HomeMy WebLinkAbout4841-1A CONDUCTOR TABLE
AWG.
CIRCUIT OR
POLE
RUNS
6
FURNISH
tAl
2#10 (LUMINAIRES).
FE.
INSTALL
XAVCU2
CITY FURNISHED
CONTROL UNIT.
1
2
MAY NOT STOP" WILL BE
4
TYPE
m
POLE
POLE
PED.
TYPE
A
B
a
v
POLE 0
_�
1/
1k
1k
N
POLE Q
-
-
S1-1
SEE PLAN
3
TOTAL
1/1
2/1
2/1
2/2
1 /1
$
0 1 LUMINAIRE 1 2 1 2 1 2 1 2 =
** PAVEMENT FLASHER - 1 Ill 11-1
CONDUIT SIZE 3' 1 3' 3' 1 3' 3'
O ALL CONDUIT AND CONDUCTORS ARE NEW
8 CONDUCTOR CABLE, CITY SUPPLIED
FOR THE POLARA PUSH BUTTON CIRCUIT
xW CONTROL CABLE FOR THE IN -GROUND
PAVEMENT FLASHERS
PEDESTRIAN FLASHER CONSTRUCTION NOTES:
NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS.
Ifl
a
a
a
FURNISH AND INSTALL CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE
"P" CABINET, FLASHER CONTROLLER ASSEMBLY, AND APPURTENANT EQUIPMENT.
CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CALTRANS STANDARD
DETAIL ES -3A. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC
EQUIPMENT REQUIRED TO PROVIDE THE FLASHER OPERATION AS SHOWN ON THE PLAN.
INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND
SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS.
INSTALL SIGN AND HARDWARE PER CALTRANS STANDARD PLAN ES -7N, DETAIL "U".
INSTALL 3" SCHEDULE 40 PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE
REQUIREMENTS. COORDINATE SERVICE WITH SCE PLANNING DEPARTMENT AT 909-357-6116.
SEE GENERAL NOTE #4.
EOHL-
L -n. 1\/ rr
F5]
FURNISH
& INSTALL 2"C,
2#6, 1#8 G.F.C.I. (FLASHER SERVICE).
6
FURNISH
& INSTALL 2"C,
2#10 (LUMINAIRES).
❑7
INSTALL
XAVCU2
CITY FURNISHED
CONTROL UNIT.
PEDESTRIAN PUSHBUTTON STATION, POLARA MODEL XAV2 & MODEL
STANDARD AUDIBLE MESSAGE "CROSS STREET WITH CAUTION, VEHICLES
SIG.
MAY NOT STOP" WILL BE
USED.
FURNISH &INSTALL INGROUND PAVEMENT FLASHER CIRCUIT PER CIN SPECIAL PROVISIONS.
F8] CONTRACTOR SHALL FURNISH &INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED TO PROVIDE
FOR THE FLASHER OPERATION AS SHOWN ON THE PLAN.
CONSTRUCT 4" THICK 8' X 12' CONCRETE PAD AROUND CONTROLLER AND SERVICE PEDESTAL.
1-91 REMOVE EXISTING LANDSCAPING & MODIFY IRRIGATION SYSTEM AS APPROPRIATE.
SPRINKLERS SHALL NOT SPRAY ONTO CONTROLLER CABINET OR SERVICE PEDESTAL.
CL
RANDALL
M
PEPPER
ELEMENTARY SCHOOL
■ P O L_ E S C H E D U L_ E
LSTANDARD
C
MAST ARMS
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
WARNING SIGN
PLACEMENT
REMARKS
TYPE
HT.
SIG.
LUM.
H.P.S.V.
TYPE
PHASE QUAD
VEHICLE
POLE
PED.
TYPE
A
B
A
'SPL' TYPE 9A
30'
18'
15'
250 W
- W
I
2 -MAT
-
-
S1-1
SEE PLAN
3
B
PPB POLE
3 10
-
-
-
$
- W
-
-
-
-
4'
3
C
TYPE 9A
20
18'
1 -
-
1 -
-I -
2 -MAT
i -
I -
S1-1
3'
-5'
® ALL NEW EQUIPMENT
Curb/Berm flow line
or edge of shoulder
EX. R/W
* POLARA MODEL XAV2-LED, AUDIBLE PEDESTRIAN PUSHBUTTON
I (1(`%ATI()NI
T
T -
NOTE: POTHOLING REQUIRED FOR ALL POLES
TRAFFIC SIGNAL GENERAL NOTES.-
1.
OTES:1. TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO
THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD
DETAILS, AND THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION
86 (DATED MAY 2006) AND STANDARD PLANS (DATED MAY 2006), THE CALIFORNIA
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS,
DATED SEPTEMBER 2006.
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATINS UNTIL CLEAR OF ANY OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING
DAYS BEFORE DIGGING.
3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS
OTHERWISE SHOWN.
4. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING
WITH SOUTHERN CALIFORNIA EDISON COMPANY SIX WEEKS IN ADVANCE OF NEED.
5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET.
6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK.
7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE
ENGINEER.
8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKERS SYSTEMS IF NECESSARY.
g. NOT USED.
10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL
PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES & UTILIZE PEDESTRAIN
COUNTDOWN TIMERS PER SPECIAL PROVISIONS.
11. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL
REPLACED WITH NEW CONSTRUCTION.
12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO
CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT
AS NOTED CITY FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL
PROVISIONS.
13. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT
OR POTENTIAL CONFLICT WITH THESE PLANS AND,OR SPECIFICATIONS FOR THIS
PROJECT.
14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE
BORING METHOD, TRENCH REPAIRS SHALL BE PER CITY STANDARD, AND SPECIAL
PROVISIONS, SECTION E.
15. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE
SHOWN ON THE PLANS.
51-1
3699X3691
SCALE: 1;20
1 • • 1 '1 •1