HomeMy WebLinkAbout5077-1TRAFFIC SIGNAL CONSTRUCTION NOTES AND OUANii11ES
0
4
6
v
8
INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING
TYPE "R" CABINET, RVP2 VIDEO DETEC11ON SYSTEM, AND APPURTENANT EQUIPMENT.
CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD
DRAWING 4001. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECT-
RONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON
THE PLAN.
INSTALL TYPE IH -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND
SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS.
INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711 OR
EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER.
INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 4004
AND AS DIRECTED BY THE ENGINEER.
INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N.
INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS.
COORDINATE SERVICE WITH SCE (PAUL LARSON AT 909-357-6240 AND SCOTT
FIELI#ER AT 909-357-6121). VERIFY PHONE NUMBERS AT 11ME OF CONSTRUCTION.
CONSTRUCT 4" THICK PCC PAD ON COMPACTED NATIVE AROUND PROPOSED SIGNAL
CONTROLLER AND SERVICE CABINETS.
FURNISH AND INSTALL SIGN ON SIGNAL POLE AS SHOWN.
MOUNTING SHALL BE PER CALTRANS STD. PLANS RS4.
TRAFFIC SIGNAL GENERAL NOTES
1. TRAFFlC SIGNAL, SIGNING AND STRIPING, AND UGHTING SHALL CONFORM TO THESE
PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND
THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 (DATED 2010)
AND STANDARD PLANS (DATED 2010), THE CALIFORNIA MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS, 2012 EDITION.
2. LOCATION OF ALL UNDERGROUND FACILJTIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF ANY OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING
DAYS BEFORE DIGGING.
3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS
OTHERWISE SHOWN.
4. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING
WITH SOUTHERN CAUFORNIA EDISON COMPANY FOUR WEEKS IN ADVANCE OF NEED.
5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT
EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET.
6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY
OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK.
7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE
ENGINEER.
8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKLERS SYSTEMS IF NECESSARY.
g, THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE.
HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE
MINIMUM RADIUS OF 10 FEET.
10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL
PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES & UTIUZE
PEDESTRIAN COUNTDOWN TIMERS PER SPECIAL PROVISIONS.
11. ANY EXISTING TRAFFIC SIGNALS AND UGHTING SHALL REMAIN IN OPERATION UNTIL
REPLACED WITH NEW CONSTRUCTION.
12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO
CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT
AS NOTED CITY FURNISHED OR USTED AS CITY PROVIDED IN THE SPECIAL
PROVISIONS.
13. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT
OR POTENTIAL CONFLICT WITH THESE PLANS AND,OR SPECIFICATIONS FOR THIS
PROJECT.
14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE
BORING METHOD, TRENCH REPAIRS SHALL BE PER CITY STANDARD, AND SPECIAL
PROVISIONS, SECTION E.
15. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE
SHOWN ON THE PLANS.
SIGN LEGEND:
R9 -3a
USE 1==>
CROSSWALK
R9-3b(RT)
R3-4
4= USE
CROSSWALK
R9-3b(LT)
1 EA
1 EA
4EA
4EA
1 EA
1 EA
2 EA
4 EA
CITY OF FONTANA
TRAFFIC SIGNAL,
SLOVER AVENUE
PROJECT NO
SIGNING AND STRIPING
FOR
AND BEECH AVENUE
. SQ -23 -DE -07-38
V//2
PROJECT SITE
LEGEND:
<El- PROPOSED SIGNAL EQUIPMENT
6' X 50' VIDEO DETECTION ZONE
6' X 20' VIDEO DETECTION ZONE
6' X 6' VIDEO DETEC11ON ZONE
VICINflY MAP
NOT TO SCALE
INDEX OF SHEETS
SHEET 1
SHEET 2
SHEET 3
- TITLE SHEET
- TRAFFIC SIGNAL PLAN
- SIGNING AND STRIPING PLAN
SIGNING AND STRIPING CONSTRUCTION NOTES AND QUANTITIES
(j)APPLY 4" DOUBLE YELLOW CENTERLINE PER CALTRANS STD. PLAN A20A, DETAIL. 22 10 15
O2 APPLY WHITE THERMOPLASTIC TYPE IV ARROW PER CALTRANS STD. PLAN A24A. 15 SF
@ APPLY WHITE THERMOPLASTIC 12" CHEVRON STRIPES CO 30' C -C SPACING. 225 LF
520 LF
375 LF
(7,47 APPLY WHITE THERMOPLASTIC 12" SOUD CROSSWAU< AND/OR UMIT UNE
PER PER CALTRANS STD. PLAN A24E.
@ APPLY 4" WHITE LANE LINE PER CALTRANS STD. PLAN A20B, DETAIL. 27C
6O REMOVE CONFLICTING STRIPING/ MARKING BY SANDBLASTING.
7O REMOVE AND SALVAGE EXISTING SIGN AND POST TO THE CITY YARD IN A
REUSABLE CONDITION.
0 INSTALL NEW ROADSIDE SIGN ON POST PER CITY STD. DWG. 4003
650 LF
480 SF
8 EA
2 EA
9O INSTALL NEW ROADSIDE SIGN ON STREET LIGHT POLE 1 EA
SIGNING AND STRIPING GENERAL NOTES
1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF
ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED
AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBUC RIGHT-OF-WAY WITH
IN THE CITY LIMITS. CALL (909) 350-7610.
2. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE
PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE STANDARD PLANS AND
SPECIFICATIONS OF THE STATE OF CAUFORNIA, DATED 2010, AND THE CALIFORNIA MANUAL OF
UNIFORM TRAFFlC CONTROL DEVICES, DATED 2012.
3. IT SHALL BE THE RESPONSIBIUTY OF THE CONTRACTOR TO MAINTAIN TEMPORARY TRAFFlC CONTROL
AT ALL TIMES.
4. ALL SIGNS SHALL BE INSTALLED PER CITY STANDARD DETAIL 4003, UNLESS OTHERWISE SHOWN ON
THE PLANS.
5. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE
NOTED.
6. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 STRIPING
ON ROADWAYS WITH RAISED MEDIANS.
7. STRIPING AND PAVEMENT MARKINGS TO BE REMOVED SHALL BE REMOVED BY SANDBLASTING.
8. CONTROL POINTS OR "CAT TRACKING" SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO
APPUCATION OF PAVEMENT STRIPING AND LEGENDS. NOTIFY THE CITY AT LEAST TWO DAYS PRIOR
FOR APPROVAL OF "CAT TRACKING."
9. BLUE RAISED PAVEMENT MARKERS SHALL BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY
STANDARD PLANS.
10. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER.
LEGEND:
REMOVE EXISTING PROPOSED
S' TYPE IV (L or R) PAVEMENT ARROW
I) I' ROADSIDE SIGN
TRAFFIC STRIPE OR MARKING
SIGN LEGEND:
RIGHT LANE
MUST
TURN RIGHT
R3-7 (RT)
W3-3
AUTOCAD FILENAME:
M~AAWMWAWA
Vi4(7U
Y,
DIAL
BEFORE
YOU DIG
TOLL FREE
� I 1/)TWO WORKING
DAYS BEFORE
YOU DIG
1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE
ENCR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
KOA CORPORATION
PLANNING & ENGINEERING
3190 C. Shelby Street
Ontario, Califomia 91764
Tel: (909) 890-9693 Fax: (909) 890-9694
BENCH MARK: B.M. NO. 346 ELEVATION=1040.78'
DESCRIPTION: THE BENCHMARK FOR THIS SURVEY IS CITY OF FONTANA BENCHMARK 346 BEING A
RAIL ROAD SPIKE SET IN POLE FOR STANDARD #740088E, 30FT WEST OF
CENTERLINE BEECH AVE AND 660.1 FT SOUTH OF CENTERLINE SLOVER AVE.
Prepared Under The Supervision Of :
CITY OF FONTANA, CALIFORNIA
TITLE SHEET
DRAWN BY:
DESIGNED BY:
SLOVER AVENUE
AND
BEEn-AVENUE
CHECKED BY:
MING GUAN. R.C.E. 75793
Nt
C EN
DATE:
R R.C.E. 51152
SCALE:
As Noted
DATE:
DRAWING NO.:
5077
SAN BERNARDINO AVE
Lu
Q
CC
~
\-\P
F()
=
La
m VALLEY BLVD
10
OLEANDER AVE
CYPRESS AVE
10
SLOVER AVE
j/i�7
�
CHERRY AVE
0-1
HEMLOCK AVE
BEECH AVE
JURUPA AVE
POPLAR AVE
Z
--1
Z
P1
V//2
PROJECT SITE
LEGEND:
<El- PROPOSED SIGNAL EQUIPMENT
6' X 50' VIDEO DETECTION ZONE
6' X 20' VIDEO DETECTION ZONE
6' X 6' VIDEO DETEC11ON ZONE
VICINflY MAP
NOT TO SCALE
INDEX OF SHEETS
SHEET 1
SHEET 2
SHEET 3
- TITLE SHEET
- TRAFFIC SIGNAL PLAN
- SIGNING AND STRIPING PLAN
SIGNING AND STRIPING CONSTRUCTION NOTES AND QUANTITIES
(j)APPLY 4" DOUBLE YELLOW CENTERLINE PER CALTRANS STD. PLAN A20A, DETAIL. 22 10 15
O2 APPLY WHITE THERMOPLASTIC TYPE IV ARROW PER CALTRANS STD. PLAN A24A. 15 SF
@ APPLY WHITE THERMOPLASTIC 12" CHEVRON STRIPES CO 30' C -C SPACING. 225 LF
520 LF
375 LF
(7,47 APPLY WHITE THERMOPLASTIC 12" SOUD CROSSWAU< AND/OR UMIT UNE
PER PER CALTRANS STD. PLAN A24E.
@ APPLY 4" WHITE LANE LINE PER CALTRANS STD. PLAN A20B, DETAIL. 27C
6O REMOVE CONFLICTING STRIPING/ MARKING BY SANDBLASTING.
7O REMOVE AND SALVAGE EXISTING SIGN AND POST TO THE CITY YARD IN A
REUSABLE CONDITION.
0 INSTALL NEW ROADSIDE SIGN ON POST PER CITY STD. DWG. 4003
650 LF
480 SF
8 EA
2 EA
9O INSTALL NEW ROADSIDE SIGN ON STREET LIGHT POLE 1 EA
SIGNING AND STRIPING GENERAL NOTES
1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF
ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED
AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBUC RIGHT-OF-WAY WITH
IN THE CITY LIMITS. CALL (909) 350-7610.
2. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE
PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE STANDARD PLANS AND
SPECIFICATIONS OF THE STATE OF CAUFORNIA, DATED 2010, AND THE CALIFORNIA MANUAL OF
UNIFORM TRAFFlC CONTROL DEVICES, DATED 2012.
3. IT SHALL BE THE RESPONSIBIUTY OF THE CONTRACTOR TO MAINTAIN TEMPORARY TRAFFlC CONTROL
AT ALL TIMES.
4. ALL SIGNS SHALL BE INSTALLED PER CITY STANDARD DETAIL 4003, UNLESS OTHERWISE SHOWN ON
THE PLANS.
5. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE
NOTED.
6. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 STRIPING
ON ROADWAYS WITH RAISED MEDIANS.
7. STRIPING AND PAVEMENT MARKINGS TO BE REMOVED SHALL BE REMOVED BY SANDBLASTING.
8. CONTROL POINTS OR "CAT TRACKING" SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO
APPUCATION OF PAVEMENT STRIPING AND LEGENDS. NOTIFY THE CITY AT LEAST TWO DAYS PRIOR
FOR APPROVAL OF "CAT TRACKING."
9. BLUE RAISED PAVEMENT MARKERS SHALL BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY
STANDARD PLANS.
10. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER.
LEGEND:
REMOVE EXISTING PROPOSED
S' TYPE IV (L or R) PAVEMENT ARROW
I) I' ROADSIDE SIGN
TRAFFIC STRIPE OR MARKING
SIGN LEGEND:
RIGHT LANE
MUST
TURN RIGHT
R3-7 (RT)
W3-3
AUTOCAD FILENAME:
M~AAWMWAWA
Vi4(7U
Y,
DIAL
BEFORE
YOU DIG
TOLL FREE
� I 1/)TWO WORKING
DAYS BEFORE
YOU DIG
1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE
ENCR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
KOA CORPORATION
PLANNING & ENGINEERING
3190 C. Shelby Street
Ontario, Califomia 91764
Tel: (909) 890-9693 Fax: (909) 890-9694
BENCH MARK: B.M. NO. 346 ELEVATION=1040.78'
DESCRIPTION: THE BENCHMARK FOR THIS SURVEY IS CITY OF FONTANA BENCHMARK 346 BEING A
RAIL ROAD SPIKE SET IN POLE FOR STANDARD #740088E, 30FT WEST OF
CENTERLINE BEECH AVE AND 660.1 FT SOUTH OF CENTERLINE SLOVER AVE.
Prepared Under The Supervision Of :
CITY OF FONTANA, CALIFORNIA
TITLE SHEET
DRAWN BY:
DESIGNED BY:
SLOVER AVENUE
AND
BEEn-AVENUE
CHECKED BY:
MING GUAN. R.C.E. 75793
Nt
C EN
DATE:
R R.C.E. 51152
SCALE:
As Noted
DATE:
DRAWING NO.:
5077