Loading...
HomeMy WebLinkAbout2235-40 66 0 0 Ln L a CD v i z 0 F -I U z 0 LL_ F-1 U w Q cn rr F- F --1 U F- C-) W D O n cn c!D 3 0 i m / o CITRUS AVENUE R/W R/W SIGNAL CONSTRUCTION GENERAL NOTES: 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.' PHONE UNDERGROUND SERVICE ALERT AT 800/422-4133, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 5 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN. ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS. PROVIDE ANGLE VISORS ON ALL INDICATIONS, PER ES -3C OF CALTRANS STANDARD PLANS. 6. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY TRAFFIC ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 11. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 13. ALL TRAFFIC CONTROL, WORK ZONES AND LANE CLOSURES SHALL BE COMPLETELY DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR SHALL FOLLOW THE MANUAL OF TRAFFIC CONTROLL DEVICES FOR CONSTRUCTION AND MAINTENANCE WORK ZONES, CALTRANS STANDARD SPECIFICATIONS AND STANDARD PLANS, LATEST EDITION. EXACT LOCATION OF ALL TRAFFIC CONTROL TO BE DETERMINED BY THR CITY ENGINEER AND ADDITIONAL WARNING AND/OR CONSTRUCTION SIGNING MAY BE REQUIRED. 14. REMOVAL OF ALL EQUIPMENT AND TRAFFIC CONTROL SHALL BE COORDINATED WITH THE CITY OF FONTANA TRAFFIC SECTION. STOP SIGNS WILL BE REMOVED ONLY BY CITY FORCES. FIVE (5) WORKING DAYS WRITTEN NOTICE IS REQUIRED TO COORDINATE WORK WITH CITY FORCES. 15. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING AND * TRAFFIC CONTROL TO THEIR ORIGINAL CONDITION, PLAN REQUIREMENTS OR TO THE SATISFACTION OF THE ENGINEER. 1-800-422-4133 IT'S THE LAW I CALL AT LEAST TWO DIAL BEFORE WORKING DAYS PRIOR YOU DIGI TO EXCAVATING G � A� UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 SCALE: 1 " 2 0' I CITRUS AVENUE I I t I I i i i R/W R/W I ' ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ - 0 d' d - O ---- ----- - --- ----- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- " � I W W (n L _ _� ADD 1 SIC TO EX. 1.5"C, 1 -DLC �-___� *ADD 1 SIC TO EX. 1.5"C, 2 -DLC Z— — G— — — — — — — — — ;— — — — — — — - ---- —G- - ----- ----- ----- — — — — --- -G- 'G - - - - - - - - - - - - - - - - - - - - I - - - - ----- 1.5"C' - - - I I , I 1 , 1- I—r + 1.5"C, 1 SIC ------------------ ------ ---- i -r-------------- --77-----T�-------------------------------------------------------------------------- -- -------- -�-T-7-------T ----------------------- ----- — LJ II II II II -Lam_—--__-_ _ _ I 11 II 11 II 11 ------- ---------------- -----------------------------------------------------------------�--- u u u u u �. Q w 0 W w Q —L----------------------------------------------------i----------L-- -------- _ /W Q W Q R/W I_'�, > > 1 � W d0- Q EXISTING EDISON SERVICE POINT AND CONDUIT z I t l I I I a. CL O I I I I n w I U I I I I > I I I I * � I I INSTALL ONE (1) NEW SIC IN EXISTING CONDUIT J BETWEEN PULLBOX AND CONTROLLER CABINET. w I m I I U Q n IL: -------------------------------------------------- --- --------------------------------------- --------------------------------------------------------------------------------------------------------------------------------- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J O– – – – – – – – – – – – – – –ww w – – – – – – – – w – O ---- ----- -- -- ----- ----- ----- - --- ----- ----- ----- ----- ----- ----- ----- ---- ----- ---- --- - Ld N m F— W W W W I V ---- ----- -- -- ----- ----- --- ----- ----- ---- ----- ---- --- - ----- W — ------ — — ------ — — _ Lij z 1.5"C, 1 SIC 1.5"C, 1 SIC 1.5"C, 1 SIC = ------------------71------77 ----- r'j- J G J G I -L� I I 1 1 -------------„-----r'ri----------------- J G J G v I I 1 1/ ri- 1-44-i - -----Ff-------77 ----- I I 1 1 ----------------------------------- V GL --------------- ------ ------------------ ------------- \\ -- ----- �----------- \\ -----�----- -- ------ ----- �I�I r ---- Q ,” t _" t 0 ;o� I II �� _q- ,J L o� I I I I -r-1 LJ I/ l l \\� \\� -r ]I LII 2 SEE SHEET 2 OF 4 FOR 11 II u II 11c II III I' II II II I I II 11 II 11 ( 11 � CONTINUATION OF Q � �i INTERCONNECT SYSTEM w Q w w Q Q w N w Q R/W w w r� w Q w d- Q w z Q R/W z w L Q w N L L N � co ,�j N � �j 0 Q N �j CO � > > v— > CO > CO > p > 0 Ld> O d' 0 D:f w CCO w 0 "t ❑tf w � 0 x w O d' Of w O 'd- w 0 = v— O tet- W tY O0 < < < < < n tZ SIGNAL CONSTRUCTION GENERAL NOTES: 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.' PHONE UNDERGROUND SERVICE ALERT AT 800/422-4133, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 5 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN. ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS. PROVIDE ANGLE VISORS ON ALL INDICATIONS, PER ES -3C OF CALTRANS STANDARD PLANS. 6. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY TRAFFIC ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 11. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 13. ALL TRAFFIC CONTROL, WORK ZONES AND LANE CLOSURES SHALL BE COMPLETELY DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR SHALL FOLLOW THE MANUAL OF TRAFFIC CONTROLL DEVICES FOR CONSTRUCTION AND MAINTENANCE WORK ZONES, CALTRANS STANDARD SPECIFICATIONS AND STANDARD PLANS, LATEST EDITION. EXACT LOCATION OF ALL TRAFFIC CONTROL TO BE DETERMINED BY THR CITY ENGINEER AND ADDITIONAL WARNING AND/OR CONSTRUCTION SIGNING MAY BE REQUIRED. 14. REMOVAL OF ALL EQUIPMENT AND TRAFFIC CONTROL SHALL BE COORDINATED WITH THE CITY OF FONTANA TRAFFIC SECTION. STOP SIGNS WILL BE REMOVED ONLY BY CITY FORCES. FIVE (5) WORKING DAYS WRITTEN NOTICE IS REQUIRED TO COORDINATE WORK WITH CITY FORCES. 15. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING AND * TRAFFIC CONTROL TO THEIR ORIGINAL CONDITION, PLAN REQUIREMENTS OR TO THE SATISFACTION OF THE ENGINEER. 1-800-422-4133 IT'S THE LAW I CALL AT LEAST TWO DIAL BEFORE WORKING DAYS PRIOR YOU DIGI TO EXCAVATING G � A� UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 SCALE: 1 " 2 0' I CITRUS AVENUE I I t I I i i i R/W R/W I ' ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ - 0 d' d - O ---- ----- - --- ----- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- - - - -- " � I W W (n L _ _� ADD 1 SIC TO EX. 1.5"C, 1 -DLC �-___� *ADD 1 SIC TO EX. 1.5"C, 2 -DLC Z— — G— — — — — — — — — ;— — — — — — — - ---- —G- - ----- ----- ----- — — — — --- -G- 'G - - - - - - - - - - - - - - - - - - - - I - - - - ----- 1.5"C' - - - I I , I 1 , 1- I—r + 1.5"C, 1 SIC ------------------ ------ ---- i -r-------------- --77-----T�-------------------------------------------------------------------------- -- -------- -�-T-7-------T ----------------------- ----- — LJ II II II II -Lam_—--__-_ _ _ I 11 II 11 II 11 ------- ---------------- -----------------------------------------------------------------�--- u u u u u �. Q w 0 W w Q —L----------------------------------------------------i----------L-- -------- _ /W Q W Q R/W I_'�, > > 1 � W d0- Q EXISTING EDISON SERVICE POINT AND CONDUIT z I t l I I I a. CL O I I I I n w I U I I I I > I I I I * � I I INSTALL ONE (1) NEW SIC IN EXISTING CONDUIT J BETWEEN PULLBOX AND CONTROLLER CABINET. w I m I I U Q n