HomeMy WebLinkAbout4940-1QeMERAu. N07BS
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL
REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE
C17Y ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE
START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT
LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL
OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE
DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET
IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR
OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION
OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN
FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR
GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF
WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT *1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR
TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER
MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE
OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHAD. BE SET BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE
PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY
ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE
WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND
BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED
AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF
DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT
OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT
TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN
APPROVAL
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF
THE CITY INSPECTOR.
21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF
THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE,
THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE SWAL.ES
ENTERING OR LEAVING IMPROVEMENTS.
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR
AND FINISH TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR
SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE
THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA
STANDARD DETAIL FOR TERMINAL CLEANOUT.
S
rl
I YOU DIG / TUU DIU
TOLL FREE 1-800-227-2600
o A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
a
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR
BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND
SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR
V.C.P.
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT
PRIOR APPROVAL OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED
AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH
A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS
EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3
FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE
CURB AT THE LOCATION OF THE SEWER LATERAL.
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED
PRIOR TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PAVEMENT PRIOR TO PLACEMENT.
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE
RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION
OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL
SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO
THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY
ENGINEER.
Cff OF FWAJK LqM NOTMATM WT
CITY OF FONTANA
AT&T
8353 SIERRA AVE
22311 BROOKHURST ST SUITE 203
FONTANA, CA 92335
HUNTINGTON BEACH, CA 92646
(909) 350-6632
(714) 963-7964
SO. CALIF. GAS COMPANY
SPRINT
1981 W. LUGONIA AVE
2592 DUPONT DR
REDLANDS, CA 92374
IRVINE, CA 92612
(909) 335-7967
(800) 659-9698
EMERGENCIES: (800) 427-2200
CENTERLINE
TIME WARNER CABLE
SO. CALIF. EDISON COMPANY
1500 AUTO CENTER DR
300 N. PEPPER AVE
ONTARIO, CA 91761
RIALTO, CA 92376
(909) 975-3439
909 820-5598 - UNDERGROUND
SUNESYS, LLC
909 875-5100 - TRANSMISSION
1325 PICO ST #106
213
637-1233 - PIPELINES
CORONA, CA 92881
909 357-6505 - DISTRIBUTION
(951) 278-0400
UNDERGROUND SERVICE ALERT
(800) 422-4133
FONTANA WATER COMPANY
15966 ARROW BOULEVARD
FONTANA, CA 92335
(909) 822-2201
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR,
SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE
OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT ANY LMLI7Y LINES SHOWN AND ANY OTHER
LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE
OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER
AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY
AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE
OF THE DESIGN PROFESSIONAL
MAU7HOFM CHANUB AI1D USES
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE
PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
REVISION DESCRIPTION
DATE I ENGR. I DATE I CITY
wt
--• • «•IF«
- . �. . -
• ti • ti • ti •
• •• •
•• . • ti . . 'l.ti--
CITY OF FONTANA
TRACT NO. 18676-1 & 18676
SEWER IMPROVEMENT PLANS
........................
ffim MAP
SCALE: 1"=120'
�llyl ZZ -1-1
SOILS SOUTHWEST, INC.
MOLOY GUPTA, RCE 31708
897 VIA LATA, SUITE N
COLTON, CA 92324
PHONE NO. (909) 370-0474
DEVE.00M
YH LIME, LLC
10370 TRADEMARK STREET
RANCHO CUCAMONGA, CA 91730
(909) 291-7600
BASIS OF •
BASIS OF BEARINGS: TAKEN FROM THE CENTERLINE OF LIME AVENUE AS SHOWN
ON TRACT NO. 16271-1, M.B. 297/15-18. BEING N 00-01'12" W
OWN& BENC HMAW (SINCE DESTROYED)
PREPARED FOR: CITY OF FONTANA BENCHMARK NO. 361 RAILROAD
SPIKE IN NORTH FACE OF POWER POLE
PJRJ LIME INVESTMENTS LLC NO. 1536697E AT THE S.W. CORNER OF SULTANA
AVENUE AND BASELINE AVENUE. ELEVATION: 1365.01
10370 TRADEMARK STREET
RANCHO CUCAMONGA, SITE BENCHNIAW
CALIFORNIA 91730SAN BERNARDINO COUNTY BENCHMARK NO. 7-15
(909) 291-7600 "1970" BRASS CAP IN CONCRETE ABUTMENT, LOCATEED
FAX (909) 291-7630 34' NORTH OF CENTERLINE OF FOOTHILL BLVD.
AND 131' WEST OF CENTERLINE OF LIME AVENUE.
ADJUSTED ELEVATKW 0163
r/%M!,
MILLER I AVE
w
GARFIELD DR Q
ADAMS
LN
..............
z
J
FOOTHILL BLVD
AAMMP
N.T.S.
ROJECT LOCATION
ONSTRUCTION NOTES WANUTES
E31 CONSTRUCT 8" EXTRA STRENGTH VCP SEWER MAIN 1,593 L.F.
2 CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 2001 6 EA.
CONSTRUCT 4" EXTRA STRENGTH VCP SEWER LATERAL & CLEANOUT PER 19450 L.F.
CITY STD DWG NO. 2005 (SEE GENERAL NOTE NO. 30)
E64 CONSTRUCT BACKWATER CHECK VALVE 17 EA.
5 CONSTRUCT 8" DIP SEWER 197 L.F.
CONSTRUCT 60" PRECAST CONCRETE MANHOLE PER 1 EA.
CITY STD. DWG. NO. 2001
(D__CONTRACTOR TO CUT AND REMOVE 42" EXISTING STEEL CASING AS NECESSARY 1 F.A.
NECESSARY TO CONSTRUCT MANHOLE
3' MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN.
10' MAX.
6" MAX SIZE NATIVE
SOIL, COMPACTED 90�
6" MIN.
10" MAX.
1" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90X
�l
is
8" VCP/DIP J ' R,' 1
TYPICAL BED= FOR 8' VCP
LESS THAN 10' DEP
3" MAX SIZE NATIVE
SOIL, COMPACTED 95X
6" MIN. 6" MIN.
10" MAX. 10" MAX.
2" I'_:....
6" MAX SIZE NATIVE •
SOIL, COMPACTED 90%
,/r cRusHEro
STONE BEDDING —\
PER STD. SPECS.
FOR PUBLIC WORKS
CONSTRUCTION
TABLE 2BELOW (A,
SHOWN 8" VCP/DIP
oe
0R9F ESS /p%N
J. ,q4l `F
Y �1" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90
ci
o a o
OIN
We •'v IF
r'
TABLE: 200-1.2(A)
SIEVE SIZE
SEWER UNE
— — 8" S—
— EXIST. SEWER LINE
1"
WATER MAIN
8" W
100
STORM DRAIN LINE
90-100
_
= FUTURE STORM DRAIN UNE
NO.4
EXIST. SEWER MANHOLE
Q
SEWER MANHOLE
—
CENTERLINE
FIRE HYDRANT
STREET LIGHT
�—
DIRECTION OF FLOW
— - - — - -
— RIGHT OF WAY
MILLER I AVE
w
GARFIELD DR Q
ADAMS
LN
..............
z
J
FOOTHILL BLVD
AAMMP
N.T.S.
ROJECT LOCATION
ONSTRUCTION NOTES WANUTES
E31 CONSTRUCT 8" EXTRA STRENGTH VCP SEWER MAIN 1,593 L.F.
2 CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 2001 6 EA.
CONSTRUCT 4" EXTRA STRENGTH VCP SEWER LATERAL & CLEANOUT PER 19450 L.F.
CITY STD DWG NO. 2005 (SEE GENERAL NOTE NO. 30)
E64 CONSTRUCT BACKWATER CHECK VALVE 17 EA.
5 CONSTRUCT 8" DIP SEWER 197 L.F.
CONSTRUCT 60" PRECAST CONCRETE MANHOLE PER 1 EA.
CITY STD. DWG. NO. 2001
(D__CONTRACTOR TO CUT AND REMOVE 42" EXISTING STEEL CASING AS NECESSARY 1 F.A.
NECESSARY TO CONSTRUCT MANHOLE
3' MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN.
10' MAX.
6" MAX SIZE NATIVE
SOIL, COMPACTED 90�
6" MIN.
10" MAX.
1" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90X
�l
is
8" VCP/DIP J ' R,' 1
TYPICAL BED= FOR 8' VCP
LESS THAN 10' DEP
3" MAX SIZE NATIVE
SOIL, COMPACTED 95X
6" MIN. 6" MIN.
10" MAX. 10" MAX.
2" I'_:....
6" MAX SIZE NATIVE •
SOIL, COMPACTED 90%
,/r cRusHEro
STONE BEDDING —\
PER STD. SPECS.
FOR PUBLIC WORKS
CONSTRUCTION
TABLE 2BELOW (A,
SHOWN 8" VCP/DIP
oe
0R9F ESS /p%N
J. ,q4l `F
Y �1" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90
ci
o a o
OIN
We •'v IF
r'
TABLE: 200-1.2(A)
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
1 112*
-
1"
-
314!
100
1 IT
90-100
31f"
20-60
NO.4
0-15
NO.8
0-5
ASTM C 131
TEST GRADINGI
B
CITY OF FONTANA, CALIFORNIA
SEWER IMPROVEMENT PLAN
cn �� �� Z °�"" oe v ` TRACT NO 18676-1 f 18676 SCALE:
� No. 36052 m AS NOTED
� Exp. 6/30/12 M DESIGNED �BW BY: E SHEET DATE:
-17 May, 2012
kp�qTF4�`P CHECKED BY: APP ` 0 _ � � „ � � DRAWING NO.: �
Filename: 1:\15947 Young Homes Lime I and II\Lime 11 Tr. 18676\DWG's\FINAL DESIGN\sewer\Phase 1\18676—PHI SEWER 01.dwg