HomeMy WebLinkAbout5164-11WATER EFFICIENT LANDSCAPE WORKSHEET
ESTIMATED TOTAL WATER USE (ETWU)
ETWU = (Eto)(0.62) [(PFXHA)/IE+SLA]
Eto = REFERENCE EVAPOTRANSPIRATION FROM APPENDIX A (INCHES PER YEAR)
PF = PLANT FACTOR FROM WUCOLS
HA = HYDROZONE AREA [HIGH, MEDIUM AND LOW WATER USE AREAS] (SQUARE FEET)
SLA = SPECIAL LANDSCAPE AREA (SQUARE FEET)
0.62 = CONVERSION FACTOR (TO GALLONS PER SQUARE FOOT)
IE - IRRIGATION EFFICIENCY (MINIMUM 0.71) OR PER LOCAL AGENCY REQUIREMENTS
HYDROZONE TABLE FOR CALCULATING ETWU
MANUFACTURER/MODEUDESCRIPTION
PSI
PLANT FACTOR
AREA (HA)
Rain Bird 5006 -SAM -R -NP -SS -MPR
Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched
Precipitation Rotor (MPR nozzle). Arc and Radius as per
Symbol. With Seal -A -Matic Check Valve, and Non -Potable
Purple Cover. Pressure Regulating.
HYDROZONE
PLANT WATER USE TYPE(S)
(PF)
(SF)
PF X HA (SF)
Al
MODERATE
0.5
1142
571
A2
MODERATE -
0.5
104
52
A3
MODERATE
0.5
2266
1133
A4
LOW
0.3
1321
396
A5
MODERATE
0.5
144
72
A6
MODERATE
0.5
2588
1294
A7
LOW
• 0.3
2381
714
A8
MODERATE
0.5
144
72
A9
MODERATE
0.5
2660
1330
A10
MODERATE
0.5
112
56
TOTAL=
12862
5691
ESTIMATED TOTAL WATER
USE = 280,266 GALLONS PER YEAR
ETWU = (ETo)(0.62) [(PFXHA)/IE + SLA]
Eto 0.62 PF *• HA
ETWU
IE + SLA
Irrigation Mainline: PVC Class 315 SDR 13.5 Purple
56.4 0.62 - 5691280266
-
0.71 + 0
ETWU = 280266
Landscape Water Use Calculations
Frontier Tr 18657 LMD Streetscape
1 Maximum Annual Water Allowance
(Eto)(ET Adjustment Factor)(Landscape Area)(Conversion Factor) = MAWA
56.6 * 0.7 * 12862
* 0.62 =
315,947
gal / yr
2 Estimated Total Water Use
Hydrozone # 1 (High)
(ETo*Conversion Factor)(Plant Factor*Hydrozone Areal= ETWU
Irrigation Efficiency
56.6 * 0.62
Hydrozone # 2 (Medium)
* 0.7 * 0
0.71
0
gal / yr
(ETo*Conversion Factor)(Plant Factor*Hydrozone Area) = ETWU
Irrigation Efficiency
56.6 * 0.62 * 0.5 * 9160
Hydrozone # 3 (Low)
0.71
226,368
gal / yr
(ETo*Conversion Factor)(Plant Factor*Hydrozone Area) = ETWU
Irrigation Efficiency
56.6 * 0.62 * 0.3
* 3702
0.71
54,892
Total ETWU = 281,260
MAWA - ETWU =
34,687
gal / yr
gal / yr
(this number must be positive)
BRUNO LANE MATCH BOTTOM RIGHT SHEET10
Ammimimmilimimmumumnimilimmilimminimmumpimmirmil
II
Y�
O
I III IIIIIHhIIuII
� r'1
NOTES (TYPICAL):
1. 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.)
INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT
PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER
SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON
EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL
ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER.
2. MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR
SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE
SITE.
3. ADJUST ALL SPRINKLERS FOR 100% COVERAGE.
4. AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE
PROGRAMMED TO IRRIGATE SOLELY DURING EARLY MORNING.
DRIP IRRIGATION NOTES:
INSTALLATION NOTES
1. PRIOR TO INSTALLATION DRIPLINE AREA IS TO BE RAKED SMOOTH. ALL SHARP
OBJECTS AND DEBRIS THAT MAY PUNCTURE TUBING IS TO BE COLLECTED AND
DISPOSED OF.
2. INSTALL DRIPLINE AT A DEPTH OF 2". REFER TO IRRIGATION DETAILS FOR LAYOUT
INFORMATION.
3. ALL IRRIGATION LATERALS, AND IRRIGATION MAINLINE ARE TO BE SLEEVED UNDER
ALL PAVING AREAS. ALL SLEEVES ARE TO BE SCHEDULE 40 AND SIZED AT TWICE THE
SIZE OF PIPE TO BE SLEEVED.
4. DRIPLINE IS TO BE LAID OUT WITH ENOUGH 'PLAY' TO ALLOW FOR EXPANSION AND
CONTRACTION DUE TO CLIMATIC CONDITIONS.
5. ALL CUTS TO DRIPLINE, LATERAL LINES, AND MAIN LINE ARE TO BE AT 90 DEG TO
PIPE AND CLEANED PRIOR TO INSTALLATION.
6. DRIPLINES, IRRIGATION LATERALS AND IRRIGATION MAIN LINES ARE TO BE DEBRIS
FREE.
7. PRIOR TO OPERATION OF IRRIGATION SYSTEM OPEN ALL FLUSH VALVES AND RUN
WATER TO PURGE SYSTEM OF ALL DEBRIS.
8. DO NOTE USE ANY SOLVENTS OR DETERGENTS ON DRIPLINES.
9. LATERAL LENGTH FOR DRIPLINE NOT TO EXCEED MANUFACTURER'S
RECOMMENDATION.
__1‹ a
1111 11 If 1I111i111111m
MATCH TOP RIGHT
JUNIPER AVE
1111111111111111111111 11111111111111
LIMIT OF WORK
JUNIPER AVE
LEGENDS AND NOTES:
IRRIGATION SCHEDULE
SYMBOL
MANUFACTURER/MODEL/DESCRIPTION
PSI
RADIUS
Rain Bird RWS-B-C, Root Watering System 1402 0.5 gpm
30
1'
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
PSI
RADIUS
RC
25
Rain Bird 5006 -SAM -R -NP -SS -MPR
Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched
Precipitation Rotor (MPR nozzle). Arc and Radius as per
Symbol. With Seal -A -Matic Check Valve, and Non -Potable
Purple Cover. Pressure Regulating.
45
25'
e.ARC
30
Rain Bird 5006 -SAM -R -NP -SS -MPR
Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched
Precipitation Rotor (MPR nozzle). Arc and Radius as per
Symbol. With SeaI-A-Matic Check Valve, and Non -Potable
Purple Cover. Pressure Regulating.
45
30'
ARC
35
Rain Bird 5006 -SAM -R -NP -SS -MPR
Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched
Precipitation Rotor (MPR nozzle). Arc and Radius as per
Symbol. With SeaI-A-Matic Check Valve, and Non -Potable
Purple Cover. Pressure Regulating.
45
35'
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
Rain Bird MDCFPCAP
Dripline Flush Valve purple cap in compression fitting coupler.
For non -potable water use.
q)
Rain Bird ARV075
3/4" Air Relief Valve, made of quality rust -proof materials, with a
6.0" drip valve box (SEB 7XB emitter box). Use with installation
below soil. The valve will allow air to escape the pipeline, thus
preventing water hammer or blockage.
Area to Receive Dripline
Rain Bird XFS-P-09-18 (18)
XFS Sub -Surface Pressure Compensating Landscape Dripline
w/Copper Shield Technology. 0.9GPH emitters at 18.0" 0.C.
Dnpline laterals spaced at 18.0" apart, with emitters offset for
triangular pattern. Purple Tubing for Non -Potable Water.
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
SApplications.
Rain Bird PESBR-PRS-D
1" Durable Chlorine -Resistant Valves for Reclaimed Water
With Scrubber Mechanism Technology, Purple
Flow Control Handle, and Pressure Regulator Module. Install
with QKCHK-100M Quick Check Basket Filter and Ball Valve.
Install in Purple Valve Box.
El)Reclaimed
Rain Bird PESBR-PRS-D (2)
1", 1-1/2", and 2" Durable Chlorine -Resistant Valves for
Water Applications. With Scrubber Mechanism
Technology, Purple Flow Control Handle, and Pressure
Regulator Module. Install in Purple Valve Box
Rain Bird 33 -DNP
3/4" Brass Quick -Coupling Valve, with Corrosion -Resistant
Stainless Steel Spring, Locking Thermoplastic Non -Potable
Purple Rubber Cover, and 2 -Piece Body. Install in Purple
Valve Box.
r
IWatts
Ball Valve
B -6080 -SS -SH Full Port Brass Ball Valve - Line Size -
Install in Purple Valve Box
0
Hunter IBV -R
1", 1-1/2", 2", and 3" Brass Electric Master Valve, Globe
Configuration, with NPT Threaded Inlet/Outlet, for Commercial/
Municipal Use. With Reclaimed Water ID Purple Tag.
0
Febco 825Y
Reduced Pressure Backflow Preventer w/ Recycled Water Tag
Controller Assembly
Toro Sentinel Model # SB12-U2-PS3-S3-VRA Assembly by
Turfstar Contact: Doug Dahl (760) 597-6045
X
FS
Flow Sensor
1" Data Industrial Flow Sensor Badger 735 Series 1"
Wire Bundle (as indicated for future use)
Purple Round Pull Box for wiring, contractor to install 2 spare
wires and 1 common wire in a pull box at all ends of the
mainline as shown on plan. Coil wires in valve box, and run
continuous wire back to controller. Label each wire with a
plastic I.D. tag at the wire bundle and at the controller.
(6A -i)
0
Water Meter 1"
With 1-1/2" Service Line - Install per Civil Plans
Irrigation Lateral Line: PVC Schedule 40
Purple PVC Schedule 40 irrigation pipe. Only lateral transition
pipe sizes 1" and above are indicated on the plan, with all
others being 3/4" in size.
Irrigation Mainline: PVC Class 315 SDR 13.5 Purple
Pipe Sleeve: PVC Schedule 40
SITE MAP
WALNUT AVENUE
E THIS SHEET
NORTH
DATE
SUBMITTAL TRACKER
06-02-2014
1ST SUBMITTAL
DIAL
BEFORE
YOU DIG
TOLL FREE
TWO WORKING
/ DAYS BEFORE
YOU DIG
811
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE
ENGR.
aTY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT
NORTH
FRONTIER COMMUNITIES
TR 18657 - CFD LANDSCAPE PLANS
DRAWN BY:
JB, SF
DESIGNED BY:
SK
CHECKED BY: K
BM
IRRIGATION PLAN
--7 O
SCALE:
1"=10'
DATE
06-02-14
OrhJ DATE
CITY ENGINEER R.C.E. 51152
DRAWING NO.: 1 1
.SI G4' 21