HomeMy WebLinkAbout5008-1N r7 0 c o a.)o Lu W 0 ow 6 v r, 0 0 - N a v t p. a r-� %a. r` 0 o0 1a GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 3. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 4. CURVE DATA REFERS TO THE FACE OF CURB. 5. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 6. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO THE PAVING OF STREETS. 7. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 811 TWO WORKING DAYS BEFORE EXCAVATION. 8. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 9. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL COMPANIES INCLUDING, BUT NOT LIMITED TO GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL, AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 10. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 11. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE DETERMINED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 12. WHEN CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 13. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 14. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 15. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 16. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPVOVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 17. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES FIVE (5) FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 18. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 23. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 25. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 26. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 27. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. 28. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 29. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 30. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT PRIOR APPROVAL OF THE INSPECTOR 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 33. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE "W.A.T.C.H. MANUAL", LATEST EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 35. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. - 36. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 37. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. PRIVATE ENGINEERING NOTE: CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR SITE CON- DIT1ONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. THE PRIVATE ENGINEER SIGNING THESE PLANS IS RESPONSIBLE FOR ACCURACY AND ACCEPTABILITY OF THE DESIGN HEREON, IN THE EVENT OF DISCREPANCIES ARISING AFTER COUNTY APPROVAL OR DURING CONSTRUCTION, THE PRIVATE ENGINEER SHALL BE RESPONSIBLE FOR DETERMINING AN ACCEPTABLE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY THE COUNTY. STREET PLANS CITY OF FONTANA PHILADELPHIA AVENUE CITY OF FONTANA EXISTING DEVELOPMENT COUNTY LINE STREET . 11.11,11,11 n L) 1 F=.I s.� A.S.P. 12-023 /, t \ \ / i1 v:; rz‘ \ \ i •� sr r% 1,5,4N 8E8 PHILADELPHIA ----f- --. 'vx.::, j::�11YYrlltl`,w.;n�v.,.e EXISTING DEVELOPMENT ;I2/NO COUNTY R/VERS_/DE COUNTY CITY OF JURUPA VALLEY EXISTING R/W S'LY CITY OF JURPA VALLEY 50' •»'4 VA 13 T -• INDEX MAP SCALE: 1"=100' COUNTY/CITY LINE STREET . 50 100 Oso : 200 W � z Q 300 400 CITY OF FONTANA 52' SCALE: 1 INCH = 100 FEET PROPOSED R/W N'LY r 12' 6' 6' 38' EXISTING CONC. SIDEWALK 40' TRIM EDGE FOR SMOOTH JOINT PROPOSED A.C. PAVING AND BASE 12' 5.5' EXISTING A.C. PAVING AND BASE (2.0%) 2.0% OWNER/APPLICANT TUFFU COMPANY, INC. 2780 SKYPARK DRIVE, SUITE 100 TORRANCE, CA 90505 PHONE: (310) 326-8460 CONTACT: WILLIAM CUNNINGHAM CIVIL ENGINEER KCT CONSULTANTS, INC. 4344 LATHAM STREET, SUITE 200 RIVERSIDE, CA 92501 PHONE: (951) 341-8940 FAX: (951) 341-8945 CONTACT: TERRY TABIOLO TOPO SOURCE INLAND AERIAL SURVEYS, INC. 7117 ARUNGTON AVE., SUITE A RIVERSIDE, CA 92503 PHONE: (951) 687-4252 Underground Service Alert call: TOLL FREE 1-800 227-2600 TWO WORKING DAYS BEFORE YOU DIG PROPOSED 8" CURB AND GUTTER EXISTING 8" CURB AND GUTTER0 TYPICAL STREET SECTION -PHILADELPHIA AVENUE TRAFFIC INDEX = 9 / CITY OF FONTANA STD. DWG. 400 SOILS ENGINEER NORCAL ENGINEERING SOILS AND GEOTECHNICAL CONSULTANTS 10641 HUMBOLT STREET LOS ALAMITOS, CA 90720 PHONE: (562) 799-9469 FAX: (562) 799-9459 CONTACT: SCOTT SPENSIERO PROJECT NO.: 13757-07 DATE: JUNE 18, 2007 KCT CONSULTANTS, INC. CMI Engineers - Surveyors - Planners P.O. Box 5705 Riverside, CA 92517-5705 4344 Latham St., Suite 200, Riverside, CA 92501 Phone: 951-341-8940 Fax: 951-341-8945 e-mail: kctinc@kctconsultants.com W.O.: 1077-03 BASIS OF BEARING: CONCRETE SIDEWALK BASIS OF BEARINGS: BEARINGS ARE BASED ON THE CENTERLINE OF INDUSTRY AVENUE AS SHOWN BY MAP OF PARCEL MAP NO. 4409, ON FILE IN BOOK 40 OF PARCEL MAPS, PAGES 41 THEREOF, RECORDS OF SAN BERNARDINO COUNTY, CALIFORNIA, BEING N.00'07'36"E. BENCHMARK:, CITY OF FONTANA B.M. # 603 ELEVATION = 861.84 TOP OF FIRE HYDRANT ® THE SOUTHEAST CORNER OF INDUSTRY AVENUE AND UNION AVENUE. SHEET INDEX SHEET 1 SHEETS 2 SHEETS 3-4 SHEETS 5 t- AND LOCAL DEPRESSION PER CITY OF FONTANA STD". DWG. 3003 "CASE A". J j ...../J'" %j•' -..,y J -...,u J'•. ., •/ -, . .: d. 1 `--'..//% •:...!^' i +J '^.,.,wso•/�''•..,,:d/�..`-ww.t��'--,..�,..,.•.e;�i'-•v,...r✓� '-• .,:,w-;. ,. �js�`-,,,,,Ng� ..y..wlj% `',,.,,ri;..pry �,'-. ,.....�:•i` '•:.,.: n• f- •-..:..[.. 10 INSTALL 16,000 LUMEN STREET LIGHT PER CITY OF FONTANA STD. DWG. 404. 11 CONSTRUCT JUNCTION PER FONTANA STD. DWG. 3010. SEE PROFILE ON SHEET 2. TITLE SHEET PLAN & PROFILE STREET SECTIONS EROSION CONTROL PLAN JURUPA AVE. ›-CITY W Li cc L`OF � o OF o ONTARIO Lu COUNTY SAN BERNARDINO CITY OF FONTANA Q r COUNTY OF RIVERSIDE Philad Inland Iphia Avenue Ave�, o • Hopkins . co q) �° --5 . CITY OF JURPA VALLEY STATE HHiy s FRE�AY MAP - _ ii\ t2gcotetv OrAwiv4V7 6-P41NT -6- Qi REVISED CATCH BASIN TYPE AND CONST. NOTE 9 8/5/13 TNT g.lt.r REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHEET INDEX SHEET 1 SHEETS 2 SHEETS 3-4 SHEETS 5 t- AND LOCAL DEPRESSION PER CITY OF FONTANA STD". DWG. 3003 "CASE A". J j ...../J'" %j•' -..,y J -...,u J'•. ., •/ -, . .: d. 1 `--'..//% •:...!^' i +J '^.,.,wso•/�''•..,,:d/�..`-ww.t��'--,..�,..,.•.e;�i'-•v,...r✓� '-• .,:,w-;. ,. �js�`-,,,,,Ng� ..y..wlj% `',,.,,ri;..pry �,'-. ,.....�:•i` '•:.,.: n• f- •-..:..[.. 10 INSTALL 16,000 LUMEN STREET LIGHT PER CITY OF FONTANA STD. DWG. 404. 11 CONSTRUCT JUNCTION PER FONTANA STD. DWG. 3010. SEE PROFILE ON SHEET 2. TITLE SHEET PLAN & PROFILE STREET SECTIONS EROSION CONTROL PLAN CONSTRUCTION NOTES: 0 0 0 0 0 0 PLACE 6.5" A.C. PAVING OVER 12" CLASS II AGGREGATE BASE (TENTATIVE SECTION). SEE GENERAL NOTE #28 CONSTRUCT 8" CONCRETE CURB AND GUTTER PER CITY OF FONTANA STD. DWG. 1000. CONSTRUCT ACCESS RAMP PER CITY OF FONTANA STD. DWG. 1003. CONSTRUCT 6' WIDE BY 4" THICK CONCRETE SIDEWALK. PLACE EXPANSION JOINTS AND WEAKEN PLANE JOINTS PER CITY OF FONTANA STD. DWG. 1006. CONSTRUCT 10' CROSS GUTTER PER CITY OF FONTANA STD. DWG. 403. ADJUST MANHOLE TO GRADE. TRIM EDGE FOR SMOOTH JOINT. 8O PLACE PAVEMENT MARKING FOR TWO-WAY LEFT TURN LANE PER CALTRANS STD. PLAN. A20B, DETAIL 31 CONSTRUCT CATCH BASIN PER CITY OF FONTANA STD. DWG. 3004 (W=7', V=3.5' .j SIGNING AND STRIPING GENERAL NOTES 1. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS. THE STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA AND THE STANDARD SPECIFICATIONS FOR THE STATE OF CALIFORNIA (LATEST NON -METRIC EDITION). 2. PAVEMENT MARKINGS SHALL CONFORM TO THE CITY OF FONTANA STANDARD STENCILS. 3. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC PER SPECIAL PROVISIONS. 4. TRAFFIC SIGN DIMENSIONS COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON ARE TO CONFORM TO CALTRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. 5. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POST, UNLESS OTHERWISE SHOWN, PER CITY STANDARD DETAIL NO. 139. 6. IT SHALL BE THE RESPONSIBILTY OF ' THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OF OTHER TRAFFIC CONTROL AT ALL TIMES. 7. CONTROL POINTS OR "CAT -TRACKING" TO BE APPROVED BY THE ENGINEER 2 WORKING DAYS PRIOR TO PAVEMENT STRIPING APPLICATION. 8. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED BY METHOD AS APPROVED BY THE ENGINEER. UNDERGROUND UTILITY NOTES 1. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL POTHOLE ALL UTILITY CROSSINGS AND CONNECTIONS AND VERIFY THE LOCATION AND ELEVATION OF ALL UTILITIES AFFECTED. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES BEFORE CONSTRUCTION BEGINS. 2. LOCATIONS OF SUBSTRUCTURES AS SHOWN ON PLANS ARE SHOWN FROM THE BEST AVAILABLE INFORMATION. HOWEVER, SUCH LOCATIONS AS SHOWN OR FAILURE TO SHOW EXISTING SUBSTRUCTURES SHALL NOT RELIEVE THE CONTRACTORS FROM THE RESPONSIBILITY OF VERIFYING THE LOCATION AND PROTECTING -ALL SUBSTRUCTURES. 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT AND MAKE NECESSARY ARRANGEMENTS WITH THE APPROPRIATE UTILITY COMPANIES PRIOR TO THE BEGINNING OF CONSTRUCTION. 4. CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT AT LEAST TWO DAYS PRIOR TO CONSTRUCTION. PHONE: 811. F ESS/0 44; w TERESITO N. TABIOLO RCE No. 38826 4 ti‘• rn Im Exp. 3-31-15 CIVIL .�\ OFCA`C"' Prepared Under The Supervision Of : Date : Q TERESITO N. TABIOLO R.C.E. 38826 EXP.3-31-15 COW f1TO N. TPL.O nATE- DESIGN REVISION ELPC13-000023 A.S.P. 12-023 CITY OF FONTANA, CALIFORNIA DESIGN REVIEW ELPC13-000005 DRAWN BY: DESIGNED BY: CHECKED BY: STREET IMPROVEMENT PLANS PHILADELPHIA AVENUE TIT E - E� CITY ENGINEER R. 1152 SCALE: AS SHOWN DATE: JANUARY 2013 DWG. NO.: 5008 JURUPA AVE. ›-CITY W Li cc L`OF � o OF o ONTARIO Lu COUNTY SAN BERNARDINO CITY OF FONTANA Q r COUNTY OF RIVERSIDE Philad Inland Iphia Avenue Ave�, o Hopkins co q) �° --5 �� VICINITY CITY OF JURPA VALLEY STATE HHiy s FRE�AY MAP Street p N.T.S. CONSTRUCTION NOTES: 0 0 0 0 0 0 PLACE 6.5" A.C. PAVING OVER 12" CLASS II AGGREGATE BASE (TENTATIVE SECTION). SEE GENERAL NOTE #28 CONSTRUCT 8" CONCRETE CURB AND GUTTER PER CITY OF FONTANA STD. DWG. 1000. CONSTRUCT ACCESS RAMP PER CITY OF FONTANA STD. DWG. 1003. CONSTRUCT 6' WIDE BY 4" THICK CONCRETE SIDEWALK. PLACE EXPANSION JOINTS AND WEAKEN PLANE JOINTS PER CITY OF FONTANA STD. DWG. 1006. CONSTRUCT 10' CROSS GUTTER PER CITY OF FONTANA STD. DWG. 403. ADJUST MANHOLE TO GRADE. TRIM EDGE FOR SMOOTH JOINT. 8O PLACE PAVEMENT MARKING FOR TWO-WAY LEFT TURN LANE PER CALTRANS STD. PLAN. A20B, DETAIL 31 CONSTRUCT CATCH BASIN PER CITY OF FONTANA STD. DWG. 3004 (W=7', V=3.5' .j SIGNING AND STRIPING GENERAL NOTES 1. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS. THE STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA AND THE STANDARD SPECIFICATIONS FOR THE STATE OF CALIFORNIA (LATEST NON -METRIC EDITION). 2. PAVEMENT MARKINGS SHALL CONFORM TO THE CITY OF FONTANA STANDARD STENCILS. 3. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC PER SPECIAL PROVISIONS. 4. TRAFFIC SIGN DIMENSIONS COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON ARE TO CONFORM TO CALTRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. 5. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POST, UNLESS OTHERWISE SHOWN, PER CITY STANDARD DETAIL NO. 139. 6. IT SHALL BE THE RESPONSIBILTY OF ' THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OF OTHER TRAFFIC CONTROL AT ALL TIMES. 7. CONTROL POINTS OR "CAT -TRACKING" TO BE APPROVED BY THE ENGINEER 2 WORKING DAYS PRIOR TO PAVEMENT STRIPING APPLICATION. 8. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED BY METHOD AS APPROVED BY THE ENGINEER. UNDERGROUND UTILITY NOTES 1. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL POTHOLE ALL UTILITY CROSSINGS AND CONNECTIONS AND VERIFY THE LOCATION AND ELEVATION OF ALL UTILITIES AFFECTED. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES BEFORE CONSTRUCTION BEGINS. 2. LOCATIONS OF SUBSTRUCTURES AS SHOWN ON PLANS ARE SHOWN FROM THE BEST AVAILABLE INFORMATION. HOWEVER, SUCH LOCATIONS AS SHOWN OR FAILURE TO SHOW EXISTING SUBSTRUCTURES SHALL NOT RELIEVE THE CONTRACTORS FROM THE RESPONSIBILITY OF VERIFYING THE LOCATION AND PROTECTING -ALL SUBSTRUCTURES. 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT AND MAKE NECESSARY ARRANGEMENTS WITH THE APPROPRIATE UTILITY COMPANIES PRIOR TO THE BEGINNING OF CONSTRUCTION. 4. CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT AT LEAST TWO DAYS PRIOR TO CONSTRUCTION. PHONE: 811. F ESS/0 44; w TERESITO N. TABIOLO RCE No. 38826 4 ti‘• rn Im Exp. 3-31-15 CIVIL .�\ OFCA`C"' Prepared Under The Supervision Of : Date : Q TERESITO N. TABIOLO R.C.E. 38826 EXP.3-31-15 COW f1TO N. TPL.O nATE- DESIGN REVISION ELPC13-000023 A.S.P. 12-023 CITY OF FONTANA, CALIFORNIA DESIGN REVIEW ELPC13-000005 DRAWN BY: DESIGNED BY: CHECKED BY: STREET IMPROVEMENT PLANS PHILADELPHIA AVENUE TIT E - E� CITY ENGINEER R. 1152 SCALE: AS SHOWN DATE: JANUARY 2013 DWG. NO.: 5008