HomeMy WebLinkAbout4935-1GENE M4 SE�AFER NQUS-4 1 ALL WORK SHALL BE IN ACCOROANCE WITH THESE PLANS, THE CITY OF FONTA M, STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCT -ION ("GREEN BOOKI. ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOC NTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN TW -100 I BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO TK CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHOTHE ENGINE US ARE SUBJECT TO E AP W ROVAL OF THE CITY ER. 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FRG" THE CITY OF FONTANA COMMUNITY DEVE- LOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION, COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 3-50-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7 THE CONTRACT -OR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY TE UT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10 THE LOCATIONS OF UTIUTIES SHOWN HAVE BEEN DETERMINED FROM AV ABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20 140 TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPEG4FIED DENSITY IS OBTAINED. 22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITOWS-S, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH To MATCH EXISTING CONCRETE. 24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWN STREAM MAW40LE, SEE CITY Of FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25 SANITARY SEWER LINES- MALL -HALL BE CONSTRUCTED OF BELLA Wi SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P.. 26 NO OPEN TRENCH -SHALL BE ALIOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGIAIER. 27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 200 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED Aff A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT ­ AY, THE LATERAL SHALL TERMINATE S FEET INSIDE THE LOT AS MEASURED FROM THE U TY EASEMI1NT. 31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH T - PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY TETE ENG#­4EER AtM_ ALL AFFECTED AGENCIES IMMEDIATELY. 33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRR TO PAVING OF STREETS. 35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT 36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING 37 UPON COMPLETION Of CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AM OTA --,R TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE At4i'D COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWWER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON -THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS. CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS. CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES, UTILITY BOXES AND LIDS, ETC. CONTRACTOR SHALL PROVIDE ALL THE NECESSARY PIPE FITTINGS TO COMPLETE THE WORK. THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THESE PLANS MUST BE REQUESTED IN WRITING AND MUST BE APPROVED BY THE ENGINEER OF RECORD. I iqp�1111 III I A.C. ASPHALTIC CONCRETE (R) RIDGE UNE B.C. BEGIN CURVE R/W RIIGHT OF WAY B.V.C. BEG. VERTICAL CURVE TAN. TANGENT B.W. BACK SIDEWALK T.C. TOP OF CURB C.B. CATCH BASIN W WIDTH C.L. CENTERLINE V VERTICAL DEPTH E.C. END CURVE (590.69) INDICATES EXISTING ELEVATION E.P. EDGE PAVEMENT E.G. EDGE GRADE 590.69 INDICATES PROPOSED ELEVATION E.V.C. END VERTICAL CURVE [590.69] INDICATES FUTURE ELEVATION F.L. FLOW LINE _Y INDICATES SLOPE 2:1 MAX. F.S. FINISH SURFACE G.B. GRADE BREAK AC PAVEMENT H.P. HIGH POINT REMOVAL INV. INVERT GRIND O.C. ON CURVE P.C.C. PORTLAND CEMENT CONCRETE /// EDGE OF PAVEMENT .SEWER: CABLE: CITY OF FONTANA TIME WARNER CABLE 8353 SIERRA AVENUE 1"5 DUPONT AVENUE FONTANA, CA 92335 ONTARIO, CA. 91761 PHONE: 909.350.6632 PHONE: 909.390.4738 GAS: TELEPHONE. SOUTHERN CALIFORNIA GAS COMPANY AT&T 16231 VALLEY BLVD. 11464 TELEGRAPH ROAD FONTANA, CA 92335 SANTA FE SPRINGS, CA 90670 PHONE: 909.428.8411 PHONE: 714.666.5415 SOUTHERN CALIFORNIA EDISON COMPANY 7951 REDWOOD AVE. FONTANA, C. 92336 PHONE: 909.357.6221 WATER: WEST VALLEY WATER DIST RIICT 855 W. BASELINE ROAD RIALTO, CA 92377 PHONE: 909-875.1361 1�1 0 . . ...... . COYOTE CANYOJ ROAD *A Ile SCALE: 1'= 150 MADOLE AND ASSOCIATES, INC. CONSULTING CIVIL ENGINEERS & LAND PLAWERS 93a-2 PITTSBURGH AVE.,- 2-30 RANCHO CLJCAMONGA, CA 91730 PHONE: 909.481.6322 FAX: 909.481.6320 CONTACT: MARK BERTONE/T00fl MILLER X, VIGINITY MAP - NOT TO SCALE TOP OF STRUCTURAL rPAVEMENT SUBGRADE 3" MAX. SIZE NATIVE r SOIL COMPACTED 95% NOTES: 6" MIN. 6" MIN. 1. TRENCH WIDTH SHALL BE CONTROLLED 10" MAX. 10" MAX. TO TOP OF PIPE ZONE. 04 2. TRENCH DEPTHS OF GREATER THAN 5 SHALL HAVE ADEQUATE SHORING. 1:1 SLOPE OR FLATTER 3. CLASS 11 AGG. BASE ALL TRENCHES OR ADEQUATE SHORING LESS THAN 100' IN LENGTH. 6" MAX. SIZE 1" MAX. SIZE 4. COMPACTION SHALL BE 90% IN ALL COMPACTED NATIVE SOIL SELECTED NATIVE 90% BEDDING COMPACTED ZONES UNLESS OTHERWISE SPECIFIED. TO 90% TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS. 5. THE SEWER PLUMBER SHALL VERIFY THE ULTIMATE BACKFLOW PREVENTION VALVE 81) C4 V.C.P. BEDDING MATERIAL SHALL MEET OR EXCEED SECTION 306-1.2.1, A z STD. SPECS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION. LOCALLY EXCAVATED NATIVE MATERIALS MAY BE BLENDED TO THE REQUIRED SAND EQUIVALENCY OF 30 OR GREATER NTS (D INSTALL 8" EXTRA STRENGTH V.C.P. SEWER CONSTRUCT 48" PRECAST CONCRETE ~OLE PER CITY OF FONTANA STD. DWG. NO'S. 2000, 2001 & 2003 .e� CONSTRUCT 60- PRECAST CONCRETE MANHOLE PER CITY OF FONTANA STD. DWG. NOS. 2000, 2001 & 2003 INSTALL TEMP. 8" END PLUG. REMOVE PLUG A110 JOIN TO EXISTING 8" SEWER. REMOVE AND REPLACE EXISW AC PVMT. PER CITY STD. 1008 NOTE PRIOR TO START OF CO CONTRACTOR18HALL VERIFY EN ft LOCATO AND ELEVATION AT POINTS OF CONNECTION AND SHALL N011FY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 3INEER R.C.E. 51152 DATE 4935 J:\1 26-2500 \sewer- \SewerOf f site Sewero 1 OS.dwq, 5/18/2012 2:01:53 PM, d,'ov;er