HomeMy WebLinkAbout1948-1-3SCALE: 1' = 150'
I CROP. DETER-rIOtil
I i3146s 1 t4 SITE
3
Wu
sEWC-le MAIN PF-5?ALWISi?\A
j o AveOuGi 712UNK 5SWS12
a, PLANS DWG- WD. 2038
I
I
3
N SSW �R MAI N P�� t3AS�L I t`l
I AVENUlE PL&.'t�
�
`�
Baseline
244
I FA
lls
-
I
INSTALL
�Irvv -,
� 3
2l 4
2 l 3
2 t Z
21 t
l t d
2 0oj
\
LATERAL WYE (6"X4")
a'
<
Z43 p� 23
II
r
-
21�
I->=
TEL. (818) 448-6183
JOIN TO
2�
Avenue
F_A,
MR. FRANK LOGUIDICE
o
l7�
M
245
s�
...
12EMC)\/E 6" T';LUIG JOIN F_X 1STl NG SeWFR
nd
G
-
FONTANA, CA. 92335
TEL. (714) 350-7640
loo
2l�
SOUTHERN CALIFORNIA EDISON COMPANY
I
a' ►
- •
P.O. BOX 788
x
o
� �T6 �1 fib �7
lfs x s1a L _tis
�l • 1:1d �
J l'! M-
1p
LEGEND:
242
c
Wclj
c
RIALTO. CA. 92376
_
MR. DAVE JONES
U
(714) 820 - 5191
�
24 �
MANHOLE
2 3 !,0
I
232
21-7
ll�
GAS:
S
F_
K
T
�
`�
Baseline
244
•
234-
>>
c
INSTALL
�Irvv -,
� 3
2l 4
2 l 3
2 t Z
21 t
l t d
2 0oj
\
LATERAL WYE (6"X4")
a'
<
Z43 p� 23
G0I,15T.
233
21�
I->=
TEL. (818) 448-6183
JOIN TO
2�
Avenue
F_A,
MR. FRANK LOGUIDICE
o
l7�
I
245
s�
...
12EMC)\/E 6" T';LUIG JOIN F_X 1STl NG SeWFR
nd
G
-
FONTANA, CA. 92335
TEL. (714) 350-7640
2l�
SOUTHERN CALIFORNIA EDISON COMPANY
I
ISI,
- •
P.O. BOX 788
x
o
� �T6 �1 fib �7
lfs x s1a L _tis
�l • 1:1d �
J l'! M-
�
LEGEND:
242
c
Wclj
c
RIALTO. CA. 92376
_
MR. DAVE JONES
U
(714) 820 - 5191
�
24 �
MANHOLE
2 3 !,0
I
232
21-7
ll�
GAS:
S
F_
K
T
l5
15231 VALLEY BLVD.
1.
3
3
T
ACT
MAIN
N
l
31
rn
SOUTHERN CALIFORNIA GAS COMPANY
INDICATES
241 237
TERMINAL CLEANOUT
23l
218
2191 E. BIRCH STREET
INDICATES
SEWER
PLUG
17(q
BREA, CA. 92621
247
�j1
(714) 529 - 2889
?O2w
203
204. 205
206
2a7
3939 E. CORONADO STREET
Zd0 239 238
230
2(9
z
20 t
200
I �1
(°� 8
(c)_/
1�7
248
rn
y
9000 HELLMAN AVENUE
RANCHO CUCAMONGA, CA. 91730
PRIVATE ENG I NEER' S NOTES
TO CONTRACTOR
2
0/3=1
4
��
3
22�
2 20
rn
3
�,�
o
X23
1�s
rn
228
_
179
22l
s�
«
250
--�
227
222
t 80
051 252 253 064
}..�
v
t °l4
K
2(,O
t 9 I
[`)2-
°i2 193
`��
259
59
258 257 2156 255
22�
Z 23
t
18?
t 8�
l S
5
'S
Baseline
%p -- .�l /�rrL! -911 s11 -J ►VI _
•
NOTES:
>>
c
INSTALL
�Irvv -,
WATER:
r
v
�•I
a�
11142 GARVEY AVENUE, P.O. BOX 6010
INSTALL
LATERAL WYE (6"X4")
a'
<
EL MONTE. CA. 91734
G0I,15T.
COWC . �lc�s t✓1�.1T Utz- c -T 8141- 17
Miller
I->=
TEL. (818) 448-6183
JOIN TO
EXISTING SEWER (tZEMOVE 15' GrWv-l2 PLUG
Avenue
F_A,
MR. FRANK LOGUIDICE
o
SEWER TERMINAL- CLEANOUT PER STD. DTL. 128 E pLUGY
I
SEWER:
s�
...
12EMC)\/E 6" T';LUIG JOIN F_X 1STl NG SeWFR
nd
G
-
FONTANA, CA. 92335
TEL. (714) 350-7640
POWER:
SOUTHERN CALIFORNIA EDISON COMPANY
I
ISI,
- •
P.O. BOX 788
x
o
� �T6 �1 fib �7
lfs x s1a L _tis
�l • 1:1d �
J l'! M-
�
LEGEND:
14
c
Wclj
c
RIALTO. CA. 92376
_
MR. DAVE JONES
U
(714) 820 - 5191
�
SEWER
MANHOLE
Route
I
GAS:
SOUTHERN CALIFORNIA GAS COMPANY
a
HOUSE
LATERAL
15231 VALLEY BLVD.
FONTANA, CA. 92335
MR. LOU WESTFALL
INDICATES
SEWER
MAIN
(714) 889 - 9711
SOUTHERN CALIFORNIA GAS COMPANY
INDICATES
SEWER
TERMINAL CLEANOUT
TRANSMISSION' DIVISION
2191 E. BIRCH STREET
INDICATES
SEWER
PLUG
BREA, CA. 92621
(714) 529 - 2889
W - - - - l 24 125 12(P 10 7 120 I Zg 130 l 3 l 1 I
W W W- W W W \ti
2�3_..
s ti SEWra12 MAIN PER ALME121a
_ST IALMERIA V�.►
-
3 y �ti AVENUE T121,INK SEWEI2 I __T
I I
�� ` pLA�1S C�WG. NO. 2 D 38
24 27 TCCA T NO 1334,8
9� 97 9.8 99 lad tol 10Z ,a �' 120 �x15T. 14 -
3 %) Sg SS S7 86 85 84- S3 3 SEW612 MAIN 1p�12 � � M•1%S 4 � l
23 ZS 8 2 57 U vw&. NO, I1(a2q - O I 1
R C 0 123 4
2 rn l05 =
� 22 9 s , 1 s � s �� �S � �uliutz� W�,LNUT �
I 111 17 / 8\ 1 15 / 16
35 3(l 37 138 I'�`� I L I `FV� 3 144 I Ori Iola 1 47 ,+a +4
+4\ 112
-1 NDEX MAP-
SCALE:
1"= 150'
Baseline
%p -- .�l /�rrL! -911 s11 -J ►VI _
•
NOTES:
>>
c
INSTALL
�Irvv -,
WATER:
SAN GABRIEL VALLEY WATER COMPANY
040"
v
�•I
a�
11142 GARVEY AVENUE, P.O. BOX 6010
INSTALL
LATERAL WYE (6"X4")
a'
<
EL MONTE. CA. 91734
G0I,15T.
COWC . �lc�s t✓1�.1T Utz- c -T 8141- 17
Miller
I->=
TEL. (818) 448-6183
JOIN TO
EXISTING SEWER (tZEMOVE 15' GrWv-l2 PLUG
Avenue
F_A,
MR. FRANK LOGUIDICE
o
SEWER TERMINAL- CLEANOUT PER STD. DTL. 128 E pLUGY
�pA
SEWER:
CITY OF FONTANA
12EMC)\/E 6" T';LUIG JOIN F_X 1STl NG SeWFR
to
G
8353 SIERRA AVENUE
FONTANA, CA. 92335
TEL. (714) 350-7640
POWER:
SOUTHERN CALIFORNIA EDISON COMPANY
I
-
- •
P.O. BOX 788
x
o
� �T6 �1 fib �7
lfs x s1a L _tis
�l • 1:1d �
J l'! M-
�
LEGEND:
c
Wclj
c
RIALTO. CA. 92376
_
MR. DAVE JONES
I 111 17 / 8\ 1 15 / 16
35 3(l 37 138 I'�`� I L I `FV� 3 144 I Ori Iola 1 47 ,+a +4
+4\ 112
-1 NDEX MAP-
SCALE:
1"= 150'
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES. CONDUITS
OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO
EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR
IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY
LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL
LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES. CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THAT THIS
REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS: AND THAT THE CONTRACTOR SHALL DEFEND. INDEMNIFY AND
HOLD THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY. REAL, OR ALLEGED.
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
PRIVATE ENGINEER'S NOTE:
THE PRIVATE ENGINEER SIGNING THESE PLANS IS RESPONSIBLE FOR ASSURING
THE ACCURACY AND ACCEPTABILITY OF THE WORK HEREON. IN THE EVENT OF
DISCREPANCIES ARISING DURING CONSTRUCTION THE PRIVATE ENGINEER SHALL
BE RESPONSIBLE FOR DETERMINING AN ACCEPTABLE SOLUTION AND REVISING
THE PLANS FOR APPROVAL BY THE CITY.
U
f..-1 13
CONSTRUCTION NOTES AND QUANTITY ESTIMATE
61 T5
Baseline
8" SEWER MAIN (ax-rR A STiz1=U GT H
UTILITY
NOTES:
>>
c
INSTALL
>
WATER:
SAN GABRIEL VALLEY WATER COMPANY
>
v
2 S
a�
11142 GARVEY AVENUE, P.O. BOX 6010
INSTALL
LATERAL WYE (6"X4")
a'
<
EL MONTE. CA. 91734
G0I,15T.
COWC . �lc�s t✓1�.1T Utz- c -T 8141- 17
Miller
I->=
TEL. (818) 448-6183
JOIN TO
EXISTING SEWER (tZEMOVE 15' GrWv-l2 PLUG
Avenue
F_A,
MR. FRANK LOGUIDICE
o
SEWER TERMINAL- CLEANOUT PER STD. DTL. 128 E pLUGY
�pA
SEWER:
CITY OF FONTANA
12EMC)\/E 6" T';LUIG JOIN F_X 1STl NG SeWFR
to
G
8353 SIERRA AVENUE
FONTANA, CA. 92335
TEL. (714) 350-7640
POWER:
SOUTHERN CALIFORNIA EDISON COMPANY
I
I
P.O. BOX 788
x
o
v
-�
300 N. PEPPER STREET
LEGEND:
c
Wclj
c
RIALTO. CA. 92376
_
MR. DAVE JONES
U
(714) 820 - 5191
INDICATES
SEWER
MANHOLE
Route
I
GAS:
SOUTHERN CALIFORNIA GAS COMPANY
INDICATES
HOUSE
LATERAL
15231 VALLEY BLVD.
FONTANA, CA. 92335
MR. LOU WESTFALL
INDICATES
SEWER
MAIN
(714) 889 - 9711
SOUTHERN CALIFORNIA GAS COMPANY
INDICATES
SEWER
TERMINAL CLEANOUT
TRANSMISSION' DIVISION
2191 E. BIRCH STREET
INDICATES
SEWER
PLUG
BREA, CA. 92621
(714) 529 - 2889
TELEPHONE:
PACIFIC TELEPHONE
3939 E. CORONADO STREET
ANAHEIM. CA. 92807
(714) 999 - 5639
GENERAL TELEPHONE
9000 HELLMAN AVENUE
RANCHO CUCAMONGA, CA. 91730
PRIVATE ENG I NEER' S NOTES
TO CONTRACTOR
9141' 945 - 3562
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES. CONDUITS
OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO
EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR
IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY
LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL
LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES. CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THAT THIS
REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS: AND THAT THE CONTRACTOR SHALL DEFEND. INDEMNIFY AND
HOLD THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY. REAL, OR ALLEGED.
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
PRIVATE ENGINEER'S NOTE:
THE PRIVATE ENGINEER SIGNING THESE PLANS IS RESPONSIBLE FOR ASSURING
THE ACCURACY AND ACCEPTABILITY OF THE WORK HEREON. IN THE EVENT OF
DISCREPANCIES ARISING DURING CONSTRUCTION THE PRIVATE ENGINEER SHALL
BE RESPONSIBLE FOR DETERMINING AN ACCEPTABLE SOLUTION AND REVISING
THE PLANS FOR APPROVAL BY THE CITY.
U
f..-1 13
CONSTRUCTION NOTES AND QUANTITY ESTIMATE
61 T5
VICINITY MAP
NOT TO SCALE
1
Baseline
8" SEWER MAIN (ax-rR A STiz1=U GT H
-7, 6'5 2
Avg
>>
c
INSTALL
>
c
>
c
>
v
2 S
a�
�
INSTALL
LATERAL WYE (6"X4")
a'
<
}
a
G0I,15T.
COWC . �lc�s t✓1�.1T Utz- c -T 8141- 17
Miller
I->=
6
JOIN TO
EXISTING SEWER (tZEMOVE 15' GrWv-l2 PLUG
Avenue
F_A,
7
o
SEWER TERMINAL- CLEANOUT PER STD. DTL. 128 E pLUGY
�pA
8
12EMC)\/E 6" T';LUIG JOIN F_X 1STl NG SeWFR
to
G
J
Foothill
I
I
Boulevard
I -
x
o
v
-�
D
o
c
Wclj
c
o
_
U
Arrow
Route
I
VICINITY MAP
NOT TO SCALE
1
INSTALL
8" SEWER MAIN (ax-rR A STiz1=U GT H
-7, 6'5 2
L
2
INSTALL
4" HOUSE LATERAL (EXTPA STv_F_N GT H )
e),7 70
LT�_
3
CONSTRUCT SEWER MANHOLE [4' DIA.) PER STD. DTL. 112 & 114
2 S
A-
4
INSTALL
LATERAL WYE (6"X4")
4 02
t5 A
5
G0I,15T.
COWC . �lc�s t✓1�.1T Utz- c -T 8141- 17
84
I->=
6
JOIN TO
EXISTING SEWER (tZEMOVE 15' GrWv-l2 PLUG
F_A,
7
INSTALL
SEWER TERMINAL- CLEANOUT PER STD. DTL. 128 E pLUGY
�pA
8
12EMC)\/E 6" T';LUIG JOIN F_X 1STl NG SeWFR
to
zLRECORD DRAWING
A L L SEWERS SHALL BE EXTRA
STRENGTH PIPE -
NOTE
X48 HOUR�ELEPHODE P[ByOw 422A4R 3S(IUGSNG]
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD PLANS OF
THE CITY OF FONTANA AND THE STANDARD SPECIFICATIONS FOR PUBLIC
WORKS CONSTRUCTION, LATEST EDITION.
2. NOTHING IN THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM OBTAINING
PERMITS AS REQUIRED BY THE CITY OF FONTANA.
3. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN
APPROXIMATE WAY ONLY. THE CONTRACTOR. SHALL DETERMINE THE EXACT
LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. HE
AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT
BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY
AND ALL UNDERGROUND UTILITIES.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, REPLACEMENT
OR RELOCATION OF ALL REGULATORY, WARNING AND GUIDE SIGNS.
5. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH
MARKS NOTED ON THE PLANS, OR FOUND DURING CONSTRUCTION. REMOVAL AND
REPLACEMENT SHALL BE DONE BY A REGISTERED CIVIL ENGINEER. WITH RCE
NUMBER BELOW 14814, OR A LICENSED LAND SURVEYOR ONLY.
5. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER 48 HOURS PRIOR TO ANY
GRADING. BRUSHING OR CLEARING AND EACH PHASE OF CONSTRUCTION AT
(619) 564-2246. AND 48 HOURS PRIOR TO REQUIRING INSPECTION.
7. DURING ROUGH GRADING OPERATIONS AND PRIOR TO CONSTRUCTION OF
STRUCTURES. TEMPORARY DRAINAGE CONTROL SHALL BE PROVIDED TO PREVENT
PONDING WATER AND DAMAGE TO ADJACENT PROPERTY.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN EFFECTIVE MEANS
OF DUST CONTROL WHICH SHALL INCLUDE PROVISIONS FOR ADEQUAT WATERING
DURING THE GRADING PROCESS AND PROVISIONS FOR CONTINUANCE OF DUST
CONTROL AFTER THE GRADING UNTIL SUCH TIME THAT THE GRADED SURFACE
PRESENTS EFFICIENT PROTECTIVE COVER AGAINST WIND OR WATER EROSION
THAT SPECIAL DUST CONTROL MEASURES ARE NO LONGER NECESSARY.
9. LOCATIONS OF FIELD DENSITY TEST SHALL BE DETERMINED BY THE SOIL
ENGINEER OR APPROVED TESTING AGENCY AND SHALL BE SUFFICIENT IN BOTH
HORIZONTAL AND VERTICAL PLACEMENT TO PROVIDE REPRESENTATIVE TESTING
OF ALL FILL PLACED. TESTING IN AREAS OF A CRITICAL NATURE OR
SPECIAL EMPHASIS SHALL BE IN ADDITION TO THE NORMAL REPRESENTATIVE
SAMPLINGS.
10. ALL UNDERGROUND FACILITIES. WITH LATERIALS. SHALL BE IN PLACE AND
INSPECTED PRIOR TO PAVING. INCLUDING. BUT NOT LIMITED TO THE
FOLLOWING: SEWER, WATER, ELECTRIC, GAS AND DRAINAGE.
11. ALL TRAVELED WAYS MUST BE CLEANED DAILY OF ALL DIRT. MUD AND DEBRIS
DEPOSITED ON THEM AS A RESULT OF THE GRADING OPERATION. CLEANING IS
TO BE DONE TO THE SATISFACTION OF THE CITY ENGINEER.
12. ALL CONSTRUCTION AREAS SHALL BE PROPERLY POSTED AND LIGHTED IN CON-
FORMANCE WITH THE STATE MANUAL OF WARNING SIGNS. LIGHTS AND
DEVICES FOR USE IN THE PERFORMANCE OF WORK UPON HIGHWAYS. IN ORDER
TO ELIMINATE ANY HAZARDS.
13. ALL EXISTING IMPROVEMENTS INCLUDING CURB AND GUTTERS, SIDEWALKS.
ASPHALT CONCRETE OR P.C.C. PAVING. WHICH ARE BEING JOINED OR
MATCHED IN CONNECTION WITH THIS PROJECT, SHALL BE JOINED OR MATCHED
IN A MANNER SATISFACTORY TO THE CITY ENGINEER. INCLUDING NECESSARY
SAW CUTTING. REMOVAL, REPLACEMENT AND CAPPING.
14. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA PUBLIC
WORKS DEPARTMENT PRIOR TO THE START OF ANY WORK WITHIN THE CITY
LIMITS.
15. ALL STATIONING REFERS TO CENTERLINE OF STREET.
16. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES.
17. ALL PIPELINE OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
OR POLES, WATER METERS, VALVES, HYDRANTS. IRRIGATION STRUCTURES,
ETC. SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE
IMPROVED AND INTERFERING WITH CONSTRUCTION. SHALL BE RELOCATED BY
OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBLITY TO NOTIFY ALL
AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS.
18. "AS -BUILT" PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR.
19. ALL EXISTING MANHOLE FRAMES AND COVERS TO BE CONSTRUCTED BY THE
SEWER CONTRACTOR 6" BELOW FINISHED SURFACE GRADE AND DURING PAVING.
THE PAVING CONTRACTOR SHALL RAISE SAME TO FINISHED GRADE.
20. INSPECTION TO BE CALLED FOR THROUGH CITY OF FONTANA. C7143350-7610
24 HOURS PRIOR TO STARTING WORK.
21. ALL PROPOSED CONNECTIONS TO EXISTING ELEVATIONS OF EXISTING UTILI-
TIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO START OF ANY
WORK. ANY DEVIATIONS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY.
22. ALL UTILITIES SHALL BE CONSTRUCTED.TESTED. APPROVED. AND BACKFILLED
TO THE SATISFACTION OF AND CERTIFIED BY THE SOILS ENGINEER'PRIOR TO
ANY PAVING.
23. TERMINATE -ALL 4" HOUSE SEWER LATERALS 3' INSIDE THE LOT WITH A
PLUG. SHOULD A PUBLIC UTILITIES EASEMENT LIE CONTINGUOUS TO THE
STREET R -O -W, THE LATERAL SHALL EXTEND -ACROSS THE EASEMENT AND
TERMINATE 3' INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT
LINE.
24. ALL SEWER LATERALS*SHALL BE INSTALLED ON A 2% MINIMUM GRADE UNLESS
OTHERWISE APPROVED BY THE CITY ENGINEER.
25. SEWER CONTRACTOR SHALL CHISEL "X" IN THE CURB AT THE LOCATION OF
THE LATERALS.
" 25. NO LATERALS SHALL BE PLACED UNDER DRIVEWAYS.
27. ENGINEER SHALL CHECK OUT ORIGINAL SEWER IMPROVEMENT PLANS AND
TRANSFER "AS -BUILT" INFORMATION PRIOR TO CITY ACCEPTANCE OF THE
SEWER SYSTEM.
28. PRIOR TO CONSTRUCTION OF WATER, SEWER AND/OR STORM DRAIN
LINES THE CONTRACTOR SHALL EXPOSE THE EXISTING._WATER, SEWER
AND/OR STORM DRAIN LINES WHERE -CONNECTIONS WILL OCCUR AND
VERIFY THEIR ELEVATION AND LOCATION. APPROVAL BY THE CITY
OF FONTANA OF A PROPOSED CONNECTION TO A CITY FACILITY DOES
NOT IMPLY APPROVAL OF THE CORRECTNESS OF THE ELEVATION
AND/OR LOCATION AS SHOWN ON PLANS.
29. COWTF-ACTOR. SHkLL ADJUST ALL MAt�HOLF_ A041) GLEANOUT 2tM5
TO FIMI15R Gg&DE ELEVATION.
NOTE
SEE SHEET NO, 17 FOR .TRENCHING
AND BEDDING DETAILS
INEER R.C.E.-25t3t;?-