HomeMy WebLinkAbout3665-11I I LS TYPICAL RC BOX SECTION NOT TO SCALE T2/2 T2 -00 TOP OF WALL T� BASE OF WALL LONGITUDINAL JOINT 20 Bar diameters 2 1" 1/3 TRANSVERSE JOINT TOLL FREE -q"=NF1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 9 1 . 2. 3. bars 4. d 6-1 rV 7. 8. 91 10. 11. 12. 13. 14. 15. 16, 17. 18. STRUCTURAL NOTES DIMENSIONS FROM FACE OF CONCRETE TO STEEL ARE TO CENTER OF BAR, UNLESS OTHERWISE SHOWN. CONCRETE DIMENSIONS SHALL BE MEASURED HORIZONTALLY OR VERTICALLY ON THE PROFILE, AND PARALLEL TO OR AT RIGHT ANGLES (OR RADIALLY) TO CENTER LINE OF CONDUIT ON THE PLAN EXCEPT AS OTHERWISE SHOWN. ALL BAR BENDS AND HOOKS SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE'S "BUILDING CODE REQUIREMENT FOR REINFORCED CONCRETE", LATEST EDITION, SECTIONS 7.1 AND 7.2. TRANSVERSE CONSTRUCTION JOINTS SHALL NOT BE PLACED WITHIN 30 INCHES OF MANHOLE OR JUNCTION STRUCTURE OPENINGS. TRANSVERSE CONSTRUCTION JOINTS IN WALLS AND SLABS SHALL BE IN THE SAME PLANE. NO STAGGERING OF JOINTS WILL BE PERMITTED. TRANSVERSE CONSTRUCTION JOINTS SHALL BE NORMAL OR RADIAL TO THE CENTER LINE OF CONSTRUCTION. THE TRANSVERSE REINFORCING BARS SHALL TERMINATE ONE AND ONE—HALF INCHES FROM THE CONCRETE SURFACES UNLESS OTHERWISE SHOWN ON THE STRUCTURAL DETAILS. EXPOSED EDGES OF CONCRETE MEMBERS SHALL BE ROUNDED OR BEVELED. NO SPLICES IN TRANSVERSE BARS REINFORCEMENT WILL BE PERMITTED OTHER THAN SHOWN ON THE DRAWING WITHOUT APPROVAL OF THE ENGINEER. NO MORE THAN TWO SPLICES WILL BE PERMITTED IN ANY LONGITUDINAL BAR BETWEEN TRANSVERSE JOINTS. SPLICES SHALL BE STAGGERED. LONGITUDINAL BARS SHALL BE LAPPED 48 BAR DIAMETERS AT SPLICES. TRANSVERSE BARS SHALL BE LAPPED 48 BAR DIAMETERS AT SPLICES. LONGITUDINAL BARS SHALL BE CONTINUOUS AND EXTEND THROUGH ALL CONSTRUCTION JOINTS. UNLESS OTHERWISE SHOWN ON THE DRAWINGS, TRANSVERSE CONSTRUCTION JOINTS (IN BOTH SLABS AND WALLS), SHALL BE PLACED AT THE END OF EACH POUR, BUT THE SPACING THEREOF SHALL NOT EXCEED 50 FEET NOR BE LESS THAN 10 FEET. UNLESS OTHERWISE SHOWN ON THE DETAILS, IN CURVED SECTIONS TRANSVERSE BARS SHALL BE PLACED RADIALLY. STRAIGHT TRANSVERSE BARS IN TOP AND BOTTOM SLABS SHALL BE SPACED AS SHOWN ON THE TYPICAL SECTIONS: SPACING SHALL BE AT THE CENTER LINE OF THE BARREL ON THE OUTSIDE OF THE CURVE FOR DOUBLE BARREL BOXES. * STRAIGHT BARS AND L—BARS IN WALLS SHALL BE SPACED AS SHOWN ON THE TYPICAL SECTIONS, WITH THE SPACING MEASURED BETWEEN THE VERTICAL LEGS OF BARS. AT THE BEGINNING AND ENDING OF ALL POURS, A CURTAIN OF REINFORCEMENT COMPOSED OF B, C, C2, D, CW, F, G, AND H BARS SHALL BE PLACED THREE INCHES FROM THE TRANSVERSE CONSTRUCTION JOINT. D BARS AND CW BARS MAY BE SPLICED 48 BAR DIAMETERS AT THE LOWER LONGITUDINAL CONSTRUCTION JOINT, AT CONTRACTOR'S OPTION. IN ALL SECTIONS LAP C AND C2 BARS. THE VERTICAL LENGTH OF C AND C2 BARS HAS BEEN CALCULATED//FOR A FOUR—INCH STARTER WALL, IF THE HEIGHT/OF THE STARTER WALL IS `VARIED, THE VERTICAL LENGTH OF THE C AND C2 BARS SHALL BE VARIED CORRESPONDINGLY SO AS TO MAINTAIN A 48 DIAMETER LAP BETWEEN THE TWO BARS. THE LAPS SHALL BE BASED ON THE SMALLER BARS. CONCRETE QUANTITIES ARE BASED ON A SIX—BY—SIX INCH FILLET AND THE STEEL QUANTITIES DO NOT INCLUDE ANY OPTIONAL SPLICES. IF WALL THICKNESS IS SIX INCHES, PLACE REINFORCEMENT AT THE CENTER LINE OF THE WALL. THE DESIGN OF BOX SECTIONS IDENTIFIED BY A NUMERICAL VALUE ONLY IS BASED ON A WIDTH OF TRENCH EQUAL TO THE OUTSIDE WIDTH OF THE CONDUIT PLUS 3 FEET. WHEN THE COVER IS EQUAL TO 10 FEET OR LESS THE TRENCH WIDTH IS UNRESTRICTED. WHEN THE COVER IS GREATER THAN 10 FEET AND THE TRENCH WIDTH IS GREATER THAN THE OUTSIDE WIDTH OF THE CONDUIT PLUS 3 FEET FOR A DISTANCE IN EXCESS OF 10 FEET AN ALTERNATE SECTION SHALL BE USED AS INDICATED BELOW: A. WHEN THE DEPTH OF COVER IS LESS THAN 18 FEET, SECTIONS WITH THE SUFFIX "B" SHALL BE USED. B. WHEN THE DEPTH OF COVER IS GREATER THAN 18 FEET AND: 1. THE TRENCH WIDTH IS LESS THAN THE OUTSIDE WIDTH OF THE CONDUIT PLUS 6 FEET, SECTIONS WITH THE SUFFIX "A" SHALL BE USED. 2. THE TRENCH WIDTH IS GREATER THAN THE OUTSIDE WIDTH OF CONDUIT PLUS 6 FEET, SECTIONS WITH THE SUFFIX "B" SHALL BE USED. BOX SECTION REVISION DESCRIP11ON # 4 BARS Design Cover 10' Width W 8' Height H 8' Top Slab Thickness T1 10" Side Wall Thickness T2 8" Bottom Slab Thickness T 3 11.75" Concrete Cover( 3"linin. Y 3" B Bars Bar No. & Spacing #4 @ 19" Length 17'-9" B 1 Bars Bar No. & Spacing #7 @ 19" Length 17'-9" C Bars Bar No. & Spacing #4 @ 13" Hor. Length 4'-0.5" Vert. Length 8'—"7" C 1 Bars Bar No. & Spacing #4 @ 13" Hor. Length 2'-5" Vert. Length 2'-1" C2 Bars Bar No. & Spacing #4 @ 13" Hor. Length 4'-5.5" Vert. Length 3'-9" BOX SECTION 1 # 4 BARS Design Cover 10' Width W 8' Height H 8' Top Slab Thickness T1 10" Side Wall Thickness T2 8" Bottom Slab Thickness T 3 11.75" Concrete Cover( 3"linin. Y 3" B Bars Bar No. & Spacing #4 @ 19" Length 17'-9" B 1 Bars Bar No. & Spacing #7 @ 19" Length 17'-9" C Bars Bar No. & Spacing #4 @ 13" Hor. Length 4'-0.5" Vert. Length 8'—"7" C 1 Bars Bar No. & Spacing #4 @ 13" Hor. Length 2'-5" Vert. Length 2'-1" C2 Bars Bar No. & Spacing #4 @ 13" Hor. Length 4'-5.5" Vert. Length 3'-9" C3 Bars Bar No. & Spacing #4 @ 13" Hor. Length 2'-5" Vert. Length 3'-1" D Bars Bar No. & Spacing #4 @ 18" Length 9'-10.5" F Bars Bar No. & Spacing #4 @ 19" Length 17'-9" F 1 Bars Bar No. & Spacinq #7 @ 19" Length 17' — 9" G Bars Bar No. & Spacinq #5 @ 14" Length 12'— 8.5" G 1 Bars Bar No. & Spacing #7 @ 14" Length 6'— 5.5" H Bars Bar No. & Spacing #5 @ 14" Length 12'-8.5" H 1 B"rs Bar No. & Spacing #7 @ 14 Length 6'-3.5 )) NUMBER OF LONGITUDINAL REINFORCEMENT includes distribution Top Slab reinforcement } 26 Ext. Walls 30 1 n t. Walls 30 1 nv. Slab 26 TOTAL 112 QUANTITIES Concrete Cu. Yds./Lin. Ft. 1.84 Steel Lbs./Lin. Ft. 209.7 R C BOX LOCATION SCHEDULE Box Sect. Station Line From To 1 222+23.24 1 223+95.78 A SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. STRUCTURAL DESIGN CRITERIA L.A.C.F.C.D. STRUCTURAL DESIGN MANUAL DATED APRIL 1982 LIVE LOAD HS 20-44 unless otherwise noted DEAD LOAD Earth load per Marston's formula: w= 140 pcf Ku=Ku'=0.165 Bd=Outside width of box plus 3 feet Side earth 60 psf per foot of depth Internal water pressure: 62.4 psf per foot of depth Weight of concrete: 150 pcf ALLOWABLE STRESSES fc'=4000 psi at 28 days fc =1800 psi fs =24,000 psi n =8 Shear and bond stresses per A.C.I. 318-63 AS -BUILT Prepared Under The Supervision Of � QROFESS/0 .O � j EB k �lIle AA IT No. 37 s730708 Santo EAno, First 92705 TEL: (714)568-7300 FAX: (714)836-5906 �� OF CALF CITY OF FONTANA, CALIFORNIA SIERRA AVE AND BASELINE AVE IMPROVEMENTS DRAWN BY: STORM DRAIN IMPROVEMENT PLAN SCAM: I'M BASELINE AVENUE DESIGNED BY. DOUBLE C BOX DATE: B. A. S TRUCTURAL SCHED , NOTES AND DETAILS 07/31 /06 CHECKED BY: APP96VED BY: /J DRAWING NO.: 11 Date M. R.I _C1t,FY ENGINE �•�'�I 3665712 DATE: v v s D 0 IMs V3 N 0 L0 N r LO 0 0 N 0 T W J 0 W U Ln IMV 0 0 IM U O 2 IL (D -q- CD w W Cn w V) ¢ i 0 w Z J W M cD 0 a