Loading...
HomeMy WebLinkAbout4923-16d- 0 N LoO \ o O N O \ O O n C \ -00 O rn O 3 00 o O w d" .D 00 v � Op v �j 00 N I E / v N � I E w � I w o 4- Q) U_ -+J N .E a > v O � a co v v _1 J Ir N C Cu Cu u.i Q 0 LIGHTING FIXTURE SCHEDULE LIGHTING FIXTURE GENERAL NOTES: 1. FIXTURES SHALL HAVE APPROPRIATE UL LABEL, DAMP, OR WET AS REQUIRED BY CODES AND ORDINANCES. 2. LIGHTING FIXTURE CATALOG NUMBERS ARE SERIES TYPE ONLY. PROVIDE ALL- NECESSARY HARDWARE AS REQUIRED BY THE SPECIFICATIONS, DRAWINGS, AND PROJECT CONDITIONS FOR A COMPLETE AND OPERABLE INSTALLATION. 3. PRIOR TO ORDERING ANY LIGHTING EQUIPMENT, THE CONTRACTOR SHALL COORDINATE ALL FIXTURE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND CEILING CAVITY DEPTHS. 4. CONTRACTOR SHALL VERIFY FIXTURE VOLTAGES AND CEILING TRIM COMPATIBILITY PRIOR TO ORDERING FIXTURE. 5. PROVIDE APPROVED FIRE -RATED ENCLOSURES FOR ALL LIGHTING FIXTURES LOCATED IN FIRE -RATED CEILINGS. 6. UPON INITIAL ENERGIZING OF ALL NEW FLUORESCENT LAMPS, A CONTINUOUS PERIOD OF 30 HOURS SHALL OCCUR PRIOR TO DE -ENERGIZING OF LAMPS, FOR MANUFACTURER REQUIRED LAMP BURN -IN AND MAXIMUM LAMP LIFE. 7. ENSURE COMPATIBILITY OF ALL LIGHTING SYSTEM COMPONENTS SUCH AS DIMMING SYSTEMS. FIXTURES, LAMPS, BALLAST(S), AND DIMMING SYSTEMS/INDIVIDUAL CONTROLS MUST BE FACTORY CERTIFIED COMPATIBLE FOR FULL RANGE OF DIMMING COMPATIBILITY. 8. PROVIDE CLEARANCES FROM COMBUSTIBLES A MINIMUM OF 1/221 (OTHER THAN AT POINTS OF SUPPORT) AND 3" FROM INSULATION FOR RECESSED LIGHTING FIXTURES WHICH MUST BE NON -IC RATED. 9. PROVIDE A MINIMUM OF TWO (2) #12 SUPPORT WIRES ATTACHED TO BUILDING FRAME IN ADDITION TO T -BAR CLIPS FOR FLUORESCENT FIXTURES RECESSED IN SUSPENDED T -BAR CEILING. 10. PROVIDE (4) SHEET METAL SCREWS, ONE INSTALLED IN EACH CORNER OF THE FIXTURE ATTACHING THE FIXTURE TO THE GRID. SCREWS SHALL NOT BE VISIBLE NOR IMPEDE INSTALLATION OF GRID PANELS. 11. PROVIDE DOOR -TO -FRAME AND LENS -TO -DOOR GASKETING, INVERTED LENS, AND FOOD SERVICE RATING FOR ALL FIXTURES LOCATED IN FOOD SERVICE AREAS. 12. LAMPS SHALL BE PROVIDED AND INSTALLED ACCORDING TO THIS FIXTURE SCHEDULE AND PROJECT SPECIFICATIONS. ENSURE COMPATIBILITY BETWEEN FIXTURE, LAMP AND BALLAST(S). 13. APPROVED LAMP MANUFACTURERS ARE OSRAM SYLVANIA, GE, VENTURE (METAL HALIDE ONLY), AND PHILLIPS - NO EXCEPTIONS. 14. FIXTURES SHALL BE ORDERED WITH APPROPRIATE BALLAST(S) THAT HAVE UL AND CBM LABELS. ALL BALLASTS MUST CONFORM TO TITLE 24 REQUIREMENTS FOR PERFORMANCE AND EFFICIENCY. 15. FLUORESCENT FIXTURES TO BE SUPPLIED WITH "QUICK DISCONNECT" SAFETY BALLAST HARDWARE WHICH ARE UL AND CSA CERTIFIED IN ACCORDANCE WITH NEC 410.73(G) AND CEC 30-308(4). 16. FLUORESCENT AND HIGH INTENSITY DISCHARGE BALLASTS SHALL BE ELECTRONIC TYPE. PROVIDE END OF UFE (EOL) SHUT -DOWN PROTECTION FOR COMPACT FLUORESCENT LAMPS. 17. FIXTURES, TRIMS, REFLECTORS, AND LAMPS SHALL BE CLEANED FREE FROM DIRT, DUST, LABEL ADHESIVE, AND FINGER PRINTS. 18. ALL LIGHT FIXTURES SHALL BE MOUNTED AND SUPPORTED IN ACCORDANCE WITH OSHA STANDARDS AND ALL LOCAL, STATE, AND NATIONAL ELECTRICAL CODES. PROVIDE Al REQUIRED SEISMIC BRACING FOR SUSPENDED LIGHT FIXTURES. 19. PROVIDE LIGHT FIXTURE MOUNTING KITS AS REQUIRED TO SUIT THE EXACT TYPE OF CEILING TO WHICH THEY ARE MOUNTED. 20. COORDINATE FIXTURE AND TRIM FINISHES WITH ARCHITECT PRIOR TO ORDERING. 21. EACH DIMMED CIRCUIT SHALL CARRY A SEPARATE NEUTRAL CONDUCTOR WITH TRACER COLOR TO MATCH PHASE CONDUCTOR. MINIMUM BALLAST AND LAMP COLOR SPECIFICATIONStU.ON3 LAMP COLOR TEMPERATURE LAMP LIFE CRI BALLAST TYPE BALLAST FACTOR MH OR PSMH 40007K VARIES 65 + MAGNETIC 0.90 CMH 3000% VARIES 85 + MAGNETIC 0.90 HPS 2000'K VARIES 20 + MAGNETIC 0.90 T5*, T5HO* 35001x* 20,000 HRS 80 + PROGRAMMED RAPID START 1.00 T8* 35001x* 20,000 HRS 80 + PROGRAMMED RAPID START 0.90 CFL* 35001x* 109000 HRS 80 + PROGRAMMED RAPID START 0.90 *NOTE: COLOR TEMPERATURE IN CORRIDORS, LOBBIES, AND FRONT -OF -HOUSE AREAS TO BE 30001x, U.O.N. EMERGENCY LIGHTING NOTES: 1. ALL FIXTURES INDICATED AS EMERGENCY (EM OR SHADED) SHALL BE PROVIDED WITH EMERGENCY BATTERY PACKS. BATTERY PACKS SHALL BE AS FOLLOWS: - UNEAR T5 FLUORESCENT LAM PS- BODINE#LP600/1250 LUMENS MINIMUM -1 LAMP OPERATION - UNEAR T8 FLUORESCENT LAM PS- BODINE#.850/1350 LUMENS MINIMUM -2/1 LAMP OPERATION - COMPACT FLUORESCENT LAM PS- BODINE#B84C/1 000 LUMENS MINIMUM -2/1 LAMP OPERATION. - COMBINATION TEST SWITCH/CHARGE LIGHT. 2. ALTERNATE OR EQUALS TO BE PRE -APPROVED BY ARCHITECT AND ELECTRICAL ENGINEER. 3. PROVIDE EMERGENCY REFLECTORS OR HOUSINGS WHEN OPTION IS AVAILABLE FROM MANUFACTURER TO ALLOW FOR INSTALLATION OF BATTERY PACKS, TEST SWITCHES, PILOT LIGHTS, ETC. WITHIN FIXTURE. 4. WHEN OPTIONAL EMERGENCY REFLECTORS OR HOUSINGS ARE NOT AVAILABLE, REMOTE BATTERY PACKS, TEST SWITCHES, PILOT LIGHTS, ETC. ARE TO BE INSTALLED IN THE MOST CONSPICUOUS LOCATION AS ALLOWED BY CODE AND LOCAL AHJ REQUIREMENTS. COORDINATE LOCATION WITH ARCHITECT AND/OR ELECTRICAL ENGINEER PRIOR TO ANY ROUGH -IN. 5. ALL NIGHT LIGHTS, BATTERY PACKS AND EXIT SIGNS SHALL CONTAIN AN UNSWITCHED, UNDIMMED, "HOT" CONDUCTOR AND BE IN COMPLIANCE WITH NEC ARTICLE 700. TANDEM WIRING NOTES: 1. PROVIDE MULTIPLE BALLASTS FOR DUAL -LEVEL SWITCHING AND WIRING (i.e. TANDEM) AS INDICATED ON THE PLANS. 2. 3 -LAMP FIXTURES TO BE TANDEM WIRED W/ ELECTRONIC BALLAST CONFIGURATION AS FOLLOWS: - "M" DENOTES MASTER FIXTURE W/ 1-4 LAMP ELECTRONIC BALLAST TO SUPPLY 2 -OUTSIDE LAMPS IN EACH THE "M" & "S" FIXTURE. - "S". DENOTES SLAVE FIXTURE W/ 1-2 LAMP ELECTRONIC BALLAST TO SUPPLY 1 -INSIDE LAMP IN EACH THE "M" & "S" FIXTURE. - "0" DENOTES ODD FIXTURE (NO PAIR) W/ 1-2 LAMP & 1 -LAMP ELECTRONIC BALLAST. SUBSTITUTION NOTES: 1. ALL SUBSTITU11ONS MUST BE APPROVED BY THE ARCHITECT AK ELECTRICAL ENGINEER. PRIOR TO CONSIDERING SUBSTITIONS, THE FOLLOWING MUST BE PROVIDED (15) DAYS PRIOR TO BID TIME: - COMPLETE AND OPERABLE SAMPLES OF SUBSTITUTIONS CONTAINING 120V CORD AND PLUG CONNECTIONS, ALONG WITH CURRENT MANUFACTURER'S DATA SHEETS. - PHOTOMETRIC STUDIES UTILIZING IES STANDARD PHOTOMETRIC DATA AND SOFTWARE FOR THIS PROJECT USING PROPOSED SUBSTITUTION FIXTURES TO ENSURE DESIGN INTENT IS MET. LUMEN OUTPUT AND LIGHT LOSS FACTOR VALUES TO BE DICTATED BY OMB ELECTRICAL ENGINEERS FOR THIS STUDY. - WHEN APPLICABLE, PHOTOMETRIC STUDIES OF EMERGENCY LIGHTING APPLICATIONS FOR ALL REQUIRED AREAS IN THIS PROJECT UTILIZING PROPOSED SUBSTITUTIONS. BATTERY PACK LUMEN OUTPUT VALUES TO BE BASED ON EMERGENCY LIGHTING NOTES CONTAINED HEREWITH. GENERAL NOTES & SPECS. 1. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO ACHIEVE A COMPLETE AND OPERATIONAL SYSTEM. 2. COORDINATE AND OBTAIN APPROVALS FROM ALL RESPECTIVE UTILITY COMPANIES AS REQUIRED FOR A COMPLETE AND FUNCTIONAL INSTALLATION. 3. INSTALL RACEWAY SYSTEMS AS FOLLOWS: a. USE RIGID GALVANIZED STEEL IN ALL AREAS EXPOSED TO WEATHER OR PHYSICAL DAMAGE. b. USE FLEXIBLE METALLIC CONDUIT ONLY IN AREAS AS PERMITTED BY LOCAL CODE AUTHORITY. USE SEAL -TITS IN AREAS EXPOSED TO WEATHER. c. USE COMPRESSION TYPE FITTINGS FOR ELECTRICAL METALLIC TUBING WHERE UTILIZED. d. USE P.V.C. CONDUIT UNDERGROUND WITH CODE SIZED GROUND. CONDUIT RISERS AND STUBS ABOVE GRADE SHALL BE I.M.C. WITH HALF -LAPPED TAPE COVERING OR P.V.C. COATING. 4. ALL NEW WIRING SHALL BE COPPER TYPE "THHN/THWN" - U.O.N.. 5. CONDUIT FOR ROOF MOUNTED EQUIPMENT SHALL BE ROUTED BELOW THE ROOF WITHIN THE BUILDING. 6. ALL FIXTURE, DEVICE, ETC.. LOCATIONS SHALL BE VERIFIED WITH ARCHITECTURAL DRAWINGS AS WELL AS EQUIPMENT SUPPLIER REQUIREMENTS PRIOR TO ANY ROUGH -IN WORK. 7. ALL LIGHTING FIXTURES SHALL BE MOUNTED AND SUPPORTED IN ACCORDANCE WITH OSHA STANDARDS AND ALL LOCAL, STATE, AND NATIONAL ELECTRICAL CODES. 8. ELECTRONIC BALLASTS FOR FLUORESCENT LIGHTING FIXTURES SHALL HAVE A MINIMUM BALLAST FACTOR (BF) OF 0.90 OR GREATER UNLESS OTHERWISE SPECIFIED. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE LIGHTING FIXTURE MOUNTING KITS AS REQUIRED TO SUIT THE EXACT TYPE OF CEILING TO WHICH THEY ARE MOUNTED. 10. THESE DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE INTENT OF EQUIPMENT, DEVICES, ETC... TO BE CONNECTED AND THE CIRCUITS TO WHICH THEY ARE TO BE CONNECTED TO. CONTRACTOR SHALL INSTALL ALL CONDUIT, J -BOXES, ETC... AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. 11. ALL EXTERIOR EQUIPMENT SHALL BE WEATHERPROOF. 12. ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL GOVERNING CODES. 13. ALL EQUIPMENT SHALL BE NEW AND BEAR A "UL" LABEL - U.O.N.. 14. ELECTRICAL CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY BUILDING PERMITS. 15. COMPLETE ELECTRICAL INSTALLATION SHALL BE GUARANTEED IN WRITING FOR A PERIOD OF (1) YEAR - U.O.N.. 16. ELECTRICAL CONTRACTOR SHALL INCLUDE IN BID - COSTS FOR ALL HVAC CONTROL COMPONENTS, CONDUITS, DEVICES, ETC... AS DEEMED NECESSARY FOR A COMPLETE AND OPERATIONAL HVAC SYSTEM. REFER TO MECHANICAL DRAWINGS, DIAGRAMS AND SPECS FOR THOSE ITEMS REQUIRED UNDER THE ELECTRICAL SECTION OF THIS CONTRACT. 17. ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID DATE, TO VERIFY ALL EXISTING CONDITIONS TO BE ENCOUNTERED IN THE INSTALLATION OF ALL NEW EQUIPMENT, FIXTURES, DEVICES, FEEDERS, ETC.. EXACT INSTALLATION METHOD AND REQUIREMENTS SHALL BE VERIFIED AND DETERMINED PRIOR TO BID DATE. CONTRACTORS SHALL IMMEDIATELY NOTIFY THIS ENGINEER OF ANY REQUIRED MODIFICATIONS WHICH ARE NOT SHOWN ON THESE DRAWINGS. SUBMITTAL OF BID INDICATES CONTRACTOR IS AWARE OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED. 18. ALL ELECTRICAL EQUIPMENT CHARACTERISTICS, LOCATIONS, AND CONNECTION REQUIREMENTS SHALL BE VERIFIED PRIOR TO ANY ROUGH -IN WORK. 19. ELECTRICAL CONTRACTOR SHALL FURNISH THE FOLLOWING SHOP DRAWINGS FOR PRIOR APPROVAL: a. ALL SUBSTITUTED LIGHT FIXTURES. b. ALL ELECTRICAL SERVICE EQUIPMENT, DISTRIBUTION EQUIPMENT AND PANELBOARDS. c. OTHER ITEMS AS SPECIFICALLY INDICATED. THESE ITEMS SHALL BE APPROVED BY,, THIS OFFICE PRIOR TO ANY COMMENCEMENT OF PLACING ORDERS OR PERFORMING ANY ROUGH -IN WORK. 20. COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH THE PRESENTLY ADOPTED EDITION OF THE N.E.C. ART. 250. 21. PENETRATIONS OF ALL FIRE RATED WALLS OR CEILINGS SHALL BE FIRE RATED IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL CODES. 22. PROVIDE ENGRAVED PLASTIC NAMEPLATES FOR ALL MAJOR ELECTRICAL EQUIPMENT. 23. PROVIDE THE OWNER AND THIS ENGINEER WITH ONE SET OF ELECTRICAL "AS-BUILTS" AT THE COMPLETION OF JOB. 24. ALL DISCONNECT SWITCHES TO BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS. 25. ELECTRICAL CONTRACTOR SHALL PREPARE AND SUBMIT CALIFORNIA ENERGY COMMISSION TITLE 24 FORMS LTG -1-A, PARTS 1, 2, & 3 (CERTIFICATE OF ACCEPTANCE) AND FORMS LTG -2-A (LIGHTING CONTROL) AND/OR LTG -3-A (AUTOMATIC DAYLIGHTING CONTROL) AS THEY APPLY TO THE BUILDING DEPARTMENT PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. ELECTRICAL SYMBOLS LIST SURFACE MOUNTED FLUORESCENT WRAPAROUND TYPE LIGHTING FIXTURE. "EM" AND/OR SHADED CONNECTION POINT INDICATES FIXTURE WITH EMERGENCY BATTERY NL PACK (MINIMUM 1100 LUMEN OUTPUT). "NL" INDICATES FIXTURE ON NIGHT LIGHT CIRCUIT. FO WALL MOUNTED LIGHTING FIXTURE. �Q FLOOD LIGHTING FIXTURE. STANDARD 20A, 120/277V-10 SPST TOGGLE SWITCH MOUNTED AT +48" A.F.F.-U.O.N. a,b - DENOTES TWO SWITCHES AND THEIR RESPECTIVE CONTROL IDENTIFICATION. 3 - DENOTES 3 -WAY SWITCH - DENOTES - 120V. - 10 (AS NOTED) SLIDING TYPE DIMMER SWITCH. - LUTRON "NOVA -T" SERIES OR APPROVED EQUAL, PROVIDE SEPARATE NEUTRAL FOR EACH DIMMER AND DIMMER RACK CIRCUIT. m WALL MOUNTED INFRA -RED OCCUPANCY SENSOR. USE WATTSTOPPER "WI 200" FOR SINGLE SWITCH AND "WI 300" FOR "ab" SWITCHING OR EQUAL. STANDARD 20A, 120V-1 0 GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED. AT +18" A.F.F. - U.O.N. q? STANDARD 20A, 120V-10 GROUNDING TYPE "GROUND FAULT INTERRUPTER" (G.F.I.) RECEPTACLE MOUNTED AT +18 A.F.F. U.O.N. �j SPECIAL RECEPTACLE MOUNTED AT +18" A.F.F. - U.O.N.. AMPS - VOLTS &- PHASE AS INDICATED ON PLANS. VERIFY NEMA CONFIGURATION WITH INSTALLED EQUIPMENT SUPPLIER PRIOR TO PLACING ORDER. FUSED DISCONNECT SWITCH. AMPS, POLES AND CLASS RK1 FUSE (SIZE AS INDICATED). OPEN- INDICATES NON-FUSED W.P. - INDICATES NEMA 3R ENCLOSURE ® MAGNETIC MOTOR STARTER. POLES AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. Lo COMBINATION DISCONNECT SWITCH/MAGNETIC MOTOR STARTER. AMPS, POLES, CLASS RK1 FUSE (SIZE AS INDICATED), AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE MANUAL MOTOR STARTER SWITCH. HORSEPOWER RATED -120V - 10 -U.O.N. PROVIDE M COMPLETE WITH THERMAL OVERLOAD PROTECTION. O JUNCTION BOX. SIZED BY THE CONTRACTOR PER ACTUAL NUMBER OF CONDUITS AND/OR CONDUCTORS PASSING THRU. MOTOR OUTLET. H.P. OR F.L.A. - VOLTS & PHASE AS INDICATED. VERIFY ELECTRICAL CHARACTERISTICS AND CONNECTION REQUIREMENTS WITH INSTALLED EQUIPMENT MFG. PRIOR TO ANY ROUGH -IN WORK. ® SERVICE ENTRANCE OR DISTRIBUTION EQUIPMENT AS SPECIFIED. BRANCH CIRCUIT PANELBOARD. FLUSH OR SURFACE MTD. AS INDICATED. ©4 CAMERA OUTLET. - CONDUIT CONCEALED WITHIN BUILDING WALLS OR CEILING SPACE. TICK MARKS INDICATE QUANTITY OF #12 THHN / THWN CONDUCTORS - U.O.N.. CONDUIT SHOWN WITH NO TICK MARKS INDICATE 2 #12 THHN / THWN CONDUCTORS - U.O.N.. CONDUIT SHALL BE 3/4" MINIMUM - U.O.N.. CONDUIT ROUTED BELOW FINISHED GRADE AND / OR CONCRETE SLAB. TICK MARKS INDICATE QUANTITY OF #12 THHN / THWN CONDUCTORS - U.O.N.. CONDUITS SHOWN WITH NO TICK MARKS INDICATE 2 #12 THHN / THWN CONDUCTORS - U.O.N.. CONDUIT SHALL BE 3/4" MINIMUM - U.O.N.. INCLUDE CODE SIZED COPPER BOND CONDUCTOR (NOT SHOWN ON PLAN) IN ALL NON-METALLIC CONDUIT RUNS. INDICATES GREEN CODE SIZE EQUIPMENT GROUNDING CONDUCTOR. HOMERUN TO DESTINATION AS INDICATED. REFER TO CONDUIT SYMBOL ABOVE. -� INDICATES CONDUIT DROP WITHIN BUILDING WALL. REFER TO CONDUIT SYMBOL ABOVE. ----0 INDICATES CONDUIT RISER WITHIN BUILDING WALL. REFER TO CONDUIT SYMBOL ABOVE. FLEXIBLE CONDUIT CONNECTION FROM JUNCTION BOX. nita L A N D DAB SET S C A 10-3-11 P E ARCH 01-12-12 5. ITECTU 6. 7. RE 310 N. JOY STREET CORONA, CA 92879 T: 951.737.1124 F: 951.737.6551 E. k1j SIGNATURE rn 9/30/13 EXP. DATE P �9TF OF CA `\�0�� MARTIN TUDOR AQUATIC CENTER RENOVATION PROJECT PF C I T Y O F CITY OF FONT 1±>L, F 01\! T. I\I A, 0 . PI---IOfl►L: 909-'31-0-6530 PROJECT TRACKING DATE 1. PROGRESS SET 8-1-11 2. DAB SET 8-18-11 3. FIRST PLAN CHECK 10-3-11 4. 4th PLAN CHECK 01-12-12 5. 6. 7. 8. DELTA REVISIONS DATE 1. 2. 3. 4. 5. 6. 7. 8-16-11TYPE MANUFACTURER CATALOG LAMP QTY. & TYPE BALLASTWAn.AOE VOLTS REMARKS HUBBELL OUTDOOR LIGHTING POLE MOUNTED FLOODLIGHT NTH WIDE DISTRIBUTION A 1 TED #MVK-1000H-268 ME1000WATT PULSE START WITAL HALIDE 4000K HIGH POWER FACTOR 1080 208 ON A 50' ROUND TAPERED STEEL POLE, REFER TO 1080 OR APPROVED EQUAL POLE DETAILS ON SHEET EO.03. C) I :, F; OMB B HUBBELL OUTDOOR LIGHTING (1) 400WATT PULSE START POLE MOUNTED SECURITY FLOODLIGHT WITH WIDE MWK #MHS-K40OP8 METAL HALIDE 4000K HIGH POWER FACTOR 461 208 DISTRIBUTION ON ROUND TAPERED STEEL POLE, 1_ > [:= k-, I'd F I F'; 461 OR APPROVED EQUAL REFER TO POLE DETAILS ON SHEET EO.03. �pi COLUMBIA LIGHTING 2 F32 -TS SURFACE 8' ENCLOSED AND GASKETED FIBERGLASS } I E i :. [_ E VHB#LUN8-132-E-U (2) F ELECTRONIC 62 120 INDUSTRIAL FLUORESCENT LIGHT FIXTURE WITH OR APPROVED EQUAL IMPACT -RESISTANT ACRYLIC DIFFUSER. REFERENCES & ABBREVIATIONS SHEETINDEX 10011210 _ KIM LIGHTING (1) 100WATT PULSE START POST TOP MOUNTED LIGHT FIXTURE WITH TYPE 5 122 ORMAPPROVED EQUALO/DB-P METAL HALIDE 4000K HIGH POWER FACTOR 122 120 FOL.E,IBKIM UTIOLIGHT1NG #KRSN ON ROUND N6 4120P/FM/DB ERED STEEL LIGHTING FIXTURE DESIGNATION (ER) EXISTING TO BE REMOVED EO.01 SYMBOLS LIST, GENERAL NOTES & ABBREVIATIONSKF7 Q EO.02 SINGLE LINE DIAGRAM AND PANEL SCHEDULES DETAIL REFERENCE FLA FULL LOAD AMPS EO.03 DETAILS , E0.04 TITLE 24 _---�. /iN•rNJ',", MN1AMfJ\1M �,i``•.��� i1 M'/Y'WLWVt''J4\'''lMR I KEYNOTE REFERENCE G GROUND ED1.10 DEMOLITION ELECTRICAL SITE PLAN E1.10 PARTIAL ELECTRICAL SITE PLAN ���'`- - 1 '{ B F0RE 0 123 KITCHEN EQUIPMENT DESIGNATION GFI GROUND FAULT INTERRUPTER E1.11 ENLARGED ELECTRICAL SITE PLAN ->I Q � ._ _ DIG `. ,., ` •:,:., , E1.12 NIGHT USE LIGHTING PHOTOMETRICS R T TOLL FRE �``�--��'� 811 i A AMPS MCB MAIN CIRCUIT BREAKER E1.13 SECURITY LIGHTING PHOTOMETRICS 4.. PUBLIC SERVICE B tANDERGROUND SEf?VICE ALE.'-',I- AFC LERTAFC ABOVE FINISHED COUNTER MLO MAIN LUGS ONLY AFF ABOVE FINISH FLOOR NL NIGHT LIGHT C CONDUIT OC ON CENTER CO CONDUIT ONLY W/PULL ROPE LION UNLESS OTHERWISE NOTED CU COPPER V VOLTS (E) EXISTING TO REMAIN VL VERIFY LOCATION LTS EM EMERGENCY;_ WP WEATHERPROOF OMB ELECTRICAL ENGINEERS, INC. Gn. y 25 Research Drive SYMBOLS LIST, 023 FEEDER TAG 88Irvine, CA 92618 (949) 753-1553 Fax (949) 753-1992 GENERAL NOTES E -Mail: mail®ombengrs.com OMB PM: VB JOB N0: 11184 & ABBREVIATIONS CITY OF FONTANA DRAWN BY: PROJECT NAME OMB MARTIN TUDOR WATER PARK DESIG NED BY: DATE E0001 MWK 8/18/2011 gm CHECKED BY: PPROV DWG NO. 16 4923CI IN 51152 R.C.E.�j 37 • Sheet 1 of 9