Loading...
HomeMy WebLinkAbout2238-2CONDUCTOR TABLE VIDEO CABLE 1 1 2 2 2 2 2 1 1 VIDEO SVC 1 1 2 2 2 2 2 1 1 CIRCUIT OR RUNS LUMINAIRE PED PUSH PHASE 1 PHASE 2 PHASE 3 PHASE 4 N 0 T USED C TYPE HT. AWG. POLE PHASE 7 POLE 0 PHASE QUAD VEHICLE PED. MESSAGE 1 1 1 1 1 26A-4-80 M 45 15' 250W B 6 EAST MAS,MAS,SV-1—T SP-1—CS Tamarind Ave. 1.15' 10.33' U POLE0 2 1—A 10' — — — 1 1 1 1 1 1 TV -1—T SP-1—CS O:f 3.70' 4.85' 19A-4-80 35' 20' 15' 250W B 8 0 MAS, SV -1 —T SP-1—CS Arrow Blvd. —0.63' 5.05' SPECIAL LENGTH MASTARM REQUIRED 1 1 1 1 — — POLE 3 0 2 WEST TV -1—T SP-1—CS — 1 1 1 1 26-4-80 � 40' 15' 250W B 2 WEST MAS,MAS,SV-1—T SP-1—CS Tamarind Ave. 2.57' 5.03' o POLE O4 1—A 10' — — — 1 1 1 1 1 1 1 — 6.30' 2.90' 7 19A—.4-80 35' 1 1 1 B 4 U MAS,SU-1—T SP-1—CS Arrow Blvd. 2.75' 5.17' SPECIAL LENGTH MASTARM REQUIRED 8 1—A 10' — — J POLE 50 1 1 1 1 1 1 1 1 1 1 3.35' 5.24' POLE 6 O 1 1 1 1 1 1 1 1 POLE 70 1 1 1 1 1 1 U POLE 80 1 1 o 0 1 1 U TOTAL 1 1 2 2 3 3 4 4 4 4 4 4 4 4 3 3 2 2 1 1 10 ILUMINAIRE 1 2 1 2 1 2 1 2 1 2 1 1 1 2 1 2 VIDEO VIDEO CABLE 1 1 2 2 2 2 2 1 1 VIDEO SVC 1 1 2 2 2 2 2 1 1 DET. MASTARMS OPTICOM CABLE 1 1 1 2 2 J 2 2 2 1 1 CONDUIT SIZE 3" 3" 3" 4" 4" 4" 4" 3" 3" 3" PHASE DIAGRAM N 0 T U SED MASTARMS LUMINAIRE PED PUSH PHASE 1 PHASE 2 PHASE 3 PHASE 4 N 0 T USED C TYPE HT. PHASE 5 PHASE 6 PHASE 7 PHASE 8 ARROW 2" C, 2 #6,1#8 (SERVICE,GFCI) INTERCONNECT 'TO PALMETTO AVENUEPP #2284001 E 2" C, 2 #10 (LUMINAIRES) SEE SHEET 3 OF 3 (ELECTRIC SERVICE POINT) SCALE: 1`20' WATER EXISTING RIGHT OF WAY SERVICE 5 - — — — — --- — — — -- — — — — — — — — — — — — — T — __________________ -- 4 DRIVEWAY I EXISTING _CURB _AND _ GUTTER G� — — — — — — — — — — - T � —T—T -- T 4"W - 1„G ---- 8” S 8" S — T CD co 12"W 12"W - - — — — — — — — — — EXISTING CURB AND GUTTER EXISTING RIGHT OF WAY EXISTING SIDEWALK TRAFFIC SIGNAL GENERAL NOTES: 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800)422-4133, TWO (2)WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS SHOWN OTHERWISE. ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS. 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 7. WHERE SIGNAL CONDUIT STREET CROSSINGS ARE NOT TO BE INSTALLED USING A BORING METHOD, STREET SHALL BE REPAIRED PER DETAIL THIS SHEET AND THE SPECIAL PROVISIONS, SECTION E. 8. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING IS OPERATIONAL PER SPECIFICATIONS. 9. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. DRAWING OF RECORD - 5/00 NO CHANGES III 32 32 I II Q I III III � � I III III < w l II I III �, I w 0 II III III v l II 0 Uj------I � II1•---- 2 0'2 0' --1 1 11 CD � 1 �II O I II I I I II 11 0 Zz1 OIII 11101 lz SII plll Illy l IIS W xl zll Illz wl� VIIl I III< Ilx w I I I I I M I U II I I II U I I� zll I LO I II z l II Q II ~ 11 I `r' CD I I III I II W II U)II I I I II I I p 1 wll I �� I II w l I cn III II III I I CD 1 III III I I z (12 mm I II I I (% II 1 I 4 III I II x J o� w II I I I I III I 82/ 0o �' I A6 1 9 C qp P11LE SCHEDULE L STANDARD MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT REMARKS C TYPE HT. SIG. LU M. H.P.S.U. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B 1 26A-4-80 35' 45 15' 250W B 6 EAST MAS,MAS,SV-1—T SP-1—CS Tamarind Ave. 1.15' 10.33' 2 1—A 10' — — — B 8 SOUTH TV -1—T SP-1—CS — 3.70' 4.85' 3 19A-4-80 35' 20' 15' 250W B 8 SOUTH MAS, SV -1 —T SP-1—CS Arrow Blvd. —0.63' 5.05' SPECIAL LENGTH MASTARM REQUIRED 4 1—A 10' — — — B 2 WEST TV -1—T SP-1—CS — 1.60' 5.40' 5 26-4-80 30' 40' 15' 250W B 2 WEST MAS,MAS,SV-1—T SP-1—CS Tamarind Ave. 2.57' 5.03' 6 1—A 10' — — — B 4 NORTH TV -1 —T SP-1—CS — 6.30' 2.90' 7 19A—.4-80 35' 20' 15' 250W B 4 NORTH MAS,SU-1—T SP-1—CS Arrow Blvd. 2.75' 5.17' SPECIAL LENGTH MASTARM REQUIRED 8 1—A 10' — — — B 6 EAST TV -1—T SP-1—CS — 3.35' 5.24' BOULEVARD HEADER CUT TACK COAT ALL EDGES � '.0.10' MIN. EXISTING AC SURFACING NEW A.C. 2—SACK SLURRY BACKFILL (INITIAL POUR TO BE FLUSH WITH SURROUNDING SURFACE) RIGID METAL CONDUIT (INSTALLED WITH 18” MIN. COVER) TRENCH REPAIR DETAIL N.T.S. INTERCONNECT TO ALDER AVENUE WATER ® SEE CITY DRAWING NO. 2233, SHEET 2 OF 3 SERVICE EXISTING RIGHT OF WAY — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — P #817838H T — — T_EXISTING CURB AND GUTTER_ =I= — _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ = _ = = = _ _ _ _ _ _ _ _ _ _ _ 811W 811W — — T Ln I i T Q0 III III U'I I `SII II I III 4 II I 411 (12 I I III II III � I I III II IIIA I ; 1 I III 111 � 1 I III II III I II I II I� I I I III I I II w II I III I I I II �1 ' I III I IID, III I I I II CDI I I III II I Ilzl PP # 1825270 E i I III i1 IIQ1 III III I' i I III I II0D QII I � II I I II UI II I Ld I III CI Z I I III I Ilzl � I I U> -- Qi IIIU) XI I< �1 I zlll Illwl wll I SII I III I IQ 01 I OfIII I 111 1 =i UIII i III 1 0 I-- 20' --i 20' —•LII ry ry Il z I III I -D O �_. II I III z z II U II I I III I F- I— wlll III x —I x w I� 132 30 III 111 w D -7 1 '.5A M—,Zkr_ :Lb 1�0 DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TM.- FREE 1-800-422-4133 A PUBLIC SERVICE BY INDERGROLM SERVICE ALERT 3„� — --- 3„� ---- _ --- --G-- ---- ---- 8” S — — 8” S — — 8" S Q0 0 4 (8 mm) Ln O5 EXISTING SIDEWALK I EXISTING CURB AND GUTTER L——————————————————————————————— \�. EXISTING RIGHT OF WAY EXISTING BUILDING ROOF OVERHANG TRAFFIC SIGNAL CONSTRUCTION NOTES: Curb/Berm flow lir or edge of should4 BCR N I MAST—ARM MOUNTING CLAMP FOR MODEL 711 OPTICAL DETECTOR �1 INSTALL TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "P" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION TO BE INSTALLED PER CITY STANDARD DRAWING 134. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. ❑2 FURNISH AND INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS (SEE SPECIAL PROVISIONS). �3 FURNISH AND INSTALL UNI—DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711 OR EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER (SEE SPECIAL PROVISIONS). �4 INSTALL IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND AS DIRECTED BY THE ENGINEER (SEE SPECIAL PROVISIONS). ❑5 FURNISH AND INSTALL 3" PVC CONDUIT WITH PULL ROPE PER SCE REQUIREMENTS. F6] EXISTING LUMINAIRE TO BE REMOVED (BY SOUTHERN CALIFORNIA EDISON). AUTOCAD FILENAME: ARROW_TAMARIND_SG_RECDWG.DWG