Loading...
HomeMy WebLinkAbout5075-6ckyD METAL STAKES (SEE NOTE 3) IPS FLEXIBLE HOSE (USE 795 CEMENT) PVC TEE (TYP) PVC HEADER SUPPLY MANIFOLD METAL STAKES (SEE NOTE 3) PVC ELL TO COMPRESSION ADAPTER (TYP) AIR VACUUM REUEF VALVE & VALVE BOX AT HIGHEST POINTS NOTES: COMPRESSION CROSS 1. SEE IRRIGATION NOTES,LEGEND/SPECIFICATIONS FOR ALL DIMENSIONS AND LATERAL AND INLINE SPACING 2. ALL FITTINGS TO BE USED WILL BE PER MANUFACTURERS SPECIFICATIONS. USE COMPRESSION FITTINGS ONLY OR APPROVED EQUAL 3. BURY DRIPUNE 2" BELOW GRADE AND STAKE EACH DRIPLINE AT 4' O.C. OR AS NECESSARY TO INSURE SECURITY 2. ALL TREES ARE TO BE PLANTED WITHIN CENTER OF DRIP LINE RUNS. KEEP DRIP LINE A MINIMUM OF 2' AWAY FROM TREE TRUNK. 5. INSTALL CHECK VALVES AT 6' ELEVATION CHANGE INTERVALS (TYP) XERIGATION CONTROL ZONE KIT PVC SCH 40 ELL PVC SCH 80 NIPPLE (TYPICAL, LENGTH AS REQUIRED) 30 -INCH UNEAR LENGTH OF WIRE, COILED WATER PROOF CONNECTION: RAIN BIRD SPLICE -1 (1 OF 2) VALVE BOX WITH COVER STAMP VALVE # ON COVER PER DETAIL 8, L4 ID TAG: RAIN BIRD VID SERIES TOP OF MULCI FINISH GRADE CONTROL ZONE KIT: RAIN BIRD XCZ-10000M (INCLUDES: FPT BALL VALVE, RBY 100C LSS FILTER, 100PESB VALVE, PSI-M40X-100 PRESSURE REGULATOR) PVC LATERAL PVC SCH 40 MALE ADAPTER PVC SCH 80 NIPPLE, CLOSE (1 OF 3) PVC SCH 80 UNION FOR SERVICING ASSEMBLY PVC MAINUN 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL BRICK (1 OF 4 PVC SCH 80 NIPPLE (2 -INCH LENGTH, HIDDEN) AND PVC SCH 40 ELL PVC SCH 40 TEE OR ELL Call Underground Service Alert c at least 2 days before you dig Know what's below. CaII before you dig. CONTROL ZONE KIT PLIN7 //A, .W///// ELBOW //\ '/N/ (CA) COMPRESSION �`��/ ADAPTER ,„//// IPX FLEX HOSE (USE 795 CEMENT) PVC TEE (TYP) (SxSxS) 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 ,.• 1 1 1 1 1 1 1 1 PVC PIPING ZONE FLUSH VALVE PLUMBED TO PVC (TYP) (SEE DETAIL) METAL STAKE (TYP) (SEE NOTE 3) BURY DRIPUNE 2" BELOW FINISH GRADE (LE. TOP OF SOIL) FOR TURF AREAS. FOR SHRUB AREAS BURY 2" BELOW FINISH GRADE THEN ADD 2'-3" OF BARK MULCH ON TOP. (TYP.) TRIANGULATE EMITTER SPACING (TYP) (SEE NOTE BELOW FOR LATERAL AND IN UNE SPACING) DRIPUNE LATERAL (OR EQUAL) SEE LEGEND/ SPECIFICATIONS FOR LATERAL AND IN UNE SPACING AREA PERIMETER PERIMETER LATERALS - 12* FROM PAVING OR EDGE OF TREATMENT AIR RELIEF LATERAL - BLANK DRIPUNE (OR EQUAL) (CENTERED ON MOUND OR BERM) AIR/VACUUM RELIEF VALVE PLUMBED TO DRIPUNE (OR EQUAL) AT EACH HIGH POINT (SEE DETAIL) CHECK VALVES AS NECESSARY (TYP) (SEE NOTE 5) PVC SUPPLY MANIFOLD SUPPLY MANIFOLD CONNECTION (PVC TO TEE) (OR EQUAL) DRIP REMOTE CONTROL VALVE (SEE DETAIL) TOP OF MULCH 7 -INCH ROUND VALVE BOX: AIR RELIEF VALVE KIT: RAIN BIRD X17000 AR VALVE KIT LANDSCAPE DRIPUNE TUBING: (SEE LEGEND FOR TYPE) PVC LATERAL PIPE SEE LEGEND NOTE: PLACE ALL AIR RELIEF ASSEMBLY AT HIGHEST SPOT IN THE FIELD FOR EACH SYSTEM. 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL AIR RELIEF VALVE n// / . DRIPUNE /�/� '//%/4/%11fr (CT) TES \//��/��%\/ ://*Foc,,/LilE/ PVC TEE (TYP) (SxSxS) 1 1 /1 1 I' -K 1 X 1 1 • INS PVC PIPING IPS FLEX HOSE (USE 795 CEMENT) ZONE FLUSH VALVE PLUMBED TO PVC (TYP) (SEE DETAIL) • 1 1 1 1 1 1 DRIPLINE SPACING NOTE: DRIPUNE LATERALS WITHIN TURF AREAS ARE TO BE SPACED AT 12" O.C. DRIPUNE LATERALS WITHIN SHRUB/GRA CLOVER AREAS ARE TO BE SPACED AT 18" O.C. 0 7" IRRIGATION BOX OFINISH GRADE OR MULCH 0 1/2" DRIP LATERAL UNE OFLUSH VALVE RAINBIRD MDCF CAP/ MDCF COUP O PEA GRAVEL METAL STAKE (TYP) (SEE NOTE 3) 72. TRIANGULATE EMITTER SPACING (TYP) (SEE NOTE BELOW FOR LATERAL AND IN UNE SPACING) CHECK VALVES AS NECESSARY (TYP) (SEE NOTE 5) PVC SUPPLY MANIFOLD DRIP REMOTE CONTROL VALVE (SEE DETAIL) SUPPLY MANIFOLD CONNECTION (PVC TO TEE) (OR EQUAL) DRIPUNE LATERAL (OR EQUAL) SEE LEGEND/ SPECIFICATIONS FOR LATERAL AND IN LINE SPACING AREA PERIMETER AIR REUEF LATERAL - BLANK DRIPLINE (OR EQUAL) (CENTERED ON MOUND OR BERM) PERIMETER LATERALS - 12" FROM PAVING OR EDGE OF TREATMENT AIR/VACUUM REUEF VALVE PLUMBED TO DRIPUNE (OR EQUAL) AT EACH HIGH POINT (SEE DETAIL) FLUSH VALVE ASSEMBLY STEP 1 0 RED • BLACK • WHITE • BLUE IRGATION CONTROLLER PLASTIC VALVE BOX (CARSON OR EOUAL) WITH PLASTIC INTEGRATED LOCKING LID. PLACE AT GRADE IN TURF AREAS AND 3" ABOVE IN PLANT BED. PIG TAIL EXPANSION LOOP (MIN.24" LONG) RED BLACK EPDXY FILLED WATERPROOF CONNECTOR OR EQUAL WATERPROOF ALL WIRE CONNECTIONS FLOW METER DIAMETER SAME SIZE AS FLOW METER SIZE DIAMETER SAME SIZE AS FLOW METER SSE MINIMUM DISTANCE UPSTREAM OF UNINTERRUPTED PIPE (10X DIAMETER OF FLOW METER SIZE) PIG TAIL EXPANSION LOOP (MIN.24" LONG) MASTER CONTROL VALVE MINIMUM DISTANCE DOWNSTREAM OF UNINTERRUPTED PIPE (5X DIAMETER OF FLOW METER SIZE) FLOW METER APPROVED VALVE BOX RAINBIRD ID TAG: NUMBERED TO MATCH DRAWINGS REMOTE CONTROL VALVE PVC SCH. 80 NIPPLE & UNION. PVC MALE ADAPTER FINISH GRADE 12" MAX. PVC LATERAL UNE ANGLE TO SPECIFIED DEPTH WITH 45 -DEGREE ELBOWS SIZE PER DRAWINGS APPROVED WATERPROOF CONNECTORS EXPANSION LOOP PVC SC.40 ELBOW TURF AREAS SHRUB AR tI•I 1 F `i``•�` �Ir �o••a�, . dap.•. PEA GRAVEL (MIN. 3 CU. FT.) L'1 7 PVC SCH. 80 NIPPLE, LENGTH AS REOUIRED TYP. TWO PLACES. PRESSURE MAIN UNE PVC SCH. 40 TEE OR ELBOW 18" MIN. L BRICK, ONE AT EACH CORNER OF VALVE BOX CONTROL AND COMMON WIRES. TAPE WIRES TO MAIN UNE NOTES: 1. INSTALL CONTROL AND VALVES MINIMUM 2' APART, 2' FROM STRUCTURES OR HARDSCAPE IN SHRUB AREAS. 2. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALUE BOX. 3. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. 4. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD REDUCE -BUSHING TO BRING PIPING DIAMETER TO REMOTE CONTROL VALVE SIZE. REFER TO IRRIGATION CONSTRUCTION DOCUMENTS FOR PIPING SIZE. REMOTE CONTROL VALVE STEP 4 1. SLIP BASE SOCKET OVER ENDS OF WIRES. 2. STRIP WIRES APPROX. 3/8" FROM ENDS - TWIST TOGETHER. 3. PUT CRIMP SLEEVE OVER WIRE ENDS - CRIMP AND CUT OFF EXCESS WIRE. 4. APPLY SEALER TO OUTSIDE OF SEALING PLUG - FILL CAVITY WITH SEALER. 5. PULL BASE SOCKET OVER CRIMPED CON- NECTION AS FAR AS POSSIBLE. 6. PUSH SEALING PLUG INTO BASE SOCKET. 7. PUSH WIRES TO END OF BASE SOCKET TO ASSURE COMPLETE SEALING OF CONNECTION. 8. RAIN BIRD "SNAP-T1TE" WIRE CONNECTOR OR APPROVED EQUAL. WIRE CONNECTOR IRRIGATION LEGEND SYMBOL MFG. B • b b 0O v V v 0 MODEL NO. H UNTER RZWS-SLEEVE-36-50-CV HUNTER PROS-12-PRS40-CV-MPI000-90-210 HUNTER PROS -12-P RS40-CV-MP 1000-90-210 HUNTER PROS-12-PRS40-CV-MPI000-360 H UNTER PROS -12-P RS40-CV-MP2000-90-210 HUNTER PROS-I2-PRS40-CV-MP2000-90-210 HUNTER PROS-12-PRS40-CV-MP2000-360 HUNTER PROS -12-P RS40-CV-MP3000-90-210 HUNTER PROS -12-P RS40-CV-MP3000-90-210 HUNTER P ROS -12-P RS40-CV-M P3000-360 HUNTER PROS-06-PRS40-CV-MPI000-90-210 HUNTER PROS-06-PRS40-CV-MP1000-90.210 HUNTER P ROS -06-P RS40-CV-M P 1000-360 HUNTER PROS-06-PRS40-CV-MP2000-90-210 HUNTER PROS-06-PRS40-CV-MP2000-90-210 HUNTER PROS-06-PRS40-CV-MP2000-360 HUNTER PROS-06-PRS40-CV-MP3000-90-210 HUNTER PROS-06-PRS40-CV-MP3000-90-210 HUNTER PROS-06-PRS40-CV-MP3000-360 DESCRIPTON RAD. GPM PSI TREE ROOT BUBBLER .50 30 QUARTER SPRAY HEAD HALF SPRAY HEAD FULL SPRAY HEAD QUARTER SPRAY HEAD HALF SPRAY HEAD FULL SPRAY HEAD QUARTER SPRAY HEAD HALF SPRAY HEAD FULL SPRAY HEAD QUARTER SPRAY HEAD HALF SPRAY HEAD FULL SPRAY HEAD QUARTER SPRAY HEAD HALF SPRAY HEAD FULL SPRAY HEAD QUARTER SPRAY HEAD HALF SPRAY HEAD FULL SPRAY HEAD 11'-15' 11'-15' 11'-15' 17'-21' 17'-21' 17'-21' 25'-30' 25'-30' 25'-30' .19 .37 .75 .40 .74 1.47 .86 1.82 3.64 11'-15' .19 11'-15' .37 11'-15' .7 17'-21' .40 17'-21' .74 17'-21' 1.47 25'-30' .85 25'-30' 1.82 25'-30' 3.64 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 MP ROTATOR NOTES: - WHEN SPRAY RADIUS IS BELOW 90 DEGREES, CONTRACTOR TO SUBSTITUTE ADJUSTABLE 'MPCorner' NOZZLE RAINBIRD XFS-06-12 DRIP LINE SYSTEM RAINBIRD XFS-06-18 DRIP LINE SYSTEM Q RAINBIRD FLUSH VALVE ASSEMBLY - SEE DETAIL ® RAINBIRDAIR RELIEF VALVE - SEE DETAIL ❑M 0 Per 100s f0. .5 30 er 100s.f. THE CONTRACTOR WILL NEED TO FIELD LOCATE THE AIR RELIEF VALVES AT THE HIGHEST LOCATIONS ON EACH DRIP LINE SYSTEM. FLUSH VALVES ARE TO BE INSTALLED AT THE END POINT OF ALL DRIP LINE SYSTEMS. RAINBIRD EFB-CP-R-PRS-D SERIES REMOTE CONTROL VALVE W/ PRESSURE REGULATOR- SIZES INDICATED RAIN BIRD 33 DLRC LOCKING W/ RUBBER CAP, QUICK COUPLER. NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2")/T-580-70-66 (2-3/4"-3") 4" AND LARGER TO BE FEBCO NRS SERIES GATE VALVE - LINE SIZE. WATER METERS - REFER TO CIVIL PLAN FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER W/ 2" WYE -STRAINER - SEE DETAILS AUTOMATIC CONTROLLER LOCATION - SEE NOTE. 'DATA INDUSTRIAL' - HFSM-150 FLOW SENSOR 2 1/2" GRISWORLD 2230 ( NORMALLY CLOSED) MASTER VALVE. INSTALL DOWNSTREAM FROM FLOW SENSOR. - FOR VALVES USING 0.2-4 GPM, USE RAINBIRD XCZ-LF-100-PRF CONTROL ZONE KIT - ® REMOTE CONTROL VALVE FOR DRIP SYSTEMS. - FOR VALVES USING 4-20 GPM, USE RAINBIRD XCZ-100-PRB-COM CONTROL ZONE KIT - REMOTE CONTROL VALVE FOR DRIP SYSTEMS. PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS, 24" COVER UNDER PAVING. - SIZES INDICATED. HARDSCAPING(SEE NOTE 4) MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED. Mainlines (pressurized) 11/2 inch and smaller shall be SchedUT 40 solvent -weld P.V.C. Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C. CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE , PVC SCH 40 WIRE SLEEVE. - PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE - SLEEVES UNDER HARDSCAPE (CONCRETE / ASPHALT IN EXCESS OF 4' WIDE). NOTE : * ALL CONTROL WIRE, LATERAL AND MAINLINE PIPE RUNS TO BE INSTALLED IN SEPERATE SLEEVES. * ALL SLEEVING TO BE SCH. 40 PVC. * SIZING : - WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM FOR FUTURE WIRE ADDITIONS OR REPAIRS. - PIPE SLEEVING TO BE 2 x DIAMETER OF PIPE ENCASED. 4 ,.44 CLEAN BACKFILL - SEE SPECS. FOR MATERIAL. 90% COMPACTION REQUIRED PROVIDE 6' MIN. OF SAND BEDDING AND SHADDING CONTROL WIRE SLEEVE - I SIZE PER PLAN INSTALL II1:-TI - ADJACENT TO PRESSURE I SUPPLY LINE :III- PRESSURE SUPPLY LINE �I I I- SLEEVE - SIZE TWICE IIIII ( SUPPLY LINE OF PRESSURE - NON-PRESSURE LATERAL UNE SLEEVE - SIZE TWICE DIAMETER OF NON -PRESSURE LATERAL UNE II III III -1 I NOTES: 1. ALL SLEEVES TO BE SCH 40 PVC. 2. EXTEND ALL SLEEVES 12" BEYOND EDGE OF HARDSCAPING AT BOTH ENDS. 3. ROUTE SLEEVING AROUND HANDICAP RAMPS. 4. PIPING UNDER PAVEMENT SUSCEPTIBLE TO TRAFFIC LOADS REFER TO CITY STANDARDS. (24" MIN. TO 36" MAX DEPTH TO TOP OF PIPE BELOW HARDSCAPE SURFACE. TYPICAL SLEEVING INDICATES WATER REQUIREMENT INDICATES STATION NUMBER INDICATES CONTROLLER INDICATES GPM INDICATES VALVE SIZE INDICATES HYDROZONE AREA CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD'S) Toro Sentinal controller installed in approved stainless steel Edison meter box enclosure. Contact Aqua Flo with the following numbers for the City of Fontana meter/controller. Fontana part # for a 36 station controller ESB3 6-U2-MPEA 1610K -OB 1 -VRA Fontana part # for a 48 station controller ESB48-U2-MPEA 1610K -OB 1 -VRA Available through AQUA FLO Primary Contact: Corey Raden (craden@aquaflo.com) Phone (661) 257-0909 Fax (661) 257-9500 Secondary Contacts: Renee Erlenbach (rrlenbach@aquaflo.com) Greg Fax (gfay@aquaflo.com) Sharon Fay Allen - President - Aqua -Flo Supply (805) 967-1938 CITY OF FONTANA LANDSCAPE PLANS DRAWN 9T, DESIGNED DTI CHECKED DYE SIERRA CREST - PARK SITE 'A' IRRIGATION DETAILS & L END APPaovED r - 44-1d4 SCALD AS SHOWN DATE' DIG. NCr 5075 6 6 SITESCAPES Landscape Architecture and Planning 3190-E2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhamus, License CA -f2782 (949) 644-9370 (714) 210-3140 FAX NO. REVISION 6-4-14 REVISE TOT LOT EQUIP., TREWS AND BENCH NODE .A n i PARK SITE 'A', TRACT 18 820 1156 N. Mountain Avenue Upland, California 91786 (909) 985-0971 CONTENTS z cc LSPC 13 -000021 DATE 5-19-14 JOS * 10-031 L5 of 17