HomeMy WebLinkAbout2894-19PIPE O.D. WIDTH OF DUCT B TRENCH WALLS MAY 5" 4" TYP. + 8" NONEXISTIMETALLIC 4" TYP. NG + 8" -III �III� PIPELINE - - ENON—MXISTING BE SLOPED -1 I E MIN. 1-1 _� 1.5 PIPE DIA. 1�2" THICK ❑ ❑ ' PPELINEALLPIPE DIA.+ 8 MIN.( )EPANSION EXISTING POWER ❑ ❑ INITIAL :III II II 12„ I I I= JOINT FILLER OR TELEPHONE ❑ ❑ BACKFILL -1 I I 1=1 MIN. =I I : ;: : 'r ::: • =I I PIPE DIA./6 MATERIAL DUCT a a ° a . - -11 III- I I • • • •` _ •� • (5 MIN.) » ° .aa- �. � • °�° • 18 MAX. 560-B-3250 REINFORCED a. 18 MAX. 1/2" THICK III I-1 REINFORCED - �, ° = CONCRETE SUPPORT / CONCRETE OR SLURRY II : ° III— —I I a:: d . —I I ° PREFORMED a MIX 1000 P.S.I. MIN. -1I Q d ° 1=1 CONCRETE Q d a ° ( ) _ ���Q' : ' .� 111= _ ° O�Q- i ii EXPANSION -III ;_ IEI PIPE DIA. —I I : r a -� JOINT MATERIAL 111=I= BETWEEN PIPE ° CAREFULLY PLACED GRANULAR =III •° ° - =.1=1 =II . =II AND CONCRETE �.{{�_�� (� EMBEDMENT* COMPACTED =1 I : ,.: , 111= I I , : • '- `00`� o��o r PER SPECIFICATION 11111 0�0 0 III- PIPE DIA./8 =1 I�.; ; =I I PIPE DIA./4 II �o�0 1=1_ (4" MIN.) I i �': f _ . .:• I- (4 MIN.) I '- ........... UNDISTURBED UNDISTURBED --� RM 1 �� �I I I� �I I I� �I I I� 11-111-111-I I II IEARTH --i i- -i i- B EARTH I _1 I I _1 LOAD FACTOR: 2.7 LOAD FACTOR: 4.5 NOTE: THIS TYPE OF CONSTRUCTION REQUIRES THE CONCRETE TO EXTEND NOTE: THIS TYPE OF CONSTRUCTION SHOULD BE DESIGNED BY FROM THE PIPE TO THE TRENCH WALL. CAUTION: NOT RECOMMENDED A REGISTERED STRUCTURAL ENGINEER, AND MAY YIELD SECTION B—B WHERE NATIVE SOILS ARE EXPANSIVE. HIGHER LOAD FACTORS THAN INDICATED. _ CASE 1- CLASS A-111 SIDECRADLING CLASS A -IV NO SCALE CONCRETE ENCASEMENT / � i. NOTES W 1. WIDTH OF BEAM SHALL EQUAL O.D. + 8" OF SUPPORTED PIPE. 6"MIN. 6"MIN. % > / EXISTING C 0 2. IF SUPPORTED PIPE IS BEDDED IN CONCRETE, BEAM WIDTH SHALL BE EQUAL BEDDING WIDTH. 1 0" #4 BAR MAX. 10"MAX. CONDUIT TO U 3. IF BEAM IS PRECAST, ENDS OF BEAM SHALL BE FULLY BEDDED IN 420-C-2000 CONCRETE ,— BE SUPPORTED uj (IF BEAM IS PRECAST) FOR LENGTH 'B'. THE BEDDING SHALL HAVE A MINIMUM THICKNESS OF 4". CLASS 'C' MORTAR M1 ( =1 I—I I HAD C I I REINFORCEMENT - SHALL BE PLACED BETWEEN TOP OF BEAM AND SUPPORTED PIPE TO PROVIDE MINIMUM BEARING SHOWN. I HAND PLACED �- N z I �- N ? SEE TABLE 4. THIS CASE IS PERMITTED ONLY IF THE TRENCH WALLS ARE FIRM AND UNYIELDING. =I I COMPACTED BACKFILL -� I =I I COMPACTED BACK L 04 i -I- 5. MAXIMUM SPACING OF BARS SHALL BE 4" 0. C. -I (O -� N B S B REINFORCED CONCRETE BEAM DIMENSIONS AND REINFORCEMENT) c6O cy I- I I �- PIPE DIA./6 CAREFULLY PLACED GRADED GRAVEL =I I �o o =� I m CAREFULLY PLACED GRADED GRAVEL =I I EMBEDMENT COMPACTED I I raj I= EMBEDMENT COMPACTEDDo PER AGENCY'S STANDARD _I I �o o = PER AGENCY S STANDARD O II I �c�o o �- 560 - B - 3250 C SPECIFICATIONS I 1 �o�o �� I PIPE DIA./8 SPECIFICATIONS I i �p�p �� I PIPE DIA./8 REINFORCED 0. =III =; ; i=1 I 1=� _ =III= I I (4 MIN.) UNDISTURBED =1 I 1=1 (4 MIN.) CONCRETE BEAM UNDISTURBED —„,—,,,— EARTH —oll Il��111,�0 EARTH CLASS B CLASS C LOAD FACTOR 1.9 LOAD FACTOR 1.5 *GRANULAR EMBEDMENT: NOTES COARSE GRAINED NATIVE SOILS OR IMPORTED SAND 1. SLAG, PEA GRAVEL, OR OTHER ALTERNATIVE MATERIALS WILL NOT BE ACCEPTABLE IN LIEU OF GRANULAR WITH A MINIMUM SAND EQUIVALENCE OF 30 AND OF EMBEDMENT. MIN. BEARING SHALL BE U SUCH SIZE THAT 90 TO 100 PERCENT WILL PASS o.5 O.D. OF SUPPORTED N A NO. 4 SIEVE AND NO MORE THAN 5 PERCENT 2. TRENCH SHORING &TRENCH WALL SLOPING SHALL BE IN CONFORMANCE WITH STATE OF CALIFORNIA PIPE WILL PASS A NO. 200 SIEVE. DEPARTMENT OF INDUSTRIAL SAFETY REQUIREMENTS AND THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS. #4 BAR 3. MATERIALS, EMBEDMENT, PLACEMENT AND COMPACTION OF GRANULAR EMBEDMENT* AND COMPACTED (IF BEAM IS PRECAST) BACKFILL WILL CONFORM TO THE AGENCY'S STANDARD SPECIFICATION FOR PIPE BEDDING AND • TRENCH BACKFILL. REINFORCEMENT BEDDING DETAIL NOTES (SEE TABLE) 2" CL. SECTION C - C CASE 2 - BEDDING DETAILS REINFORCED CONCRETE BEAM FOR 4" TO 24" I.D. PIPE - NO SCALE NO SCALE E OD. + W kft 4' 1EI 1EI 1=1 11=1 11EI 11=1 11=1 11=1 11EI 1=1 11=1 I I III III- I I 1=1 11=1 11=1 I I / W JOINT (I F NEEDED TO EXTEND PIPE) iii iii Ti -iii -i ILLL % i / 111111111 DUCTILE IRON 0 _ _ EXIST. CONCRETE, 1=1 MI IMUM 90% (95%)* 1-1 CONTINUOUS W R.C., DUCTILE IRON, 4 MIS -III, RELATIVE IIS PIPE 0- CONCRETE III- 3' OR CLAY PIPE \`\ `\ ` \ \ \ -1 COMPACTION IEI COLLAR =III III- IEI �k (SEE NOTE 2 ) IEI �I I I II -III III= SECTION E - E ` 1111 I-1 CONCRETE 4" FOR CLAY PIPE SEWERS, BEDDING CUT EXIST. PIPE AND JOIN COMPACTED BACKFILL II T II II I II 4A B-1 S B 4A WITH TYPE 'D' JOINTS WITH PLACED AND COMPACTED I-1 I IADAPTAER Rini, �REQQ REQUIRED, ALLOWABLE SPANS AND MIN. REQUIRED BEARING FOR DUCTILE IRON PIPE IN ACCORDANCE WITH -'' I DISTRICT'S STANDARD SPECIFICATIONS FOR PIPE �IIII BEDDING AND TRENCH -III BACKFILL VIII S III= IIII� III- VIII 0” TO T 8'-0" BARS B 8'-1" T TO 12'-0" BARS B PIPE 12'-1" T COVER TO 16'-0" BARS B 16'-1" T TO 20' -O"20' BARS B -l" T TO 25'-0" BARS B 0" TO 4'-0" 8" #4 1'-6" 8" #4 1'-6" 9" #4 V-6" 10" #4 1'-6" 101/2» #4 1'-6" 49-11' TO 5'-0" 8" #4 1'-6" 91/2" #4 V-6" 11" #4 V-6" 12" #4 1'-6" 121/2" #5 1'-6" 5'-1" TO 6'-0" 9" #4 1'-6" 11 #5 1'-6" 121/2" #5 11-6"1131/21' #5 2'-0" 141/27 5 2'-0" 6'-1" TO 7'-0" 10" #5 1'-6" 121/2" #5 2'-0" 1417 #5 2'-0" 151/2" #5 2'-0" 161/2" 6 2'-0" 7'-1 » TO 8'-0" 11" #5 1'-6" 14" #5 2'-0" 16" #5 2'-0" 171/2„ #6 2'-6" 19" #6 2'-6" 89-1" TO 9'-0" 121/2" 5 2'-0" 151/2" #6 2'-6" 171/2" #6 2'- 6 191/2 Is #6 2-6"' 21 #6 2'-6" 9'-1" TO 10'-0" 131/2" 6 2'-0" 17" #6 2'-6" 191 2" #6 3•_0» 21 2" #6 3'-0" 23" 6 3'-0" 10'-1" TO 11'-0" 141/2" #6 2'-6" 181/2" #6 3'-0" 21" #6 3'-0" 231/2" #6 3'-0" 25" 7 3'-0" 11,_ 1 " TO 12'-0" 151/2" #6 2'-6" 20" #6 3'-0" 23» #7 3'-6" 251/2" #7 3'-6" 27» #7 3'-6" 12,_1" TO 13'-0" 17" 6 3'-0" 211/2" #7 3'-6" 241/2» #7 3'-6» 27 2" #7 4'-0" 29" #7 4'-0" 13'- 1 TO 14'-0" 18 #7 3'-0" 23 #7 3 -6 261/2" #7 4 -0 291/2 29 #7 4 -0 311/2" #7 ff 4 -0 14'_ 1 " TO 15'-0" 19" 7 3'-0" 25" #7 4'-0" 28» #7 4'-0" 311/2" #7 4'-6" 15'-1" TO 16'-0" 201/2" 7 3'-6" 261/2" #7 4'-0" 30" #8 4'-6" 16'_ 1 " TO 17'-0" 211/2„ 7 3'-6" 28" #8 4'-6" 17'_ 1 " TO 18'-0" 221/2" #8 4'-0" 291/2„ #8 4'-6" BEDDING DETAIL NOTES (SEE TABLE) 2" CL. SECTION C - C CASE 2 - BEDDING DETAILS REINFORCED CONCRETE BEAM FOR 4" TO 24" I.D. PIPE - NO SCALE NO SCALE E OD. + W kft 4' 1EI 1EI 1=1 11=1 11EI 11=1 11=1 11=1 11EI 1=1 11=1 I I III III- I I 1=1 11=1 11=1 I I / W JOINT (I F NEEDED TO EXTEND PIPE) iii iii Ti -iii -i ILLL % i / 111111111 DUCTILE IRON 0 _ _ EXIST. CONCRETE, 1=1 MI IMUM 90% (95%)* 1-1 CONTINUOUS W R.C., DUCTILE IRON, 4 MIS -III, RELATIVE IIS PIPE 0- CONCRETE III- 3' OR CLAY PIPE \`\ `\ ` \ \ \ -1 COMPACTION IEI COLLAR =III III- IEI �k (SEE NOTE 2 ) IEI �I I I II -III III= SECTION E - E ` 1111 I-1 CONCRETE 4" FOR CLAY PIPE SEWERS, BEDDING CUT EXIST. PIPE AND JOIN COMPACTED BACKFILL II T II II I II 4A B-1 S B 4A WITH TYPE 'D' JOINTS WITH PLACED AND COMPACTED I-1 I IADAPTAER Rini, �REQQ REQUIRED, ALLOWABLE SPANS AND MIN. REQUIRED BEARING FOR DUCTILE IRON PIPE IN ACCORDANCE WITH -'' I DISTRICT'S STANDARD SPECIFICATIONS FOR PIPE �IIII BEDDING AND TRENCH -III BACKFILL VIII M I N I M U M 90% RELATIVE COMPACTION III= IIII� III- VIII OR REMOVE_TOvNEAREST� JOINT BEYOND t'` A CC' Z DEP'iH OF 6' Pim w PIPE 10' PIPE COVER S (MAX.) B( MIN.) S (MAX.) B( MIN.) S (MAX.) B( MIN. ) 0" TO 8'-0" 11'-0" V-6" 13'-6" 1'-6" 16'-6" 2' 0" f 7f , » , » f ff f/ f » f f1 8 -1 TO 16 -0 8 -0 1 -6 10 -0 2 -0 12 -0 2 -6 16'-1" TO 25'-0" 7'-0' 1'-6" 9'-0" 2'-0" 10'-6" 2'-6" ,dI11 1111 \ \ DUCTILE IRON PIPE �I I II IIT NO SCALE Iq -III' �.•-. , =III-1i1=1i1=1i1=1i1=1ilElil=III=III=III=11�I11= PIPE SUPPORTS — GENERAL NOTES NOTES: 1. ALL CROSSING HOUSE LATERALS 10" AND SMALLER SHALL BE SUPPORTED BY 5. CROSSING METALLIC CONDUITS 3 INCHES (NOMINAL SIZE) AND LARGER SHALL BE BACKFILLEDTO 2'-0" BELOW THE 1. MATERIAL FOR COMPACTED BACKFILL WILL CONSIST OF SUITABLE JOB EXCAVATED MATERIALS, IMPORTED SOILS, USE OF CASE 3 PIPE SUPPORT DETAIL. CROSSING CONDUIT WITH MATERIALS AS DESCRIBED IN THE DISTRICT'S DTANDARD SPECIFICATIONS FOR PIPE BEDDING AND TRENCH BACKFILL. THE TRENCH SHALL THEN BE BACKFILLED TO 12 INCHES OVER THE CONDUIT WITH CLEAN, OR GRADED GRAVEL AS DEFINED IN THE AGENCY'S STANDARD SPECIFICATION FOR PIPE BEDDING AND TRENCH 2. ALL NON-METALLIC CROSSING PIPELINE AND CONDUITS WITH 18" OR LESS CLEARANCE, MOISTENED SAND (SAND EQUIVALENT OVER 30), BROUGHT UP IN LAYERS OF NOT OVER 6 INCHES AND MECHANICALLY BACKFILL. SLAG, PEA GRAVEL, CRUSHED ROCK, OR OTHER ALTERNATIVE MATERIALS WILL NOT BE ACCEPTABLE. EXCEPT THOSE COVERED BY NOTE 1 ABOVE, SHALL BE SUPPORTED BY CASE 1 PIPE COMPACTED TO A RELATIVE DENSITY OF AT LEAST 90% WITH SPECIAL ATTENTION BEING GIVEN TO THE PIPE BOTTOM 2. COMPACTION UNDER THE STREET AND STRUCTURES SHALL BE 95%. SUPPORT DETAIL. AND HAUNCH AREAS OF THE BACKFILL. 3. ALL PIPELINES CARRYING RECLAIMED WATER SHALL BE CLEARLY MARKED BY PIPE COLOR (PURPLE) OR BY PLACING 3. ALL NON-METALLIC CROSSING PIPELINE AND CONDUITS NOT COVERED BY THE ABOVE 6. IF BEDDING IS REMOVED FROM THE EXISTING PIPE THAT WILL REMAIN IN PLACE, THE PIPE SHALL BE EMBEDDED IN BACKFILL PURPLE IDENTIFICATION TAPE. SAID TAPE SHALL BE NOT LESS THAN ONE FOOT OR MORE THAN TWO NOTES 1 OR 2 SHALL BE SUPPORTED BY THE USE OF CASE 2 PIPE SUPPORT DETAIL. WITH CONCRETE AT NO EXTRA COST TO THE AGENCY. FEET ABOVE TOP OF PIPE. 4. BACKFILL SHALL BE BROUGHT UP UNIFORMLY ALONG BOTH SIDES OF PROTECTED PIPE AND 7. UNLESS OTHERWISE INDICATED, CONCRETE SHALL BE CLASS 420-C-2000. SUPPORT SO AS TO INDUCE NO UNBALANCED FORCE. BACKFILL DETAIL. PIPE SUPPORT DETAILS NO SCALE BENCHMARK: PER C.S.F.B. 4015/1230 APPROVED BY: COUNTY OF SAN BERNARDINO ELEVATION = 1004.88 0/0, N`! 5,15 0 APPROVED: CHISELED "❑" ON TOP OF CURB 66' M. TAGHI MONZAVI DATE: WEST OF CHERRY AVE., 36' NORTH OF CIVIL ENGINEER FOR SLOVER AVE. (BCR). INLAND EMPIRE UTILITIES AGENCY CHIEF, DESIGN DIVISION RCE No. C49444, Exp. 09/30/06 Undffffound Service AW L.D. KING INC. CONSTRUCTION OF THE CITY OF FONTANA, CALIFORNIA - SHOULD SECTION 4216/4217 OF THE GOVERNMENT/ 2151 CONVENTION CENTER WAY REQUIRED IMPROVEMENTS NOT �,FRF�I SUITE 100 COMMENCE WITHIN TWO YEARS OF THE CHERRY AVENUE o� Y CODE REQUIRES A DIG ALERT IDENTIFICATION ��'� F ONTARIO, CA 91764 INLAND EMPIRE UTILITIES AGENCY DRAWN BY: SCALE: o. o NUMBER BE ISSUED BEFORE A PERMIT TO c� y (909) 937-0200 DATE OF APPROVAL SHOWN HEREON CHERRY AVENUE SEWER IMPROVEMENTS No. 16434 AND CARRIED FORTH IN A DILIGENT pS AS SHOWN EXCAVATE WILL BE VALID `� � ,�DESIGNED BY: PAA 0 SLOVER AVE. DATE: FOR YOUR DIG ALERT I.D. NUMBER CALL * Exp. 6/30/05 * STANDARD BEDDING DETAILS -MANNER, THE CITY ENGINEER MAY UNDERGROUND SERVICE ALERT S c1\1 ,Z�.b REQUIRE REVISIONS TO THE PLANS TO pS ED I TAILS OCTOBER 2005 TFp ��� 5 BRING THEM INTO CONFORMANCE WITH CHECKED BY APP ED Y. DTE: DRAWING NO.: 19 R.C.E. No. 16434 DATE CONDITIONS AND STANDARDS IN EFFECT. � �� ' � TOLL FREE 1-800-227-2600 FCA CARL J. FREEMAN, $CN 2ING TWO WORKING -DAYS BEFORE YOU DIG REV. REVISION DESCRIPTION DATE ENGR. CITY DATE EXPIRES 6-30-05 CI ENGINEER R.C.E. No. 51152 894 19 JN 12414 City of Fontana Mylar: 10/17/03 File: - E:\dwg\12414\Cherry\12407AS119.dwg 11/14/00