HomeMy WebLinkAbout3552-5PRECAST CAP PRECISION BAND SPLIT -FACE BAND NOTES; - CONTRACTOR TO ALTERNATE COURSES OF SPLIT -FACE AND PRECISION BLOCK. USE 6x8x16 BLOCK. (SPLIT FACE ON SIDE VISIBLE FROM STREET) • ALL SPLIT -FACE MASONRY WALL COLOR WILL BE ANGELUS #200 OR EQUAL. - ALL PRECISION MASONRY WALL COLOR WILL BE ANGELUS #200 OR EQUAL • ALL WALL HEIGHTS SHALL BE MEASURED FROM HIGHEST ADJACENT GRADE. • CONTRACTOR TO USE ANGELUS # 20010x4x16 BEVELED PRECISION MASONRY PRE -CAST WALL CAP OR EQUAL, 3" i BANDED NOTE: CONTRACTOR TO CONTINUE BANDING FROM ADJACENT EXISTING BANDED WALL, EVEN AT COURSE STEP POINTS. _ U-) REFER TO PROTO II DETAILS ATTACHED TCS BACK OF P SPLIT-FACE/PRECISION BANDED MASONRY WALL SCALE: N.T.S. LEGEND; 1, GRANITE BOULDER SIZE PER PLAN, BURY 1/3 OF TOTAL DEPTH BELOW FINISH GRADE AS SHOWN. 2. FINISH GRADE LINE, NOTE: LANDSCAPE ARCHITECT TO APPROVE BOULDERS AND SPOT LOCATIONS PRIOR TO INSTALLATION. BOULDER PLACEMENT SCALE: N.T.S. SCALE: SCALE: 24" sq. PLAN VIEW ND; 24" SQUARE POURED -IN-PLACE CONC. PILASTER CAP TO MATCH WALL CAP. COLOR TO BE TAN. 16 x 8 x 16 CONC, PRECISION PILASTER BLOCK. COLOR WILL BE ANGELUS #200 OR EQUAL. FILL VOIDS SOLID WITH CONCRETE, 2" THICK LAYER OF "SILVER RIVER ROCK" VENEER #1126 AVAILABLE THROUGH RIVERSIDE STONE VENEER, (909) 689-2901. v Y135° 5. # 4 VERT, @ EACH CORNER. EXTEND INTO CAP SECTION 6, FINISH GRADE. 7. CONCRETE FOOTING, 8. # 4 HORIZONTAL CONT, AT 4 LOCATIONS. EXTEND 18" INTO ADJACENT WALL ON EACH SIDE, 24" 9. 90 % COMP. SUBGRADE, CAP DETAIL 10, ADJACENT MASONRY BLOCK WALL CAP. 11. CONTRACTOR TO INSTALL VENEER STONE MASONRY CLIPS PER MANUFACTURER'S RECOMMENDATIONS. 12, # 4 REBAR LOOPS AT 4 LOCATIONS. 20" SQ. COBBLE VENEER PILASTER SCALE: N.T.S. W LEGEND: 1, POURED CONCRETE MOW STRIP WITH FINE BRUSH FINISH. 2, #3 REBAR CONTINUOUS SET @ MID -DEPTH, 3. 1/2" BULLNOSE (TYPICAL). 4. FINISH GRADE, 5. 90% COMPACTED SUB -GRADE. NOTE: INSTALL CONTROL JOINTS @ V-0" O.C. MAX. SPACING AND AT ALL END OF CURB RETURNS. MOWSTRIP SCALE: N.T.S. SCALE: SCALE: NOTES; ALL SPLIT -FACE MASONRY WALL COLOR WILL BE ANGELUS #200 OR EQUAL, • ALL WALL HEIGHTS SHALL BE MEASURED FROM HIGHEST ADJACENT GRADE. • CONTRACTOR TO USE ANGELUS # 20010x4x16 BEVELED PRECISION MASONRY PRE -CAST WALL CAP OR EQUAL, REFER TO PROTO II DETAILS . 3 ATTACHED TO BACK OF PACKAGE SPLIT -FACE MASONRY WALL SCALE: N.T.S. PRIVATE SIDE — CFD LEGEND: 1. 2" sq. 12 GA, TUBULAR STEEL, TOP & BOTTOM RAILS. 2. 5/8" SQ.16 GA. TUBULAR STEEL FENCE PICKETS @ 4" o.c. MAX. TYPICAL- (4" CLR, MAX, OPENING ALLOWED BY CODE,) WELD PICKETS TO SIDE OF RAIL TO THE CFD SIDE OF THE FENCE, INSERT PLASTIC CAP. I 3. 2 SQ. 12 GA. TUBULAR STEEL FENCE POST @ 8-0' o.c, MAX w/ DECORATIVE CAP. 4. UNDISTURBED OR RECOMPACTED SUBGRADE PER STRUCT. SOILS REPORT. 5, CONCRETE FOOTING, FOOTING SHALL ACHIEVE 2000 PSI @ END OF 28 DAYS. CROWN TOP 1" TO DRAIN, 6. 12" WIDE x 4" THICK CONCRETE MAINTENANCE BAND w/ #3 CONTINUOUS REBAR. CROWN TOP TO DRAIN, SEE CONSTRUCTION LEGEND FOR REQUIRED LOCATIONS, WIDEN BAND WHEN ADJECENT TO SIDEWALK; ELIMINATING NARROW PLANTER ALONG WALKWAY. NOTE: ALL CONNECTIONS TO BE CONTINUOUS WELDED. REMOVE ALL SLAG & SPLATTER & GRIND ALL WELDS SMOOTH. PAINT STEEL WITH(1)COAT ZINC CHROMATE PRIMER & WITH (2) OATS ELECTRIC TUBULAR STEEL FENCE w/ MOWSTRIP SCALE: N.T.S. SCALE: SCALE: WATERPROOF EXPANSION JOINT COLD JOINT EXPANSION JOINT SCORE JOINT LEGEND: 1. CONCRETE PAVING. 2, 1/2" TOOLED RADIUS, 3, WATERPROOF SEALANT, COLOR TO MATCH PAVING. SUBMIT COLOR SAMPLES PRIOR TO INSTALLATION, 4, 1/4" POLY FOAM EXPANSION JOINT W/ TEAR -AWAY. TOP, SEE SPECS. 5. COMPACTED SUB -GRADE PER SOILS REPORT. CONCRETE JOINTS SCALE: N.T.S. NOTES: • ALL PRECISION MASONRY WALL COLOR WILL BE ANGELUS #200 OR EQUAL. • ALL WALL HEIGHTS SHALL BE MEASURED FROM HIGHEST ADJACENT GRADE. • CONTRACTOR TO USE ANGELUS # 20010x4x16 BEVELED PRECISION- MASONRY PRE -CAST WALL CAP OR EQUAL. REFER TO PROTO 1-1 DETAILS, ATTACHED TO BACK OF PACKAGE PRECISION MASONRY WALL SCALE: N.T.S. SCALE: SCALE: 1' TURF 2:O.C. LEGEND: 1. 1/2" RADIUS AT ALL EDGES. 2. NATURAL COLOR CONCRETE PAVING. SEE CONSTRUCTION PLAN FOR DIMENSIONS. 3. COMPACT EARTH TO 90% RELATIVE COMPACTION UNDER PAVEMENT. LEGEND: 1. MEDIUM BROOM FINISH NAT. COLOR CONCRETE, RUN PERPENDICULAR TO EDGE OF CONC,/PATH OP TRAVEL, 2. DEEP SCORE JOINTS; SEE CONST. PLAN FOR LAYOUT. 3. EDGE OF PAVING. L A N D S CA P E ARCHITECTURE SITE PLANNING 10621 Church St., Suite 106 Rancho Cucamonga, CA 91730 (909) 484-2800 Fax (909) 484-2802 of"� • Richard Krurr viede CA Lic. #2834 AZ Lic, # 29115 NV Lic, # 446 �Ytindr SO° TX. Lic. #1884 � A �PN'B S C A Ap 9 O ,um�,�q� feCOy U W � A. MEDIUM BROOM FINISH W/ DEEPSUOHE JOIN -US �P ��e "a0 Q � oeta a� o F c MEDIUM BROOM FINISH CONCRETE WALKWAY SCALE: N.T.S. SCALE: SCALE: r1pSCAPE\, J �Zj�. • RU t"9 LAJ fir. in or r �:ArVavr fiS� CITY OF FONTANA, CALIFORNIA DRAWN BY: SYCAMORE HILLS SCALE: KPF TRACT. # 16 -2 UNITY FACT S (STRICT 1" _ 20'-0" — DESIGNED BY: DATE: KPF 00 0_ d' 2/5/04 CHECKED BY: APPROVED DWG. NO.: JAF DATE; Z• CITY ENGINEER R.C.E. 51152 EXP. DATE 12/31/05 3552 /14 REVISIONS n , DRAWN BY DATE 0e SCALE s � JOB NUMBER o • SHEET NUMBER e � M U� T 00 0_ d' ®—'0 06 0- Cf) UW � �� W , Cf) CC E - CD � (D WCO fnO rn O� z z e--- O O w rL LO o M REVISIONS n , DRAWN BY DATE 0e SCALE s � JOB NUMBER o • SHEET NUMBER