Loading...
HomeMy WebLinkAbout4765-39 160 N. Riverview Drive, Ste. 100 Anaheim Hills, California 92808 _J r (114) 685-6860 DRC Engineering Inc. Civil Engineering/Land Surveying/Land Planning TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT EXISTING STREET 1 1^1 IT AND GUTTER FUTURE STREET o CROWN LINE 4 h �EXISTING R/W OCURB RAMP DETAIL CONSTRUCTION NOTES: O1 CONSTRUCT CONCRETE CURB AND GUTTER, 8" CF PER CITY STD. NO. 1003. O4 CONSTRUCT COMMERCIAL DRIVEWAY ENTRANCE PER CIN STD. N0. 1002 (W=PER PLAN) O5 CONSTRUCT CURB RETURN ACCESS RAMP PER CIN STD. N0. 1004 AND DETAIL SHEET 3 O7 INSTALL DETECTABLE WARNING SURFACE PER CBC 11338.8.5 ® CONSTRUCT CONCRETE SIDEWALK, WIDTH = 5' PER CITY STD. NO. 1006. O9 CONSTRUCT 4.5" MIN AC OVER 12" MIN OF 95% COMPACTED NATIVE LEGEND: REMOVE EXISTING INTERFERING PORTIONS OF AC PAVEMENT, C&G, AC BERM AND CONCRETE SIDEWALK, ETC. PROPOSED AC PAVEMENT LA LANDSCAPE AREA GRAPHIC CURVE TABLE 20 0 10 20 40 CURVE LENGTH RADIUS DELTA TANGENT C7 34.10' 38.00' 51'24'44" 18.29' C8 5.22' 6.00' 49'48'10" 2.79' C9 43.25' 38.00' 65'12'20" 24.31' C10 6.81' 6.00' 65000'53" 3.82' C11 53.27' 38.00' 80'18'58" 32.82' C12 15.92' 55.00' 16'35'01" 8.02' C13 84.98' 235.62' 69'20'03" 42.96' CONSTRUCTION NOTES: O1 CONSTRUCT CONCRETE CURB AND GUTTER, 8" CF PER CITY STD. NO. 1003. O4 CONSTRUCT COMMERCIAL DRIVEWAY ENTRANCE PER CIN STD. N0. 1002 (W=PER PLAN) O5 CONSTRUCT CURB RETURN ACCESS RAMP PER CIN STD. N0. 1004 AND DETAIL SHEET 3 O7 INSTALL DETECTABLE WARNING SURFACE PER CBC 11338.8.5 ® CONSTRUCT CONCRETE SIDEWALK, WIDTH = 5' PER CITY STD. NO. 1006. O9 CONSTRUCT 4.5" MIN AC OVER 12" MIN OF 95% COMPACTED NATIVE LEGEND: REMOVE EXISTING INTERFERING PORTIONS OF AC PAVEMENT, C&G, AC BERM AND CONCRETE SIDEWALK, ETC. PROPOSED AC PAVEMENT LA LANDSCAPE AREA GRAPHIC 20 0 10 20 40 so ( INS) 1 inch = 20 & REV. REVISION DESCRIPT10N DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL� Q Tscy STREET IMPROVEMENT PLANS SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, ee ��• C9_ Q N �� DRAWN BY: � CM SCALE: AS SHOWN No. 45715 R.C.E. 45715 THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO Exp. 12-31-10 DESIGNED BY-- DATE: 7/26/ 26 10 / / BRING THEM INTO CONFORMANCE WITH CONDITIONS AND Z�r 9TFoF CA��F RC Date : 712VIO CHECKED BY: AP ROVED 3 �0 DRAWING NO.: 3 STANDARDS I N EFFECT. -RV 4765 31 CITY ENGINEER RCE 51152 DATE: