HomeMy WebLinkAbout2514-1GENERAL NOTES:
1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO.THESE
PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS,
PUBLIC WORKS DEPARTMENT, CITY OF FONTANA AND STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK), LATEST EDITION.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA ENGINEERING
DIVISION PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. ALL
INSPECTIONS SHALL BE REQUESTED THROUGH THE CITY OF FONTANA ENGINEERING
DIVISION AT LEAST 24 HOURS PRIOR TO THE START OF ANY WORK AT
(909) 350-6632.
3. STATIONING REFERS TO THE CENTERLINES OF STORM DRAINS EXCEPT WHERE
OTHERWISE NOTED.
4. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND
FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. COLOR,
AND
NO CONCRETE SHALL BE PLACED UNTILL THE FORMS AND REINFORCING STEEL
HAS BEEN PLACED, INSPECTED AND APPROVED.
6. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS.
7. EXISTING UNDERGROUND UTILITIES ARE PER AVAILABLE RECORDS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION
IN THE FIELD.
B. THE WALLS AND FACES OF EXCAVATIONS GREATER THAN FIVE (5) FEET IN
DEPTH SHALL BE --EFFECTIVELY GUARDED BY A SHORING•SYSTEM, SLOPING
OF THE GROUND.OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE
(5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES
HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED.
9. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION
OR TRENCH WORK AS DESCRIBED IN NOTE 8 ABOVE FROM CAL/OSHA.
10. ALL MANHOLES SHALL BE CONSTRUCTED 6" BELOW PAVEMENT GRADE AND BROUGHT
TO FINISHED GRADE BY THE PAVING CONTRACTOR AFTER PAVEMENT IS IN PLACE.
11. IMMEDIATELY FOLOWING REMOVAL OF EXISTING PAVEMENT OR DIKE OR CURB
AND/OR GUTTER, THE CONTRACTOR SHALL DILIGENTLY PURSUE THAT PORTION
OF THE WORK TO COMPLETION.
12. ALL C.M.P.. INSTALLATION AND CONNECTIONS SHALL BE MADE PER MANUFAC-
TURER'S SUGGESTED METHOD UNLESS- OTHERWISE SPECIFIED ON THE PLANS.
13. -IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A SYSTEM
APPROVED -BY THE CITY ENGINEER SHALL BE INSTALLED TO DEWATER SAID
AREA AT•=THE*DIRECTION OF THE SOILS ENGINEER.
14. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF
THE CITY INSPECTOR.
15. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN ACCORDANCE WITH
THE CITY STANDARD SPECIFICATIONS.
16. "AS -BUILT" PLANS SHALL -BE'.. PROVIDED TO THE ENGINEER OF RECORD BY
THE CONTRACTOR. THE ENGINEER OF RECORD SHALL PROVIDE,"RECORD
DRAWING"" TO THE CITY PRIOR TO CITY ACCEPTANCE OF THE.STORM DRAIN
SYSTEM.
18,..C,ITY OF FONTANA UTILITY NOTIFICATION LIST
CITY'OF FONTANA PACIFIC BELL CO.
ATTN: .CARLOS NAVARRO ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE 3939 E.CORONADO STREET
FONTANA, CA 92335 ANAHEIM, CA 92807
(909) 350-6632 - (714) 666-5467
S0. CALIFORNIA GAS COMPANY COMCAST (CABLE TV)
ATTN: DENNIS FREEMAN ; ATTN:- JACK HAYES
1981 W. LUGONIA AVENUE 1205 DUPONT AVENUE
REDLANDS,--'CA 92374 ONTARIO, CA 91761
(909) 335-7547 (909) 390-4738
EMERGENCIES: (800) 427-2200
GENERAL TELEPHONE COMPANY
SO. CALIFORNIA EDISON COMPANY ATTN: STEVE HOCK
300 N. PEPPER AVENUE 1400 E. PHILLIPS BLVD.
RIALTO, CA 92376 ONTARIO, CA 91766
(909) 820-5598 - UNDERGROUND (800) 422-4133
(909) B75-5100 - TRANSMISSIONS
(213).637-1233 - PIPELINES FONTANA WATER COMPANY
(909) 357-6233 - DISTRIBUTION ATTN: MICHAEL J. McGRAW
(800)1..422.-4133.. 8440 NUEVO AVENUE
FONTANA, CA 92335
CRAWFORD CANYON MUTUAL WATER CO. (909) 822-2201
ATTN: BILL VANDERKIEFT, JR. FAX: (909) 823-5046
(619) 868-6040
UNDERGROUND SERVICE ALERT
(800) 422-4133
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS;
TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT
THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON-
SIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT
SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME. -SOLE AND COMPLETE RESPONS-
IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;
AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER
AND THE ENGINEER HARMLESS FROM --ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS 'AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
J
9
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN.
10 MAX.
N
r--
6" MAX SIZE NATIVE
SOIL, COMPACTED 90R
r r : .r�•�
•s
V .t
Y n i
6" MIN.
10" MAX.
1 " MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90%
Z
N Km
W 0
CL
FL O
PROPOSED RCP-/ I I
STORM DRAIN
TYPICAL BEDDING FOR
.R.C.P. STORM DRAIN
Underground Service Alert
CALL
TOLL FREE
1-800
422-4133
TWO WORKING'DAYS BEFORE YOU DIG
PLANS PREPARED FOR
LEWIS HOMES OF CALIFORNIA
ATTN : Ms. MIMI RAYL
1156 N. MOUNTAIN AVENUE
P.O. BOX 670
UPLAND, .CA 91786
PHONE: (909) 985-0971
REVISIONS
W
`Milo�
- - A
2li
INDEX MAP
00
CONSTRUCTION
r
QUANTITIES:
BASIS OF BEARINGS:
Ol.
INSTALL 48" DIA. R.C.P. D = PER PLAN.
711
I
r
•
137 6
I
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS;
TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT
THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON-
SIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT
SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME. -SOLE AND COMPLETE RESPONS-
IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;
AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER
AND THE ENGINEER HARMLESS FROM --ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS 'AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
J
9
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN.
10 MAX.
N
r--
6" MAX SIZE NATIVE
SOIL, COMPACTED 90R
r r : .r�•�
•s
V .t
Y n i
6" MIN.
10" MAX.
1 " MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90%
Z
N Km
W 0
CL
FL O
PROPOSED RCP-/ I I
STORM DRAIN
TYPICAL BEDDING FOR
.R.C.P. STORM DRAIN
Underground Service Alert
CALL
TOLL FREE
1-800
422-4133
TWO WORKING'DAYS BEFORE YOU DIG
PLANS PREPARED FOR
LEWIS HOMES OF CALIFORNIA
ATTN : Ms. MIMI RAYL
1156 N. MOUNTAIN AVENUE
P.O. BOX 670
UPLAND, .CA 91786
PHONE: (909) 985-0971
REVISIONS
W
`Milo�
- - A
2li
INDEX MAP
00
CONSTRUCTION
NOTES: ,
QUANTITIES:
BASIS OF BEARINGS:
Ol.
INSTALL 48" DIA. R.C.P. D = PER PLAN.
711
I
2O.
INSTALL 36" DIA. R.C.P. D = PER PLAN.
137 6
L.r
O3.
INSTALL 27" DIA. R.C.P. D = PER PLAN.
4.3
L .F
G•
INSTALL 24" DIA. R.C.P. D = PER PLAN.
SO.
CONSTRUCT CATCH BASIN PER APWA STD. PLAN 300-1,
W= 9/1 1
BiA
W & V PER PLAN. SEE DETAIL ON SHT. 4..
ELEVATION: 1365.01
6O.
CONSTRUCT MANHOLE PER APWA STD. PLAN 320-0.
/
E .
SEE DETAIL ON SHEET 4.
00071QlJGT JuAcrloN' ,5jRUCT�/RE PE'R APWA STO.
/
XA ,
--
-
pLhN 331--1. 5EE XrAIL --
DESIGNED:
8O•
CONSTRUCT MANHOLE PER APWA STD. PLAN 321-0,
/
94
WITH GRATE MANHOLE COVER SEE DETAIL ON SHEET
0
CONSTRUCT BRICK AND MORTAR PLUG. PLR %OkU 9V.X A9D1A10-
� z^
CHECKED:
CO IJAJ TY r-LO6 D COAD TW L D45rA aT a7V • 176A.
DATE:
AWING
SEE l7Er141L O/V 5HT 4.
RANCHO CUCAMONGA, CA 91730
=E
CRU DRAWING,
THESE RECORD DRAWINGS HAVE BEEN PREPARED. IN
PART, ON .THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT 8E
RESPONSMLE FOR ANY ERRORS OR OMISSIONS V*N M
V Y HAVE BEEN INCORPORATED INTO THE DOGL*WMS �$
A RESULT THEREOF.
BENCH MARK: # 361
SPIKE IN NORTH FACE OFCITY
BASIS OF BEARINGS:
OF FONTANA.'CALIFORNIA
PP #1536697E. @ S•W,
THE C.L.
OF CHERRY AVE. BEING
�
COR. OF BASELINE AVE.
N 000 08'09" E PER P.M. 1959,
.
6 SULTANA AVE.
P.M.B.
28/18 WAS USED AS THE
ELEVATION: 1365.01
BASIS OF BEARINGS FOR THIS PLAN
DRAWN BY:
TRACT NO. 15709-_ 1
SCALE:
PREPARED IN THE OFFICE OF
MADOLE AND ASSOCIATES, INC.
ONSITE STORM DRAIN' PLAN
AS SHOWN
DESIGNED:
OF THE INLAND EMPIRES
�oQw.�TSI��
�
10601 CHURCH STREET STE. 107
� z^
CHECKED:
TITLE SHEET
DATE:
AWING
RANCHO CUCAMONGA, CA 91730
No. i48i4�
PHONE (909) 948-1311
Exp: 3-31-01
- - -
-
sl�lF fIVI1
JOB NO.
Lc1• /-61 9�O?
DWG. NO .
SHEET NO...�
ENGR S DATE CITY
DATE
oQ�ti�
CAL
_
126 1150
APPROVED
2514
CF 6
APPROVAL APPROVAL
J. . MADOLE R.C.E.14814 DATE
CITY ENGINEER R.C.E. 25126
*P*STORM
DRAIN TITLE SHEET - 21 [0, 2551 PF: 1050 862 04-Jun--97H:WPM / 126\-1050-1
DW. DATks �,