HomeMy WebLinkAbout4923-341 u 11 I C 1 If CO 6" Sl 3" BYPAS° TANK 1'/ " DECK SPRAY 5' RETURN 1'/ " MONSTER 5 RETURN -------- 1'/ " MONSTER 5 RETURN 11/ " GEYSER RETURN 1'/ " SPRAY TUNNEL RETURN =_ _9 1'/2" MONSTER 5 RETURN r== 1'/ " DOUGHNUT RETURN __ - -_-_ 11/ " SPLIT SPURT RETURN 11/ " SPLIT SPURT RETURN = 11/ " GUSHER RETURN =- 1'/ " SPRAY LOOP TUNNEL RETURN 11/ " GEYSER RETURN 1'/ " STARLET SPRAY RETURN 11/ " MIX'N MATCH 5 RETURN 11/ " STARLET SPRAY RETURN 11/ " SPIN SPLASHER POST RETURN 1'/ ". HO -LEE POST RETURN 11/2 " CANON SPLASH 5LA5TER RETURN HAZARDOUS INFORMATION SIGNAGE P& TANK 3" U1P RETURN TO BALANCE TANK 3" WP SUCTION FROM BALANCE TANK 3" SL RETURN TO 5ALANCE TANK 3" SL SUCTION FROM 5ALANCE TANK MECHANICAL ROOM LAYOUT PLAN . . . . . . . . . . . . . . . . . 3" 5W 5W STANDPIPE 12 3" 5W ® ® a 0 0 EQUIPMENT LIST (REFER Tr-,) s14EET sL-3 toy REMOTE SLIDE EQuir-Mertr List) 2_ �1 WET PLAY 500STER PUMP: 'PENTAIR' CCMK-I5, i'/2HP, 208V 3PH, RATED AT 345 GPM AT 60 FT. TDH, WITH INTEGRAL STRAINER. 2 ONE (1) TOTAL. (3601bs.) 2 ® WET PLAY CIRCULATION PUMP: 'PENTAIR' UIHISPERFLO, WFK-1213HP, 208/230V 3PN, RATED AT 143 GPM AT 60 FT. TDH, WITH INTEGRAL STRAINER. ONE (1) TOTAL. 2_ SLIDE CIRCULATION PUMP: 'PENTAIR' UIHISPERFLO, WFK-1213HP, 208/230V 3PN, RATED AT 143 GPM AT 60 FT. TDH, WITH INTEGRAL 2 STRAINER. ONE (1) TOTAL. 1 _ ® WET PLAY FILTERS: 'PENTAIR' TRITON 2-TRIOOC HI -RATE PERMANENT MEDIA FILTERS WITH 3" FACE PIPING AND 3" 5ACKUTASH AT 2 143 GPM FLOW RATE. COMPLETE WITH INFLUENT/EFFLUENT GAUGES, 9.82 SQ. FT. OF FILTER AREA RATED AT 141 GPM AT 15 GPM/SQ. FT OF FILTER AREA. TWO (2) TOTAL. (600 L55 EA.) 1 0 SLIDE FILTERS: 'PENTAIR' TRITON 2-TRIOOC 1 -11 -RATE PERMANENT MEDIA FILTERS WITH 3" FACE PIPING AND 3" 5ACKUTASH AT 143 GPM FLOW RATE. COMPLETE WITH INFLUENT/EFFLUENT GAUGES, 9.82 SQ. FT. OF FILTER AREA RATED AT 141 GPM AT 15 GPM/SQ. FT OF -FILTER AREA. TWO (2) TOTAL. (600 L55 EA.) 4_ ®CHLORINE STORAGE/FEED SYSTEM: PROVIDE 'CHEM-TAINER' 350 GALLON 41TC5256DC; DUAL STORAGE/CONTAINMENT TANK WITH MR 2 MR 2 t111!R!-2 MR_ 2 LID SEISMICALLY RESTRAINED; (2,920bs) COMPLIES WITH FED. REG *40CFR-264-193. SLIDE FEED PUMP SHALL 5E 'STENNER' 85M-5 85 GPD 6 25 PSI WITH FRP SHELF.5RACKET ONE (1) AND WET PLAY FEED PUMP SHALL 5E 'STENNER' 45M-5 50 GPD 6 25 PSI ONE (1) HARD PIPE TO POINT OF INJECTION. 5K 6 8 �C3 -1 ACID STORAGE/FEED SYSTEM: PROVIDE 'CTM-TAINER' 150 GALLON OTC,3448DC: DUAL STORAGE/CONTAINMENT MR -2 MR -2 MR -2 MR -2 MR -2 �r TANK WITH LID SEISMICALLY RESTRAINED. C1,�5�vibs). COMPLIES WITH FED. REG 40CFR-264-163. WET PLAY AND SLIDE FEED PUMPS SHALL 5E 'STENNER' 045M-HP10, 10 GPD o 100 PSI WITH FRP SHELF 5RACKET. TWO (2). HARD PIPE TO POINT OF INJECTION. PROVIDE A COMPLETE ACID VAPOR RECOVERY SYSTEM. WET f= -'AY 4 SLIDE WATER CHEMISTRY CONTROLLER= PROVIDE COMPLETE SYSTEM CONTROL PACKAGE. 'BECSYS', 'IMPACT', OR 3 EQUAL. TWO (2) TOTAL. 1 5 ( ELECTRICAL: PROVIDE ALL ELECTRICAL WIRING, CONDUIT, PANEL(S), STARTER/DISCONNECT INTERCONNECT(5) ETC. AS REQUIRED �MTR-3 MR -3 FOR PROPER EQUIPMENT INSTALLATION PER MANUFACTURERS RECOMMENDATIONS AND SHOP DRAWINGS. COORDINATE ALL WORK WITH OTHER TRADES AS REQUIRED. REFER TO ELEC. PLANS FOR ALL ADDITIONAL INFO. 2 10 WET PLAY/SLIDE FILL SYSTEM SHALL 5E *124-01AKX-1" AND 1'/2" VALVE WITH NON -CORROSIVE OCFI-CD<X FLOAT CONTROL IN 8" MR -3 PVC STILLING WELL IN 5ALANCE TANK. 1'/2" LINE SIZE FOR SLIDE 5ALANCE TANK AND 1" FOR WET PLAY 5ALANCE TANK WITH MANUAL OVERRIDES. TWO (2) TOTAL. 6 11 WET PLAY ULTRA VIOLET SYSTEM: 'WALLACE 4 TIERNAN' 5ARRIER M135, 401 GPM/CAPACITY/FLOW RATE, 5" FLANGED -3 CONNECTIONS, 1-WTL2000 U.Y. LAMP, U.V. UNIT, JUNCTION BOX AND CONTROL PANEL, SINGLE PHASE, 208V, 6OHZ, 36A FUSING, 225 KVA ACTIVE POUTER CONSUMPTION. 12 5ACKWASH. STANDPIPE: PROVIDE 12" DIA. PVC STANDPIPE PLUS 48" TALL WITH (o" P -TRAP OUTLET TO WASTE. 1 2 13 WET PLAY AUTOMATION: 'WATER PLAY' COMMAND CENTER INCLUDING SYSTEM CONTROLLER, WALL MOUNTED WATER DISTR15UTION UiP-6 U�-6 MANIFOLDS, WITH EIGHTEEN (18) OUTLETS, SOLENOID VALVES, ISOLATION VALVES, 5OLLARD OPERATED ACTIVATION, COMPLETE. CONTRACTOR SMALL PROVIDE COMPLETE SHOP DRAWINGS FOR APPROVAL. PROVIDE WINTER DRAIN POINTS ADJACENT TO EQUIPMENT AREA FOR ALL. MANIFOLD LINES. 14 FLOWMETERS: SLUE WHITE INDUSTRIES 1---300 SERIES wET PLAY= 3", SLIDE= 3", SLIDE RETURNS= 26 8". FOUR (4) TOTAL. FRP PART I T I ON/CURS '/2��_1�_0.. POOL MECHANICAL ROOM MOTORIZED EQUIPMENT ITEM DESCRIPTION EQUIPMENT RATING DISC. SW. SIZE STARTER SIZE CIRCUIT DATA CONDUIT- WIRE VOLTS PH. HP FLA MCA MOCP U1P WET PLAY BOOSTER PUMP 208 3 "1'/2 24.2 30.25 CV = 6OAS/3P NEMA � 3/4" C. 3#8 4 110 E.G. 5P F-OPj WET PLAY PUMP 206 3 3 10.6 1325 BACKWASH 30AS/3P NEMA *1 '/2 11C. 312 4 112 E.G. E?�E]CIRC F­SL__1 SLIDE CIRC PUMP 208 3 3 10.6 13.25 30AS/3P NEMA 11 '/2 11C. 312 4 112 E.G. CP EQUIPMENT ANCHORAGE NOTE ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED t0 MEET THE HORIZONTAL AND VERTICAL FORCES PRESCRIBED IN THE 2010 GSC, AND ASCE 7-015 SECTION 13b. LEGEND SV = BALL VALVE AI = ACID INJECTION SFV - 5U7TEFFLY VALVE CI CHLORINE INJECTION CV = CHECK VALVE pH _ PIPE HANGER Ph'I FLOWMETER Fp = FLOOR DRAIN WP WET PLAY SW - BACKWASH SL = SLIDE TC = TIME CLOCK b m -la L A N D S C A P E ARCH ITECTU RE 310 N. JOY STREET CORONA, CA 92879 T: 951.73 7.1124 F: 951.737.6551 lAl�s�goF E. M SIGNATURE n y 9/30/13 S EXP. DATE \P CA CONSULTANT STAMP: SSD ARC,4 ci�FC' (P C 22 Q- R /31/13 OF CAL��0 PROJECT: MARTIN TUDOR AQUATIC CENTER PREPARED FOR: C I T Y O F ^='` CITY OF FONTANA C� 16489 ORANGE WAY FONTANA, CA. 92335 CONTACT: DAN -WEST PHONE: 909-350-6530 PROJECT TRACKING DATE 1. PROGRESS SET 8-1-11 2. FIRST PLAN CHECK SUBMITTAL 10-3-11 3. SECOND PLAN CHECK SUBMITTAL 11-09-11 4. FOURTH PLAN CHECK SUBMITTAL 01-10-12 5. 6. 7. 8. DELTA REVISIONS DATE 1. 2. 3. 4. 5. 6. 7. 8. DATE PREPARED: 01-10-12 DRAWING SCALE: DRAWN BY: GSF DESIGNED BY: GSF CHECKED BY: SJF BMLA PROJECT NO: 10011210 Q � O2.1 DIAL TWO WORKING BEFORE .O DAYS BEFORE YOU DIG YOU DIG TOLL FREE 811 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT A r-,% Aa'16 U AT I C DESIGN GROUP 2226 FARADAY AVE., CARLSBAD, CA 92008 Tel 760.438.8400 Fax 760.438.5251 SHEAT DESCRIPTION: MECHANICAL ROOM LAYOUT PLAN CITY OF FONTANA DRAWN BY: GSF PROJECT NAME DESIGNED BY: MARTIN TUDOR WATER PARK DATE: SJF, GSF 11/09/2011 'R CHECKED BY: APPROVD: ^ , DWG NO. SJF ER 51152 C.E. 4923 34 37 of Sheet 10 12