HomeMy WebLinkAbout2560-1GENERAL NOTES:
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS DATED 1975
INCLUDING LATEST REVISIONS, AND STANDARD SPECIFICATIONS FOR PUBLIC
WORK CONSTRUCTION, 1994 EDITION.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY FONTANA
ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK WITHIN THE
CITY LIMITS. ALL 1146PEC -/0145 SHALL BE 12rQUES TED AT LEAST 24 HOV RS P121Olz
TO THE 67'AZT OFAtiJY WOt2l< AT (909) 350-lp&32 .
3. UNLESS OTHERWISE SPECIFIED, SANITARY SEWER LINES SHALL BE CONSTRUCTED
OF BELL AND SPIGOT TYPE VITRIFIED CLAY PIPE (V.C.P.). VITRIFIED CLAY
PIPE SHALL BE EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS
OF THE ASTM, DESIGNATION : C700-89 "STANDARD SPECIFICATION FOR
VITRIFIED CLAY PIPE: EXTRA STRENGTH, STANDARD STRENGTH, AND PERFORATED"
AND TO THE SPECIFICATIONS ENTITLED "VITRIFIED CLAY PIPE, MATERIALS
SECTION" PUBLISHED BY THE CLAY PIPE INSTITUTE. WHERE PROVISIONS OF
THESE SPECIFICATIONS ARE IN CONFLICT, THE MORE RESTRICTIVE PROVISION
SHALL APPLY.
4. THE MANHOLES SHALL BE PRECAST CONCRETE MANHOLES PER CITY OF FONTANA
STANDARD DETAIL 112. CONCRETE FOR BASE SLAB SHALL BE CLASS 560-B-3250.
STANDARD MANHOLE FRAME AND COVER AND REINFORCED CONCRETE COLLAR TO BE
PER CITY OF FONTANA STANDARD DETAIL 109.
5. ALL STATIONING REFERS TO CENTERLINE SEWER UNLESS OTHERWISE NOTED.
"TOP OF MANHOLE" ARE APPROXIMATE ONLY
6. ELEVATIONS SHOWN ON PROFILE AS
AND NOT TO BE USED FOR SETTING MANHOLE RING.
7. MANHOLE FRAMES AND COVERS SHALL BE CONSTRUCTED BY THE SEWER
CONTRACTOR 6" BELOW FINISHED SURFACE GRADE AND UPON COMPLETION OF
PAVING, THE PAVING CONTRACTOR SHALL RAISE SAME TO FINISHED GRADE.
B. SHORT STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT THE
MANHOLE WALLS TO ABSORB MINIMAL DEFLECTION.
9. 4" V.C.P. HOUSE SEWER LATERALS AND LATERAL HOUSE CLEANOUT ARE TO BE
PER CITY OF FONTANA STANDARD DETAIL 125.
TERMINATE ALL HOUSE SEWER LATERALS 3' INSIDE THE PROPERTY LINE WITH
A PLUG, PER CITY STANDARD DETAIL 125.
10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES.
11. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR
POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES,
ETC., SHOWN ON THESE PLANS OR NOT, WITHIN THE AREA TO BE IMPROVED
AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY OTHERS.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL AGENCIES
CONCERNED BEFORE CONSTRUCTION BEGINS.
12. "AS -BUILT" PLANS SHALL BE PROVIDED TO THE ENGINEER OF RECORD BY THE
CONTRACTOR. THE ENGINEER OF RECORD SHALL PROVIDE "RECORD DRAWINGS"
TO THE CITY PRIOR TO THE CITY'S ACCEPTANCE OF THE SEWER SYSTEM.
13. SEWER CONTRACTOR SHALL CHISEL "X" IN THE CURB AT THE LOCATION OF ALL
LATERALS.
14. THE CONTRACTOR SHALL PROVIDE THE TERMINAL CLEANOUT AT THA END OF THE
BOUNDARY IF THE SEWER CONSTRUCTION WILL BE DONE IN SEVERAL PHASES.
SEE CITY OF FONTANA STANDARD DETAIL 126 FOR SEWER TERMINAL CLEANOUT.
15. ALL 4" HOUSE SEWER LATERAL SHALL BE INSTALLED ON A 2% MINIMUM GRADE
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN EFFECTIVE MEANS
OF DUST CONTROL WHICH SHALL INCLUDE PROVISIONS FOR ADEQUATE WATERING
DURING THE GRADING PROCESS AND PROVISIONS FOR CONTINUANCE OF DUST
CONTROL AFTER THE GRADING UNTIL SUCH TIME THAT THE GRADED SURFACE
PRESENTS EFFICIENT PROTECTIVE COVER AGAINST WIND OR WATER EROSION
THAT SPECIAL DUST CONTROL MEASURES ARE NO LONGER NECESSARY.
17. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH
MARKS NOTED ON THE PLANS OR FOUND DURING CONSTRUCTION WITHOUT PRIOR
NOTIFICATION TO THE CIVIL ENGINEER. REMOVAL AND REPLACEMENT SHALL
BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS WHICH WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. CONTRACTOR SHALL NOTIFY REGISTERED
CIVIL ENGINEER OR LICENSED LAND SURVEYOR ONE WEEK PRIOR TO CONSTRUCTION
SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT
OF SAID MONUMENTS BY SAID REGISTERED CIVIL ENGINEER OR LICENSED LAND
SURVEYOR.
18. CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA PACIFIC BELL CO.
ATTN: CARLOS NAVARRO ATTN: VIRGINIA BECKER _
8353 SIERRA AVENUE 3939 E.CORONADO STREET
FONTANA, CA 92335 ANAHEIM, CA 92807
(909) 350-6632 (714) 666-5467
SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV)
ATTN: DENNIS FREEMAN ATTN: JACK HAYES
1981 W. LUGONIA AVENUE 1205 DUPONT AVENUE
REDLANDS, CA 92374 ONTARIO, CA 91761
(909) 335-7547 (909) 390-4738
EMERGENCIES: (800) 427-2200
GENERAL TELEPHONE COMPANY
SO. CALIFORNIA EDISON COMPANY ATTN: STEVE HOCK
300 N. PEPPER AVENUE 1400 E. PHILLIPS BLVD.
RIALTO, CA 92376 ONTARIO, CA 91766
(909) 820-5598 - UNDERGROUND (800) 422-4133
(909) 875-5100 - TRANSMISSIONS
(213) 637-1233 - PIPELINES FONTANA WATER COMPANY
(909) 357-6233 - DISTRIBUTION ATTN: MICHAEL J. McGRAW
(800) 422-4133 8440 NUEVO AVENUE _
FONTANA, CA 92335
CRAWFORD CANYON MUTUAL WATER CO. (909) 822-2201
ATTN: BILL VANOERKIEFT, JR. FAX: (909) 823-5046
(619) 868-6040
UNDERGROUND SERVICE ALERT
(800) 422-4133
19. THE WALLS AND FACES OF ALL EXCAVATION GREATER THAN FIVE (5) FEET IN
DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF
THE GROUND, OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5)
FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES
HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED.
20. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION
OR TRENCH WORK AS DESCRIBED IN NOTE #19 ABOVE FROM CAL/OHSA.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS;
TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT
THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON-
SIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT
SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS-
IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;
AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER
AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
3" MAX SIZE NATIVE
SOIL,- COMPACTED 95X
6" MIN.
1 MAX.
6" MAX SIZE NATIVE N
SOIL, COMPACTED 9OX
8" VCP
6" MIN.
10" MAX.
10 MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90%
'
N 32
.n
TYPICAL EDDI
8" VCP
LESS THAN 10' DEEP .
3" MAX SIZE NATIVE
SOIL, COMPACTED 95X
6" MIN. 6" MIN.
10 wMAX. 10 MAX.
N
6" MAX SIZE NATIVE
SOIL. COMPACTED 9OX
1" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90X
.• •. • ' I A
�..► = Z
1120 CRUSHED •� �� TABLE 200- 1.2(A)
STONE BEDDING ,�> '' a ci , '
PER STD. SPECS. + c; IL o
FOR PUBLIC WORKS
CONSTRUCTION
TABLE 200-1.2(A) `
it"a8" VCP
TYPICAL BEDDING
811VCP
10' OR DEEPER
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
1 1/2
—
CONSTRUCT 8"
V.C.P. SEWER.
3 4"
100
1/2w
90-100
3 e'
Z0-60
NO.4 1
0-15
NO.8
0-5
TEGRADM G
9
INDEX MAP
CONSTRUCTION
NOTES:
QUANTITIES:
10
CONSTRUCT 8"
V.C.P. SEWER.
3� 940 L•P
O2
CONSTRUCT 4'
V.C.P. SEWER LATERAL PER CITY OF FONTANA
— 2, 2¢5 L•=
STD. DWG. NO.
125.
O3
CONSTRUCT PRECAST
CONCRETE MANHOLE PER CITY OF FONTANA
— /5 �A-
STD. DWG. NO.
112.
O4
REMOVE PLUG
& JOIN EXISTING PIPE.
l '
RECORD DRAWING
THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN
-at- PART, ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED. -INTO THE DOCUMENTS AS
A RESULT THEREOF
CITY ENGINEER R.C.E. 25126
-uD.v CFWFD TTTI F qPT TIS IR7nq-7 - a 1 rn PPis�1 PF- 1n.Fin 7F;Fi n:�-nPr-q7 OF- 51 PM / 126-1050-1
Olt/C. ,DATE: D 1-' 14 — 96