HomeMy WebLinkAbout2264-1CONDUCTOR SCHEDUL-E SENSOR AW CIRCUITRUN � 2 3 4 NO, 5 6 PHASE 4 8 9 2-N-01 01 2 2-S-02 PHASE 2 3 3 3 3 3 PHASE 8 4 1 02 3 3 3 3 3 3 3 2 14--04 EXP 4 6 01 1-N-01 EXP 1 2 1-S-02 EXP 2 7 3 3 3 2 1-E-08 EXP 8 04 1 3 3 3 3 3 3 26-4-80 30 05 3 1 3 3 1 3 3 1 6 6 1 3 3 D 06 (E 3 3 3 TV -1-T SP -1 -CS 8 07 3 3 3 3 3 3 B 1 2 W 08 SP -1 -CS 1 SIERRA AVE F 3 3 3 #14 02P 2 2 2 2 2 2 2 G 26-4-80 04P 40 15 200 W 1 2 2 1 2 2 2 6 ORANGE WAY 06P 1-A E 2 4 4 2 2 SP -1 -CS OF 2 2 2 2 4 4 2 02 PPB 1 2 2 2 2 2 04 PPB 1 2 2 2 06 PPB 2 2 1 08 PPB 1 1 1 1 1 2 2 1 1 PPB COMMON 1 1 1 1 1 2 2 1 1 SPARES 3 1 3 3 1 3 3 1 6 6 3 3 TOTAL 13 22 25 29 35 55 55 19 10 LUMINAIRE 2 2 2. 2 2 2 2 #10 SIGNAL COMMON 1 1 1 1 1 2 2 1 1 TOTAL 3 3 3 3 3 4 2 3 1 01 2 2 2 2 02 2 2 2 2 04 1 4 4 05 2 2 2 2 DLC 06 2 2 2 2 08 4 4 4 4 4 4 SYSTEM 1 1 1 2 3 4 1 1 TOTAL 5 5 9 10 19 20 5 5 OPTICOM PRE-EMPT 1 1 2 1 2 1 3 4 4 1 CONDUIT SIZE 2" 2" 2" 1 T+,T 1'+3" 2.T+T2-2.5 2" 2" 50.02' I 50.02'MNEWS PHASE DIAGRAM DETECTOR SCHEDULE SENSOR CHANNEL DETECTOR CONTROLLER INPUT 1 1 4-E-�8 PHASE 3 2 24-04 PHASE 4 2 1 2-N-01 PHASE 1 2 2-S-02 PHASE 2 3 1 44-04 PHASE 7 2 2-E-08 PHASE 8 4 1 2-S-05 PHASE 5 2 2-N-06 PHASE 6 5 1 J -E-08 EXP J 2 14--04 EXP 4 6 1 1-N-01 EXP 1 2 1-S-02 EXP 2 7 1 J -W-04 EXP 7 2 1-E-08 EXP 8 8 1 1-S-05 EXP 5 2 1-N-06 EXP 6 PHASE DIAGRAM FUTURE 4 P o— —a 91 92 J013 94 -0 FUTURE 4 b ARMS 2I5 96 .07 .00'8 CB 1-W-4 SYSTEM D 1 1.5, 1 DLC 01 :6:r IU I I 40' 40' I I 3 2' i 3" PVC CONDUIT WITH PULLROPE L 2" C, 2 #6, 1 #8 27C, 4 # 10 2 #12 1 RED, 1 BLACK �T. I * Q \ v 6 o RS LO I I 22 Q ;n 7 4 t 3 _ L — — Lp Agf r4 I I - - N W- lflf— ILTN_ J W— cn. I L � I F- 1 0'TO I cv L J LK C OSSW o u� I — * I 1 TV- 4 I F `J O 3 INSTALL 1.5" CONDUIT WITH 2 #12 CONDUCTORS (1 RED, 1 BLACK) IN TO EXISTING RAILROAD SIGNAL CONTROL CABINET PER THE SPECIAL PROVISIONS, AS DIRECTED BY THE ENGINEER AND PER THE RAIL AUTHORITY REQUIREMENTS. GENERAL NOTES1.. 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTI❑N 86 AND STANDARD PLANS (DATED JULY 1992) 2. LOCATION OF ALL UNDERGROUND UTILITITES ARE APPROXIMATE, THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITI❑NS ON THE JOB SITE, HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS, PHONE UNDERGROUND SERVICE ALERT AT 800/422-4133, 48 HOURS BEFORE DIGGING, 3. ALL PULLBOXES SHALL BE No. 5 AND CONDUIT SHALL BE 2' RIGID METAL EXCEPT AS SHOWN, ALL VEHICLE HEADS SHALL BE METAL WITH ALL 12' GLASS LENSES, AND METAL ONE-PIECE LOUVERED BACKPLATES, ALL NEW RED INDICATIONS SHALL BE L.E.D. PER THE SPECIAL PROVISIONS. 4. C❑ORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED, 5. EXISTING SIGNAL AND LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING ARE OPERATI❑NAL, 6. OBTAIN APPROVAL FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 7, PERFORM STRIPING REVISIONS PRIOR TO LOOP DETECTOR LAYOUT, 8. ALL NEW LOOPS SHALL BE 6' x 6' WITH 10' SPACING IN THE DIRECTION OF TRAVEL AND CENTERED IN THE LANE EXCEPT AS SHOWN. EXTEND LIMIT LINE LOOPS 1' PAST LIMIT LINE, 9, RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 10. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY, D 06 08 I 0 08 05 R73-3- 02 62sl--,T IN E-1-8 H36 �L4J 0 z - z i N (E)=EXISTING EQUIPMENT TO REMAIN SCALE: 1"=20' L J� 180' TO -1 CROSSWALK L J 0,0E12 UI SIERRA AVENUE -$ I CONSTRUCTION SET W.� �o QROFESSlpNq! CLYDE ELWYN SWEET, JR. No. 26690 4L Exp, 3 -3 j_q G �j CIVIL q�F OF1F0�`�`� CAL ^-1'--' Detector Most Arm OPTICAL DETECTOR MOUNTING DETAIL Not to Scale LO to CONSTRUCTION NOTES ❑1 REMOVE AND SALVAGE EXISTING TYPE "M" CONTROLLER ASSEMBLY. INSTALL CITY FURNISHED CONTROLLER ASSEMBLY INCLUDING TYPE 'P' CABINET, TYPE 90 CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED TO PROVIDE THE DESIRED OPERATION, MODIFY EXISTING TYPE 'M' FOUNDATION FOR TYPE 'P' CABINET AS DIRECTED BY THE ENGINEER. 0 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING 120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V UN -METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL CIRCUIT BREAKER, 30 A LIGHTING CIRCUIT BREAKER, PEC FOR LIGHTING IN SERVING UTILITY PORTION OF ENCLOSURE, ❑3 INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M511) OR EQUAL PER DETAIL, THIS SHEET. ® REMOVE AND SALVAGE EXISTING SIGNAL HEADS, PEDESTRIAN HEAD AND PEDESTRIAN PUSH BUTTON AND INSTALL NEW SIGNAL HEADS, PEDESTRIAN HEAD AND PEDESTRIAN PUSH BUTTON AS SHOWN AND. AS DIRECTED BY THE ENGINEER. z ❑5 REMOVE EXISTING SHAFT MOUNTED ISNS AND INSTALL MAST ARM MOUNTED REFLECTIVE STREET NAME SIGN PER THE SPECIAL PROVISIONS AND AS DIRECTED BY THE ENGINEER. © EXISTING 1.5" CONDUIT. REMOVE EXISTING CONDUCTORS AND INSTALL 2 DLC AS DIRECTED BY THE ENGINEER. F7]INSTALL 3" CONDUIT PARALLEL TO EXISTING CONDUIT AND IN TO EXISTING PULLBOXES AS DIRECTED BY THE ENGINEER. P O L E S C H E D U L E LSTANDARD ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING PED S.N.S. REMARKS C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. PHASE MESSAGE A 17-2-80 E 30 2 E 1 E 200 W E B 6 E MAS, SV- 1-T SP -1 -CS 8 SIERRA AVE B 1-A E B 8 S TV- 1-T SP -1 -CS 6 C 26-4-80 30 40 15 200 W B 8 S MAS, MAS, SV- 1 -T SP -1 -CS 2 ORANGE WAY D 1-A (E B 2 W TV -1-T SP -1 -CS 8 E 17-2-80(E) 30 120(E)15(E)200 W(E) B 1 2 W MAS, SV- 1-T SP -1 -CS 4 SIERRA AVE F 1-A E B 4 N TV -1-T SP -1 -CS 2 G 26-4-80 30 40 15 200 W B 4 N MAS, MAS, SV- 1 -T SP -1 -CS 6 ORANGE WAY H 1-A E B 6 E TV- 1-T SP -1 -CS 4 (E)=EXISTING EQUIPMENT TO REMAIN SCALE: 1"=20' L J� 180' TO -1 CROSSWALK L J 0,0E12 UI SIERRA AVENUE -$ I CONSTRUCTION SET W.� �o QROFESSlpNq! CLYDE ELWYN SWEET, JR. No. 26690 4L Exp, 3 -3 j_q G �j CIVIL q�F OF1F0�`�`� CAL ^-1'--' Detector Most Arm OPTICAL DETECTOR MOUNTING DETAIL Not to Scale LO to CONSTRUCTION NOTES ❑1 REMOVE AND SALVAGE EXISTING TYPE "M" CONTROLLER ASSEMBLY. INSTALL CITY FURNISHED CONTROLLER ASSEMBLY INCLUDING TYPE 'P' CABINET, TYPE 90 CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED TO PROVIDE THE DESIRED OPERATION, MODIFY EXISTING TYPE 'M' FOUNDATION FOR TYPE 'P' CABINET AS DIRECTED BY THE ENGINEER. 0 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING 120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V UN -METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL CIRCUIT BREAKER, 30 A LIGHTING CIRCUIT BREAKER, PEC FOR LIGHTING IN SERVING UTILITY PORTION OF ENCLOSURE, ❑3 INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M511) OR EQUAL PER DETAIL, THIS SHEET. ® REMOVE AND SALVAGE EXISTING SIGNAL HEADS, PEDESTRIAN HEAD AND PEDESTRIAN PUSH BUTTON AND INSTALL NEW SIGNAL HEADS, PEDESTRIAN HEAD AND PEDESTRIAN PUSH BUTTON AS SHOWN AND. AS DIRECTED BY THE ENGINEER. z ❑5 REMOVE EXISTING SHAFT MOUNTED ISNS AND INSTALL MAST ARM MOUNTED REFLECTIVE STREET NAME SIGN PER THE SPECIAL PROVISIONS AND AS DIRECTED BY THE ENGINEER. © EXISTING 1.5" CONDUIT. REMOVE EXISTING CONDUCTORS AND INSTALL 2 DLC AS DIRECTED BY THE ENGINEER. F7]INSTALL 3" CONDUIT PARALLEL TO EXISTING CONDUIT AND IN TO EXISTING PULLBOXES AS DIRECTED BY THE ENGINEER.