HomeMy WebLinkAbout5075-6ckyD
METAL STAKES
(SEE NOTE 3)
IPS FLEXIBLE HOSE
(USE 795 CEMENT)
PVC TEE (TYP)
PVC HEADER
SUPPLY
MANIFOLD
METAL STAKES
(SEE NOTE 3)
PVC ELL TO
COMPRESSION
ADAPTER (TYP)
AIR VACUUM REUEF
VALVE & VALVE
BOX AT HIGHEST
POINTS
NOTES:
COMPRESSION
CROSS
1. SEE IRRIGATION NOTES,LEGEND/SPECIFICATIONS FOR ALL DIMENSIONS
AND LATERAL AND INLINE SPACING
2. ALL FITTINGS TO BE USED WILL BE PER MANUFACTURERS
SPECIFICATIONS. USE COMPRESSION FITTINGS ONLY OR APPROVED
EQUAL
3. BURY DRIPUNE 2" BELOW GRADE AND STAKE EACH DRIPLINE AT 4'
O.C. OR AS NECESSARY TO INSURE SECURITY
2. ALL TREES ARE TO BE PLANTED WITHIN CENTER OF DRIP LINE RUNS.
KEEP DRIP LINE A MINIMUM OF 2' AWAY FROM TREE TRUNK.
5. INSTALL CHECK VALVES AT 6' ELEVATION CHANGE INTERVALS (TYP)
XERIGATION CONTROL ZONE KIT
PVC SCH 40 ELL
PVC SCH 80 NIPPLE (TYPICAL,
LENGTH AS REQUIRED)
30 -INCH UNEAR LENGTH
OF WIRE, COILED
WATER PROOF CONNECTION:
RAIN BIRD SPLICE -1
(1 OF 2)
VALVE BOX WITH COVER
STAMP VALVE # ON COVER PER DETAIL 8, L4
ID TAG: RAIN BIRD VID SERIES
TOP OF MULCI
FINISH GRADE
CONTROL ZONE KIT: RAIN BIRD XCZ-10000M
(INCLUDES: FPT BALL VALVE,
RBY 100C LSS FILTER, 100PESB VALVE,
PSI-M40X-100 PRESSURE REGULATOR)
PVC LATERAL
PVC SCH 40 MALE ADAPTER
PVC SCH 80 NIPPLE, CLOSE (1 OF 3)
PVC SCH 80 UNION FOR
SERVICING ASSEMBLY
PVC MAINUN
3 -INCH MINIMUM DEPTH OF
3/4 -INCH WASHED GRAVEL
BRICK (1 OF 4
PVC SCH 80 NIPPLE (2 -INCH
LENGTH, HIDDEN) AND
PVC SCH 40 ELL
PVC SCH 40 TEE OR ELL
Call Underground Service Alert
c
at least 2 days
before you dig
Know what's below.
CaII before you dig.
CONTROL ZONE KIT
PLIN7 //A,
.W/////
ELBOW //\
'/N/
(CA) COMPRESSION �`��/
ADAPTER
,„////
IPX FLEX HOSE
(USE 795 CEMENT)
PVC TEE (TYP)
(SxSxS)
1
1
1
1
1
1
1
1
1
1
1
1 I 1
1 ,.• 1
1
1
1
1
1
1
1
PVC PIPING
ZONE FLUSH VALVE
PLUMBED TO PVC (TYP)
(SEE DETAIL)
METAL STAKE (TYP)
(SEE NOTE 3)
BURY DRIPUNE 2" BELOW FINISH GRADE
(LE. TOP OF SOIL) FOR TURF AREAS.
FOR SHRUB AREAS BURY 2" BELOW
FINISH GRADE THEN ADD 2'-3" OF BARK
MULCH ON TOP. (TYP.)
TRIANGULATE EMITTER SPACING (TYP)
(SEE NOTE BELOW FOR LATERAL AND
IN UNE SPACING)
DRIPUNE LATERAL
(OR EQUAL) SEE LEGEND/
SPECIFICATIONS FOR LATERAL
AND IN UNE SPACING
AREA PERIMETER
PERIMETER LATERALS - 12* FROM
PAVING OR EDGE OF TREATMENT
AIR RELIEF LATERAL - BLANK
DRIPUNE (OR EQUAL)
(CENTERED ON MOUND OR BERM)
AIR/VACUUM RELIEF VALVE
PLUMBED TO DRIPUNE
(OR EQUAL) AT EACH HIGH POINT
(SEE DETAIL)
CHECK VALVES AS NECESSARY (TYP)
(SEE NOTE 5)
PVC SUPPLY MANIFOLD
SUPPLY MANIFOLD
CONNECTION (PVC TO TEE)
(OR EQUAL)
DRIP REMOTE CONTROL VALVE
(SEE DETAIL)
TOP OF MULCH
7 -INCH ROUND VALVE BOX:
AIR RELIEF VALVE KIT:
RAIN BIRD X17000
AR VALVE KIT
LANDSCAPE DRIPUNE TUBING:
(SEE LEGEND FOR TYPE)
PVC LATERAL PIPE
SEE LEGEND
NOTE:
PLACE ALL AIR RELIEF ASSEMBLY
AT HIGHEST SPOT IN THE FIELD FOR
EACH SYSTEM.
3 -INCH MINIMUM DEPTH OF
3/4 -INCH WASHED GRAVEL
AIR RELIEF VALVE
n//
/ . DRIPUNE /�/�
'//%/4/%11fr
(CT) TES \//��/��%\/
://*Foc,,/LilE/
PVC TEE (TYP)
(SxSxS)
1
1 /1
1 I' -K
1
X
1 1
•
INS
PVC PIPING
IPS FLEX HOSE
(USE 795 CEMENT)
ZONE FLUSH VALVE
PLUMBED TO PVC (TYP)
(SEE DETAIL)
•
1
1
1
1
1
1
DRIPLINE SPACING NOTE:
DRIPUNE LATERALS WITHIN TURF AREAS
ARE TO BE SPACED AT 12" O.C.
DRIPUNE LATERALS WITHIN
SHRUB/GRA CLOVER AREAS ARE TO
BE SPACED AT 18" O.C.
0 7" IRRIGATION BOX
OFINISH GRADE OR
MULCH
0 1/2" DRIP LATERAL
UNE
OFLUSH VALVE
RAINBIRD MDCF CAP/
MDCF COUP
O PEA GRAVEL
METAL STAKE (TYP)
(SEE NOTE 3)
72.
TRIANGULATE EMITTER SPACING (TYP)
(SEE NOTE BELOW FOR LATERAL AND
IN UNE SPACING)
CHECK VALVES AS NECESSARY (TYP)
(SEE NOTE 5)
PVC SUPPLY MANIFOLD
DRIP REMOTE CONTROL VALVE
(SEE DETAIL)
SUPPLY MANIFOLD
CONNECTION (PVC TO TEE)
(OR EQUAL)
DRIPUNE LATERAL
(OR EQUAL) SEE LEGEND/
SPECIFICATIONS FOR LATERAL
AND IN LINE SPACING
AREA PERIMETER
AIR REUEF LATERAL - BLANK
DRIPLINE (OR EQUAL)
(CENTERED ON MOUND OR BERM)
PERIMETER LATERALS - 12" FROM
PAVING OR EDGE OF TREATMENT
AIR/VACUUM REUEF VALVE
PLUMBED TO DRIPUNE
(OR EQUAL) AT EACH HIGH POINT
(SEE DETAIL)
FLUSH VALVE ASSEMBLY
STEP 1
0
RED
• BLACK
• WHITE
• BLUE
IRGATION CONTROLLER
PLASTIC VALVE BOX (CARSON OR
EOUAL) WITH PLASTIC INTEGRATED
LOCKING LID. PLACE AT GRADE IN
TURF AREAS AND 3" ABOVE IN
PLANT BED.
PIG TAIL EXPANSION
LOOP (MIN.24" LONG)
RED
BLACK
EPDXY FILLED WATERPROOF
CONNECTOR OR EQUAL
WATERPROOF ALL
WIRE CONNECTIONS
FLOW METER
DIAMETER SAME SIZE
AS FLOW METER SIZE
DIAMETER SAME
SIZE AS FLOW
METER SSE
MINIMUM DISTANCE UPSTREAM OF
UNINTERRUPTED PIPE (10X DIAMETER
OF FLOW METER SIZE)
PIG TAIL EXPANSION
LOOP (MIN.24" LONG)
MASTER CONTROL
VALVE
MINIMUM DISTANCE DOWNSTREAM OF
UNINTERRUPTED PIPE (5X DIAMETER
OF FLOW METER SIZE)
FLOW METER
APPROVED VALVE BOX RAINBIRD ID TAG: NUMBERED
TO MATCH DRAWINGS
REMOTE CONTROL VALVE
PVC SCH. 80
NIPPLE & UNION.
PVC MALE ADAPTER
FINISH GRADE
12" MAX.
PVC LATERAL UNE
ANGLE TO SPECIFIED DEPTH
WITH 45 -DEGREE ELBOWS
SIZE PER DRAWINGS
APPROVED WATERPROOF
CONNECTORS
EXPANSION LOOP
PVC SC.40 ELBOW
TURF AREAS
SHRUB AR
tI•I 1 F `i``•�` �Ir
�o••a�, . dap.•.
PEA GRAVEL
(MIN. 3 CU. FT.) L'1
7
PVC SCH. 80 NIPPLE,
LENGTH AS REOUIRED
TYP. TWO PLACES.
PRESSURE MAIN UNE
PVC SCH. 40 TEE OR
ELBOW
18" MIN.
L
BRICK, ONE AT EACH
CORNER OF VALVE BOX
CONTROL AND COMMON
WIRES. TAPE WIRES TO
MAIN UNE
NOTES:
1. INSTALL CONTROL AND VALVES MINIMUM 2' APART, 2' FROM
STRUCTURES OR HARDSCAPE IN SHRUB AREAS.
2. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALUE BOX.
3. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES.
4. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO
DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD
REDUCE -BUSHING TO BRING PIPING DIAMETER TO REMOTE CONTROL
VALVE SIZE. REFER TO IRRIGATION CONSTRUCTION DOCUMENTS FOR
PIPING SIZE.
REMOTE CONTROL VALVE
STEP 4
1. SLIP BASE SOCKET OVER ENDS OF WIRES.
2. STRIP WIRES APPROX. 3/8" FROM ENDS -
TWIST TOGETHER.
3. PUT CRIMP SLEEVE OVER WIRE ENDS -
CRIMP AND CUT OFF EXCESS WIRE.
4. APPLY SEALER TO OUTSIDE OF SEALING
PLUG - FILL CAVITY WITH SEALER.
5. PULL BASE SOCKET OVER CRIMPED CON-
NECTION AS FAR AS POSSIBLE.
6. PUSH SEALING PLUG INTO BASE SOCKET.
7. PUSH WIRES TO END OF BASE SOCKET
TO ASSURE COMPLETE SEALING OF
CONNECTION.
8. RAIN BIRD "SNAP-T1TE" WIRE CONNECTOR
OR APPROVED EQUAL.
WIRE CONNECTOR
IRRIGATION LEGEND
SYMBOL MFG.
B
•
b
b
0O
v
V
v
0
MODEL NO.
H UNTER RZWS-SLEEVE-36-50-CV
HUNTER PROS-12-PRS40-CV-MPI000-90-210
HUNTER PROS -12-P RS40-CV-MP 1000-90-210
HUNTER PROS-12-PRS40-CV-MPI000-360
H UNTER PROS -12-P RS40-CV-MP2000-90-210
HUNTER PROS-I2-PRS40-CV-MP2000-90-210
HUNTER PROS-12-PRS40-CV-MP2000-360
HUNTER PROS -12-P RS40-CV-MP3000-90-210
HUNTER PROS -12-P RS40-CV-MP3000-90-210
HUNTER P ROS -12-P RS40-CV-M P3000-360
HUNTER PROS-06-PRS40-CV-MPI000-90-210
HUNTER PROS-06-PRS40-CV-MP1000-90.210
HUNTER P ROS -06-P RS40-CV-M P 1000-360
HUNTER PROS-06-PRS40-CV-MP2000-90-210
HUNTER PROS-06-PRS40-CV-MP2000-90-210
HUNTER PROS-06-PRS40-CV-MP2000-360
HUNTER PROS-06-PRS40-CV-MP3000-90-210
HUNTER PROS-06-PRS40-CV-MP3000-90-210
HUNTER PROS-06-PRS40-CV-MP3000-360
DESCRIPTON RAD. GPM PSI
TREE ROOT BUBBLER .50 30
QUARTER SPRAY HEAD
HALF SPRAY HEAD
FULL SPRAY HEAD
QUARTER SPRAY HEAD
HALF SPRAY HEAD
FULL SPRAY HEAD
QUARTER SPRAY HEAD
HALF SPRAY HEAD
FULL SPRAY HEAD
QUARTER SPRAY HEAD
HALF SPRAY HEAD
FULL SPRAY HEAD
QUARTER SPRAY HEAD
HALF SPRAY HEAD
FULL SPRAY HEAD
QUARTER SPRAY HEAD
HALF SPRAY HEAD
FULL SPRAY HEAD
11'-15'
11'-15'
11'-15'
17'-21'
17'-21'
17'-21'
25'-30'
25'-30'
25'-30'
.19
.37
.75
.40
.74
1.47
.86
1.82
3.64
11'-15' .19
11'-15' .37
11'-15' .7
17'-21' .40
17'-21' .74
17'-21' 1.47
25'-30' .85
25'-30' 1.82
25'-30' 3.64
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
MP ROTATOR NOTES:
- WHEN SPRAY RADIUS IS BELOW 90 DEGREES, CONTRACTOR TO SUBSTITUTE ADJUSTABLE
'MPCorner' NOZZLE
RAINBIRD XFS-06-12 DRIP LINE SYSTEM
RAINBIRD XFS-06-18 DRIP LINE SYSTEM
Q RAINBIRD FLUSH VALVE ASSEMBLY - SEE DETAIL
® RAINBIRDAIR RELIEF VALVE - SEE DETAIL
❑M
0
Per 100s f0.
.5 30
er 100s.f.
THE CONTRACTOR WILL NEED TO FIELD LOCATE THE AIR RELIEF VALVES AT
THE HIGHEST LOCATIONS ON EACH DRIP LINE SYSTEM.
FLUSH VALVES ARE TO BE INSTALLED AT THE END POINT OF ALL DRIP LINE SYSTEMS.
RAINBIRD EFB-CP-R-PRS-D SERIES REMOTE CONTROL VALVE W/ PRESSURE
REGULATOR- SIZES INDICATED
RAIN BIRD 33 DLRC LOCKING W/ RUBBER CAP, QUICK COUPLER.
NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2")/T-580-70-66 (2-3/4"-3")
4" AND LARGER TO BE FEBCO NRS SERIES GATE VALVE - LINE SIZE.
WATER METERS - REFER TO CIVIL PLAN
FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER W/ 2" WYE -STRAINER
- SEE DETAILS
AUTOMATIC CONTROLLER LOCATION - SEE NOTE.
'DATA INDUSTRIAL' - HFSM-150 FLOW SENSOR
2 1/2" GRISWORLD 2230 ( NORMALLY CLOSED) MASTER VALVE. INSTALL
DOWNSTREAM FROM FLOW SENSOR.
- FOR VALVES USING 0.2-4 GPM, USE RAINBIRD XCZ-LF-100-PRF CONTROL ZONE KIT -
® REMOTE CONTROL VALVE FOR DRIP SYSTEMS.
- FOR VALVES USING 4-20 GPM, USE RAINBIRD XCZ-100-PRB-COM CONTROL ZONE KIT -
REMOTE CONTROL VALVE FOR DRIP SYSTEMS.
PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS, 24" COVER UNDER PAVING.
- SIZES INDICATED.
HARDSCAPING(SEE NOTE 4)
MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED.
Mainlines (pressurized) 11/2 inch and smaller shall be SchedUT 40 solvent -weld P.V.C.
Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C.
CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE ,
PVC SCH 40 WIRE SLEEVE.
- PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE
- SLEEVES UNDER HARDSCAPE (CONCRETE / ASPHALT IN EXCESS OF 4' WIDE).
NOTE :
* ALL CONTROL WIRE, LATERAL AND MAINLINE PIPE RUNS
TO BE INSTALLED IN SEPERATE SLEEVES.
* ALL SLEEVING TO BE SCH. 40 PVC.
* SIZING :
- WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM
FOR FUTURE WIRE ADDITIONS OR REPAIRS.
- PIPE SLEEVING TO BE 2 x DIAMETER OF PIPE ENCASED.
4 ,.44
CLEAN BACKFILL - SEE
SPECS. FOR MATERIAL.
90% COMPACTION REQUIRED
PROVIDE 6' MIN. OF SAND
BEDDING AND SHADDING
CONTROL WIRE SLEEVE -
I SIZE PER PLAN INSTALL
II1:-TI
- ADJACENT TO PRESSURE
I SUPPLY LINE
:III- PRESSURE SUPPLY LINE
�I I I- SLEEVE - SIZE TWICE
IIIII ( SUPPLY LINE OF PRESSURE
-
NON-PRESSURE LATERAL
UNE SLEEVE - SIZE TWICE
DIAMETER OF NON -PRESSURE
LATERAL UNE
II III III -1 I
NOTES:
1. ALL SLEEVES TO BE SCH 40 PVC.
2. EXTEND ALL SLEEVES 12" BEYOND EDGE OF HARDSCAPING AT BOTH ENDS.
3. ROUTE SLEEVING AROUND HANDICAP RAMPS.
4. PIPING UNDER PAVEMENT SUSCEPTIBLE TO TRAFFIC LOADS REFER TO CITY
STANDARDS. (24" MIN. TO 36" MAX DEPTH TO TOP OF PIPE BELOW
HARDSCAPE SURFACE.
TYPICAL SLEEVING
INDICATES WATER REQUIREMENT
INDICATES STATION NUMBER
INDICATES CONTROLLER
INDICATES GPM
INDICATES VALVE SIZE
INDICATES HYDROZONE AREA
CITY OF FONTANA
IRRIGATION CONTROLLER STANDARD
FOR COMMUNITY FACILITIES DISTRICTS
(CFD'S)
Toro Sentinal controller installed in approved stainless
steel Edison meter box enclosure.
Contact Aqua Flo with the following numbers for the City
of Fontana meter/controller.
Fontana part # for a 36 station controller
ESB3 6-U2-MPEA 1610K -OB 1 -VRA
Fontana part # for a 48 station controller
ESB48-U2-MPEA 1610K -OB 1 -VRA
Available through AQUA FLO
Primary Contact:
Corey Raden (craden@aquaflo.com)
Phone (661) 257-0909
Fax (661) 257-9500
Secondary Contacts:
Renee Erlenbach (rrlenbach@aquaflo.com)
Greg Fax (gfay@aquaflo.com)
Sharon Fay Allen - President - Aqua -Flo Supply
(805) 967-1938
CITY OF FONTANA
LANDSCAPE PLANS
DRAWN 9T,
DESIGNED DTI
CHECKED DYE
SIERRA CREST - PARK SITE 'A'
IRRIGATION DETAILS
& L END
APPaovED r - 44-1d4
SCALD
AS SHOWN
DATE'
DIG. NCr
5075
6
6
SITESCAPES
Landscape Architecture
and Planning
3190-E2 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polhamus, License CA -f2782
(949) 644-9370 (714) 210-3140 FAX
NO.
REVISION
6-4-14 REVISE TOT LOT EQUIP.,
TREWS AND BENCH NODE
.A
n
i
PARK SITE 'A', TRACT 18 820
1156 N. Mountain Avenue
Upland, California 91786
(909) 985-0971
CONTENTS
z
cc
LSPC 13 -000021
DATE 5-19-14
JOS * 10-031
L5
of 17