1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT,
ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO
WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL
AT ALL TIMES.
3. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM TWELVE FOOT
LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
4. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE
"W.A.T.C.H. MANUAL", LATEST EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
5. THE CONTRACTOR SHALL MAINTAIN TWO WAY TRAFFIC WITH 12' MINIMUM LANE WIDTHS AT ALL TIMES UNLESS OTHERWISE APPROVED
BY THE CITY ENGINEER. QUALIFIED FLAGGERS SHALL BE USED WHEN THE ROADWAY IS REDUCED TO A SINGLE LANE OR WHERE
TRAFFIC MUST STOP FOR MOVEMENT OF EQUIPMENT.
6. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC
CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
7. THE EXACT LOCATION OF ALL TRAFFIC CONTROL DEVICES IS SUBJECT TO APPROVAL BY THE CITY TRAFFIC ENGINEER.
ADDITIONAL WARNING, CONSTRUCTION SIGNS OR TRAFFIC SAFETY EQUIPMENT MAY BE REQUIRED BY THE CITY TRAFFIC ENGINEER.
8. ALL WORK AREAS SHALL BE CLEARLY IDENTIFIED AND DELINEATED WITH CONES, PORTABLE DELINEATORS AND/OR BARRICADES:
ALL DELINEATORS SHALL BE A MINIMUM OF 36 INCHES IN HEIGHT, ALL CONES SHALL BE A MINIMUM OF 28 INCHES IN HEIGHT.
9. ALL SIGNS SHALL BE REFLECTORIZED OR ILLUMINATED.
10. SIGNS SHALL NOT BE PLACED IN EXCESS OF 15 FEET FROM THE EDGE OF THE TRAVELED WAY. PORTABLE SIGN STANDARDS
SHALL BE TIED DOWN OR WEIGHTED TO PREVENT TOPPLING IN ACCORDANCE WITH W.A.T.C.H. MANUAL REQUIREMENTS.
11. ALL EXISTING SIGNS, STRIPING OR PAVEMENT MARKINGS THAT ARE IN CONFLICT AND/OR NO LONGER APPLICABLE SHALL BE
REMOVED.
12. THE WORK ZONE SHALL BE ROUTINELY INSPECTED AND MAINTAINED TO ENSURE PROPER VISIBILITY AND OPERATION OF ALL
TRAFFIC CONTROL AND ADVANCE WARNING DEVICES.
13. ALL FLASHING YELLOW WARNING LIGHTS SHALL BE TYPE "A" PORTABLE, LENS DIRECTED, ENCLOSED AND MOUNTED AT A
MINIMUM HEIGHT OF THREE FEET, MEASURED FROM THE BOTTOM OF THE LENS TO THE UNDERLYING SURFACE.
14. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING
DETOURS.
15. TRAFFIC SIGN DIMENSIONS, COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATION SHEETS.
SIGN CODES SHOWN HEREON ARE TO CONFORM TO CALTRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE
STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS.
16. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY
STANDARD DETAIL 139.
17. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE W.A.T.C.H. MANUAL. CONSTRUCTION SHALL BE STAGED AS REQUIRED
TO MAINTAIN TRAFFIC FLOW.
18. FOR LATERALS THAT EXTEND BEYOND CONSTRUCTION AREAS SHOWN, USE "W.A.T.C.H. MANUAL", INCLUDING STAGING AND
FLAGGING.
19. CONFLICTING STRIPING/MARKINGS TO BE REMOVED BY METHOD AS DESCRIBED BY THE SPECIAL PROVISIONS, SECTION E.
20. TEMPORARY TRAFFIC SCREEN SHALL BE INSTALLED ON TEMPORARY RAILING PER CALTRANS STANDARD PLANS PAGE T4
EXCEPT WHERE SIGHT DISTANCE IS RESTRICTED BY SUCH SCREENING, AND AS APPROVED BY THE ENGINEER.
TEMPORARY RAILING
(TYPE K) --\
CRASH CUSHION PER
CALTRANS STD. PLAN
T2, ARRAY 'TJ' —\
10:1
LEGEND
I—I
TYPE III BARRICADE (2 AT EACH
END CONSTRUCTION
LOCATION) WITH TYPE N MARKER,
C2
C3A SIGN, AND FLASHER
®
TYPE K BARRICADE
®
CONSTRUCTION AREA
CONSTRUCT 3" TEMPORARY ASPHALT
SAD
CONCRETE PAVEMENT OVER NATIVE BASE
-u-
EXISTING SIGNS
ITm pAmr ROAD CLOSED TO THRU TRAFFIC
PROPOSED CONSTRUCTION SIGN & POST
T
SPECIAL SIGN
�O
TRAFFIC SIGNAL
•
DELINEATORS
DETOUR
FIXED TUBE DELINEATORS
�—
DIRECTION OF TRAFFIC FLOW
«<
TYPE I FLASHING ARROW BOARD
C21
SOLAR POWERED
®
HIGH LEVEL WARNING DEVICE
<8>
FLAGGER
FLASHING BEACON
N.S.
NO STOPPING ANYTIME
C9A
<i>
m
C1
°°
END CONSTRUCTION
DETOUR AHEAD
C2
m
c
a
ROAD CLOSED
ROAD WORK SPEED LIMIT 25
C3
SAD
`
LOCAL TRAFFIC ONLY
C3A
ITm pAmr ROAD CLOSED TO THRU TRAFFIC
C5(L)
®
a
DETOUR
C5(R)
o�
®
DETOUR
cm
< >
RIGHT LANE CLOSED AHEAD
MOM
Cm
C5(ST) ®
C21
DETOUR
C7
C30
<8>
END DETOUR
m
C36
C9A
<i>
m
R1
FLAGGER AHEAD
/llllll�& 00 0 M
C13
°°
END CONSTRUCTION
m
C17
rJ1251
Immm
ROAD WORK SPEED LIMIT 25
C18
`
ROAD CONSTRUCTION AHEAD
C19
ROAD CLOSED AHEAD
C20(L)
LEFT LANE CLOSED AHEAD
C20(R)
cm
< >
RIGHT LANE CLOSED AHEAD
Cm
C21
SINGLE LANE AHEAD
C30
<8>
LANE CLOSED
C36
<t>
PREPARE TO STOP
R1
STOP
STOP
A
R7
KEEP RIGHT SYMBOL
R16
v
®
NO RIGHT TURN
R17
0
®
NO LEFT TURN
m
R18
Rur I
nR,
RIGHT LANE MUST TURN RIGHT
R26
N
TEMPORARY NO PARKING ANY TIME
p RICHT
R41
am
RIGHT TURN ONLY
I- 7EF71
R42am
LEFT TURN ONLY
W1 (L)
< >
DIRECTIONAL SIGN
W1 (R)
<Z>
DIRECTIONAL SIGN
W6(XX) XX
CONSTRUCTION SPEED LIMIT
W19
<9>
END PAVEMENT
W47
n
R R
RR CROSSING (SYMBOL)
W56
N
®
DIRECTIONAL SIGN
W57(L)
®
DIRECTIONAL SIGN
W57(R) ®
DIRECTIONAL SIGN
STRIPING NOTES
LLJ
O
Lu
Uj
U)
I
LLJ
z
U
Santa Ana ►venue
46' 46'
T8 12,
11'
H
LL
W
J
0
J
W
In
W
W
Z
J
Z
U
H
a
�-I GRAPHIC SCALE 0— INSTALL TEMPORARY DOUBLE YELLOW INSTALL TEMPORARY STOP STENCIL _ 46' 46'
d- 40 0 20 40 80 160 STRIPE AND PAVEMENT MARKERS PER PER CALTRANS STD. PLAN A24D.
F2] CALTRANS STD. PLAN A20A, DETAIL 22. FAPPROVED:
TY OF SAN BERNARDINO
Santa Ana Avenue
cfl 40 28 2� INSTALL TEMPORARY 4 WHITE EDGELINE 4�— INSTALL TEMPORARY 12 WHITE LIMIT
( IN FEET) PER CALTRANS STD. PLAN A20B, DETAIL LINE PER CALTRANS STD. PLAN A24E.
CRASH CUSHION DETAIL. 1 �°h = 40 gt. 27B.
SCALE: 1 "=20' SCALE: 1 "=40' TRAFFIC DIVISION
Underground service Alert L.D. KING INC.SH OULD CONSTRUCTION OF THE CITY OF F CALIFORNIA
SECTION 4216/4217 OF THE GOVERNMENT ESS
SU TE CONCONVENTION CENTER WAY TRAFFIC CONTROL FOR REQUIRED IMPROVEMENTS NOT CHERRY AVEN U E
FORE CODE REQUIRES A DIG ALERT IDENTIFICATION RFF ONTARIO CA 91764 COMMENCE WITHIN TWO YEARS OF THE
o Y o NUMBER BE ISSUED BEFORE A PERMIT TO cam' Lr)4cin (909) 937-0200 STORM DRAIN IMPROVEMENTS DATE OF APPROVAL SHOWN HEREON DRAWN BY: CHERRY AVENUE STORM DRAIN SCALE:
No. 16434 AND CARRIED FORTH IN A DILIGENT PS
EXCAVATE WILL BE VALID � � FOR CHERRY AVE. AND SLOVER AVE. AS SHOWN FOR YOUR DIG ALERT I.D. NUMBER CALL * Exp. 6/30/05 MANNER, THE CITY ENGINEER MAY DESIGNED BY: TRAFFIC CONTROL DATE:
UNDERGROUND SERVICE ALERT �qT CIV��-ods' � ,Z� �s REQUIRE REVISIONS TO THE PLANS TO PS OCTOBER 2005
FCHERRYAVENUE BRING THEM INTO CONFORMANCE WITH CHECKED BY: APPROVED BY: DATE: DRAWING NO.:
710 OFCA�
TOLL FREE 1-800-227-2600 CARL J. FREEMAN, R.C.E. No. 16434 DATE CONDITIONS AND STANDARDS IN EFFECT. SCR $ 05 2895
TWO WORKING DAYS BEFORE YOU DIG REV. REVISION DESCRIPTION DATE ENGR. CITY DATE EXPIRES 6-30-05 CITY TRAFFIC ENGINE R.T.E. No. 1931
JN 12414 City of Fontana
Mylar: 10/17/03
File: E:\dwg\12414\Cherry\12407ASD10.dwg 11/14/00