HomeMy WebLinkAbout2689-113. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
14. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE DETERMINED
AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA
STANDARD DETAILS.
15. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL ASPHALT PAVEMENT PRIOR TO
PLACING ASPHALT.
16. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE COLOR AND FINISH TO
ALL ADJOINING CURBS AND SIDEWALKS.
17. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE
BEEN PLACED, INSPECTED AND APPROVED.
18. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S
INSPECTOR.
19. THE CONTRACTOR SHALL NOT CAUSE ANY MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO
PUBLIC OR ADJACENT PROPERTY DURING CONSTRUCTION. ANY MUD OR DEBRIS ON
PUBLIC PROPERTY SHALL BE REMOVED IMMEDIATELY. DUST SHALL BE CONTROLLED
BY WATERING OR OTHER APPROVED MEANS.
20. THE SOILS ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION AT INTERVALS
REQUIRED BY THE INSPECTOR. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL
REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY
IS OBTAINED.
21. ALL MATERIALS AND METHODS ARE SUBJECT THE THE APPROVAL OF THE CITY
ENGINEER.
22. ADEQUATE CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONTROL
STAKING DURING CONSTRUCTION.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY
ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES ENTERING OR LEAVING
IMPROVEMENTS.
24. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR
STRUCTURAL STREET SECTION SHALL BE RECOMMENDED BY A GEOTECHNICAL
ENGINEERING REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON
COMPLETION OF ROUGH GRADING.
25. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION
AND APPROVAL OF THE CITY AS REQUIRED BY SOILS TESTS TAKEN AFTER COMPLETION
OF ROUGH GRADING.
26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN EFFECTIVE MEANS OF
DUST CONTROL, WHICH SHALL INCLUDE PROVISIONS FOR ADEQUATE WATERING,
DURING EXCAVATION AND GRADING.
27. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION
OF ALL UNDERGROUND FACILITIES WHETHER SHOWN ON THESE PLANS OR NOT.
28. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL AGENCIES CONCERNED
WITH THE RELOCATION OF FACILITIES LOCATED WITHIN THE AREA TO BE IMPROVED
AND INTERFERING WITH CONSTRUCTION PRIOR TO COMMENCING CONSTRUCTION.
29. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
30. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH
MARKS NOTED ON THE PLANS, OR FOUND DURING CONSTRUCTION WITHOUT PRIOR
NOTIFICATION TO THE CIVIL ENGINEER. REMOVAL AND REPLACEMENT SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS, WHICH WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SO
THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF SAID
MONUMENTS BY SAID REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
VICINITY MAP
N.T.S.
UTILITY PURVEYORS:
ELECTRIC TELEPHONE
SOUTHERN CALIFORNIA EDISON CO. PACIFIC BELL
300 N. PEPPER AVE. 4025 LA PALMA STREET
RIALTO, CA. 92376 ANAHEIM, CA. 92807
UNDERGROUND: (909) 357-6233 (714) 237-6146
TRANSMISSIONS: (909) 875-5100 ATTN: DELIA LERMA
PIPELINES: (213) 657-1233
DISTRIBUTION: (909) 357-6233
GAS
SOUTHERN CALIFORNIA GAS CO.
1981 LUGONIA AVE.
REDLANDS, CA 92374
(909) 335-7744
EMERGENCIES: (800) 427-2200
y�
CITY OF FONTANA
STREET IMPROVEMENT PLANS
FOR
TRACT 15959, & -1
1
r R. All�r_
�f�t .^,r
SHEET 4
CITY OF FONTANA
8353 SIERRA AVE.
FONTANA, CA. 92335
(909) 350-6632
ATTN: CARLOS NAVARRO
CABLE CO.
WATER COMCAST CABLE
CUCAMONGA COUNTY WATER DISTRICT 1205 DUPONT AVE.
9641 SAN BERNARDINO ROAD ONTARIO, CA. 91761
RANCHO CUCAMONGA, CA. 91730 (909) 390-4738
(909) 483-7440
®RECORD DRAWING
The information on this drawing is ofltOW ft0m others and
roust be verified in the field by anyone prior to rise or
construction. HALL & FOREMAN, INC. is not responsible for
underground facility locations or depictions. All above groImd
facilities can be readily seen and verified by the parties that
:ntFnd I,se same.
�c0e RI3 F Sl o
LNgl
y� � e0�
No.
0024573 7D
��F CAI�FD�
Underground Service Alert
o
o roG Call: TOLL FREE
0
1-800
422-4133
TWO WORKING DAYS
BEFORE YOU DIG
SHEET 3
Z
Z
A v
� / ti
/
INDEX MAP
SCALE: 1"=150'
BACK OF
WALK
Y
Z
U W Q
U-)F.H., ST. LIGHT,
SIGN, MISC.
CURB FACE-'
GUTTER LIP
SIDEWALK JOG DETAIL
ilk
THE BEARING SHOWN HEREON ARE
BASED ON THE CENTERLINE OF
BASE LINE AVENUE BEING N89.5841 "W
AS SHOWN ON RECORD OF SURVEY
88/78-83.
ADD NOTE 19, REVISE SHT 4.
REVISE NOTE 17 AND DETAIL, SEE SHT 3
Added �•14tco�� ��aw: L�wf
REVISIONS
N.T.S.
BENCH MARK:
TOP REINFORCING ROD IN FLOOD
CONTROL RETAINING WALL SW COR.
BANANA & FOOTHILL
#67-5
ELEV. 1214.17 9/67
APPROVAL I DATE I APPROVAL I DATE
D
ITEM
SHEET 3
SHEET 2
CONSTRUCTION NOTES & QUANTITIES:
DESCRIPTION
CONST. 4" MIN. A.C. OVER 6" A.B. * FINAL SECTION TO BE DETERMINED AFTER ROUGH GRADING
CONST. 6" CURB & GUTTER PER CITY OF FONTANA STD. DETAIL 101.
CONST. 4" THICK P.C.C. SIDEWALK (W=4.5')
CONST. 6" CURB ONLY PER CITY OF FONTANA STD. DETAIL 101.
CONST. CROSS GUTTER WITH #4 BAR @ 12" O.C. BOTH WAYS IN GUTTER
PORTION. (SIZE PER PLAN)
CONST. ACCESS RAMP PER CITY OF FONTANA STD. DETAIL 104A.
CONST. CURB INLET LOCAL DEPRESSION PER CITY OF FONTANA STD. DETAIL 121.
SAWCUT & REMOVE EXISITING A.C. PAVEMENT
REMOVE EXISTING 8" CURB & GUTTER
RELOCATE EXISTING WATER METER PER C.C.W.D.
REMOVE EXISTING TREES.
CONST. DRIVEWAY APPROACH (MAX. 16') PER CITY OF FONTANA STD. DETAIL 102.
INSTALL 5800 LUMEN COBRAHEAD CUT-OFF LUMINARE, MOUNTED ON A "MARBLE LIGHT"
STANDARD. MOUNTING HEIGHT SHALL BE 25'
CONST. 51/2" A.C. OVER 12" COMPACTED NATIVE SOIL. * FINAL SECTION TO BE
DETERMINED AFTER ROUGH GRADING
REMOVE EXISTING 6" MEDIAN CURB
RELOCATE EXISTING TRAFFIC SIGN
CONST. CURB DRAIN (SINGLE PIPE) PER APWA STD. PLAN 150-2 (SEE DETAIL HEREON)
INSTALL 22,000 LUMEN COBRAHEAD CUT-OFF LUMINARE, MOUNTED ON A "MARBLE LIGHT"
STANDARD. MOUNTING HEIGHT SHALL BE 25'
REMOVE EXISTING STREET LIGHT BY EDISON.
R/W
5' PUBLIC 1 50'
UTILITY
EASEMENT I 7' 1 18' 1 18'
QUANTITY
CITY OF FONTANA GENERAL NOTES
PRIVATE NOTICE TO CONTRACTORS
15959
FOR
_ENGINEER'S
37,100
2,100
STREET IMPROVEMENT PLANS
1. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
11,140
SF
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
250
2
LF
EA
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
1.
ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA
AND PROPERTY. THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
O.C.
STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS
AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THECONTRACTOR
BEGIN CURVE
FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK LATEST EDITION).
SHALL DEFEND, INDEMNIFY, AND HOLD THE AGENCY AND THE
P.R.C.
POINT OF REVERSE CURVE
ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED,
2.
CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
E.V.C.
ENGINEERING DIVISION PRIOR TO START OF ANY WORK. INSPECTION COORDINATION
EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE
MIDDLE OF VERTICAL CURVE
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY
AGENCY OR THE ENGINEER.
S
WORK WITHIN THE CITY LIMITS. CALL (909) 350-7610
3.
THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANTS OR WATER MAIN VALVES.
2. THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE
VALVE OPERATIONS AND WATER REQUIREMENTS.
PLANS. ALL REQUESTED CHANGES TO THE PLANS MUST BE IN WRITING
AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
4.
CURVE DATA REFERS TO THE FACE OF CURB.
5.
STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE
UNDERGROUND UTILITIES & STRUCTURES
NOTED.
-
6.
THE CONTRACTOR SHALL INSTALL PAVEMENT MARKINGS AND STRIPING AS REQUIRED
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
BY THE CITY ENGINEER.
STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
7.
ALL UNDERGROUND WORK SHALL BE COMPLETED, TESTED AND APPROVED PRIOR TO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PAVING OF STREETS.
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR
8.
THE LOCATIONS OF PUBLIC UTILITIES SHOWN HAVE BEEN DETERMINED FROM
ANY DAMAGE TO THESE LINES OR STRUCTURES.
AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE THE TRUE LOCATION AND ELEVATION IN THE FIELD OF
ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTIONS TO AVOID DAMAGE
THERETO. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT FOR UTILITY
LOCATION BEFORE EXCAVATION AT 800-422-4133.
9.
ALL MANHOLES, CLEANOUT FRAMES AND COVERS SHALL BE CONSTRUCTED SIX INCHES
BELOW FINISHED GRADE AND SHALL BE RAISED TO GRADE BY THE PAVING
CONTRACTOR UPON COMPLETION OF PAVING.
w
10. ALL VALVE BOXES AND COVERS SHALL BE CONSTRUCTED SIX INCHES BELOW FINISH
GRADE AND SHALL BE RAISED TO GRADE BY THE PAVING CONTRACTOR UPON
HIGHLAND
AVENUE
5G.
COMPLETION OF PAVING.
C3
C3
a
�
15
vP
w
�
11.
REFER TO CITY OF FONTANA UNDERGROUND UTILITY LOCATION STANDARD DETAIL NO.
U
W
CITY 0
129.
o
S. PAl
RAILROAD
FONTANA
w
w
m
12. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
NE
NUE
a
BASELINE AVENUE
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRICAL,
CITY OF
LIGHTING, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC
RANCHO
}
WATER, RECLAIMED WATER, SEWER, STORM DRAIN, AND FLOOD CONTROL.
AMONGA
CUCM
13. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
14. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE DETERMINED
AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA
STANDARD DETAILS.
15. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL ASPHALT PAVEMENT PRIOR TO
PLACING ASPHALT.
16. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE COLOR AND FINISH TO
ALL ADJOINING CURBS AND SIDEWALKS.
17. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE
BEEN PLACED, INSPECTED AND APPROVED.
18. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S
INSPECTOR.
19. THE CONTRACTOR SHALL NOT CAUSE ANY MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO
PUBLIC OR ADJACENT PROPERTY DURING CONSTRUCTION. ANY MUD OR DEBRIS ON
PUBLIC PROPERTY SHALL BE REMOVED IMMEDIATELY. DUST SHALL BE CONTROLLED
BY WATERING OR OTHER APPROVED MEANS.
20. THE SOILS ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION AT INTERVALS
REQUIRED BY THE INSPECTOR. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL
REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY
IS OBTAINED.
21. ALL MATERIALS AND METHODS ARE SUBJECT THE THE APPROVAL OF THE CITY
ENGINEER.
22. ADEQUATE CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONTROL
STAKING DURING CONSTRUCTION.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY
ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES ENTERING OR LEAVING
IMPROVEMENTS.
24. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR
STRUCTURAL STREET SECTION SHALL BE RECOMMENDED BY A GEOTECHNICAL
ENGINEERING REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON
COMPLETION OF ROUGH GRADING.
25. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION
AND APPROVAL OF THE CITY AS REQUIRED BY SOILS TESTS TAKEN AFTER COMPLETION
OF ROUGH GRADING.
26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN EFFECTIVE MEANS OF
DUST CONTROL, WHICH SHALL INCLUDE PROVISIONS FOR ADEQUATE WATERING,
DURING EXCAVATION AND GRADING.
27. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION
OF ALL UNDERGROUND FACILITIES WHETHER SHOWN ON THESE PLANS OR NOT.
28. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL AGENCIES CONCERNED
WITH THE RELOCATION OF FACILITIES LOCATED WITHIN THE AREA TO BE IMPROVED
AND INTERFERING WITH CONSTRUCTION PRIOR TO COMMENCING CONSTRUCTION.
29. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
30. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH
MARKS NOTED ON THE PLANS, OR FOUND DURING CONSTRUCTION WITHOUT PRIOR
NOTIFICATION TO THE CIVIL ENGINEER. REMOVAL AND REPLACEMENT SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS, WHICH WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SO
THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF SAID
MONUMENTS BY SAID REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
VICINITY MAP
N.T.S.
UTILITY PURVEYORS:
ELECTRIC TELEPHONE
SOUTHERN CALIFORNIA EDISON CO. PACIFIC BELL
300 N. PEPPER AVE. 4025 LA PALMA STREET
RIALTO, CA. 92376 ANAHEIM, CA. 92807
UNDERGROUND: (909) 357-6233 (714) 237-6146
TRANSMISSIONS: (909) 875-5100 ATTN: DELIA LERMA
PIPELINES: (213) 657-1233
DISTRIBUTION: (909) 357-6233
GAS
SOUTHERN CALIFORNIA GAS CO.
1981 LUGONIA AVE.
REDLANDS, CA 92374
(909) 335-7744
EMERGENCIES: (800) 427-2200
y�
CITY OF FONTANA
STREET IMPROVEMENT PLANS
FOR
TRACT 15959, & -1
1
r R. All�r_
�f�t .^,r
SHEET 4
CITY OF FONTANA
8353 SIERRA AVE.
FONTANA, CA. 92335
(909) 350-6632
ATTN: CARLOS NAVARRO
CABLE CO.
WATER COMCAST CABLE
CUCAMONGA COUNTY WATER DISTRICT 1205 DUPONT AVE.
9641 SAN BERNARDINO ROAD ONTARIO, CA. 91761
RANCHO CUCAMONGA, CA. 91730 (909) 390-4738
(909) 483-7440
®RECORD DRAWING
The information on this drawing is ofltOW ft0m others and
roust be verified in the field by anyone prior to rise or
construction. HALL & FOREMAN, INC. is not responsible for
underground facility locations or depictions. All above groImd
facilities can be readily seen and verified by the parties that
:ntFnd I,se same.
�c0e RI3 F Sl o
LNgl
y� � e0�
No.
0024573 7D
��F CAI�FD�
Underground Service Alert
o
o roG Call: TOLL FREE
0
1-800
422-4133
TWO WORKING DAYS
BEFORE YOU DIG
SHEET 3
Z
Z
A v
� / ti
/
INDEX MAP
SCALE: 1"=150'
BACK OF
WALK
Y
Z
U W Q
U-)F.H., ST. LIGHT,
SIGN, MISC.
CURB FACE-'
GUTTER LIP
SIDEWALK JOG DETAIL
ilk
THE BEARING SHOWN HEREON ARE
BASED ON THE CENTERLINE OF
BASE LINE AVENUE BEING N89.5841 "W
AS SHOWN ON RECORD OF SURVEY
88/78-83.
ADD NOTE 19, REVISE SHT 4.
REVISE NOTE 17 AND DETAIL, SEE SHT 3
Added �•14tco�� ��aw: L�wf
REVISIONS
N.T.S.
BENCH MARK:
TOP REINFORCING ROD IN FLOOD
CONTROL RETAINING WALL SW COR.
BANANA & FOOTHILL
#67-5
ELEV. 1214.17 9/67
APPROVAL I DATE I APPROVAL I DATE
D
ITEM
SHEET 3
SHEET 2
CONSTRUCTION NOTES & QUANTITIES:
DESCRIPTION
CONST. 4" MIN. A.C. OVER 6" A.B. * FINAL SECTION TO BE DETERMINED AFTER ROUGH GRADING
CONST. 6" CURB & GUTTER PER CITY OF FONTANA STD. DETAIL 101.
CONST. 4" THICK P.C.C. SIDEWALK (W=4.5')
CONST. 6" CURB ONLY PER CITY OF FONTANA STD. DETAIL 101.
CONST. CROSS GUTTER WITH #4 BAR @ 12" O.C. BOTH WAYS IN GUTTER
PORTION. (SIZE PER PLAN)
CONST. ACCESS RAMP PER CITY OF FONTANA STD. DETAIL 104A.
CONST. CURB INLET LOCAL DEPRESSION PER CITY OF FONTANA STD. DETAIL 121.
SAWCUT & REMOVE EXISITING A.C. PAVEMENT
REMOVE EXISTING 8" CURB & GUTTER
RELOCATE EXISTING WATER METER PER C.C.W.D.
REMOVE EXISTING TREES.
CONST. DRIVEWAY APPROACH (MAX. 16') PER CITY OF FONTANA STD. DETAIL 102.
INSTALL 5800 LUMEN COBRAHEAD CUT-OFF LUMINARE, MOUNTED ON A "MARBLE LIGHT"
STANDARD. MOUNTING HEIGHT SHALL BE 25'
CONST. 51/2" A.C. OVER 12" COMPACTED NATIVE SOIL. * FINAL SECTION TO BE
DETERMINED AFTER ROUGH GRADING
REMOVE EXISTING 6" MEDIAN CURB
RELOCATE EXISTING TRAFFIC SIGN
CONST. CURB DRAIN (SINGLE PIPE) PER APWA STD. PLAN 150-2 (SEE DETAIL HEREON)
INSTALL 22,000 LUMEN COBRAHEAD CUT-OFF LUMINARE, MOUNTED ON A "MARBLE LIGHT"
STANDARD. MOUNTING HEIGHT SHALL BE 25'
REMOVE EXISTING STREET LIGHT BY EDISON.
R/W
5' PUBLIC 1 50'
UTILITY
EASEMENT I 7' 1 18' 1 18'
QUANTITY
4
UNIT
15959
15959-1
46,420
2,300
37,100
2,100
SF
LF
13,200
11,140
SF
125
2
250
2
LF
EA
2#1 5'
I � I
I LEVEL
I LINE 1
+.06' 2% 2% +.06'--,
1:_ ___ -
3 --
J :) ENI -9-4--1 J 2
50' SECTION
N.T.S.
SLOCUM PLACE
MEADE COURT
McCLELLAN COURT
LON GSTREET LANE
SHEET 2
LAI
R/l1 I O21
F
\11' OF
MAX. SLCPE 1:
HINGE COVER AT TOP OF MAME1
RECTANGULAR FRAME ,
INLET PER CASE I, A. OR m I ( I , I
PER STD. PLAN 152
SEE nlorE I :' mm (3'
11 (1
E
--4
1 t �
III LANE , , • •ISO Iltnt (1 T
1 I
4 2,
' CASE I INLET
N-100 mm I C.LTRANSITION STRUCTURE SECTION
SEE NOTES P0'£5 R/W
/ /T/ / f FRAME !i CRAmm .rZIE 0
35 erfra (1-1/2') MIN CLEM //
WALK (SEE NOTE 4 / A4 / SEE NOTE 10
p011 (03) 1 6') / (87 TOP OF CURB UNE - a
CAS Il INLET
DROP INLET CATCH BASIN SECTION
rio. I I
EG I R^r
gE Wa7E z
SEE: � FPRL T71E5 600 1447)
---- J EIPEN [7 iCli PER IROYEMENT
1 CR CRADO4G PIAN .., (f7
I
A wAtx _
dt
SI PLAN CASE III INLET
GIRACIED BITCH SECTION
9,v2 '50 T.c. I"EI�ANSQ1 luNr I I ?Al
rrim dC771T
mm (2-1/ MW (6-) FOR 150 1 E � 6 /-�•L.
00 1 (3 11r) "Cr 200 � (On CF
R� 10 nun (1
PARKWAY WDTN PER YPR0141I0/T PIAN C:EAR 100 mm (41
ZLINE RK
FINISHED PARKWAY !RADE - I Cl PIPES
Pw WALK, 200 mm (ar) Cr - NOTE 4 Z I NOTE: APPLIES TO ANY NUMBER OF P>PESS
175 mm W) OR ��c WAtx. 150 �„�„ (6' Cr -NOTE E:- CURB PROFILE
ween GALV wRE FANG - 1401E 1 0� I 400 mm (8') CLRB FAC£
Ad (P) B . _ 2n ~� I
10 IBM mea11500,11
(t/Z) ---
e SEE INLET DETAILS (5) TOP OF Q
n� (a B ever, mm
pppp EVANSI I Z ANsx
P.SG Gtltte Rk QJTTER C.1. PIPE (4-) .ANT E FL
SEE NOTE D - - -
u --�
\--•GUTTER 10
MATCH EXISTING SECTION A -A 101 (1/z') � DD "m (A-) C.L PF
IIOTE: APPLIES TB ANY NUUII OF PIPES
Z - TOP-OF-QiB LRE S OIAN ON PROM
CURB PROFILE
150 4ean (07 CIS FACE
AMERICAN PUBLIC WORKS ASSOCIATION -SOUTHERN CALIFORNIA CHAPTER
STANDARD PLAN
' CURB DRAIN METRIC
1,� 150-2
'
11107: t00e USE WTH STANDARD SPECIFICATIONS FOR PUBLIC WORKS COINSTRUCTION SHEET 1 OF 2
QRpFESS/0�V
��CO�PRD L eU F
� 9y m
�
No. 24573 rn
•* Exp. 12/31 /01
C1V1\1
�F CA1-SFO
R/W
5 PUBLIC 1
54'
UTILITY i
EASEMENT I i 7' 20' 20'
I 2/ 5l
I � I
LEVEL
LINE
1
+.02' 2% 2% +.02'
ne--------------------------------------------------------------
NOTES
1. IF THE TOE OF SLOPE IS ALLOWED WITHIN THE R/W, INLET CASE I BEGINS
AT THE TOE RATHER THAN THE R/W UNE.
2. FOR OPEN DITCH (CASE INLET III), THE 600 mm (24") EXTENSION BEYOND
THE R/W LINE IS NOT REQUIRED WHEN BACK OF WALK IS 600 mm (24") OR MORE
FROM THE R/W LINE; HOWEVER, PIPE SHALL EXTEND TO R/W LINE.
3. TOP OF INLET STRUCTURE (CASE I AND 11) TO BE FLUSH WITH ADJACENT
SURFACE WHERE PRACTICAL.
4. CONSTRUCT P.C.C. WALK WHEN SPECIFIED ON PLAN. THE CONTRACT PRICE
PAID'FOR P.C.C. WALK ITEM SHALL INCLUDE WALK CONSTRUCTED IN
CONJUNCTION WITH PARKWAY CULVERT.
5. "N" EQUALS NUMBER OF PIPES (MAXIMUM OF THREE) AS SPECIFIED ON PLAN.
6. INLET CASE TO BE SPECIFIED ON IMPROVEMENT OR GRADING PLAN.
7. ANGLE A EQUALS 0% UNLESS OTHERWISE SPECIFIED.
8. TYPE, DIMENSIONS AND ELEVATIONS OF P.C.C. CURB AND GUTTER PER
IMPROVEMENT PLAN.
9. UNLESS OTHERWISE SPECIFIED, FRAME AND GRATE FOR CASE II INLET SHALL BE
GALVANIZED CAST IRON. WEIGHT OF FRAME AND GRATE SHALL BE 36 k9 (80 LBS).
10. AT LOCATIONS MATH LESS THAN 200 mm (8") CURB FACE, USE 152x152-MW9.1xMW9.1
(6x6-10/10 GALVANIZED WIRE FABRIC. WIRE FABRIC SHALL EXTEND
200 mm (8) BEYOND THE EDGE OF CAST IRON PIPES.
11. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT
EXACTLY EQUAL VALUES. IF METRIC UNITS ARE USED, ALL VALUES USED FOR
CONSTRUCTION SHALL BE METRIC VALUES. IF ENGLISH UNITS ARE USED,
ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH VALUES. HOWEVER,
ASTM 615 REINFORCING STEEL MAY BE SUBSTITUTED FOR ASTM 615M STEEL.
0 SPACES O 24 mm15 101
7 BARS O 16 mm (5 0-
2 OUTSIDE BARS O 22 mm (7/8-11
O�£RA11 356 mm {1,-)
�! E
111-E.m ~
I
E E
EEE*_
^+E¢n
o '� m
en0O
U 0�
<
-
O
i%m
N - N
31I AREA 52:
JUUUUUUU E
E r
n
1 330 mm ■ 330 mm (13- x 13-)1
I•, 432 mm x 432 mm (17- . 171
TOP OF GRATE SECTION THRU FRAME
GRATE FOR CASE II INLET 1
LIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER I STANDARD PLAN
METR1c
CURB DRAIN 150SHE202
1111,
1111,11111111111 1�11111
Lei m ,'� :yommgm
54' SECTION
N.T.S.
GRANT WAY
LEGEND:
6
4
EA
-
-
EA
160
110
1
1,350
110
2
SF
LF
EA
3
-
EA
36
36
EA
7 1 7 1 EA
--
2,100
SF
--
274
LF
--
2
EA
--
1
EA
1
2
EA
--
1
EA
R/W
1 5' PUBLIC
LITY
-79 1 1 EASEMENT
2%
R/W
1 5' PUBLIC
UTILITY
7' i I EASEMENT
5' 21
H.P.
HIGH POINT
T.C.
TOP OF CURB ELEVATION
F.S.
FINISHED SURFACE ELEVATION
F.L.
FLOW LINE ELEVATION
SCALE:
SHEET MATCH LINE
---
TRACT BOUNDARY / PROPERTY LINE
Xx'X
DIRECTION OF FLOW
DESIGNED BY
EXISTING SPOT ELEVATION
G.B.
GRADE BREAK
O.C.
ON CURB
B.C.
BEGIN CURVE
E.C.
END OF CURVE
P.R.C.
POINT OF REVERSE CURVE
P.C.C.
POINT OF COMPOUND CURVE
B.V.C.
BEGIN VERTICAL CURVE
E.V.C.
END OF VERTICAL CURVE
M.V.C.
MIDDLE OF VERTICAL CURVE
W
WATER LINE
S
SEWER LINE
CITY OF FONTANA, CALIFORNIA
In
0
DRAWN BYSTREET
IMPROVEMENT PLANS
SCALE:
o�
HORIZ: NO SCALE
VERT: NO SCALE
6�
ONI
DESIGNED BY
-
TITLE SHEET
TRACT NO. 15959 & Wl
r ---w
�
DATE:
1/18/ss
CHECKED BY
CY)�
JOB NO.
PR. NO.
SHT. NO.
�
5195
APPROVED
�'.r'�i.1l� ITY ENGINEER R.C.E. No. 51152 2689
1 OF 4
li
0=