HomeMy WebLinkAbout3512-1SEWER IMPROVEMENT NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK," THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY
WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER
TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5
FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED
BY SHORING. SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO.
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS
BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC
WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES
SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF CONSTRUCTION SHALL BE REPLACED. THE
CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM
12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED
ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR
TO WRITTEN APPROVAL
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTJL THE SPECIFIED DENSITY IS
OBTAINED.
22. CARE SHOULD BE TAKEN TO -PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE
SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL
CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF
FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY
PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700
FOR V.C.P.
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY
ENGINEER.
27. SHORT V.C.P. STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR
MINOR DEFLECTIONS IN ALIGNMENT.
4•1
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND
LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE
CITY ENGINEER.
OWNER
IT
IIS`
REGENCY CENTERS
l ),,
555 S. FLOWER ST., STE 3500 JWAV41r4q
LOS ANGELES, CA 90071
s (213) 553-2200 --
,,
'IJ
F Development Resource Cotan* Inc.
a
Civil Engineering • Land Surveying Land Planning
8175 EAST KAISER BOULEVARD
D R
ANAHEIM HILLS, CA 92808 (714) 685-6860
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
CONSTRUCTION DRAWINGS FOR THE
CITY OF FONTANA
SEWER IMPROVEMENT PLANS
1
1
1
n, %
1,
I
LEGEND
REV. LINETYPE
TRACT N0. 16235
A
III
N
f ( p iliPilfiliii�iil �lilitl{ilii!Q � � =�_
TW �I1lli 1111 ��1111,iinn
w i�Tii ilifTll, liil RllilllJ =21-E _
INDEX MAP
SCALES 1'=400`
SEWER IMPROVEMENT NOTES (CONVID'
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND
SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL
TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF
THE SEWER LATERAL
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS,
THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEN PLACED,
INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO
PLACEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
CONSTRUCTION NOTES &QUANTITIES: �'"
ITEM
DESCRIPTION
..QUANTITY
UNIT
TRACT NO.
16235
O
INSTALL 12" EXTRA STRENGTH VCP SEWER MAIN
3180
LF
O
INSTALL 6" SEWER LATERAL PER CITY OF FONTANA STD. DETAIL NO. 125
280
LF
3O
CONSTRUCT SEWER MANHOLE PER CITY OF FONTANA STD. DETAIL NO. 112
21
EA
O4
INSTALL 12"x6" SEWER WYE (LAY WYE FLAT)
13
EA
O
INSTALL 6" SEWER LATERAL PER CITY OF FONTANA STD. DETAIL NO. 125
30
LF
O
INSTALL 5' DIA. SEWER MANHOLE PER CITY OF FONTANA STD. DETAIL NO. 112
1
EA
0
6" BRICK AND MORTAR SEAL
2
EA
I
I
1
I
I
INDEX OF DRAWINGS��-
SHEET NO. DESCRIPTION
1 TITLE
SHEET
DATE ENGR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
2 INDEX MAP
1
PLAN CHECK ISSUE
2/2/0
3 LINE
A STA.
10+00
TO
STA.
20+50
4 LINE
A STA.
20+50
TO
STA.
25+94.71
LINE
B STA.
10+00
TO
STA.
15+00
5 LINE
B STA.
15+00
TO
STA.
26+01.80
A
LEGL DESCRIPTION -
PORTIONS OF THE EAST 1/2 OF THE
SOUTHEAST 1/4 OF SECTION 23, TOWNSHIP 1
NORTH, RANGE 5 WEST AND THE WEST 1/2 OF
THE SOUTHWEST 1/4 OF SECTION 24, TOWNSHIP
1 NORTH, RANGE 6 WEST, SAN BERNARDINO
MERIDIAN, IN THE CITY OF FONTANA, COUNTY
OF SAN BERNARDINO, STATE OF CALIFORNIA
REV.
REVISION DESCRIPTION
DATE ENGR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
QRpFESS/
��41TCy�.�`IYC/
9N
No. 45715
* Exp. 12-31-06
�qL
T CIVI
FOF CP,"\,_
1
PLAN CHECK ISSUE
2/2/0
2
PLAN CHECK ISSUE
2/19/04-"'-
wUj
a
3
TENANT CHANGES
4/12/04
Uj
u,
HIGHLAND
AVENUE
Q
isSAN GABRIEL MOUNTAINS
NORTH
SITE LOCATION moo.
GPS
VICINITY MAP
N.T.S.
CAUTION:
"THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE
FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE
PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
NOTICE TO CONTRACTOR:
UTILITIES SHOWN HEREON AS "PROPOSED" MAY IN FACT BE
EXISTING AT THE TIME OF THIS CONSTRUCTION. THE CONTRACTOR
SHALL DETERMINE IF ANY "FUTURE OR PROPOSED" UTILITY HAS
BEEN CONSTRUCTED.
UNDERGROUND UTILITIES & STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS ARE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE
ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FORM THE SOLE NEGLIGENCE OF THE
OWNER OR THE ENGINEER.
UTILITY PURVEYORS:
ELECTRICITY
SOUTHERN CALIFORNIA EDISON CO.
DISTRIBUTION PLANNING
7951 REDWOOD AVENUE
FONTANA, CA 92335
(909) 357-6240
CONTACT: RON CARDENAS
GAS
SOUTHERN CALIFORNIA GAS CO.
DISTRIBUTION PLANNING
16231 VALLEY BOULEVARD
FONTANA, CA 92335
(909) 428-8407
CONTACT: DAVE PADILLA
WATER
SAN GABRIEL VALLEY WATER COMPANY
11142 GARVEY AVENUE
EL MONTE, CA 91733
(626) 448-6183
CONTACT: S. STEVE GAO
BENCHMARK:
BENCHMARK #8-17 CALTRANS
ELEVATION=1428.6090
BRASS CAP IN CONCRETE S.C.E. TOWER LEG,
343 FEET NORTH OF HIGHLAND AVENUE, 0.20
MILES WEST OF SAN SEVAINE ROAD, 2.65
MILES WEST ALONG HIGHLAND AVENUE, FROM
SIERRA AVENUE.
Prepared Under The Supervision Of :
R.C.E. 45715
DRAWN BY:
AT
DESIGNED BY:
JAM
Date Z f sq�+ CHECKED BY:
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
P.O. BOX 518
FONTANA, CA 92335
(909) 350-7610
OWNER f DEVELOPER
REGENCY REALTY GROUP, INC.
14200 CULVER DRIVE, SUITE S
IRVINE, CA 92604
(949) 726-6000
CONTACT: LARRY G. LARSON
VERIZON CALIFORNIA. INC.
13911 PARK AVENUE
SUITE 200
VICTORVILLE, CA 92392-2407
(760) 245-0330
CONTACT: FRANK AUGUSTAIN
BASIS OF BEARINGS:
THE BEARINGS SHOWN HEREON ARE BASED
ON THE CENTERLINE OF LYTLE CREEK
ROAD BEING N 00040'42" W PER RECORD
OF SURVEY 96-0149 FILED IN BOOK 108,
PAGES 13-28, RECORDS OF THE COUNTY
RECORDER OF SAN BERNARDINO COUNTY.
CITY OF FONTANA, CALIFORNIA
SEWER IMPROVEMENT PLANS
TITLE SHEET
TRI,RCT NO. 16235
a"i1/
LMGCIN Id6f�EE� R.C.E. 51152 DATE:
SCALE:
AS SHOWN
DATE:
2/20/04
DRAWING NO.: 1
3512 5
SUM
AVENUE
o
o
•�P
wUj
a
Y
Uj
u,
HIGHLAND
AVENUE
Q
w
Q
w
U
U)
r
a:
co
w
�
w
=
w
w
U
=
m
U
BASE LINE
ROAD
VICINITY MAP
N.T.S.
CAUTION:
"THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE
FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE
PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
NOTICE TO CONTRACTOR:
UTILITIES SHOWN HEREON AS "PROPOSED" MAY IN FACT BE
EXISTING AT THE TIME OF THIS CONSTRUCTION. THE CONTRACTOR
SHALL DETERMINE IF ANY "FUTURE OR PROPOSED" UTILITY HAS
BEEN CONSTRUCTED.
UNDERGROUND UTILITIES & STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS ARE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE
ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FORM THE SOLE NEGLIGENCE OF THE
OWNER OR THE ENGINEER.
UTILITY PURVEYORS:
ELECTRICITY
SOUTHERN CALIFORNIA EDISON CO.
DISTRIBUTION PLANNING
7951 REDWOOD AVENUE
FONTANA, CA 92335
(909) 357-6240
CONTACT: RON CARDENAS
GAS
SOUTHERN CALIFORNIA GAS CO.
DISTRIBUTION PLANNING
16231 VALLEY BOULEVARD
FONTANA, CA 92335
(909) 428-8407
CONTACT: DAVE PADILLA
WATER
SAN GABRIEL VALLEY WATER COMPANY
11142 GARVEY AVENUE
EL MONTE, CA 91733
(626) 448-6183
CONTACT: S. STEVE GAO
BENCHMARK:
BENCHMARK #8-17 CALTRANS
ELEVATION=1428.6090
BRASS CAP IN CONCRETE S.C.E. TOWER LEG,
343 FEET NORTH OF HIGHLAND AVENUE, 0.20
MILES WEST OF SAN SEVAINE ROAD, 2.65
MILES WEST ALONG HIGHLAND AVENUE, FROM
SIERRA AVENUE.
Prepared Under The Supervision Of :
R.C.E. 45715
DRAWN BY:
AT
DESIGNED BY:
JAM
Date Z f sq�+ CHECKED BY:
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
P.O. BOX 518
FONTANA, CA 92335
(909) 350-7610
OWNER f DEVELOPER
REGENCY REALTY GROUP, INC.
14200 CULVER DRIVE, SUITE S
IRVINE, CA 92604
(949) 726-6000
CONTACT: LARRY G. LARSON
VERIZON CALIFORNIA. INC.
13911 PARK AVENUE
SUITE 200
VICTORVILLE, CA 92392-2407
(760) 245-0330
CONTACT: FRANK AUGUSTAIN
BASIS OF BEARINGS:
THE BEARINGS SHOWN HEREON ARE BASED
ON THE CENTERLINE OF LYTLE CREEK
ROAD BEING N 00040'42" W PER RECORD
OF SURVEY 96-0149 FILED IN BOOK 108,
PAGES 13-28, RECORDS OF THE COUNTY
RECORDER OF SAN BERNARDINO COUNTY.
CITY OF FONTANA, CALIFORNIA
SEWER IMPROVEMENT PLANS
TITLE SHEET
TRI,RCT NO. 16235
a"i1/
LMGCIN Id6f�EE� R.C.E. 51152 DATE:
SCALE:
AS SHOWN
DATE:
2/20/04
DRAWING NO.: 1
3512 5