HomeMy WebLinkAbout4923-341
u
11
I C
1 If
CO
6" Sl
3" BYPAS°
TANK
1'/ " DECK SPRAY 5' RETURN
1'/ " MONSTER 5 RETURN --------
1'/ " MONSTER 5 RETURN
11/ " GEYSER RETURN
1'/ " SPRAY TUNNEL RETURN =_
_9
1'/2" MONSTER 5 RETURN r==
1'/ " DOUGHNUT RETURN
__ - -_-_
11/ " SPLIT SPURT RETURN
11/ " SPLIT SPURT RETURN =
11/ " GUSHER RETURN =-
1'/ " SPRAY LOOP TUNNEL RETURN
11/ " GEYSER RETURN
1'/ " STARLET SPRAY RETURN
11/ " MIX'N MATCH 5 RETURN
11/ " STARLET SPRAY RETURN
11/ " SPIN SPLASHER POST RETURN
1'/ ". HO -LEE POST RETURN
11/2 " CANON SPLASH 5LA5TER RETURN
HAZARDOUS
INFORMATION
SIGNAGE
P&
TANK
3" U1P RETURN TO BALANCE TANK
3" WP SUCTION FROM BALANCE TANK
3" SL RETURN TO 5ALANCE TANK
3" SL SUCTION FROM 5ALANCE TANK
MECHANICAL ROOM LAYOUT PLAN
. . . . . . . . . . . . . . . . .
3" 5W
5W STANDPIPE
12
3" 5W
® ® a 0 0
EQUIPMENT LIST (REFER Tr-,) s14EET sL-3 toy REMOTE SLIDE EQuir-Mertr List)
2_ �1 WET PLAY 500STER PUMP: 'PENTAIR' CCMK-I5, i'/2HP, 208V 3PH, RATED AT 345 GPM AT 60 FT. TDH, WITH INTEGRAL STRAINER.
2 ONE (1) TOTAL. (3601bs.)
2 ® WET PLAY CIRCULATION PUMP: 'PENTAIR' UIHISPERFLO, WFK-1213HP, 208/230V 3PN, RATED AT 143 GPM AT 60 FT. TDH, WITH
INTEGRAL STRAINER. ONE (1) TOTAL.
2_ SLIDE CIRCULATION PUMP: 'PENTAIR' UIHISPERFLO, WFK-1213HP, 208/230V 3PN, RATED AT 143 GPM AT 60 FT. TDH, WITH INTEGRAL
2 STRAINER. ONE (1) TOTAL.
1 _ ® WET PLAY FILTERS: 'PENTAIR' TRITON 2-TRIOOC HI -RATE PERMANENT MEDIA FILTERS WITH 3" FACE PIPING AND 3" 5ACKUTASH AT
2 143 GPM FLOW RATE. COMPLETE WITH INFLUENT/EFFLUENT GAUGES, 9.82 SQ. FT. OF FILTER AREA RATED AT 141 GPM AT 15 GPM/SQ.
FT OF FILTER AREA. TWO (2) TOTAL. (600 L55 EA.)
1 0 SLIDE FILTERS: 'PENTAIR' TRITON 2-TRIOOC 1 -11 -RATE PERMANENT MEDIA FILTERS WITH 3" FACE PIPING AND 3" 5ACKUTASH AT 143
GPM FLOW RATE. COMPLETE WITH INFLUENT/EFFLUENT GAUGES, 9.82 SQ. FT. OF FILTER AREA RATED AT 141 GPM AT 15 GPM/SQ. FT
OF -FILTER AREA. TWO (2) TOTAL. (600 L55 EA.)
4_ ®CHLORINE STORAGE/FEED SYSTEM: PROVIDE 'CHEM-TAINER' 350 GALLON 41TC5256DC; DUAL STORAGE/CONTAINMENT TANK WITH
MR 2 MR 2 t111!R!-2 MR_ 2 LID SEISMICALLY RESTRAINED; (2,920bs) COMPLIES WITH FED. REG *40CFR-264-193. SLIDE FEED PUMP SHALL 5E 'STENNER'
85M-5 85 GPD 6 25 PSI WITH FRP SHELF.5RACKET ONE (1) AND WET PLAY FEED PUMP SHALL 5E 'STENNER' 45M-5 50 GPD 6 25
PSI ONE (1) HARD PIPE TO POINT OF INJECTION.
5K 6 8 �C3
-1 ACID STORAGE/FEED SYSTEM: PROVIDE 'CTM-TAINER' 150 GALLON OTC,3448DC: DUAL STORAGE/CONTAINMENT
MR -2 MR -2 MR -2 MR -2 MR -2 �r
TANK WITH LID SEISMICALLY RESTRAINED. C1,�5�vibs). COMPLIES WITH FED. REG 40CFR-264-163. WET PLAY AND
SLIDE FEED PUMPS SHALL 5E 'STENNER' 045M-HP10, 10 GPD o 100 PSI WITH FRP SHELF 5RACKET. TWO (2). HARD
PIPE TO POINT OF INJECTION. PROVIDE A COMPLETE ACID VAPOR RECOVERY SYSTEM.
WET f= -'AY 4 SLIDE WATER CHEMISTRY CONTROLLER= PROVIDE COMPLETE SYSTEM CONTROL PACKAGE. 'BECSYS', 'IMPACT', OR
3 EQUAL. TWO (2) TOTAL.
1 5 ( ELECTRICAL: PROVIDE ALL ELECTRICAL WIRING, CONDUIT, PANEL(S), STARTER/DISCONNECT INTERCONNECT(5) ETC. AS REQUIRED
�MTR-3 MR -3 FOR PROPER EQUIPMENT INSTALLATION PER MANUFACTURERS RECOMMENDATIONS AND SHOP DRAWINGS. COORDINATE ALL
WORK WITH OTHER TRADES AS REQUIRED. REFER TO ELEC. PLANS FOR ALL ADDITIONAL INFO.
2 10 WET PLAY/SLIDE FILL SYSTEM SHALL 5E *124-01AKX-1" AND 1'/2" VALVE WITH NON -CORROSIVE OCFI-CD<X FLOAT CONTROL IN 8"
MR -3 PVC STILLING WELL IN 5ALANCE TANK. 1'/2" LINE SIZE FOR SLIDE 5ALANCE TANK AND 1" FOR WET PLAY 5ALANCE TANK WITH
MANUAL OVERRIDES. TWO (2) TOTAL.
6 11 WET PLAY ULTRA VIOLET SYSTEM: 'WALLACE 4 TIERNAN' 5ARRIER M135, 401 GPM/CAPACITY/FLOW RATE, 5" FLANGED
-3 CONNECTIONS, 1-WTL2000 U.Y. LAMP, U.V. UNIT, JUNCTION BOX AND CONTROL PANEL, SINGLE PHASE, 208V, 6OHZ, 36A FUSING, 225
KVA ACTIVE POUTER CONSUMPTION.
12 5ACKWASH. STANDPIPE: PROVIDE 12" DIA. PVC STANDPIPE PLUS 48" TALL WITH (o" P -TRAP OUTLET TO WASTE.
1 2 13 WET PLAY AUTOMATION: 'WATER PLAY' COMMAND CENTER INCLUDING SYSTEM CONTROLLER, WALL MOUNTED WATER DISTR15UTION
UiP-6 U�-6 MANIFOLDS, WITH EIGHTEEN (18) OUTLETS, SOLENOID VALVES, ISOLATION VALVES, 5OLLARD OPERATED ACTIVATION, COMPLETE.
CONTRACTOR SMALL PROVIDE COMPLETE SHOP DRAWINGS FOR APPROVAL. PROVIDE WINTER DRAIN POINTS ADJACENT TO
EQUIPMENT AREA FOR ALL. MANIFOLD LINES.
14 FLOWMETERS: SLUE WHITE INDUSTRIES 1---300 SERIES wET PLAY= 3", SLIDE= 3", SLIDE RETURNS= 26 8". FOUR (4) TOTAL.
FRP PART I T I ON/CURS
'/2��_1�_0..
POOL MECHANICAL ROOM MOTORIZED EQUIPMENT
ITEM
DESCRIPTION
EQUIPMENT RATING
DISC. SW. SIZE
STARTER SIZE
CIRCUIT DATA
CONDUIT- WIRE
VOLTS
PH.
HP
FLA
MCA
MOCP
U1P
WET PLAY
BOOSTER PUMP
208
3
"1'/2
24.2
30.25
CV =
6OAS/3P
NEMA �
3/4" C.
3#8 4 110 E.G.
5P
F-OPj
WET PLAY
PUMP
206
3
3
10.6
1325
BACKWASH
30AS/3P
NEMA *1
'/2 11C.
312 4 112 E.G.
E?�E]CIRC
FSL__1
SLIDE
CIRC PUMP
208
3
3
10.6
13.25
30AS/3P
NEMA 11
'/2 11C.
312 4 112 E.G.
CP
EQUIPMENT ANCHORAGE NOTE
ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED t0 MEET THE HORIZONTAL AND VERTICAL
FORCES PRESCRIBED IN THE 2010 GSC, AND ASCE 7-015 SECTION 13b.
LEGEND
SV =
BALL VALVE
AI =
ACID INJECTION
SFV -
5U7TEFFLY VALVE
CI
CHLORINE INJECTION
CV =
CHECK VALVE
pH _
PIPE HANGER
Ph'I
FLOWMETER
Fp =
FLOOR DRAIN
WP
WET PLAY
SW -
BACKWASH
SL =
SLIDE
TC =
TIME CLOCK
b m -la
L A N D S C A P E
ARCH ITECTU RE
310 N. JOY STREET
CORONA, CA 92879
T: 951.73 7.1124
F: 951.737.6551
lAl�s�goF
E. M
SIGNATURE n
y
9/30/13
S EXP. DATE \P
CA
CONSULTANT STAMP:
SSD ARC,4
ci�FC'
(P C 22 Q-
R /31/13
OF CAL��0
PROJECT:
MARTIN TUDOR
AQUATIC CENTER
PREPARED FOR:
C I T Y O F
^='` CITY OF FONTANA
C� 16489 ORANGE WAY
FONTANA, CA. 92335
CONTACT: DAN -WEST
PHONE: 909-350-6530
PROJECT TRACKING DATE
1. PROGRESS SET 8-1-11
2. FIRST PLAN CHECK SUBMITTAL 10-3-11
3. SECOND PLAN CHECK SUBMITTAL 11-09-11
4. FOURTH PLAN CHECK SUBMITTAL 01-10-12
5.
6.
7.
8.
DELTA REVISIONS DATE
1.
2.
3.
4.
5.
6.
7.
8.
DATE PREPARED: 01-10-12
DRAWING SCALE:
DRAWN BY: GSF
DESIGNED BY: GSF
CHECKED BY: SJF
BMLA PROJECT NO: 10011210
Q �
O2.1
DIAL TWO WORKING
BEFORE .O DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE 811
A PUBLIC SERVICE BY
UNDERGROUND SERVICE ALERT
A r-,%
Aa'16 U AT I C
DESIGN GROUP
2226 FARADAY AVE., CARLSBAD, CA 92008
Tel 760.438.8400 Fax 760.438.5251
SHEAT DESCRIPTION:
MECHANICAL ROOM
LAYOUT PLAN
CITY OF FONTANA
DRAWN BY: GSF PROJECT NAME
DESIGNED BY: MARTIN TUDOR WATER PARK DATE:
SJF, GSF 11/09/2011 'R
CHECKED BY: APPROVD: ^ , DWG NO.
SJF ER 51152 C.E. 4923 34
37 of
Sheet 10 12