symbol. With SeaI-A-Matic Check Valve, and Non -Potable Purple Cover. Pressure Regulating. 45 30' ARC 35 Rain Bird 5006 -SAM -R -NP -SS -MPR Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched Precipitation Rotor (MPR nozzle). Arc and Radius as per Symbol. With SeaI-A-Matic Check Valve, and Non -Potable Purple Cover. Pressure Regulating. 45 35' SYMBOL MANUFACTURER/MODEUDESCRIPTION Rain Bird MDCFPCAP Dripline Flush Valve purple cap in compression fitting coupler. For non -potable water use. q) Rain Bird ARV075 3/4" Air Relief Valve, made of quality rust -proof materials, with a 6.0" drip valve box (SEB 7XB emitter box). Use with installation below soil. The valve will allow air to escape the pipeline, thus preventing water hammer or blockage. Area to Receive Dripline Rain Bird XFS-P-09-18 (18) XFS Sub -Surface Pressure Compensating Landscape Dripline w/Copper Shield Technology. 0.9GPH emitters at 18.0" 0.C. Dnpline laterals spaced at 18.0" apart, with emitters offset for triangular pattern. Purple Tubing for Non -Potable Water. SYMBOL MANUFACTURER/MODEUDESCRIPTION SApplications. Rain Bird PESBR-PRS-D 1" Durable Chlorine -Resistant Valves for Reclaimed Water With Scrubber Mechanism Technology, Purple Flow Control Handle, and Pressure Regulator Module. Install with QKCHK-100M Quick Check Basket Filter and Ball Valve. Install in Purple Valve Box. El)Reclaimed Rain Bird PESBR-PRS-D (2) 1", 1-1/2", and 2" Durable Chlorine -Resistant Valves for Water Applications. With Scrubber Mechanism Technology, Purple Flow Control Handle, and Pressure Regulator Module. Install in Purple Valve Box Rain Bird 33 -DNP 3/4" Brass Quick -Coupling Valve, with Corrosion -Resistant Stainless Steel Spring, Locking Thermoplastic Non -Potable Purple Rubber Cover, and 2 -Piece Body. Install in Purple Valve Box. r IWatts Ball Valve B -6080 -SS -SH Full Port Brass Ball Valve - Line Size - Install in Purple Valve Box 0 Hunter IBV -R 1", 1-1/2", 2", and 3" Brass Electric Master Valve, Globe Configuration, with NPT Threaded Inlet/Outlet, for Commercial/ Municipal Use. With Reclaimed Water ID Purple Tag. 0 Febco 825Y Reduced Pressure Backflow Preventer w/ Recycled Water Tag Controller Assembly Toro Sentinel Model # SB12-U2-PS3-S3-VRA Assembly by Turfstar Contact: Doug Dahl (760) 597-6045 X FS Flow Sensor 1" Data Industrial Flow Sensor Badger 735 Series 1" Wire Bundle (as indicated for future use) Purple Round Pull Box for wiring, contractor to install 2 spare wires and 1 common wire in a pull box at all ends of the mainline as shown on plan. Coil wires in valve box, and run continuous wire back to controller. Label each wire with a plastic I.D. tag at the wire bundle and at the controller. (6A -i) 0 Water Meter 1" With 1-1/2" Service Line - Install per Civil Plans Irrigation Lateral Line: PVC Schedule 40 Purple PVC Schedule 40 irrigation pipe. Only lateral transition pipe sizes 1" and above are indicated on the plan, with all others being 3/4" in size. Irrigation Mainline: PVC Class 315 SDR 13.5 Purple Pipe Sleeve: PVC Schedule 40 SITE MAP WALNUT AVENUE E THIS SHEET NORTH DATE SUBMITTAL TRACKER 06-02-2014 1ST SUBMITTAL DIAL BEFORE YOU DIG TOLL FREE TWO WORKING / DAYS BEFORE YOU DIG 811 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION DATE ENGR. aTY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT NORTH FRONTIER COMMUNITIES TR 18657 - CFD LANDSCAPE PLANS DRAWN BY: JB, SF DESIGNED BY: SK CHECKED BY: K BM IRRIGATION PLAN --7 O SCALE: 1"=10' DATE 06-02-14 OrhJ DATE CITY ENGINEER R.C.E. 51152 DRAWING NO.: 1 1 .SI G4' 21