HomeMy WebLinkAbout4814-30SEPTEMBER 2006.
3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAYS PRIOR TO REMOVAL OF
TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL.
4. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS, THE
STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA, THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES
FOR STREETS AND HIGHWAYS, DATED SEPTEMBER 2006, AND THE CALTRANS STD PLANS DATED MAY 2006.
5. TWO WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY ENGINEER (909) 350-7610 FOR APPROVAL OF CONTROL POINTS
OR "CAT TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING.
6. TRAFFIC SIGN SIZE SHALL BE FOR -CONVENTIONAL ROADWAYS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY
STANDARD DETAIL 4003.
7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY
STANDARD DETAIL 4003.
8. STENCILS USED FOR PAVEMENT MARKINGS MATCH CITY OF FONTANA STANDARD STENCILS.
9. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED.
10. CROSSWALKS SHALL HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE SHOWN ON THE PLANS,
PER CITY STANDARD DETAIL 1003.
11. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE
RECORD DRAWINGS AND ELECTRONIC AUTODESK CAD FILES, TO THE CITY ENGINEER.
12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE SANDBLASTED.
13. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 ON HIGHWAYS WITH RAISED
MEDIANS.
14. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD PLAN.
W4-71 E
SIGNING AND STRIPING PLAN CONSTRUCTION NOTES
INIONMINUM a
� ONLY � � p
t:
3 R4-7,
VINEYARD VALLEY TYPE K-1(CA)
R=200', L=34' 12 3 W12-1
(50)15 1
EX. CURB & GUTTER
(TO BE REMOVED)
R2-1(40),
R28(S)(CA)E '
VALLEY '
OMNI E R61-7(CA) 3
14 , 12
PR. R/W
R6-1Vv
'
R28(S)(CA), E EX. R/W PR. CURB &GUTTER
EX. CURB
' &GUTTER -
' --
- 29 - - -------- � ____ ___ "*��____ - _-4-1,
---------------------------------
L —
O
N
N
E (STRIPING y E IR5-2
• LINSCOIT, LAW & GREENSPAN, ENGINEERS
• TRANSPORTATION PLANNING - TRAFFIC ENGINEERING - PARKING
El 236 K Chester Avenue, Suite 200 Pasadena, Ca 91106 (626) 796.2322
■ Corporate Drive, Suite 122, Costa Mesa, Ca 92626 (714) 641-1587
2 Ruffner Street, Suite 100, San Diego, Ca 92111 (858) 300-8800
ii 06.zs. 09
D. MABERRY RTE 1802 DATE
7+00 ^
N
N
N
N
pQ�oFESFS,/94, 1
w WW� m
a✓ Y No. 1802
Exp 6/30/1 1
TRAFFIC
OF CA�-�F
R4-7, E
TYPE K-1(CA)
EIR28(S)(CA)
EX. CURB & GUTTER
EX. R/W
1
Timm
f 5' TYP.
a MAX
% a
O
` S
9+00
` I
1C3�
18 I
I
h'
24' 112' 12' 12'
15 (R=30')
12 (25)
EX. CURB & GUTTER
(TO BE REMOVED)
PR. CURB & GUTTER
F
O
BOULEVARD
EX. R/W
-EJR28(S)(CA)/_jER28(S)(CA) EX. CURB &GUTTER
EXISTING SIGN TO REMAIN
EXISTING SIGN TO BE REMOVED
PROPOSED SIGN
SIGNALIZED INTERSECTION
-----------
------------------------------
---------------- -
50� - - - - - - - - -
50' - - - - - - - - i1r)
10+00 110 12+00 I 13 0
N N
-------------------------------------------------------------
-
R
E W9 -2L E OMNI E R28(S)(CA) 4-7,TYPE K-1(CA) E E STRIPING
R4-7, E R2-1(40) R28(S)(CA) E
1 E TYPE K-1(CA) E_ R28(S)(CA)
19
E STRIPING
VINEYARD VALLEY
EX. CURB & GUTTER
EX. R/W
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON DRAWN BY:
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE DESIGNED BY:
PLANS TO BRING THEM INTO CONFORMANCE WITH CHECKED BY:
REV. REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT. IN p -
40'30'20' 10' 0' 40' 80'
GRAPHIC SCALE: 1"-40'
CITY OF FONTANA, CALIFORNIA
SNAgJC fl STRPNG MODFICATION PLAN
VALLEY BOULEVARD
AT VALLEY
APPR Y: DATE-
CITY ENGINEER R.C.E. 51152
m
0
W
t
Q_
rn
0
0
N
N
N
LO
0
0
J
C
T
0
U)
00
00
0)
N
C
CL
cn
C
0
c
En
/
C
U)
a)
/
/
00
00
0)
N
00
0
N
/
N
C
SCALE:
As Noted
DATE:
6-25-09
DRAWING NO.: 30
48141/32
EXISTING TO REMAIN UNLESS NOTED OTHERWISE.
I�1
REMOVE BY SANDBLASTING EXISTING STRIPING, MARKING, OR LEGEND, EXCEPT AS NOTED TO REMAIN.
REMOVE EXISTING PAVEMENT
MARKERS AS NECESSARY.
30
INSTALL NEW SIGN ONTO POST, STREET LIGHT POLE, OR TRAFFIC SIGNAL POLE, AS SHOWN.
5�
APPLY
THERMOPLASTIC
4" SOLID WHITE LINE.
12
APPLY
THERMOPLASTIC
4" DOUBLE YELLOW MEDIAN STRIPING PER CALTRANS STD PLAN A2013, DETAIL 29.
F151
APPLY
THERMOPLASTIC
8" SOLID WHITE CHANNELIZING LINE PER CALTRANS STD PLAN A20D, DETAIL 38.
n18
APPLY
THERMOPLASTIC
4" LANE LINE EXTENSION PER CALTRANS STD PLAN A20D, DETAIL 40.
19
APPLY
THERMOPLASTIC
TYPE IV (L) OR (R) ARROW MARKING PER CITY STD X -WALK PLAN 1003.
F 2A
APPLY
THERMOPLASTIC
TYPE IV (L) OR (R) ARROW MARKING PER CALTRANS STD PLAN A24A.
APPLY
THERMOPLASTIC
TYPE VII (L) OR (R) ARROW MARKING PER CALTRANS STD PLAN A24A.
Fib
Qj
APPLY
THERMOPLASTIC
TYPE I ARROW MARKING PER CALTRANS STD PLAN A24A.
INIONMINUM a
� ONLY � � p
t:
3 R4-7,
VINEYARD VALLEY TYPE K-1(CA)
R=200', L=34' 12 3 W12-1
(50)15 1
EX. CURB & GUTTER
(TO BE REMOVED)
R2-1(40),
R28(S)(CA)E '
VALLEY '
OMNI E R61-7(CA) 3
14 , 12
PR. R/W
R6-1Vv
'
R28(S)(CA), E EX. R/W PR. CURB &GUTTER
EX. CURB
' &GUTTER -
' --
- 29 - - -------- � ____ ___ "*��____ - _-4-1,
---------------------------------
L —
O
N
N
E (STRIPING y E IR5-2
• LINSCOIT, LAW & GREENSPAN, ENGINEERS
• TRANSPORTATION PLANNING - TRAFFIC ENGINEERING - PARKING
El 236 K Chester Avenue, Suite 200 Pasadena, Ca 91106 (626) 796.2322
■ Corporate Drive, Suite 122, Costa Mesa, Ca 92626 (714) 641-1587
2 Ruffner Street, Suite 100, San Diego, Ca 92111 (858) 300-8800
ii 06.zs. 09
D. MABERRY RTE 1802 DATE
7+00 ^
N
N
N
N
pQ�oFESFS,/94, 1
w WW� m
a✓ Y No. 1802
Exp 6/30/1 1
TRAFFIC
OF CA�-�F
R4-7, E
TYPE K-1(CA)
EIR28(S)(CA)
EX. CURB & GUTTER
EX. R/W
1
Timm
f 5' TYP.
a MAX
% a
O
` S
9+00
` I
1C3�
18 I
I
h'
24' 112' 12' 12'
15 (R=30')
12 (25)
EX. CURB & GUTTER
(TO BE REMOVED)
PR. CURB & GUTTER
F
O
BOULEVARD
EX. R/W
-EJR28(S)(CA)/_jER28(S)(CA) EX. CURB &GUTTER
EXISTING SIGN TO REMAIN
EXISTING SIGN TO BE REMOVED
PROPOSED SIGN
SIGNALIZED INTERSECTION
-----------
------------------------------
---------------- -
50� - - - - - - - - -
50' - - - - - - - - i1r)
10+00 110 12+00 I 13 0
N N
-------------------------------------------------------------
-
R
E W9 -2L E OMNI E R28(S)(CA) 4-7,TYPE K-1(CA) E E STRIPING
R4-7, E R2-1(40) R28(S)(CA) E
1 E TYPE K-1(CA) E_ R28(S)(CA)
19
E STRIPING
VINEYARD VALLEY
EX. CURB & GUTTER
EX. R/W
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON DRAWN BY:
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE DESIGNED BY:
PLANS TO BRING THEM INTO CONFORMANCE WITH CHECKED BY:
REV. REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT. IN p -
40'30'20' 10' 0' 40' 80'
GRAPHIC SCALE: 1"-40'
CITY OF FONTANA, CALIFORNIA
SNAgJC fl STRPNG MODFICATION PLAN
VALLEY BOULEVARD
AT VALLEY
APPR Y: DATE-
CITY ENGINEER R.C.E. 51152
m
0
W
t
Q_
rn
0
0
N
N
N
LO
0
0
J
C
T
0
U)
00
00
0)
N
C
CL
cn
C
0
c
En
/
C
U)
a)
/
/
00
00
0)
N
00
0
N
/
N
C
SCALE:
As Noted
DATE:
6-25-09
DRAWING NO.: 30
48141/32