GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE
6" MAX SIZE N
WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
AE
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
BOOK'. ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
LATEST EDITION UNLESS OTHERWISE NOTED.
Ld
z
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
�
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN INE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
REPORT SAID CONFLICT THE CITY ENGINEER FOR RESOLUTION.
AND ALL AFFECTED AGENCIES IMMEDIATELY.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE
°-
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
CITY ENGINEER.
STEEL HAVE BEEN .PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED ANDAPPROVED
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT
PRIOR TO PAVING OF STREETS.
SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
PAVEMENT PRIOR TO PLACEMENT.
FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF
NUE
BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON
ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL
COMPLETION OF PAVING.
(909) 350-7610.
32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL
METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA
DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS
OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO
THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
THE CITY ENGINEER.
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
34. THE MINIMUM D -LOAD FOR ALL RCP IS 1350.
TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION
35. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE
OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM
PIPES MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE
THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
REINFORCING WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND.
THE CONCRETE DESIGN STRENGTH IN THESE REACHES SHALL BE FC=5,000 PSI
FOR VELOCITIES EXCEEDING 20 FEET PER SECOND AND FC=6,000 PSI FOR
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5)
VELOCITIES EXCEEDING 30 FEET PER SECOND.
FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE
GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS
36. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT
OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED
TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
BY SOILDS TESTS TAKEN AFTER COMPLETETION OF ROUGH GRADING.
THE POTENTIAL FOR GROUND MOVEMENT EXISTS.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC
37. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL
RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT
FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A
PURPOSE.
GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA
FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
CITY OF FONTANA UTILITY NOTIFICATION LIST
THE ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER
PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL
CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO
CITY OF FONTANA S.B.C. INC.
WORKING DAYS BEFORE EXCAVATION.
8353 SIERRA AVENUE 3939 E CORONADO STREET
FONTANA, CA 92335 ANAHEIM, CA 92807
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
(909) 350-6632 (714) 666-5500
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
1981 W. LUGONIA AVENUE (800) 422-4133
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
REDLANDS, CA 92374
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE
(909 ) 335-7547 PACIFIC BELL CO.
PRIOR TO WORK AROUND THEIR FACILITIES.
EMERGENCIES: (800) 427-2200 3939 E. CORONADO STREET
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT ORANAHEIM,
CA 92807
SO. CALIF. EDISON COMPANY (714) 666-5467
WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
300 N. PEPPER AVENUE
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY
RIALTO, CA 92376 VERIZON (TELEPHONE)
FOR VALVE OPERATION AND WATER REQUIREMENTS.
909 820-5598 - UNDERGROUND 1400 E. PHILIPS BLVD.
909 875-5100 -TRANSMISSION ONTARIO, CA 91766
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT
213 637-1233 - PIPELINES (800) 422-4133
WHERE OTHERWISE NOTED.
909 357-6505 - DISTRIBUTION
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE
800 422-4133 FONTANA WATER COMPANY
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO
ATTN: MICHAEL J. McGRAW
ADELPHIA (CABLE TV) 8440 NUEVO AVENUE
THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
1500 S. AUTO CENTER DRIVE FONTANA CA 92235
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
ONTARIO, CA 91761 (909) 822-2201
DURING CONSTRUCTION.
(714) 666-5500 FAX: (909) 823-5046
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE
LEGM.
CITY ENGINEER.
INDICATES PROPOSED A.C. PAVEMENT
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
INDICATES REMOVE EXISTING A.C. PAVEMENT
SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
INDICATES OVERLAY EXISTING A.C.PAVEMENT
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY
- INDICATES CENTERLINE
THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
-- INDICATES RIGHT-OF-WAY UNE
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
- - - - INDICATES EXISTING IMPROVEMENTS
MONUMENT.
INDICATES EXISTING CONTOUR LINE
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL- RESIDENTS
0-0 STREET LIGHTS
AND BUSINESSES AT ALL TIMES, A MINIMUM 12 FOOT JANE SHALL BE
DIRECTION OF FLOW
x x )(;K X X) 1 NPc,}Te5 r✓ x 15T1h/6, fz EV4Tia N
MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
,
6- 3 I N P l c_4 Tc5 &919b& B f E4
AND EMERGENCY VEHICLES.
PRIVATE EMNEERS NOTICE TO CONTRACTOR:
19. THE CONTRACTORS SHALL PROVIDE AND MAINTAIN AN EFFECTIVE
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES
MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR,
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD,
SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE
SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY
OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE
ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR
PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER
WRITTEN APPROVAL
LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS.
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
OF THE CITY INSPECTOR.
CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE
OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING
r
NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER
OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
��c�
AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY
AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
OBTAINED. /
o��SsroNq�
Q4 C NAME j�R y
WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SW �' '°
OF THE DESIGN PROFESSIONAL
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF 1T-{
wE
0SITE,
THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABL-,�.
N • 6
UNAUTHORIZED ChiANGS AND USES
SWALES ENTERING OR LEAVING IMPROVEMENTS.
7 "
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE,
- s GP���C
Tq� o� '� -�r :
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE
COLOR AND FINISH TO MATCH EXISTING CONCRETE.
.
PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
. , r.
REV.
REVISION DESCRIPTION
DATE
ENGR.
CITY
DATE
U (} "� v U � � � f%-EGoC2-b T�P-A•wl�t, 2�3�6 D IRED
3.13•aa ISHOULD MPROVEMEMSSNOTCCOMMENCE ON OFREQUWITHIN
ABANt7bN B/.1 S/,V /NLE - - - gc= � C lojl •I�g TWO YEARS OF THE DATE OF APPROVAL
^"w"^^^^^ � ^"""�^^^ Si�2I1G U,QESHOWN HEREON AND CARRIED FORTH IN A
DIAL ^^ TW❑ WORKING 03 REMOVE BRICK ANI)MaRTAR P�u� °����°9 � I U 12 DIUGENTMANNER,THE GTYENGINEER MAY
REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH
CONDITIONS AND STANDARDS IN EFFECT
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
CITY OF FONTANA
JUNIPER AVENUE
STORM DRAIN PLANS
STATE ROUTE - 210 FWY
- (OLD HIGHLAND AVENUE)
ITT
SO HIGHLAND
AVENUE
WALNUT
AVENUE
e► lr%ry s e A n
SIFTAMN ow a= 0,11A
DEI N110N
MN
Y
SECTION ANA
imouniflol I= -
DOUBLE COURSE
4` X 8" BRICK
AND MORTAR PLUG
SECTION BNB
BRICK AND MORTAR PLUG
4, TYPICAL FOR ALL DIAMETERS
N.T.S.
J6 BAR
12" O.C.
,;JUNCTION STRUCTURE PLUG DETAIL
scn� i.=s.
LASELINE AVENUE
EXISTING GROUND -
VARIES 1 3' 2' 3'
EXISTING 1.5'
GROUND
TiE \\-9" THICK CRUSHED
N o AGGREGATE BASE
FILTER BLANKET
SECTION C -C
SCALE: 17-10'
NOTE
EXCAVATION SHALL BE BY OPEN TRENCH UTILIZING SHORING IN ORDER TO ALLOW
FOR A MINIMUM OF ONE OPEN TRAFFIC LANE ADJACENT TO THE EXCAVATION.
BASIS OF BEARINGS.
BEARINGS ARE BASED ON THE CENTERLINE OF JUNIPER AVENUE
BEING NORTH 00'01'57" WEST AS SHOWN ON TRACT 16572, RECORDED IN
MAP BOOK 304, PAGES 38-44, RECORDS OF SAN BERNARDINO COUNTY.
PREPARED FOR:
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA
92335
(909) 350-7644
BENCHMARK
CITY OF FONTANA BENCHMARK NO. 615
SPIKE IN POWER POLE AT THE
CORNER OF CITRUS AVENUE AND
LOS CEDROS AVENUE
ELEVATION: 1467.59
RECORD IDOC UM EN7
These Record DocuM-encs have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
end/or completeness of .this. information and shall
pAOFESS', not be responsible for Ony errors or omissions
S. h A hic ay be Incorporated -herein as a result
Nd -4397 2 Z
E"p• 6130107
t cM l00,
�FCALWOA
BRICK AND
MORTAR PLUG
RCP
DETAIL "A�
SCALE: 1"=10'
D
- PROJECT LocanoN
STATE ROUTE - 210 FWY
KIM) MAP
N.T.S.
CONSTRUCTION NOTES ESTIMATE OF QUANTITIES
1 INSTALL 72" RCP (D -LOAD PER PROFILE)
2 INSTALL 66" RCP (D -LOAD PER PROFILE)
3 INSTALL 60" RCP (D -LOAD PER PROFILE)
4 INSTALL 54" RCP (D -LOAD PER PROFILE)
5 INSTALL 48" RCP (D -LOAD PER PROFILE)
6 INSTALL 42" RCP (D -LOAD PER PROFILE)
7 INSTALL 36" RCP (D -LOAD PER PROFILE)
8 INSTALL 307 RCP (D -LOAD PER PROFILE)
9 INSTALL 24' RCP (D -LOAD PER PROFILE)
10 SAWCUT, REMOVE. & REPLACE EXISTING AC PAVEMENT PER CITY DWG NO. 131
11 CONSTRUCT MANHOLE PER A.P.W.A. STD PLAN 320-1
12 CONSTRUCT MANHOLE PER A.P.W.A. STD PLAN 322-1
13 CONSTRUCT JUNCTION STRUCTURE PER A.P.WA. STD PLAN 332-1
14 CONSTRUCT JUNCTION STRUCTURE PER A.P.W.A. STD PLAN 331-2
15 CONSTRUCT TRANSITION STRUCTURE PER A.P.W.A. STD PLAN 340-1
16 INSTALL CMP RISER PER CALTRANS STD PLAN D93C, TYPE B
17 CONSTRUCT BRICK AND MORTAR PLUG PER DETAIL SHOWN HEREON
18 REMOVE BRICK AND MORTAR PLUG
19 CONSTRUCT CONCRETE COLLAR PER A.P.W.A. STD PLAN 380-2
20 INSTALL CMP RISER PER CALTRANS STD PLAN D93C, TYPE B
(MODIFIED FOR 60- RISER)
21 CONSTRUCT JUNCTION STRUCTURE PLUG PER DETAIL HEREON
�- CONSTRUCT 4' X 3' RECTANGULAR CONCRETE CHANNEL PER DETAIL ON SHEET 2
23 CONSTRUCT 3' X 2' RECTANGULAR CONCRETE CHANNEL PER DETAIL ON SHEET 2
24 CONSTRUCT ENERGY DISSIPATER PER A.P.W.A. STD. PLAN 384-1
25 CONSTRUCT 1/4 TON RIP RAP (2.7' THICK WITH CRUSHED AGGREGATE BASE FILTER BLANKET)
Z6 CONSTRUCT PIPE HEADWALL PER CALTRANS STD. 089
27 CONSTRUCT 75 LB. RIP RAP (1.5' THICK WITH CRUSHED AGGREGATE BASE FILTER BLANKET)
28 CONSTRUCT CHAIN LINK FENCE AND GATES PER APWA STD PLAN 600-1
29 REMOVE EXISTING AC PAVEMENT
30 CONSTRUCT AC PAVEMENT OVER 12" OF 957 COMPACTED NATIVE SOIL
SEE GENERAL NOTES 36 & 37)
31 j?tr_ NOV7eZ17A
e j/viV TOP OF STRUCTURAL
Pl- U 4PAVEMENT SUBGRADE
0RAF 2EOA ..
32 C0NSj2uC T ✓1JNC P0)V Si,pUCIU�F PL vC
PEI?
067AIL 116rR670y
PEI
PROVIDE ADEQUATE SHORING
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL (1- MAX SIZE)
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE 10'
OR GREATER IN DEPTH USE 1/2
CRUSHED STONE BEDDING
907 COMPACTED
NATIVE BACKFILL
S.
S. Hq'y
6" MAX SIZE N
tZ
N
AE
S. HIG
4LAND AENLIE
8 MAX.
Ld
z
SOF CAL\F�
�
w
w
LO
W1 AVE
°-
ao
BASELINE AVI
NUE
o inn
KIM) MAP
N.T.S.
CONSTRUCTION NOTES ESTIMATE OF QUANTITIES
1 INSTALL 72" RCP (D -LOAD PER PROFILE)
2 INSTALL 66" RCP (D -LOAD PER PROFILE)
3 INSTALL 60" RCP (D -LOAD PER PROFILE)
4 INSTALL 54" RCP (D -LOAD PER PROFILE)
5 INSTALL 48" RCP (D -LOAD PER PROFILE)
6 INSTALL 42" RCP (D -LOAD PER PROFILE)
7 INSTALL 36" RCP (D -LOAD PER PROFILE)
8 INSTALL 307 RCP (D -LOAD PER PROFILE)
9 INSTALL 24' RCP (D -LOAD PER PROFILE)
10 SAWCUT, REMOVE. & REPLACE EXISTING AC PAVEMENT PER CITY DWG NO. 131
11 CONSTRUCT MANHOLE PER A.P.W.A. STD PLAN 320-1
12 CONSTRUCT MANHOLE PER A.P.W.A. STD PLAN 322-1
13 CONSTRUCT JUNCTION STRUCTURE PER A.P.WA. STD PLAN 332-1
14 CONSTRUCT JUNCTION STRUCTURE PER A.P.W.A. STD PLAN 331-2
15 CONSTRUCT TRANSITION STRUCTURE PER A.P.W.A. STD PLAN 340-1
16 INSTALL CMP RISER PER CALTRANS STD PLAN D93C, TYPE B
17 CONSTRUCT BRICK AND MORTAR PLUG PER DETAIL SHOWN HEREON
18 REMOVE BRICK AND MORTAR PLUG
19 CONSTRUCT CONCRETE COLLAR PER A.P.W.A. STD PLAN 380-2
20 INSTALL CMP RISER PER CALTRANS STD PLAN D93C, TYPE B
(MODIFIED FOR 60- RISER)
21 CONSTRUCT JUNCTION STRUCTURE PLUG PER DETAIL HEREON
�- CONSTRUCT 4' X 3' RECTANGULAR CONCRETE CHANNEL PER DETAIL ON SHEET 2
23 CONSTRUCT 3' X 2' RECTANGULAR CONCRETE CHANNEL PER DETAIL ON SHEET 2
24 CONSTRUCT ENERGY DISSIPATER PER A.P.W.A. STD. PLAN 384-1
25 CONSTRUCT 1/4 TON RIP RAP (2.7' THICK WITH CRUSHED AGGREGATE BASE FILTER BLANKET)
Z6 CONSTRUCT PIPE HEADWALL PER CALTRANS STD. 089
27 CONSTRUCT 75 LB. RIP RAP (1.5' THICK WITH CRUSHED AGGREGATE BASE FILTER BLANKET)
28 CONSTRUCT CHAIN LINK FENCE AND GATES PER APWA STD PLAN 600-1
29 REMOVE EXISTING AC PAVEMENT
30 CONSTRUCT AC PAVEMENT OVER 12" OF 957 COMPACTED NATIVE SOIL
SEE GENERAL NOTES 36 & 37)
31 j?tr_ NOV7eZ17A
e j/viV TOP OF STRUCTURAL
Pl- U 4PAVEMENT SUBGRADE
0RAF 2EOA ..
32 C0NSj2uC T ✓1JNC P0)V Si,pUCIU�F PL vC
PEI?
067AIL 116rR670y
PEI
PROVIDE ADEQUATE SHORING
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL (1- MAX SIZE)
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE 10'
OR GREATER IN DEPTH USE 1/2
CRUSHED STONE BEDDING
907 COMPACTED
NATIVE BACKFILL
S.
S. Hq'y
6" MAX SIZE N
tZ
N
AE
6" MIN.
* Exp. 6/30/05
8 MAX.
CHECKED BY.
SOF CAL\F�
ml
LO
°-
571 LF.
666 L.F.
1235 LF.
677 LF.
697 L.F.
385 L.F.
572 L.F.
344 LF.
175 L.F.
22,020 S.F.
7 EA
6 EA
2 EA
1 EA
2 EA
3 EA
7 EA
1 EA
1 EA
1 EA
1 EA
150 LF
128 LF
2 EA
69 TON
2 EA
8 TON
700 LF
47,628 SF
1,328 TON
3" MAX. SIZE
NATIVE SOIL
COMPACTED 957
z
STORM DRAINo w
it l
PIPE m m
NOTES:
1. TRENCH WIDTH SHALL BE CONTROLLED
TO TOP OF PIPE ZONE NOTE:
2. TRENCH DEPTHS OF GREATER THAN 5' COMPACTION SHALL BE 907 IN ALL ZONES
SHALL HAVE ADEQUATE SHORING UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY
SHALL CONFORM TO CAL -OSHA REQUIREMENTS
1VEMENT REPLACEMENT SEE 3. CLASS II AGGREGATE BASE ALL TRENCHES
. SECTIONS ON SHEETS 3 & 5. LESS THAN 100 FEET IN LENGTH
TRENCH BEDDING DETAIL
NTS
Prepared By:
ALLARD ENGINEERING
Civil Engineering - Land Surveying - Land Planning
8253 Sierra Avenue
Fontana, California 92335
(9 9) 356-1815 Fax (909) 356-1795
Iz-15-04
David S. Hammer, A.C.E. 43976 Date
(expires 6/30/2005)
ESS /
QON
S.
S. Hq'y
DRAWN BY.
tZ
,;; No. 43976 m
AE
DESIGNER BY:
* Exp. 6/30/05
C / V O_ �r��P
CHECKED BY.
SOF CAL\F�
ml
CITY OF FONTANA, CALIFORNIA
STORM DRAIN IMPROVEMNET PLANS
JUNIPER AVENUE FROM SCALE:
AS NOTED
� BASELINE AVENUE TO DATE:
SOUTH H(GHIAND AVENUE December, 2004
BY: DRAWING NO.: �
DATE: Z . ex 71re
CIN ENGINEER R.C.E. 5i 152 364 11
Filename: M:\dwg\14907\final design\sd\JUNIPER SD 01.DWG