Loading...
HomeMy WebLinkAbout3479-1POLE SGHEDULE ■ 0 5TANDARD MA5TARM5 1 11LUMINAIRE 516NAL MOUNTING PHASE I PED PUSH BUTTON R.5.N.5. 1 PLACEMENT REMARKS G TYPE HT. 516. LUM. H.P.5Y. MAST ARM POLE PED. PHASE LOGATION ME55AH A B A 26A-4-80 35' 40' 15' 250H MA5 MA5 5V -1-T 5P- I -G5 �b 5 Juru a Ave 22' 4' B I -A 10' - - - - T1l- I -T 15P= +G51 �2 H - 22 4' G 2qA-5-80 35' 50' 15' 250H MA5MA5MA5 5V -I -T 5P -1-G5 0 H Gitm Ave 8' 4' F1=20', F2=12' D I -A 10' - - - - TV -24 5P -1-G5 �4 N - 8' 4' E 26A-4-80 35' 45' 15' 250H MA5 MA5 5V -1-T 5P- I -G5 �4 N Juru a Ave 8' 4' F = I6' SIE F I -A 10' - - - - TV -I -T 5P -1-G5 �6 E - 8' 4' G 2qA-5-80 35' 55' 15' 250H MA5 MA5 5V -1-T 5P -I -G5 06 E Gitru5 Ave 22' 4' FI =20', F2=12' H I -A 10' - - - - TV -2-T 15P -1-G51 �&-1 5 - 22' 4' 5EE TRAFFIC 51GNAL GENERAL NOTE #11. INSTALL R.5.N.5. ON POLE SHAFT. SHAFT MOUNTED MAST ARM TO BE CITY FURNISHED, SEE 5P HEADER GUT NEW A.G. 0.10' MIN. TACK GOAT COMPLETE SURFACE BEING PAVED _'4EXI5TIN5 AG 5URFAG I NG �-- 2-5AGK SLURRY M I X (INITIAL POUR TO BE FLUSH WITH 5URROUNDINC SURFACE) � RIGID METAL CO. NOUIT(S) (INSTALLED WITH 18" MIN. GOVER) TRENCH REPAIR DETAIL "D" N.T.S. TRAFFIC 51ONAL C ENERAL NOTES: I. TRAFFIC 51ONAL AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD PLANS AND SPECIFICATIONS, AND THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLB0XE5 SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLE55 SHOWN OTHERHI5E. 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND 5GHEDULING WITH THE SOUTHERN CALIFORNIA E015ON COMPANY HELL IN ADVANCE OF NEED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER IN THE FIELD FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF HORK. 7. ALL VEHICLE HEADS SHALL BE 12" HITH ALL LED INDICATIONS AND LOVERED BAGKPLATE5, ALL PEDESTRIAN HEADS SHALL BE LED MODULES PER THE SPECIAL PROVISIONS. 8. SEE DRAWING 3153 SHEET 12 AND 13 OF 13 FOR SIGNING AND STRIPING HORK. q. ALL 5TREET-CR0551NO CONDUITS THAT CANNOT BE BORED SHALL BE INSTALLED PER DETAIL "D", TH15 SHEET AND THE SPECIAL PROVISIONS. 10. CONTROLLER CABINETS SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS AS DIRECTED BY THE ENGINEER IN THE FIELD. Ii. FOR CITY FURNISHED EQUIPMENT TO BE INSTALLED BY CONTRACTOR SEE THE SPECIAL PROVISIONS 12. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT HITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 1 #10 ILUMINAIRE 1 2 1 2 1 2 1 - I - 2 1 2 1 2 1 2 1 2 1 - CONDUIT SIZE 1 3" 3" 3" 3" 3" 1 4" 1 4" 1 4" 1 4" 1 3" 1 311= 1*1 MAST -ARM MOUNTING CLAMP FOR MODEL 711 OPTICAL DETECTOR DETAIL "B" N.T.S. BARRIER PROPOSED PHASE DIAGRAM i PHASE I PHASE 2 PHASE 3 PHASE 4 MMMONFAI PHASE 51 PHASE ��M"A"A"AL[e][el"A PHASE �eeeee����e �eeeee����ae '.. �eeeee���m��■ 1 #10 ILUMINAIRE 1 2 1 2 1 2 1 - I - 2 1 2 1 2 1 2 1 2 1 - CONDUIT SIZE 1 3" 3" 3" 3" 3" 1 4" 1 4" 1 4" 1 4" 1 3" 1 311= 1*1 MAST -ARM MOUNTING CLAMP FOR MODEL 711 OPTICAL DETECTOR DETAIL "B" N.T.S. BARRIER PROPOSED PHASE DIAGRAM i PHASE I PHASE 2 PHASE 3 PHASE 4 i PHASE 51 PHASE PHASE -11 PHASE � HEADER GUT �^ L _ 1 _ u -40 003' LIP TACK GOAT COMPLETE TRAFFIC 51ONAL CONSTRUCTION NOTES: I '� .�-<. i 41' ' 35' 1 Vis' . 1 i SURFACE BEING PAVED FilINSTALL CITY FURNISHED TYPE q0 CONTROLLER ASSEMBLY (CONTROLLER EQUIPMENT PACKAGE) C BATTERY BACK-UP SYSTEM AND AUXILIARY REQUIRED TO PROVIDE THE OPERATION SHOWN (SEE 51 FOUNDATION TO BE INSTALLED PER CITY STANDARD EQUIPMENT DRAWING 4004. CONNECT SIG PE REQUIREMENTS. OI N5TALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER G I TY OF FONTANA AND SOUTHERN CALIF (SEE SPECIAL PROVISIONS). LOCATE SERVICE ENCLOSURE A MINIMUM OF FROM THE CONTROLLEF F1- 21 INSTALL MODEL711 UNIDIRECTIONAL, 51NCLE CHANNEL OPTICOM DETECTOR PER DETAIL "B", THIS S BY THE ENGINEER IN THE FIELD (SEE SPECIAL PROVISIONS). 4❑ INSTALL CITY FURNISHED MACE SENSOR UNIT PER CITY STANDARD DRAHINC 133 AND AS DIRECTEL ❑INSTALL 3" PVC, CONDUIT HITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVIi_ _ (qOq) 357-6585). VERIFY PHONE NUMBERS AT TIME OF CONSTRUCTION. 1-61 INSTALL 2" CONDUIT WITH 6 PAIR #Iq SIG PER SPECIAL PROVISIONS. ❑ INSTALL 6 - 1.5" SCHEDULE 40 HDPE CONDUITS PER DETAIL "G". THE GONOUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE, AND GREEN. INSTALL ONE (1) INTERCONNECT GABLE (6PR #Iq) IN THE ORANGE CONDUIT. INSTALL PULL ROPE IN THE REMAINING CONDUITS FOR FUTURE GABLE. CONDUIT 5HEEP5 SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS. Fe-)] INSTALL SIGN AS NOTED AND HARDWARE PER CALTRAN5 5TD. PLAN E5 -7N, DETAIL "U". D EXISTING SERVICE CONDUIT AND CONDUCTORS FROM EXI5TING ED15ON UNDERGROUND VAULT. Fol INSTALL P45 PULLBOX (48.5 L x 30.5 H x 30 D), PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS". II CONSTRUCT 4" THICK PGG PAD (15'x 59 ON COMPACTED NATIVE AROUND PROPOSED 51ONAL AND SERVICE CABINETS. F12] GAP TENON FOR FUTURE USE. o RD 0 14 DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE I-800-221-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT WuwTi UP sww i DEPARTMENT OF P LE0END ►� - VIDEO DETECTION CAMERA (PER G I TY OF FONTANA STANDARD DETAIL 133). - REFLECTORIZED NON -ILLUMINATED STREET NAME SIGN (R.5.N.5.) [PER CITY OF FONTANA STANDARD DETAIL 1321. �-� - UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR. I. 'EX15TINO 0.10't -11N. AC 5URFAG I NG ----- f�—i.�" t;c_'t-1 'tV rlu''C t_ M CONDUITS AND 4-5ACK ORANGE -PEA GRAVEL BACKFILL DUCT INSTALLATION AND TRENCH REPAIR DETAIL "G" N.T.5. 11 � c A 111=20' 10 5 0 10 20 40 IN 9