Loading...
HomeMy WebLinkAbout5164-100 Ow I- w Q 2■ -._■-■■_■-■-■=■s■-■-■-■_■ ■_■.-■--■-■-■-■-• - 18.0 A5 WALNUT AVE 4 • • 1•I n 11/2L-41 11'1 • MATCH TOP RIGHT 11 11111 II R mm1111111111111111 WI SL VE WIRE SLEEVE ■ ■ WIRE ■ SLEEVE is WIRE ■ SLEEVE ■ 11111111 11 11 111 111111111111 MATCH TOP RIGHT WIRE SLEEVE WIRE SLEEVE WIRE SLEEVE MATCH BOTTOM LEFT 11111111 ! 1II::;I.1 . 1 1111111111 .1 1 111 11I .`11tlfi minimum' MATCH TOP RIGHT 11111111 ATC 0 CSM LEFT • • • • W Z r1 if MATCH BOTTOM LEFT pint r 11111111'1111111111 WIRE SLEEVE ° 16 ° 1 11 11 1 1 11 11 1 41-r. I 1 1 WIRE SLLEVE- j j ¢... 6" I I '1 III I AY iT1�T1 I I I 1 11 1 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIInimiiliiV`111111111111111111111111 11111111 BRUNO LANE CRITICAL ANALYSIS Generated: 2014-05-30 07:17 P.O.C. NUMBER:A (STREETSCAPE) FLOW AVAILABLE Water Meter Size: 1" Flow Available: 37.50 gpm PRESSURE AVAILABLE Static Pressure at POC: Elevation Change: Service Line Size: Length of Service Line: Pressure Available: DESIGN ANALYSIS Maximum Station Flow: Flow Available at POC: Residual Flow Available: Critical Station: Design Pressure: Loss Elev. high head to valve: Pipe Loss Critical Head: Loss Fitting Factor: Loss through Valve: Pressure Req. at Critical Station: Loss for Fittings: Loss for Main Line: Loss for POC to Valve Elevation: Loss for Backflow: Loss for Master Valve: Loss for Water Meter: Critical Station Pressure at POC: Pressure Available: Residual Pressure Available: 74.00 psi 5.00 ft 1 1/2" 20.00 ft 71.00 psi 19.16 gpm 37.50 gpm 18.34 gpm A7 40.00 psi 0.00 psi 5.51 psi 0.55 psi 2.69 psi 48.75 psi 0.10 psi 1.00 psi 0.00 psi 11.31 psi 3.00 psi 1.63 psi 65.79 psi 71.00 psi 5.21 psi MATCH TOP LEFT SHEET 11 JUNIPER AVE 111111111111111111 NOTES (TYPICAL): 1. 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.) INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2. MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE SITE. 3. ADJUST ALL SPRINKLERS FOR 100% COVERAGE. 4. AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE PROGRAMMED TO IRRIGATE SOLELY DURING EARLY MORNING. DRIP IRRIGATION NOTES: INSTALLATION NOTES 1. PRIOR TO INSTALLATION DRIPLINE AREA IS TO BE RAKED SMOOTH. ALL SHARP OBJECTS AND DEBRIS THAT MAY PUNCTURE TUBING IS TO BE COLLECTED AND DISPOSED OF. 2. INSTALL DRIPLINE AT A DEPTH OF 2". REFER TO IRRIGATION DETAILS FOR LAYOUT INFORMATION. 3. ALL IRRIGATION LATERALS, AND IRRIGATION MAINLINE ARE TO BE SLEEVED UNDER ALL PAVING AREAS. ALL SLEEVES ARE TO BE SCHEDULE 40 AND SIZED AT TWICE THE SIZE OF PIPE TO BE SLEEVED. 4. DRIPLINE IS TO BE LAID OUT WITH ENOUGH 'PLAY' TO ALLOW FOR EXPANSION AND CONTRACTION DUE TO CLIMATIC CONDITIONS. 5. ALL CUTS TO DRIPLINE, LATERAL LINES, AND MAIN LINE ARE TO BE AT 90 DEG TO PIPE AND CLEANED PRIOR TO INSTALLATION. 6. DRIPLINES, IRRIGATION LATERALS AND IRRIGATION MAIN LINES ARE TO BE DEBRIS FREE. 7. PRIOR TO OPERATION OF IRRIGATION SYSTEM OPEN ALL FLUSH VALVES AND RUN WATER TO PURGE SYSTEM OF ALL DEBRIS. 8. DO NOTE USE ANY SOLVENTS OR DETERGENTS ON DRIPLINES. 9. LATERAL LENGTH FOR DRIPLINE NOT TO EXCEED MANUFACTURER'S RECOMMENDATION. LEGENDS AND NOTES: IRRIGATION SCHEDULE SYMBOL MANUFACTURER/MODEUDESCRIPTION PSI RADIUS 14r Rain Bird RWS-B-C, Root Watering System 1402 0.5 gpm 30 1' SYMBOL MANUFACTURER/MODEUDESCRIPTION PSI RADIUS ARC 25 Rain Bird 5006 -SAM -R -NP -SS -MPR Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched Precipitation Rotor (MPR nozzle). Arc and Radius as per Symbol. With Seal -A -Matic Check Valve, and Non -Potable Purple Cover. Pressure Regulating. 45 25' e.ARC 30 Rain Bird 5006 -SAM -R -NP -SS -MPR Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched Precipitation Rotor (MPR nozzle). Arc and Radius as per Symbol. With Seal -A -Matic Check Valve, and Non -Potable Purple Cover. Pressure Regulating. 45 30' e.ARC 35 Rain Bird 5006 -SAM -R -NP -SS -MPR Turf Rotor, 6.0" Pop -Up, Stainless Steel Riser, Matched Precipitation Rotor (MPR nozzle). Arc and Radius as per Symbol. With Seal -A -Matic Check Valve, and Non -Potable Purple Cover. Pressure Regulating. 45 35' SYMBOL MANUFACTURER/MODEUDESCRIPTION op Rain Bird MDCFPCAP Dripline Flush Valve purple cap in compression fitting coupler. For non -potable water use. q) Rain Bird ARV075 3/4" Air Relief Valve, made of quality rust -proof materials, with a 6.0" drip valve box (SEB 7XB emitter box). Use with installation below soil. The valve will allow air to escape the pipeline, thus preventing water hammer or blockage. Area to Receive Dripline Rain Bird XFS-P-09-18 (18) XFS Sub -Surface Pressure Compensating Landscape Dripline w/Copper Shield Technology. 0.9GPH emitters at 18.0" 0.C. Dripline laterals spaced at 18.0" apart, with emitters offset for triangular pattern. Purple Tubing for Non -Potable Water. SYMBOL MANUFACTURER/MODEUDESCRIPTION ® Rain Bird PESBR-PRS-D 1" Durable Chlorine -Resistant Valves for Reclaimed Water Applications. With Scrubber Mechanism Technology, Purple Flow Control Handle, and Pressure Regulator Module. Install with QKCHK-100M Quick Check Basket Filter and Ball Valve. Install in Purple Valve Box. EDReclaimed Rain Bird PESBR-PRS-D (2) 1", 1-1/2", and 2" Durable Chlorine -Resistant Valves for Water Applications. With Scrubber Mechanism Technology, Purple Flow Control Handle, and Pressure Regulator Module. Install in Purple Valve Box Rain Bird 33 -DNP 3/4" Brass Quick -Coupling Valve, with Corrosion -Resistant Stainless Steel Spring, Locking Thermoplastic Non -Potable Purple Rubber Cover, and 2 -Piece Body. Install in Purple Valve Box. I Ball Valve Watts B -6080 -SS -SH Full Port Brass Ball Valve - Line Size - Install in Purple Valve Box 0 Hunter IBV -R 1", 1-1/2", 2", and 3" Brass Electric Master Valve, Globe Configuration, with NPT Threaded Inlet/Outlet, for Commercial/ Municipal Use. With Reclaimed Water ID Purple Tag. 0 Febco 825Y Reduced Pressure Backflow Preventer w/ Recycled Water Tag Controller Assembly Toro Sentinel Model # SB12-U2-PS3-S3-VRA Assembly by Turfstar Contact: Doug Dahl (760) 597-6045 X FS Flow Sensor 1" Data Industrial Flow Sensor Badger 735 Series 1" (64-i) Wire Bundle (as indicated for future use) Purple Round Pull Box for wiring, contractor to install 2 spare wires and 1 common wire in a pull box at all ends of the mainline as shown on plan. Coil wires in valve box, and run continuous wire back to controller. Label each wire with a plastic I.D. tag at the wire bundle and at the controller. Water Meter 1" With 1-1/2" Service Line - Install per Civil Plans X Irrigation Lateral Line: PVC Schedule 40 Purple PVC Schedule 40 irrigation pipe. Only lateral transition pipe sizes 1" and above are indicated on the plan, with all others being 3/4" in size. Irrigation Mainline: PVC Class 315 SDR 13.5 Purple Pipe Sleeve: PVC Schedule 40 SITE MAP WALNUT AVENUE I\ DATE SUBMITTAL TRACKER 06-02-2014 1ST SUBMITTAL ANYVVVYVVVVVVVVVVVVVVA Er -VT DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG Y, YOU DIG TOLL FREE 811 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT W 30/15 EXP. DATE 7/2/14 NORTH FRONTIER COMMUNITIES TR 18657 - CFD LANDSCAPE PLANS DRAWN BY: JB, SF DESIGNED BY: SK CHECKED BY: SK BM IRRIGATION PLAN P ROVED-BYC �� i DATA tte`t CITY ENGINE E R.C.E. 51152 SCALE 1"=10' DATE 06-02-14 DRAWING NO.: S1CLt 21 21