Loading...
HomeMy WebLinkAbout3552-9REDUCE PRESSURE BACKFLOW PREVENTION PRESSURE REGULATOR IF REQUIRED. SET AS SHOWN ON SITE DRAWING STRAINER #40 MESH MONEL BACKFLOW ENCLOSURE (SEE NOTE BELOW) BRASS ELBOW -- BRASS NIPPLE BRASS BALL VALVE - BRASS PIPE LOCKBOX -, zo .� STAINLESS STEEL "U" BOLT EMBEDDED IN CONCRETE FOR 00 LOCKING FEATURE BRASS ELBOW CONC, STABILIZER PRESSURE SUPPLY LINE (INTAKE) BRASS NIPPLE (4 PLACES) BRASS ELBOW BRASS NIPPLE BRASS UNION BRASS BALL VALVE BRASS PIPE HINGE (2 PLACES) ,- #4 REBAR CONTINUOUS LOOP PRESSURE SUPPLY LINE (DISCHARGE) �-- MALE ADAPTOR PVC SCH, 40 BLASS ELBOW (DO NOT ENCASE 3/4" GRAVEL IN CONC, STABILIZER NOTE: BACKFLOW ENCLOSURE: LEMEUR GREEN CAGE MODEL # BF -99 OR EQUAL I8WX30LX30H: HIGH & HINGED AT ONE END. SECURE TO CONCRETE PAD -SIZE AS REQUIRED W/ 4" 'J' BOLTS.EQUIPMENT TO BE CENTERED INSIDE HOUSING). WIRE BACKFLOW ENCLOSURE. NOTE: CONTRACTOR SHALL FORM ENCLOSURE BASE AND REQUEST INSPECTION PRIOR TO POURING. CONTRACTOR SHALL USE 520-C-2500 CONCRETE. i SCALE: N.T.S. 61, POP-UP SP SCALE: N.T.S. E'"[11i 11 LEGEND: 1, POP-UP SPRAY HEAD, 3/4" ABOVE FINISH GRADE IN LAWN AREAS AND 1 1/2" ABOVE FINISH GRADE IN PLANTING AREAS. 2. WALK OR CURB. 3. PVC SCH. 80 NIPPLE - 4" MIN. LENGTH, 4. PVC TXT 90 DEG. ELL. 5, LATERAL LINE PIPE AND FITTING. 6, MARLEX 90 DEG. STREET ELL. 7. PVC SCH. 80. NIPPLE - 6" LONG. 8. FINISH GRADE. * 1 1/2" IN TURF AREAS, 3" IN PLANTING BEDS. NOTE: USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC TO PVC OR METAL TO PVC MALE PIPE THREADS. LEGEND: 1. 6" ROUND PLASTIC FULL BOX COVER BOLT DOWN TYPE. 2. FINISH GRADE LAWN AREAS. 3. FINISH GRADE SHRUB AREAS. 4. COMMUNICATION CABLE/CONTROL WIRE. 5. PEA GRAVEL. (MIN. 2" CU. FT.) NOTE: REMOTE CONTROL BOX MAY BE USED IN LIEU OF SPLICE BOX. SPLICE BOX ASSEMBLY SCALE: N.T.S. PROJECT: SYCAMORE HILLS-TR.16495-2 BY: JDD NECESSARY, AND 3" ABOVE FINISH GRADE STATIC PRESSURE HIGH: 108 LOW: 97 SLEEVING NOTES: SOURCE OF INFORMATION: PEGGY HARDSCAPING (SEE NOTE #4) FINISH GRADE SUPPLIER: WEST SAN BERNARDINO COUNTY WATER DISTRICT TRENCHING NOTES: PHONE NUMBER: (909) 875-1804 S REQUIRE IN 2" HIGH CHARACTERS. VALVE STATION/GPM: STATION: H-1 GPM: 45 6" N. ITEM: P.S.I. LOSS: WATER METER SIZE: 2"@ 45 GPM 1.60 PRESSURE REGULATOR: 2" @ 45 GPM 4.00 BACKFLOW DEVICE: 2" @ 45 GPM 12,00 FLOW SENSOR: 11/4" @ 45 GPM 3.30 MASTER VALVE: 2" @ 45 GPM .68 GATE VALVE(S): 2 3" @ 45 GPM 2.00 MAINLINE (CL. 315): 3" 729 L.F. @ 45 GPM 5.18 AUTOMATIC VALVE SIZE: 2 2" @ 45 GPM .68 LATERAL LINE SIZE: 3/4" 88 L.F. @ 8 GPM .47 1 " 55 L.F. @ 15 GPM .55 11/4" 20 L.F. @ 24 GPM .42 11/2" 10 L.F. @ 32 GPM ,38 2" 10 L.F. @ 45 GPM .14 IRRIGATION HEAD PRESSURE: CONTROL WIRES 30.00 SYSTEM LOSSES SUBTOTAL: SLEEVE FOR POTABLE LINE MINIMUM 61.40 FITTING LOSSES (10% OF SUBTOTAL): 6.18 6.14 (ESTIMATED) ELEVATION LOSSES/GAINS (ELEV. X,433) 6.80 TOTAL SYSTEM LOSSES: WATER LINE. 74.34 AVAILABLE PRESSURE (LOW): .47 97.00 {-) DEFICIT OR (+) RESIDUAL PRESSURE: (+)22.66 MO *CONTRACTOR TO SET PRESSURE REGULATOR TO A SYSTEM DESIGN ffmo sm- PRESSURE OF 75 PSI CONTRACTOR TO FIELD ADJUST REGULATOR AS I��ir •Mrs= NECESSARY. E e • ii•�i PRESSURE LOSS CALCULATION"K - • WHITE BLUE IRRIGATION CONTROLLER RED BLACK PLASTIC VALVE BOX CARSON OR EQUAL) WITH PLASTI INTEGRATED - LOCKING LID. PLACE AT GRADE IN TURF AREAS AND 3" ABOVE IN PLANT BED. RED YELLOW PIGTAIL EXPANSION bg bg LOOP (MIN. 24" LONG) V PVC CONDIT TO V PEDESTAL CONTROLLER' 1 DIAMETER SAME SI7E AS BLUE WHITE wl STII (COMMON) DIAMFTEA SAME SNAP-TITE WATERPROOF CONNECTOR OR EQUAL PIGTAIL EXPANSION LOOP (MIN. 24" LONG) MASTER CONTROL VALVE MINIMUM DISTANCE DOWNSTREAM OF I. UNINTERRUPTED PIPE (5X DIAMETER OF FLOW METER SIZE) MINIMUM DISTANCE UPSTREAM OF UNINTERRUPTED PIPE (10X DIAMEETER OF FLOW METER SIZE) NOTE: WATERPROOF ALL WIRE CONNECTIONS, FLOW METER/MASTER VALVE SCALE: N.T.S.3211 24" L T 5 ,e • _ .. • • 14 15 9 ce) 10 16 13 11FOOTI NG 12 LEGEND% 1. RADIO ANTENNA - LOCATION PER CITY OR MANUFACTURER'S RECOMMENDATIONS. 2. 24" FRONT ENTRY SATELLITE ASSEMBLY w/ NEMA 3R STAINLESS STEEL RAINPROOF ENCLOSURE (UL LISTED), STRONGBOX MODEL # 813-240120V. 3. MASTER VALVE RELAY OR PUMP START RELAY, 4. RADIO REMOTE ACCESS, 5. 11/2" PVC CONDUIT FOR 120 UAC FROM METERED POWER SUPPLY OR PER LOCAL ELECTRICAL CODES. 6. POWER SWITCH/GFI RECEPTACLE. 7. SATELLITE CONTROLLER. 8. 11/4" PVC CONDUIT FOR COMMUNICATION CABLE. 9. PVC CONDUIT FOR CONTROL WIRES, SIZE AS REQUIRED. 10.1" PVC CONDUIT FOR FLOW SENSOR CABLE. 11.1 1/4" PVC CONDUIT FOR COMMUNICATION CABLE TO OTHER SATELLITES (IF APPLICABLE). 12.5/8" DIA. X 8' GROUND ROD W/#10 GROUND WIRE & CLAMP. r-HUiv i vit=vv 13, POURED CONCRETE FOOTING. 14, FILL VOIDS WITH CONCRETE. - NOTE: SEE MATERIALS LIST LOCATED NEXT 15.1" PVC CONDUIT FOR #10 GROUND WIRE. TO CONTROLLER ON SHEET L-7. 16.1 1/4" PVC CONDUIT FOR FUTURE USE. -NETWORK 8000 CONTROLLER, RADIO, RADIO LINK, POWER SUPPLY, & SENSOR INPUT BOARD INSTALLED ON BACKBOARD. -CONTRACTOR TO THROW AWAY PEDESTAL TEMPLATE AFTER USE, DO' NOT LEAVE UNDER CABINET. IRRIGATION CONTROLLED FRONT VI EI pv SCALE: N.T.S, NECESSARY, AND 3" ABOVE FINISH GRADE CLEAN BACKFILL - SEE SPECS TRENCHING: SLEEVING NOTES: FOR MATERIAL 90% COMPACTION HARDSCAPING (SEE NOTE #4) FINISH GRADE REQUIRED TRENCHING NOTES: 1. ALL SLEEVES TO BE SCH. 40 PVC. S REQUIRE IN 2" HIGH CHARACTERS. 1. BELOW PAVED AREAS A MINIMUM 2. EXTEND ALL SLEEVES 12" BEYOND 6" N. z OF 6" LAYER OF CLEAN EARTH EDGE OF HARDSCAPING AT BOTH ENDS, PROVIDE 6" MIN. OF SAND 6f 1 01)C\1 SHALL BEINSTALLED ABOVE AND 3. ROUTE SLEEVING AROUND HANDICAP BEDDING AND SHADDING z BELOW PIPING. N { oW z 2. PROVIDE MINIMUM COVER OF 24" NON -PRESSURE 00 '- ON PRESSURE SUPPLY LINES 3" AND LARGER. LATERAL LINE` TO TRAFFIC LOADS. REFER TO CITY DIAMETER OF NON- STD. (24" MIN, TO 30" MAX. DEPTH TO PRESSURE LATERAL LINE CONTROLLER. 3. WHEN USING RECLAIMED WATER, CLEAN BACKFILL - CONTROL WIRE SLEEVE - SIZE PER PLAN, INSTALL PRESSURE SUPPLY LINE MAINTAIN MINIMUM 10' HORIZONTAL 90% COMPACTION • 11. PVC SCHEDULE 40 PIPE (TYP,) SEPARATION BETWEENPOTABLE 12. PVC SXS 90 DEG, ELL SLEEVING/TRENCHING SCALE: N.T.S, AND RECLAIMED PRESSURE LINES, 14. MAINLINE FITTING W/SOLVENT-WELD OUTLET, 44 GPM MIN. 2" OF CLEAN EARTH WHERE LINES CROSS, PROVIDE PVC CONTROL WIRES 16. CHRISTY'S I.D. TAG WNALVE STATION N0. & INSTALL IN SHRUB PLANTING AREAS, SLEEVE FOR POTABLE LINE MINIMUM MAINLINE (CL. 315): 3 799 L.F. @ 17. UNION 6.18 V EACH SIDE OF RECLAIMED AUTOMATIC VALVE SIZE: 2 2" @ im�"rfmm e e WATER LINE. LATERAL LINE SIZE: 3/4" 82 L.F. @ 8 GPM .47 4. BUNDLE WIRES WITH TAPE EVERY 10'. SLEEVING: LEGEND: NECESSARY, AND 3" ABOVE FINISH GRADE CLEAN BACKFILL - SEE SPECS IN PLANTING AREAS. SLEEVING NOTES: FOR MATERIAL 90% COMPACTION HARDSCAPING (SEE NOTE #4) 15 16 13 1 2 4 REQUIRED DESIGNED BY: 1. ALL SLEEVES TO BE SCH. 40 PVC. ' IN 2" HIGH CHARACTERS. tu 2. EXTEND ALL SLEEVES 12" BEYOND SOURCE OF INFORMATION: PEGGY z D• EDGE OF HARDSCAPING AT BOTH ENDS, PROVIDE 6" MIN. OF SAND 6f 1 01)C\1 3352 3. ROUTE SLEEVING AROUND HANDICAP BEDDING AND SHADDING r;P 12 11 5 RAMPS. 6. PVC PIPE TO SPRINKLERS - ANGLE PIPE oW z NON -PRESSURE LATERALS 4. PIPING UNDER PAVEMENT SUSCEPTIBLE LINE SLEEVE - SIZE TWICE 7. COMMON BRICK (4 REQUIRED). TO TRAFFIC LOADS. REFER TO CITY DIAMETER OF NON- STD. (24" MIN, TO 30" MAX. DEPTH TO PRESSURE LATERAL LINE CONTROLLER. TOP OF PIPE BELOW STRUCTURAL PRESSURE SUPPLY LINE SLEEVE - CONTROL WIRE SLEEVE - SIZE PER PLAN, INSTALL SECTION). SIZE TWICE DIAMETER OF PRESSURE SUPPLY LINE ,ADJACENT TO PRESSURE • 11. PVC SCHEDULE 40 PIPE (TYP,) SUPPLY LINE. 12. PVC SXS 90 DEG, ELL SLEEVING/TRENCHING SCALE: N.T.S, 14. MAINLINE FITTING W/SOLVENT-WELD OUTLET, r SCALE: N/A SCALE: LEGEND: 1. ROUND PLASTIC VALVE BOX & COVER MARKED "IRRIGATION GATE" USE CHRISTY FL8 BOX & FL80 LID OR EQUAL. 2. FINISH GRADE. 3. GATE VALVE - SEE IRRIGATION LEGEND FOR MODEL#, 4. 3/4" WASHED CRUSHED AGGREGATE BASE, 1 CUBIC FOOT. 5. SCH. 40 PVC MALE ADAPTORS. NOTE: PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX. GATE VALVE SCALE: N.T.S. 28" 1 2 LEGEND: 1. RADIO ANTENNA - LOCATION PER CITY OR MANUFACTURER'S RECOMMENDATIONS. 2. 24" FRONT ENTRY SATELLITE ASSEMBLY w/ NEMA 3R STAINLESS STEEL RAINPROOF ENCLOSURE (UL LISTED), STRONGBOX MODEL # SB-24SS/120V. 3. CONTROLLER/SATELLITE PER FRONT VIEW CONTROLLER DETAIL. 4. METER SOCKET WtTEST BLOCKS. 5. CLUSTER CONTROL UNIT OR SECOND CONTROLLER/SATELLITE IF APPLICABLE. 6. LOAD CENTER 7. POURED CONCRETE BASE. B. #10 GROUND WIRE AND SLEEVE TO GROUND ROD CLAMP. 9. CONDUIT(S) PER FRONT VIEW CONTROLLER DETAIL, 10.5/8" DIA, X 10' DRIVEN GROUND ROD PER ARTICLE 250-81 OF 1990 NEC, 11. METER WINDOW WITH METER BEHIND TO FACE STREET. NOTE: SEE MATERIALS UST LOCATED NEXT TO CONTROLLER ON SHEET L-7. IRRIGATION CONTROLLER SIDE VIEW SCALE: N.T.S. NOTE: BLOCKS SHOULD BE FOR MAINLINE 21/2" AND LARGER. DO NOT USE SUP AND BELL PVC PIPING. THRUST BLOCKS SHAD- INCLUDE #3 REBAR AROUND PIPE AND INTO THRUST BLOCK. SCALE: N.T.S. SCALE: 3/4" ABOVE FINISH GRADE IN LAWN, WHEN LEGEND: NECESSARY, AND 3" ABOVE FINISH GRADE SYCAMORE H L.S IN PLANTING AREAS. 1. ELECTRIC CONTROL VALVE. TRACT. # 1 2, RECTANGULAR VALVE BOX W/GREEN 15 16 13 1 2 4 BOLT -DOWN COVER. HEAT BRAND VALVE DESIGNED BY: STATION. NO. & CONTROLLER LETTER ON LID STATIC PRESSURE HIGH: 1Q8 IN 2" HIGH CHARACTERS. tu If/� SOURCE OF INFORMATION: PEGGY 3. 2" CLEAR SPACE, D• 00 UPw II = 4. FINISH GRADE. 3352 SCALE: N.T.S. SCALE: 3/4" ABOVE FINISH GRADE IN LAWN, WHEN LEGEND: NECESSARY, AND 3" ABOVE FINISH GRADE SYCAMORE H L.S IN PLANTING AREAS. 1. ELECTRIC CONTROL VALVE. TRACT. # 1 2, RECTANGULAR VALVE BOX W/GREEN 15 16 13 1 2 4 BOLT -DOWN COVER. HEAT BRAND VALVE DESIGNED BY: STATION. NO. & CONTROLLER LETTER ON LID STATIC PRESSURE HIGH: 1Q8 IN 2" HIGH CHARACTERS. tu ®_j0 SOURCE OF INFORMATION: PEGGY 3. 2" CLEAR SPACE, D• 00 UPw II = 4. FINISH GRADE. 3352 = -CC) 0., F M �,GI-ry ENGINEER R.C.E. 51152 EXP. DATE 12/31/05 5. PVC MALE ADAPTER (TYP.) 12 11 5 6 6. PVC PIPE TO SPRINKLERS - ANGLE PIPE oW z TO SPECIFIED DEPTH WITH 45 DEG. ELLS. I��� a r�•..�•. 7. COMMON BRICK (4 REQUIRED). . o c e . 0 17 8. COMMON WIRE TO OTHER VALVES ON SAME •-: • o • c •t CONTROLLER. PRESSURE REGULATOR: 2" @ + 3 7 9. 3/4" CRUSHED ROCK, 8" DEEP. 10. CONTROUCOMMON WIRES FROM CONTROLLER. • 11. PVC SCHEDULE 40 PIPE (TYP,) 14 10 9 8 12. PVC SXS 90 DEG, ELL _MM 13. WIRE CONNECTOR. 14. MAINLINE FITTING W/SOLVENT-WELD OUTLET, 44 GPM 15. COIL WIRES PER SPECIFICATIONS AND WITH 24" LOOP, NOTE: USE TEFLON TAPE ON ALL PVC TO PVC OR METAL TO PVC MALE PIPE THREADS. 16. CHRISTY'S I.D. TAG WNALVE STATION N0. & INSTALL IN SHRUB PLANTING AREAS, CONTROLLER LETTER. MAINLINE (CL. 315): 3 799 L.F. @ 17. UNION REMOTE CONTROL VALVE SCALE: N.T.S. 7 0 m 18" 3'-4' MAX. 11 8 z cr N 9 TIPPING BUCKET SCALE: N.T.S. 570 SERIES PCD SCREEN SELECTION CHART LEGEND: 1. 4" DIA, STEEL POST CAP. SECURE TO PIPE. 2. TIPPING BUCKET BRACKET, S. 1/2" DIA, FLEXIBLE ALL-WEATHER ELECTRICAL CONDUIT, CONNECT BOX TO BOX. 4. TIPPING BUCKET RAIN GUAGE, INSTALL PER MANUFACTURER'S RECOMMENDATIONS, 5. 4" DIA. GALVANIZED STEEL PIPE POST. 6. WEATHER-PROOF ELECTRICAL'J' BOX. DRILL 1" DIA, HOLE THROUGH PIPE & MOUNT BOX TO PIPE. 7. SLOPE TOP OF FOOTING AWAY FROM PIPE. 8. FINISH SURFACE. 9. NATURAL COMPACTED SOIL. 10. 1" DIA, ELECTRICAL, PVC FROM PIPE TO CONTROLLER. 11. PROPOSED CONTROLLER ENCLOSURE. 12. STAINLESS STEEL HOSE CLAMPS, (2)' EACH. NOTE: ACID WASH STEEL PIPE POST, STEEL POST CAP AND ELECTRICAL'J' BOX THOROUGHLY. PAINT WITH (1 COAT RUSTOLEUM PRIMER AND (2) COATS OF FOREST GREEN EXTERIOR HIGH GLOSS PAINT. 10 r M -MA U'VOIN SCALE: N.T.S. SCALE: LEGEND: 1.. HI -POP SHRUB HEAD BODY SET 11/2" MINIMUM ABOVE FINISH GRADE. 2. FINISH GRADE. 3. SCH. 40 PVC 90 DEGREE STREET ELL. 4. MARLEX 90 DEGREE STREET ELL 5. SCH. 80 PVC NIPPLE TYPICAL (2) PLACES. 6. MARLEX 90 DEGREE STREET ELL 7. NON -PRESSURE LATERAL FITTING. 8. NON -PRESSURE LATERAL LINE. NOTES: 1. LOCATE HEAD 2" TO 6" FROM WALKS, CURBS HARDSCAPING, MOW STRIPS, AND EDGES OF LAWN. 2. USE TEFLON TAPE ON ALL MALE THREADS. 3. INSTALL HEADS WITH INTERNAL CHECK VALVE AND PRESSURE COMPENSATING FEATURE AS PER THE IRRIGATION PLAN. 4. HEAD CONNECTION AT BOTTOM INLET ONLY. 12" POP-UP SPRAY HEAD SCALE: N.T.S. LEGEND: 1. 10" PLASTIC VALVE BOX WITH 2" LETTERS "Q.C." AND BOLT LOCK LID. 2. 1/2" STAINLESS STEEL HOSE CLAMP, 3 REQUIRED, 3. QUICK COUPLING VALVE, TOP OF VALVE SHALL BE 2" BELOW VALVE BOX COVER. 4. BRASS NIPPLE, LENGTH AS REQUIRED. 5. PRESSURE SUPPLY LINE. 6. PRESSURE LINE FITTING, 7.. BRASS 90 DEGREE STREET ELL. 8. BRASS NIPPLE, LENGTH AS REQUIRED. 9. #4 REBAR STAKE 36" LONG. 10, BRASS 90 DEGREE STREET ELL. 11. BRASS 90 DEGREE ELL. 12. PEA -GRAVEL, 2 CUBIC FEET MIN. NOTE: PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. QUICK COUPLING VALVE SCALE: N.T.S. LANDSCAPE ARCHITECTURE s TE PLAN N ING 10221-A Trademark Street Rancho Cucamonga, CA 91730 (909) 484-2800 Fax (909) 484-2802 ° n Richard Krumwiede CA L1c. 42834 AZ L1c. # 29115 NV Lic. # 446 TX. Lic. #1884 �pN �} S C A p,� um q��, a y� P. m v w c7 9"104 ' enato 0 i d" Q. �?► Date 9T OQ. OF CN DRAWN BY: JDD SYCAMORE H L.S SCALE: AS SHOWN TRACT. # 1 CO j ULO� 'L DESIGNED BY: U Y FACT (STRICT STATIC PRESSURE HIGH: 1Q8 LOW: 97 tu ®_j0 SOURCE OF INFORMATION: PEGGY u_ d `�- o DWG, NO,: 00 UPw SUPPLIER: (NEST SAN BERNARDINO COUNTY WATER DISTRICT uj , 07 3352 = -CC) 0., F M �,GI-ry ENGINEER R.C.E. 51152 EXP. DATE 12/31/05 wu)o M Nt GPM: 44 oW z T- 00 I��� a r�•..�•. to 0 CY) �••:��-:�•.:� V •-: 44 GPM 1.60 PRESSURE REGULATOR: 2" @ 44 GPM 4.00 I� [e • •. "0210111111131111111111111 MMt _MM •.. MASTER VALVE: 2" @ 44 GPM .68 GATE VALVE(S): 2�� 3" @ 44 GPM 2.00 MAINLINE (CL. 315): 3 799 L.F. @ 44 GPM 6.18 AUTOMATIC VALVE SIZE: 2 2" @ im�"rfmm e e M 0 --mm LATERAL LINE SIZE: 3/4" 82 L.F. @ 8 GPM .47 MENEM Imm�[em m • e MO • % MMIN Le�ili ffmo sm- Il Gi � • I��ir •Mrs= 11/2" 10 L.F. @ E e • ii•�i iii 7ii7 - - i�1 - • .14 IRRIGATION HEAD PRESSURE: 30,00 SYSTEM LOSSES SUBTOTAL: I�ri7%]�31iLei a dii7 • . • � � . i'i� • .. � � . - � • . . a.- ,• a •M•..M•.-iiie•eviii�e• TOTAL SYSTEM LOSSES: 71.58 111=m 1_IM" e • �. rsmwme • r i17i'R". 10TORI IIII04 Mi'MMI (+)25.42 a i7 • r m"s • • MM -Mm . I ? ff M. • . i[e� e• it7 - i m"t • • =I� ■ SCALE: N/A SCAPIF I PPLIG pw l��o • iG� i"F�[•�►i1iTc�[•�► iF�[•1!►i7iCc� • ► :�iTc� • • 1�=I [rs=M-� • e M• • �m • • = i• tm• � mf . I��i� • . • t: - i� • . iF�i'1 i�! i[1��7iCli M- e • i2e1;o •�-• ins I����� • . • r�l[•71�1 ins.h m . • liclF•7i11.71 I��r���.tlt''�i7i�itei7il7i��] - FAC -� �f•�i�k'�77 K43 MK Eitly-MENWIMS KN91111110. N MUM ME AS SHOWN I1=11=11MMIMe a • i Fsni 1IM�MI=IM • . •. M- 11IM 17i1F - KM. F�•1i'I:�5=1 1��������f's�L'RP:�E>J•i�rll�-'1•F��itc� c • 1��<<F3!•. • •L • ••.-am [•i-� • ] a .I 11mrsi ms• . om• ' • ii i i I%�ni ■ •C�iT►i e[�'ir��[eXi7' .• . r M -MA U'VOIN SCALE: N.T.S. SCALE: LEGEND: 1.. HI -POP SHRUB HEAD BODY SET 11/2" MINIMUM ABOVE FINISH GRADE. 2. FINISH GRADE. 3. SCH. 40 PVC 90 DEGREE STREET ELL. 4. MARLEX 90 DEGREE STREET ELL 5. SCH. 80 PVC NIPPLE TYPICAL (2) PLACES. 6. MARLEX 90 DEGREE STREET ELL 7. NON -PRESSURE LATERAL FITTING. 8. NON -PRESSURE LATERAL LINE. NOTES: 1. LOCATE HEAD 2" TO 6" FROM WALKS, CURBS HARDSCAPING, MOW STRIPS, AND EDGES OF LAWN. 2. USE TEFLON TAPE ON ALL MALE THREADS. 3. INSTALL HEADS WITH INTERNAL CHECK VALVE AND PRESSURE COMPENSATING FEATURE AS PER THE IRRIGATION PLAN. 4. HEAD CONNECTION AT BOTTOM INLET ONLY. 12" POP-UP SPRAY HEAD SCALE: N.T.S. LEGEND: 1. 10" PLASTIC VALVE BOX WITH 2" LETTERS "Q.C." AND BOLT LOCK LID. 2. 1/2" STAINLESS STEEL HOSE CLAMP, 3 REQUIRED, 3. QUICK COUPLING VALVE, TOP OF VALVE SHALL BE 2" BELOW VALVE BOX COVER. 4. BRASS NIPPLE, LENGTH AS REQUIRED. 5. PRESSURE SUPPLY LINE. 6. PRESSURE LINE FITTING, 7.. BRASS 90 DEGREE STREET ELL. 8. BRASS NIPPLE, LENGTH AS REQUIRED. 9. #4 REBAR STAKE 36" LONG. 10, BRASS 90 DEGREE STREET ELL. 11. BRASS 90 DEGREE ELL. 12. PEA -GRAVEL, 2 CUBIC FEET MIN. NOTE: PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. QUICK COUPLING VALVE SCALE: N.T.S. LANDSCAPE ARCHITECTURE s TE PLAN N ING 10221-A Trademark Street Rancho Cucamonga, CA 91730 (909) 484-2800 Fax (909) 484-2802 ° n Richard Krumwiede CA L1c. 42834 AZ L1c. # 29115 NV Lic. # 446 TX. Lic. #1884 �pN �} S C A p,� um q��, a y� P. m v w c7 9"104 ' enato 0 i d" Q. �?► Date 9T OQ. OF CN CITY OF FONTANA, CALIFORNIA DRAWN BY: JDD SYCAMORE H L.S SCALE: AS SHOWN TRACT. # 1 CO j ULO� 'L DESIGNED BY: U Y FACT (STRICT STATIC PRESSURE HIGH: 1Q8 LOW: 97 tu ®_j0 SOURCE OF INFORMATION: PEGGY u_ d `�- o DWG, NO,: 00 UPw SUPPLIER: (NEST SAN BERNARDINO COUNTY WATER DISTRICT uj , 07 3352 = -CC) 0., F M �,GI-ry ENGINEER R.C.E. 51152 EXP. DATE 12/31/05 wu)o M Nt GPM: 44 oW z T- 00 -C�o CL M to 0 CY) V WATER METER SIZE: 2" @ CITY OF FONTANA, CALIFORNIA DRAWN BY: JDD SYCAMORE H L.S SCALE: AS SHOWN TRACT. # 1 PROJECT. SYCAMORE HILLS-TR.16495-2 BY: JDD DESIGNED BY: U Y FACT (STRICT STATIC PRESSURE HIGH: 1Q8 LOW: 97 2/5/04 SOURCE OF INFORMATION: PEGGY PPROVED B DWG, NO,: 9 SUPPLIER: (NEST SAN BERNARDINO COUNTY WATER DISTRICT OATE�• L •� 3352 PHONE NUMBER: (909) 875-1804 �,GI-ry ENGINEER R.C.E. 51152 EXP. DATE 12/31/05 VALVE STATION/GPM: STATION: D-24 GPM: 44 ITEM: P.S.I. LOSS: WATER METER SIZE: 2" @ 44 GPM 1.60 PRESSURE REGULATOR: 2" @ 44 GPM 4.00 BACKFLOW DEVICE: 2" @ 44- GPM 12.00 FLOW SENSOR: 11/4" @ 44 GPM 3.30 MASTER VALVE: 2" @ 44 GPM .68 GATE VALVE(S): 2�� 3" @ 44 GPM 2.00 MAINLINE (CL. 315): 3 799 L.F. @ 44 GPM 6.18 AUTOMATIC VALVE SIZE: 2 2" @ 44 GPM .68 LATERAL LINE SIZE: 3/4" 82 L.F. @ 8 GPM .47 1 " 57 L.F. @ 13 GPM .55 11/411 27 L.F. @ 22 GPM .42 11/2" 10 L.F. @ 28 GPM .38 2" 2 L.F. @ 44 GPM .14 IRRIGATION HEAD PRESSURE: 30,00 SYSTEM LOSSES SUBTOTAL: 62.40 FITTING LOSSES (10% OF SUBTOTAL): 6.24 (ESTIMATED) ELEVATION LOSSES/GAINS (ELEV. X.433) 2.94 TOTAL SYSTEM LOSSES: 71.58 AVAILABLE PRESSURE.(LOW): 97.00 (-} DEFICIT` OR (+) RESIDUAL PRESSURE: (+)25.42 *CONTRACTOR TO SET PRESSURE REGULATOR TO A SYSTEM DESIGN PRESSURE OF 75 PSI CONTRACTOR TO FIELD ADJUST REGULATOR AS. NECESSARY. PRESSURE LOSS CALCULATIOND" ■ SCALE: N/A SCAPIF I PPLIG pw PNU Ru 1"i 1 • i2e1;o •�-• ins ins.h ■ - FAC 11� 6/21/04 AS SHOWN CITY OF FONTANA, CALIFORNIA DRAWN BY: JDD SYCAMORE H L.S SCALE: AS SHOWN TRACT. # 1 DESIGNED BY: U Y FACT (STRICT DATE: KPF 2/5/04 CHECKED BY: PPROVED B DWG, NO,: 9 JAF OATE�• L •� 3352 14 �,GI-ry ENGINEER R.C.E. 51152 EXP. DATE 12/31/05 JAB NUMBER .-SHEET NUMBER O I�.