Loading...
HomeMy WebLinkAbout3401-1GENERAL NOTES 1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14 STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 23 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 25 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34 MINIMUM D -LOAD FOR STORM DRAIN PIPE IS 1350. CITY OF FONTANA OFF-SITE STORM DRAIN IMPROVEMENT PLANS TRACT NO 16427 CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA ATTN: CARLOS NAVARRO 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-6632 SO. CALIFORNIA GAS COMPANY ATTN: GREG GASPAR 16231 VALLEY BLVD. FONTANA, CA. 92335 (909) 428-8411 EMERGENCIES: (800) 427-2200 SO. CALIFORNIA EDISON COMPANY 7951 REDWOOD AVE. FONTANA, CA. 92335 909 820-5598 - UNDERGROUND 909 875-5100 - TRANSMISSIONS 213 637-1233 - PIPELINES 909 357-6233 - DISTRIBUTION CRAWFORD CANYON MUTUAL WATER CO. ATTN: BASIL J. FABRIZIO (909) 463-9580 UNDERGROUND SERVICE ALERT (800) 422-4133 PACIFIC BELL CO. ATTN: NORMA GUILLOT 1265 N. VAN BUREN STREET SUITE 180 ANAHEIM, CA 92807 (714) 666-5401 COMCAST (CABLE TV) ATTN: JACK HAYES 1205 DUPONT AVENUE ONTARIO, CA. 91761 (909) 390-4738 VERIZON ATTN: STEVE HOCK 1400 E. PHILLIPS BLVD. POMONA, CA. 91766 (909) 469-6327 FONTANA WATER COMPANY ATTN: MICHAEL J. McGRAW 8440 NUEVO AVENUE FONTANA, CA 92335 (909) 822-2201 FAX: (909) 823-5046 WEST SAN BERNARDINO WATER CO. ATTN: LON TSAI 855 W. BASELINE ROAD RIALTO, CA 92377 PRIVATE ENGINEER'S NOTICE TO CONTRACTORS: /_ THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. \\\ \\\ \\\ GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL (1" MAX. SIZE). 1:1 SLOPE OR GREATER V OR ADEQUATE SHORING PIPE ZONE 90% COMPACTED NATIVE BACKFILL 3" MAX. SIZE i STORM DRAIN PIPE 0.6'D' IIIE III - J -J W 0 W m GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 1/2 CRUSHED STONE BEDDING. RCP TRENCH DETAIL NOT TO SCALE T1 - ------- SUMMIT SUMMIT " FONTANA HIGH SCHOOL #4 LRJ 1 NCI -J€4 -PROP: S.D: - ,L11•1 -E -713"1" I T 1 II [L- 11 \y II N (!) 0 AVENUE L_ --1-4-49:4] a 42-72, IIID: -l! ROS; S:D. LINE�"D 1 1 CURT(S , -\fil SEE SHET 8 Q.O.C. PER EXIST. PUMMR HTS.II S.D. PLANS DWG. isJ0. 3035 I NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE. 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING. 3. CLASS II AGG.BASE ALL TRENCHES LESS THAN 100' IN LENGTH. NOTE: COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS. f 0 0 L Q M w w V) w SIERRA (CARTER POINT OF CONNECTION EXIST. DRAINAGE PER CALTRANS EXISTING HIGHLAND CHANNEL LAKES AVENUE) PROP. S.D. LINE "A" PARKWAY CATAWBA AV STATE ROU 210 INDEX MAP FRWY SIERRA LAKES PKWY. VICINITY MAP NOT TO SCALE CONSTRUCTION NOTES 0 O 12 ONSTRUCT 66" DIA. R.C.P. D -LOAD PER PROFILE. CONSTRUCT 54" DIA. R.C.P. D -LOAD PER PLAN. ONSTRUCT 42" R.C.P. D -LOAD PER PROFILE. CONSTRUCT 36" DIA. R.C.P. D -LOAD PER PROFILE. ONSTRUCT 24" DIA. R.C.P. D -LOAD PER PROFILE. SUMMIT AVE SIERRA AVE. QUANTITIES CONSTRUCT MANHOLE PER A.P.W.A. STD. PLAN 320-1 SEE SHEET NO 10. ONSTRUCT MANHOLE PER A.P.W.A. STD. PLAN 322-1, SEE SHEET NO.10 CONSTRUCT JUNCTION STRUCTURE PER A.P.W.A. STD. PLAN 331-2, SEE SHEET NO. 10. ONSTRUCT CATCH BASIN PER STREET IMPROVEMENT PLAN. CONSTRUCT DOUBLE BRICK AND MORTAR PLUG. REMOVE EXIST. BULKHEAD AND CONSTRUCT TRANSITION STRUCTURE PER A.P.W.A. STD. PLAN 340-1 REMOVE EXIST. BRICK & MORTAR PLUG AND CONNECT TO EXIST. 42" PIPE. ONSTRUCT INLET TYPE V PER DETAIL, SEE SHEET NO. 9. SAWCUT, REMOVE & REPLACE EXISTING AC PAVEMENT. PER CITY STD. DETAIL 131. CONSTRUCT TRENCH REPAIR PER CITY STD. DETAIL 131. PAVEMENT CONSTRUCTION PER STREET IMPROVEMENT PLANS. OLD MILL AND CONSTRUCT 0.1' MIN. AC OVERLAY 2,129 LF 1,235 LF 1,975 LF 1,066 LF 309 LF 15 EA 5 EA 3 EA 9 EA 7 EA 1 EA 2 EA 1 EA 19,800 SF N/A 6070 SF 'i111I?AVENUE i� SHEET , DESCRIPTION 1 OF 10 TITLE SHEET 2 OF -- - - - r - 9+49.99 TO 19+50.00 SCE 10 PHASt' SHEET 4 Q M w w V) w SIERRA (CARTER POINT OF CONNECTION EXIST. DRAINAGE PER CALTRANS EXISTING HIGHLAND CHANNEL LAKES AVENUE) PROP. S.D. LINE "A" PARKWAY CATAWBA AV STATE ROU 210 INDEX MAP FRWY SIERRA LAKES PKWY. VICINITY MAP NOT TO SCALE CONSTRUCTION NOTES 0 O 12 ONSTRUCT 66" DIA. R.C.P. D -LOAD PER PROFILE. CONSTRUCT 54" DIA. R.C.P. D -LOAD PER PLAN. ONSTRUCT 42" R.C.P. D -LOAD PER PROFILE. CONSTRUCT 36" DIA. R.C.P. D -LOAD PER PROFILE. ONSTRUCT 24" DIA. R.C.P. D -LOAD PER PROFILE. SUMMIT AVE SIERRA AVE. QUANTITIES CONSTRUCT MANHOLE PER A.P.W.A. STD. PLAN 320-1 SEE SHEET NO 10. ONSTRUCT MANHOLE PER A.P.W.A. STD. PLAN 322-1, SEE SHEET NO.10 CONSTRUCT JUNCTION STRUCTURE PER A.P.W.A. STD. PLAN 331-2, SEE SHEET NO. 10. ONSTRUCT CATCH BASIN PER STREET IMPROVEMENT PLAN. CONSTRUCT DOUBLE BRICK AND MORTAR PLUG. REMOVE EXIST. BULKHEAD AND CONSTRUCT TRANSITION STRUCTURE PER A.P.W.A. STD. PLAN 340-1 REMOVE EXIST. BRICK & MORTAR PLUG AND CONNECT TO EXIST. 42" PIPE. ONSTRUCT INLET TYPE V PER DETAIL, SEE SHEET NO. 9. SAWCUT, REMOVE & REPLACE EXISTING AC PAVEMENT. PER CITY STD. DETAIL 131. CONSTRUCT TRENCH REPAIR PER CITY STD. DETAIL 131. PAVEMENT CONSTRUCTION PER STREET IMPROVEMENT PLANS. OLD MILL AND CONSTRUCT 0.1' MIN. AC OVERLAY 2,129 LF 1,235 LF 1,975 LF 1,066 LF 309 LF 15 EA 5 EA 3 EA 9 EA 7 EA 1 EA 2 EA 1 EA 19,800 SF N/A 6070 SF PECCRD DRiW$NG ThySE RZOOF;D D i. I C3 HAVE BEEN PREPARED, It F1 mT, ON THE BA= Or IiiR/11AATION OOLViLE.7 AND • - FlMilZ.H.ED BY OTHE 3. THE. Eai3=: zER NIL NOT CE R SFoH,• LE POR ANY EFAOSS On 03+: , OW3 WH CH 'NOORPC AT"D INTO TH2 GOCU 2NTS A RESULT THEBZOF. _ - BENCH MARK: / 8_17 CALTRANS BENCHMARK /8-17. A BRASS CAP IN THE CONCRETE BASE OF THE SOUTH LEG OF AN SCE TOWER 343' NORTH OF HIGHLAND 0.2 MI WEST OF SAN SEYAINE RD., 2.6. MI WEST OF SIERRA AVE. ELEVATION: / 1428.609 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS MAP SHOWN CL N00'1235�E ON RD. OF SURVEY MAP FILED IN R.S.B. 111/99-103 PHASE 1 APPROVAL LINES A, B, & D STA. 10+.00.00 TO 12+19.90 LINE C APPROVED BY: CITY ENGINEER R.C.E. 51152 DATE 2nd 05/21/02 1st 01/09/03; SUBMITTED: EL N O Z V 'TWO WORKING DAYS BEFORE YOU DIG 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION DATE ENGR. CITY DATE RECORD DWG g.$01 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. Prepared Under The Supervision Of : PREPARED IN THE OFFICE OF MADOLE AND ASSOCIATES, INC. 10601 CHURCH STREET , STE. 107 RANCHO CUCAMONGA, CA 91730 PHONE (909) 948-1311 CITY OF FONTANA, CALIFORNIA STORM DRAIN IMPROVEMENT PLANS DRAWN BY: SC DESIGNED BY: MA ate' f E `'? CHECKED B R.C.E. 62183 \. 1 EXP. 9-30-05 TRACT NO. 16427 EHEET APP''VED B C4TY ENGINEER R.C.E. 51152 41.14117 DATE SCALE: AS SHOWN DATE: JULY 2003 DRAWING NO.: 3401 J:\126-1662\storm\sd01.dwa. 09/18/2003 02:31:31 PM. GB.GB INDEX OF SHEETS SHEET , DESCRIPTION 1 OF 10 TITLE SHEET 2 OF 10 STORM DRAIN IMPROVEMENT LINE "A", KNOX AVE. STA. 9+49.99 TO 19+50.00 3 OF 10 STORM DRAIN IMPROVEMENT LINE "A", KNOX AVE. STA. 19+50.00 TO 30+57.76 4 OF 10 STORM DRAIN IMPROVEMENT LINE "A",CURTIS AVE. STA. 30+57.76 TO 40+42.47 5 OF 10 STORM DRAIN IMPROVEMENT LINE "B", LYTLE CREEK AVE. STA. 188+59.91 TO 198+95.65 6 OF 10 STORM DRAIN IMPROVEMENT LINE "C", KNOX AVE. STA. 10+00.00 TO 20+50.00 7 OF 10 STORM DRAIN IMPROVEMENT LINE "C", KNOX AVE. STA. 20+50.00 TO 28+16.51 8 OF 10 STORM DRAIN IMPROVEMENT LINE "D", CURTIS AVE. STA. 10+44.18 TO 15+24.58 9 OF 10 STORM DRAIN IMPROVEMENT LATERALS 10 OF 10 STORM DRAIN IMPROVEMENT DETAILS PECCRD DRiW$NG ThySE RZOOF;D D i. I C3 HAVE BEEN PREPARED, It F1 mT, ON THE BA= Or IiiR/11AATION OOLViLE.7 AND • - FlMilZ.H.ED BY OTHE 3. THE. Eai3=: zER NIL NOT CE R SFoH,• LE POR ANY EFAOSS On 03+: , OW3 WH CH 'NOORPC AT"D INTO TH2 GOCU 2NTS A RESULT THEBZOF. _ - BENCH MARK: / 8_17 CALTRANS BENCHMARK /8-17. A BRASS CAP IN THE CONCRETE BASE OF THE SOUTH LEG OF AN SCE TOWER 343' NORTH OF HIGHLAND 0.2 MI WEST OF SAN SEYAINE RD., 2.6. MI WEST OF SIERRA AVE. ELEVATION: / 1428.609 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS MAP SHOWN CL N00'1235�E ON RD. OF SURVEY MAP FILED IN R.S.B. 111/99-103 PHASE 1 APPROVAL LINES A, B, & D STA. 10+.00.00 TO 12+19.90 LINE C APPROVED BY: CITY ENGINEER R.C.E. 51152 DATE 2nd 05/21/02 1st 01/09/03; SUBMITTED: EL N O Z V 'TWO WORKING DAYS BEFORE YOU DIG 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION DATE ENGR. CITY DATE RECORD DWG g.$01 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. Prepared Under The Supervision Of : PREPARED IN THE OFFICE OF MADOLE AND ASSOCIATES, INC. 10601 CHURCH STREET , STE. 107 RANCHO CUCAMONGA, CA 91730 PHONE (909) 948-1311 CITY OF FONTANA, CALIFORNIA STORM DRAIN IMPROVEMENT PLANS DRAWN BY: SC DESIGNED BY: MA ate' f E `'? CHECKED B R.C.E. 62183 \. 1 EXP. 9-30-05 TRACT NO. 16427 EHEET APP''VED B C4TY ENGINEER R.C.E. 51152 41.14117 DATE SCALE: AS SHOWN DATE: JULY 2003 DRAWING NO.: 3401 J:\126-1662\storm\sd01.dwa. 09/18/2003 02:31:31 PM. GB.GB