Loading...
HomeMy WebLinkAbout4687-1CONDUCTOR SCHEDULE A.P.G. SIZEpOLE OR RUNS CABERSIZE CIRCUIT AiQQQQQQQQ REFLECTIVE STREET NAME SIGN 1 1 U 1 ' 1 SIGNAL MAST ARM LUMINAIRE MAST ARM "A" "B" w P0LE O m � 1 ARROW QUAD 1 1 1 1 15' EX. 05 1 06 11 07 1 08 SP -1-T 1 1 1 1 0 POLE O2 1-A 10' - - EX. 1 1 1 TV -2-T C 6 blue and green. Install one 6 pair #22 SIC in the orange E - - 3 1 1 1 15' POLE EX. 2 -MAS EX. SV -1 -CS SP -1-T 6 -a*— E 250W N 12 0 D 1-A 10' - - EX. EX. - - TV -2 -CS SP -1-T 8 —► S - - 5 61A-5-80 35' 60' 15' U DPow EX. 2 -MAS EX. SV -1-T SP -1-T 8 -m-- S 250W Slover Ave C T C 1-A 10' - - EX. 1 1 1 TV -2-T SP -1-T Porgy ---ANN-W - - 7 29A-4-100 35' 55' 15' R 3 O 4' 16'SV- 1 1 2 �— W (R) 250W (R) Citrus Ave (N) POLE O6 30 30' 1 1 1/1 1 V11 L1111 1S 1 - _ _2T R 4 —► N (R) 250W (N)TYPE - Pow O Y10 S Y10 1 Y10 Y10 Y10 POLE O 10 Y10 10 10 10 1° 1° 1 1° 1 1 1 1 TOTAL CABLES 12C/3C 1 1 2 2 3 3 4 4 5 5 8 8 8 8 2 2 1 1 #10 LUMINAIRES 'Zo 20 2 2 2 4 _ 2 2 VIDEO CABLE - 1 1 2 2 4 4 1 1 VIDEO POWER CABLE - 1 1 2 2 4 4 1 1 EVP CABLE - 1 1 2 2 4 4 1 1 CONDUIT SIZE (in.) �N) 2 (N) 3 (E) 3 (E) 4 (E) 4 (E) 2-4 (E) 2-4 (E) 3 (E) 2 ALL CONDUCTORS ARE EXISTING UNLESS OTHERWISE NOTED. oNEW CONDUCTORS (E) EXISTING (N)=NEW GENERAL NOTES 1. Traffic signal, signing and striping, and lighting shall conform to these plans, the Special Provisions, the City of Fontana Standard Details, and the State of California Standard Specifications Section 86 (dated May 2006) and Standard Plans (dated May 2006), the California Manual on Uniform Traffic Control Devices (MUTCD) for streets and highways dated January 2010. 2. Location of all underground facilities are approximate. The Contractor shall pothole to determine theexact location and verify all conditions on the job site. Hand dig foundations until clear of any obstructions. Phone Underground Service Alert (800) 226-2700, two working days before digging. 3. All pull boxes shall be No.6 and conduit shall be 2" rigid metal unless otherwise shown. 4. The Contractor shall make application for electrical service and T^ scheduling with Southern California Edison Company four weeks in V1 advance of need. 5. The Contractor shall obtain approval from the Engineer for exact equipment locations prior to final placement. See detail on this sheet. 6. All required construction permits shall be obtained from the City of Fontana Engineering Division prior to commencement of work. 7. The Contractor shall relocate and/or replace landscaping, sprinklers, and sidewalk affected by the construction to the satisfaction of the Engineer. 8. The controller cabinet shall not be subjected to water from sprinklers. The Contractor shall modify sprinkler systems if necessary. 9. The alignment of interconnect ducts shall be as straight as possible. However, when changes in alignment are necessary, sweeps shall have minimum radii of 3 feet. 10. All vehicle indications shall be 12" and have L.E.D. signal modules. All pedestrian heads shall have L.E.D. pedestrian modules and utilize pedestrian countdown timers per the Special Provisions. 11. Any existing traffic signals and lighting shall remain in -operation until replaced with new construction. 12. The Contractor shall furnish all equipment, materials, and hardware to construct the traffic signal and lighting as shown on the plans, except as noted city furnished or listed as city provided in the Special Provisions. 13. The Contractor shall refer to the City Traffic Engineer in the event of a conflict or potential conflict with these plans and/or specifications for this project. 14. Where traffic signal street crossing conduits are not installed using the boring method, trench repairs shall be per detail this sheet, and Special Provisions, Section E. 15. Traffic sign size shall be for conventional roadways unless otherwise shown on the plans. PHASE DIAGRAM 01 02 03 04 , , , m 1 , 1 REFLECTIVE STREET NAME SIGN 1 1 U 1 ' 1 SIGNAL MAST ARM LUMINAIRE MAST ARM "A" "B" w "F" m � 1 ARROW QUAD 1 26A-4-80 35' 45' 15' EX. 05 1 06 11 07 1 08 CITRUS AVENUE 4 I I 1 1 I I I 1 1 1 I I 1 1 1 1 I 1 1 1 1 I �+ 32' n I I 1 1 I I 1 1 1 1 1 I 1 1 1 I I I 1 I I I 1 I 1 I 1 I 1 1 1 I 1 1 1 I 1 1 1 I 1 I 1 I 1 I 1 I - 1 T. 1 L__ I �}-- - - - - -------r-----------------------�--r---{---- ; 1 1 1 I I 1 1 1 1 1 I -- 1 I I 1 I f 12' 12' 1 ' f 44' ' 1 I 1 1 I `, 1 I 1 1 1 I 1 1 1 1 I 4 1 1 I 1 1 1 1 I I 1 1 _ 1 1 I I 1 1 I _ �__ ______.,1 --- .r--- .5" EXISTING 1 C & - - EX. 2" C' 2#10 (LIGHTING) SERVICE CONDUCTORS / 06 ---� 1 I O II I EXISTING R 13A R35/' 5 tit 4 -WAY SIGNAL 4 , 5; :102 ; . . . . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. .. . , � TV P48 SPLICE VAULT SIGNS ON SIGNAL POLE I ' EX. C&G SEE SHEET 5 OF 6 ' 5 7 6' FOR INSTALLATION 3 R W 0 �o-o�o,ltlllllllltlllll� o �oo>_o�o o>•4-oo>_�oo>_.o o�A 1 1 i 1 1 1 1 ,ofb X. 2C, 2 ERVICE) 2#8 G.F.C.I.) NEW SIGN , i A� I I 1 1 I 1 , I I 1 t 1 , -------------------- -L--- ---�- -'1--- '-j---------------------� ; • t , I I ; ; ; ; ,; w I 1 I 1 I 1 I I +,lr 5 -+ POLE AND EQUIPMENT SCHEDULE 1 1 1 1 1 1 1 1 1 I I 1 1 I 1 1 1 I 1 1 I , I , I , 1 � I I I I 1 I I I I I I I I I 1 1 SIGNAL STANDARD I 1 I I I 1 1 1 , , , PED PUSH BUTTONS 1 , 1 REFLECTIVE STREET NAME SIGN 1 1 U 1 ' 1 SIGNAL MAST ARM LUMINAIRE MAST ARM "A" "B" w "F" POLE VEHICLE � 1 n I I 1 1 I I 1 1 1 1 1 I 1 1 1 I I I 1 I I I 1 I 1 I 1 I 1 1 1 I 1 1 1 I 1 1 1 I 1 I 1 I 1 I 1 I - 1 T. 1 L__ I �}-- - - - - -------r-----------------------�--r---{---- ; 1 1 1 I I 1 1 1 1 1 I -- 1 I I 1 I f 12' 12' 1 ' f 44' ' 1 I 1 1 I `, 1 I 1 1 1 I 1 1 1 1 I 4 1 1 I 1 1 1 1 I I 1 1 _ 1 1 I I 1 1 I _ �__ ______.,1 --- .r--- .5" EXISTING 1 C & - - EX. 2" C' 2#10 (LIGHTING) SERVICE CONDUCTORS / 06 ---� 1 I O II I EXISTING R 13A R35/' 5 tit 4 -WAY SIGNAL 4 , 5; :102 ; . . . . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. .. . , � TV P48 SPLICE VAULT SIGNS ON SIGNAL POLE I ' EX. C&G SEE SHEET 5 OF 6 ' 5 7 6' FOR INSTALLATION 3 R W 0 �o-o�o,ltlllllllltlllll� o �oo>_o�o o>•4-oo>_�oo>_.o o�A 1 1 i 1 1 1 1 ,ofb X. 2C, 2 ERVICE) 2#8 G.F.C.I.) NEW SIGN , i A� I I 1 1 I 1 , I I 1 t 1 , -------------------- -L--- ---�- -'1--- '-j---------------------� ; • t , I I ; ; ; ; ,; w I 1 I 1 I 1 I I +,lr 5 -+ POLE AND EQUIPMENT SCHEDULE POLE SIGNAL STANDARD PLACEMENT DIMENSIONS SIGNAL MOUNTING PED PUSH BUTTONS HPSV LUMINAIRE REFLECTIVE STREET NAME SIGN N0. POLE TYPE POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM "A" "B" MAST ARM VEHICLE "F" POLE VEHICLE POLE EDESTR0 ARROW QUAD 1 26A-4-80 35' 45' 15' EX. EX. 2 -MAS EX. SV- 1-T SP -1-T 4 -a*--N 250W Slover Ave 2 1-A 10' - - EX. EX. - - TV -2-T SP -1-T 6 blue and green. Install one 6 pair #22 SIC in the orange E - - 3 26A-4-80 35' 45' 15' EX. EX. 2 -MAS EX. SV -1 -CS SP -1-T 6 -a*— E 250W Citrus Ave (N) 4 1-A 10' - - EX. EX. - - TV -2 -CS SP -1-T 8 —► S - - 5 61A-5-80 35' 60' 15' EX. EX. 2 -MAS EX. SV -1-T SP -1-T 8 -m-- S 250W Slover Ave 6 1-A 10' - - EX. EX. - - TV -2-T SP -1-T 2 ---ANN-W - - 7 29A-4-100 35' 55' 15' 24' 4' 16'SV- 2 �— W (R) 250W (R) Citrus Ave (N) 8 30 30' - 5, 21' 3' - - _ _2T _ _ SP1T 4 —► N (R) 250W (N)TYPE - EXISTING SERVICE P.P. #4310745E EXISTING GUARD RAIL ALL EQUIPMENT IS EXISTING UNLESS OTHERWISE INDICATED. �N� =NESP R = RELOCATED EXISTING 1.5" C & SERVICE CONDUCTORS EXISTING R81/R35/'4-WAY SIGNAL" SIGNS ON SIGNAL POLE O 3 8 TO CONTROLLER AT ENTRANCE = ♦ B SEE SHEET 3 OF 6 FOR INSTALLATION 1 ' 114-� W 1 i / \ ' 00 00 0>• o>• 00 0 6 w 08 1 I _ 1 1 t 1 t 1 - t 1 t 1 w t 1 t 1 t 1 t t 1 1 1 1 1 1 1 1 1 I 1 1 1 ' I 1 1 1 _________ _ ___ ____________________.�________ '_ '_-_-_..ia'�______________ ____ ____- I 1 1 ------------------ 1 1 1 1 I 1 I 1 2 1 1 1 1 I 1 --------- --------------------------- ----'- '---------------------------------------------- --- ---- ----- (J� I I I 1 I y � 1 Y 7 I 1 1 1 4 ---DIY I I ,,, C � Ftt---+ I 1 I 1 I 1 R3-41: I----- --- ----- -------------------------I I ---------------------------------------' 1 ; 1 0,0 8 , , 1 •-±� I I •>----�-------------� w 1 ;' • I -----------------;----- ---------------------------------------------------I----------------- ------ 4--- / I _____ _____ __________________- __ ' _______________________J_ _L ------- -------- . -- ;--- ------ -------------------- I --------- ------------- --------------------------J- J--- - r-- L -- -------------i'=-- ------ I ,� I ___ ____ _____ _____________________ _,f_________ I - ------ ;--EXIT tN _43:4 _SAY_-iGIYAV L__'_0-------------- ---- ' w .y ►� I IGN:�' ON ; SIGNAL POLE--- _ --- - ,Ly t ------------------ -----------�--1'----- -- .' ;(.!IT ' ----- ------ i------ ---- --- I 1 I ---' ' ------------------- ---------T----- 1 I ,' ;T; -, -- 0 6 4 O ' L7d L7J I , 1 1 J r_ EX. C&G 8 / 3 Curb/Berm flow or edge of shoo 1. , EXISTING R35/'4 -WAY SIGNAL" SIGNS ON SIGNAL POLE U w Typical signal placement unless dimensions noted on plans. NOTE: For "Y& B" dimensions refer to POLE SCHEDULE, or as directed by the Engineer. Negative "A" refer to a distance departing intersection away from BC or EC. SIGNAL STANDARD PLACEMENT DIMENSIONS AND EQUIPMENT LOCATIONS VAR. 1 1 1 I 1 I 1 I 1 I I 1 I I 1 1 1 I I I 1 t I I t 1 1 1 1 1 1 I I I 1 1 1 1 I 1 1 I 1 1 1 I I t I 1 1 I I 1 t I I I t I 1 1 1 of 1111 1 I I I 1 I I I I I I t 1 I I 1 1 I 1 1 I 1 1 1 I 1 1 I I 11 I I 1 1 I I I CRUS AVENUE NEW C&G � R/W Legends for OVERHEAD STREET NAME SIGNS Location: Citrus Avenue and Slover Avenue 3Ave CitruS 10400 North West Corner Ave FoNTANA Citru S 10500 South East Corner EMERGENCY VEHICLE PRE-EMPTION DETECTO] MAST ARM E.V.P. MOUNTING DETAIL N.T.S u CONSTRUCTION NOTES �1 Existing TYPE 90 controller in a TYPE "P" cabinet. Existing . TYPE III -BF Service Equipment Enclosure. Install new pole, signal mast arm and luminaire mast arm v on new foundation and anchor bolts. EVP and other salvaged equipment. See POLE AND EQUIPMENT SCHEDULE. w Z ® Install new pole, luminaire mast arm and salvaged _ _ equipment on new foundation and anchor bolts. 5❑ Install 2" conduit and 6 pair #22 SIC. © Install 6 - 1.5" Schedule 40 HDPE conduits per - DETAIL "B". The conduits shall be color coded orange, yellow, red, black, blue and green. Install one 6 pair #22 SIC in the orange conduit. Salvage the existing pull ropes in the remaining conduits for future cable. �7 Remove existing foundation. GRAPHIC SCALE � ® existing pedestrian indicator. Install new Remove and salvage g 0' pedestrian countdown timers per Special Provisions. Contact City of Fontana Traffic Division, Darrin Huggins at (909) io o s io 20 40 0 350-6525 for salvage and disposal of equipment. - �i (IN FEET) 1 INCH = 20 FEET