HomeMy WebLinkAbout2677-1GENERAL NOTES:
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA
STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK").
2 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING
DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE
REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
3 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
4 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
5 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR
TO PAVING OF STREETS.
6 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILITIES, AND TO*EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO.
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-226-2700
TWO WORKING DAYS BEFORE EXCAVATION.
7 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED
TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
8 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
9 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
10 WHEN CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT
BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK",
THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER
FOR RESOLUTION.
11 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
12 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH
TO MATCH EXISTING CONCRETE.
13 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
14 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS
PURSUANT TO THE REQUIREMENTS
15 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK
FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION
OF INDUSTRIAL SAFETY.
16 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
17 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS
TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY
DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
18 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES.
19 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE
TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION
OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
20 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
21 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL
STAKING DURING CONSTRUCTION.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE
TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED
IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED
AGENCIES IMMEDIATELY.
24 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT
TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
25 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED
CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE
DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR
SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
26 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL
TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE
AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
27 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT
PRIOR APPROVAL OF THE INSPECTOR.
28 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT TYPE VITRIFIED
CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS
OF THE ASTM DESIGNATION C700 FOR V.C.P..
29 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12"
BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE
STREET RIGHT-OF-WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS
MEASURED FROM THE UTILITY EASEMENT.
30 THE SEWER CONTRACTOR SHALL STAMP AN "S° IN THE FACE OF THE CURB AT THE
LOCATION OF THE SEWER LATERAL.
31 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE
A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE
DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
32 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
33 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND
VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS
TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS
SHOWN ON THE PLANS.
34 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
35 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE
WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
36 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS
AND PROCEDURES DESCRIBED IN THE "W.A.T.C.H. MANUAL", LATEST EDITION UNLESS
OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING,
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION
OF THE CITY TRAFFIC ENGINEER.
39 NO OPEN TRENCH SHLL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL
OF THE CITY ENGINEER.
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
ATTN: CARLOS NAVARRO
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6632
SO. CALIFORNIA GAS COMPANY
ATTN: ALAN KESELOFF
16231 VALLEY BLVD.
FONTANA, CA 92335
(909) 335-7781
EMERGENCIES: (800) 427-2200
S0. CALIFORNIA EDISON COMPANY
ATTN: JAIME AMESZCUA
(909) 357-6581
7951 REDWOOD AVENUE
FONTANA, CA 92335
(909) 820-5598 - UNDERGROUND
(909) 820-5137 - TRANSMISSIONS
(213) 637-1233 - PIPELINES
(909) 357-6589 - DISTRIBUTION
(800) 422-4133
CRAWFORD CANYON MUTUAL WATER CO
ATTN: BILL VANDRKIEFT, JR.
(619) 868-6040
UNDERGROUND SERVICE ALERT
(800) 227-2600
SUMMIT
PACIFIC BELL CO.,
ATTN: VIRGINIA BECKER
3939 E. CORONADO STREET
ANAHEIM, CA 92807
(714) 666-5467
COMCAST (CABLE TV)
ATTN: JACK HAYES
1205 DUPONT AVENUE
ONTARIO, CA 91761
(909) 390-4777 X 3055
GENERAL TELEPHONE COMPANY
ATTN: STEVE HOCK
1400 E. PHILLIPS BLVD.
ONTARIO, CA 91766
(800) 422-4133
FONTANA WATER COMPANY
ATTN: AL KROHN
8440 NUEVO AVENUE
FONTANA, CA 92335
(909) 822-2201 X 323
FAX: (909) 823-5046
4 a ::::::„.57•11111111,4;; ��II9 \IIIA►Q • �•m ems ow - m qii: Mil 4 l‘ ilb =ma pl.
wift
so
a .1 le
"' if
an s g 46
AMfine�
a
P.A. 14A
P.A. 14B
AVER
FUTURE COMMERCIAL
FUTURE COMMERCIAL
AVENUE
FUTURE ROUTE
30 FREEWAY
LOCATION MAP
0INDICATES 1 N
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES.
SHOWN ON THESE PLANS ARE.OBTAINED BY A SEARCH OF AVAILABLE RECORDS;
TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT
THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON-
SIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT
SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS-
IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;
AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER
AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
Underground Service Alert
CALL
TOLL FREE
1-800
227-2600
TWO WORKING DAYS BEFORE YOU DIG
INDEX IEAEr NUMBERS
3/4: 1 SLOPE OR GREATER
OR ADEQUATE SHORING
GRANULAR BEDDING FROM
SELECTED TRENCH SIDE
MATERIAL (1" MAX. SIZE)
PIPE ZONE
90% COMPACTED
NATIVE BACKFILL
3" MAX. SIZE
" MI
SEWER OR WATER MAIN
MAX.
J
J
w
0
J
w•
0.6'D IM -IE I
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIRE
10' OR GREATER IN DEPTH USE
1/2 CRUSHED STONE BEDDING.
•
NOTES:
1. TRENCH WIDTH SHALL BE CONTROLLED
TO TOP OF PIPE ZONE.
2. TRENCH DEPTHS OF GREATER THAN 5'
SHALL HAVE ADEQUATE SHORING.
3. CLASS II AGG.BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
NOTE: COMPACTION SHALL BE 90% IN -ALL
ZONES UNLESS OTHERWISE SPECIFIED.
TRENCH STABILITY SHALL CONFORM
TO CAL -OSHA REQUIREMENTS,
TRENCH DETAIL
NOT TO SCALE
PLANS PREPARED FOR
KAUFMAN & BROAD
ATTN: MR. MIKE PEARSON
801 CORPORATE CENTER DRIVE
SUITE 201
POMONA, CA. 91768-2641
PHONE: (909) 802-1100
FAX: (909) 802-1111
BENCH MARK:
CONSTRUCTION NOTES:
® INSTALL 8" EXTRA STRENGTH V.C.P. SEWER
O2 CONSTRUCT PRECAST CONCRETE MANHOLE
PER CITY OF FONTANA STD.DWG. NO. 112 (I.D.=48")
03 INSTALL 4" V.C.P. SEWER LATERAL PER CITY OF
FONTANA STD. DWG. NO. 125.7 sT.n • DWG. //4,
CASE //•
RAILROAD SPIKE AT INTERSECTION
OF CITRUS AVE. AND LOS CEDROS
AVE., IN POWER POLE N0. 9011E
ON THE EAST SIDE OF CITRUS AVE.
ELEVATION: 1167.59
/
0
0
W
FUTURE
INTERCHANGE
w
J
H
r
HIGHLAND
1k
i
4
DUNCAN
CYN. RD.
SUMMIT
AVENUE
BASELINE AVENUE
w
z
w
.m
F--
0
AVENUE
w
z.
a
w
N
w
z
w
1-
0
0
J
VICINITY MAP
NOT TO SCALE
QUANTITIES
TR. 15682-1 TR. 15682-2 TR. 15682-3 TR. 15682 TOTAL
595 � 897 967 437 2,896 L.F.
RECQR.DF.wI
THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN
PART, ON THE BASIS OF INFORMATION CQMPILED AND
FURNISHED BY OTHEAS. THE ENGINEER WILLNOT BE
RESPONSIBLE FOR ANY ERRORS OR OMJSStONS WHICH
HAVE BEEN (NCORPORNED .INTO THE DXUMENTS AS
A RESULT THEREOF:
BASIS OF BEARINGS:
THE BEARING OF N89°30'06" ALONG
TOWNSHIPH1LNORTHF SECTION WEST
ONNRECORDROFNSURVEYDFILEDAINSBOOK
58 PAGE WAS
THE BASIS BEARINGS
FOR THIS MAP
4 4 4 3 15 EA.
•
. 359 699 658 264 1,980 L.F.
CITY OF FONTANA,
CALIFORNIA
Ijor 44/a3 1=11 -07/03
REVISIONS
APPROVAL DATE APPROVAL DATE
PREPARED IN THE OFFICE OF
MADOLE AND ASSOCIATES, INC
OF THE INLAND EMPIRE
10601 CHURCH STREET STE. 107
RANCHO CUCAMONGA, CA 91730
PHONE (909) 948-1311
. MADOLE R.C.E.14814 DATE
DRAWN BY:
M.F.G.
DESIGNED:
C.F.B.
CHECKED:
SIERRA LAKES
TRACT NO. 15682
SEWER PLANS
TITLE SHEET
SCALE:
AS SHOWN
DATE:
JOB NO.
826-1163 APP OV
TM H(11► qn
CITY ENGINEER R.C.E. 25126
DWG. NO.
2677
SHEET NO.
1 OF5
EP) SEWER TITLE SHEET, TR. NO. 15682 - 21[0,231]PF: 15682 755 23 -Apr -99 1101 AM / 826-1154-1
DWG. DATE: -5-75'-q9
M
co