Loading...
HomeMy WebLinkAbout2233-1-1CONDUCTOR TABLE ARROW BARRIER PHASE DIAGRAM RUNS CIRCUIT OR 1 2 3 4 5 6 7 8 s o PHASE 6 AWG. POLE POLE OA STANDARD ARMS LUMINAIRE 1-1 1-1 1-1 SIGNAL MOUNTING PED. POLE OB PLACEMENT REMARKS o TYPE HT. 1-1 1-1 H.P.S.V. TYPE PHASE QUAD VEHICLE POLE ( PED. PHASE MESSAGE A B A 26A-4-80 35' Lu 15' 250 W B 6 E MAS, MAS, SV -1-T SP -1 -CS 8 J POLE OD 12' F=16' B 1-A 10' - - 1-1 1-1 1-1 1-1 TV -1 SP -1 -CS 6 - 1' 4.5' C 26-4-80 o POLE OE 1-1 1-1 1-1 1-1 1-1 1-1 1-1 SV -1-T SP -1 -CS 2 Arrow Blvd. 1' 7' F=17' D 1-A 10' - - - B 2 U N POLE OF TV -1-T 1-1 1-1 1-1 1-1 1-1 1-1 1' 6.5' E 26A-4-80 35' 45' 15' 250 W B 2 W MAS, MAS, SV -1-T SP -1 -CS i POLE OG Alder Ave. 10' 1-1 1-1 1-1 1-1 1-1 - - - B z N TV -1-T SP -1 -CS 2 - 10' 5' 0 24A-4-80 35' 35' 15' 250 W B 4 N MAS, MAS, SV -1 -T SP -1 -CS POLE OH 6 Arrow Blvd. 1' 1-1 1-1 1-1 1-1 10' - - - B 6 E TV -1-T SP -1 -CS 4 - 2' 4' TOTAL 1-1 2-2 3-3 4-4 5-5 6-6 6-6 2-2 2-2 2-2 1-1 10 LUMINAIRE 1 2 1 2 1 2 1 2 1 2 1 2 1 1 2 1 2 VIDEO CABLE 1 1 2 2 3 3 3 1 1 1 VIDEO VIDEO SVC 1 1 2 2 3 3 3 1 1 1 DET. OPTICOM CABLE 1 1 2 2 3 3 3 1 1 1 CONDUIT SIZE 3 1 3 1 4" 4" 4" 4" 4 1 3 1 3 1 3" 1 3" ARROW BARRIER PHASE DIAGRAM am - PHASE 1 PHASE 2 PHASE 3 PHASE 4 H E D U L PHASE 5 PHASE 6 PHASE 7 PHASE S 2" C, 2 #10 44' - I 1 12' i I 32 II II II II II II II II II II II II II II II II 00 II � II �' II II II N II v Ij II N II II Q NOTE 7 I I 8 r� v SIDEWALK DRAIN, PROTECT IN PLACE SEE SHEET 2 OF 3 FOR 6 + o CONTINUATION OF cv INTERCONNECT SYSTEM Q w o w" 5 111 OB n> m STA. 23+1040 EXISTING RIGHT OF WAY _ W 20 mtd TEL A rJ -�,- 0 2j T T-VAULT1_ -_ - -- 5 T # 108P T— 12 -Fri - T 14-r�rtLEL _771- 108P i ��E -----E-- ------ 5 E - - - - - - - - - - - - - - - -- - — - — - — - — - — - — - — - - — - - — - — - — - — - — - — - - — - 7 0 Ln EXISTING CURB & GUTTER f -CAP T IN L ET be % , N --- Lu -11 $ _ T - T T 4 --mt T T - ' w U W N- - - - - - - - - - - - - - - - - - , - 3 I ., c:) 4 + -£ 3"G 3 G 3 G N� ---- ---- --- - - - - W - - _s_ - - - -s- un s-- cn EXISTING CURB & GUTTER ' (iJ 12 gwmr 1.2 Z - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 - - - - - - _ _ _ _ _ _ _ _ _ _ _ _ LJ II 11 U 004� �� 1- EXISTING RIGHT OF WAY 3 6 _ G II - II 3 II II II II II II II II II II Ld II � II CD II Cl II < II m II � II CDII z II � II Lx I I II II --ll II II II II G_—ll I I II I II 12' II 44' a p DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-422-4133 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT SIGNAL GENERAL NOTES: 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND. STANDARD PLANS (DATED JULY 1992) 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT 800/422-4133, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT WHERE NOTED OTHERWISE. ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS. 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING IS OPERATIONAL PER SPECIFICATIONS. 6. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. 9. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 10. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION AND COUNTY OF SANBERNARDINO PRIOR TO COMMENCEMENT OF WORK. 11. WHERE TRAFIC SIGNAL STREET CROSSING CONDUITS ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE PER DETAIL THIS SHEET, AND SPECIAL PROVISIONS, SECTION E. -� 44' SII w }32'�-;i 12' I� 11 ><- r t I o V, 0 5"E ' SCALE: 1 "=20' TRIM TREE BRANCHES AS DIRECTED BY ENGINEER EXISTING VAULT N0. V5011218 r� \ - C �ELECTRICAL SERVICE POINT EXISTING RIGHT OF WAY 'T r T - w 07 TRIM TREE BRANCHES AS DIRECTED BY ENGINEER f O �- EXISTING MARBELITE TO BE REMCjVED BY SCE. -� � T T -_T �- T �T BOULEVARD UE - Tin � - CITY OF FONTANA CENTERLINE G 8 '�L--SANARDINO COUNTY G 3.� 3 G 3 G BERN 04 Q °n -S- - - - - - - - - - - - - - - _r r L (12mm)----�--------------- - - - - -- -------------------- _—_�_______== -I--- �� EXISTING CURB EXISTING CURB AND GUTTER 1 ' F— �4y — — — �,, n DRIVFWAY EXISTING RIGHT OF WAY N � P/L HEADER CUT TACK COAT 1, 1, ALL EDGES EXISTING 0.10' MIN. AC SURFACING NEW A.C. 2 -SACK SLURRY BACKFILL (INITIAL POUR TO BE FLUSH WITH SURROUNDING SURFACE) RIGID METAL CONDUIT (INSTALLED WITH 18" MIN. COVER) TRENCH REPAIR DETAIL N.T.S. SIGNAL CONSTRUCTION NOTES Efl INSTALL CITY FURNISHED TYPE 90 CONTROLLER ASSEMBLY, INCLUDING TYPE "P" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION TO BE INSTALLED PER CITY STANDARD 134. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. �2 FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON REQUIRMENTS (SEE SPECIAL PROVISIONS). �3 FURNISH AND INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M 711 OR EQUAL) PER CITY STANDARD NO. 138. F4-] INSTALL AUTOSCOPE IMAGE SENSOR UNIT PER CITY STANDARD NO. 133 AND AS DIRECTED BY THE ENGINEER. E] FURNISH AND INSTALL 3" PVC CONDUIT WITH PULLROPE AND 36" PVC SCHEDULE 80 RISER SWEEP FROM ELECTRICAL SERVICE POINT TO SERVICE ENCLOSURE PER EDISON REQUIRMENTS. © INSTALL 1.5" CONDUIT. #5 PULLBOXES, AND INTERCONNECT CABLE AS SHOWN ON THE PLAN. EXTEND CONDUIT AND INTERCONNECT CABLE INTO CABINET AT THE INTERSECTION OF ARROW AND TAMARIND PER SHEET 1, DRAWING 2238. p7 INSTALL 1.5" CONDUIT. #5 PULLBOXES, AND INTERCONNECT CABLE AS SHOWN ® FURNISH AND INSTALL R73-3 SIGN AND HARDWARE PER CALTRANS DETAIL ES -6T. AUTOCAD FILENAME: Arrald-1999—NWver.dwg P 0 L E S C H E D U L E L STANDARD ARMS LUMINAIRE PED PUSH BTF. SIGNAL MOUNTING PED. S.N.S. PLACEMENT REMARKS o TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. PHASE MESSAGE A B A 26A-4-80 35' 45 15' 250 W B 6 E MAS, MAS, SV -1-T SP -1 -CS 8 Alder Ave. 1.6' 12' F=16' B 1-A 10' - - - B 8 S TV -1 SP -1 -CS 6 - 1' 4.5' C 26-4-80 35' 40' 15' 250 W B 8 S MAS, MAS, SV -1-T SP -1 -CS 2 Arrow Blvd. 1' 7' F=17' D 1-A 10' - - - B 2 W TV -1-T SP -1 -CS 8 - 1' 6.5' E 26A-4-80 35' 45' 15' 250 W B 2 W MAS, MAS, SV -1-T SP -1 -CS 4 Alder Ave. 10' 4' F=17' 'Fl 1-A 10' - - - B 4 N TV -1-T SP -1 -CS 2 - 10' 5' G 24A-4-80 35' 35' 15' 250 W B 4 N MAS, MAS, SV -1 -T SP -1 -CS 6 Arrow Blvd. 1' 4' F=16' H 1-A 10' - - - B 6 E TV -1-T SP -1 -CS 4 - 2' 4' EXISTING VAULT N0. V5011218 r� \ - C �ELECTRICAL SERVICE POINT EXISTING RIGHT OF WAY 'T r T - w 07 TRIM TREE BRANCHES AS DIRECTED BY ENGINEER f O �- EXISTING MARBELITE TO BE REMCjVED BY SCE. -� � T T -_T �- T �T BOULEVARD UE - Tin � - CITY OF FONTANA CENTERLINE G 8 '�L--SANARDINO COUNTY G 3.� 3 G 3 G BERN 04 Q °n -S- - - - - - - - - - - - - - - _r r L (12mm)----�--------------- - - - - -- -------------------- _—_�_______== -I--- �� EXISTING CURB EXISTING CURB AND GUTTER 1 ' F— �4y — — — �,, n DRIVFWAY EXISTING RIGHT OF WAY N � P/L HEADER CUT TACK COAT 1, 1, ALL EDGES EXISTING 0.10' MIN. AC SURFACING NEW A.C. 2 -SACK SLURRY BACKFILL (INITIAL POUR TO BE FLUSH WITH SURROUNDING SURFACE) RIGID METAL CONDUIT (INSTALLED WITH 18" MIN. COVER) TRENCH REPAIR DETAIL N.T.S. SIGNAL CONSTRUCTION NOTES Efl INSTALL CITY FURNISHED TYPE 90 CONTROLLER ASSEMBLY, INCLUDING TYPE "P" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION TO BE INSTALLED PER CITY STANDARD 134. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. �2 FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON REQUIRMENTS (SEE SPECIAL PROVISIONS). �3 FURNISH AND INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M 711 OR EQUAL) PER CITY STANDARD NO. 138. F4-] INSTALL AUTOSCOPE IMAGE SENSOR UNIT PER CITY STANDARD NO. 133 AND AS DIRECTED BY THE ENGINEER. E] FURNISH AND INSTALL 3" PVC CONDUIT WITH PULLROPE AND 36" PVC SCHEDULE 80 RISER SWEEP FROM ELECTRICAL SERVICE POINT TO SERVICE ENCLOSURE PER EDISON REQUIRMENTS. © INSTALL 1.5" CONDUIT. #5 PULLBOXES, AND INTERCONNECT CABLE AS SHOWN ON THE PLAN. EXTEND CONDUIT AND INTERCONNECT CABLE INTO CABINET AT THE INTERSECTION OF ARROW AND TAMARIND PER SHEET 1, DRAWING 2238. p7 INSTALL 1.5" CONDUIT. #5 PULLBOXES, AND INTERCONNECT CABLE AS SHOWN ® FURNISH AND INSTALL R73-3 SIGN AND HARDWARE PER CALTRANS DETAIL ES -6T. AUTOCAD FILENAME: Arrald-1999—NWver.dwg