Loading...
HomeMy WebLinkAbout3249-5U U � 31 00 3 � � v m IY J L, W m NOTES I. IF H IS LESS THAN 450 mm OWL W=675 mm (27') IF H IS BETWEEN 450 mm (181 AND 750 mm (2'-60), W=750 mm (2'-60).. IF H IS 750 mm (2'-61) OR MORE, W=900 mm (3'-0'). IF H IS MORE THAN 1215 mm (4'-0 1/2'). BRING WALL VERTICALLY TO 1215 mm (4'-0 1/2') BELOW SURFACE AND TAPER FROM 900 mm (3'-08) TO 675 mm (27') AS SHOWN. 2. THIS STRUCTURE SHALL BE USED WITH MANHOLE FRAME AND COVER PRESSURE TYPE. STANDARD PLAN 211. IT MAY BE USED FOR HYDRO- STATIC HEADS UP TO 7.5 m (25') ABOVE THE STEEL PLATE. 3. THE VERTICAL SIDE OF THE MANHOLE SHAFT AND THE ECCENTRIC REDUCER SHALL BE LOCATED ABOVE AND IN LINE WITH THE SIDE OF THE STORM DRAIN CONDUIT. 4. REINFORCEMENT SHALL CONFORM TO ASTM A 615M, GRADE 300(ASTM A 615, GRADE 40). AND SHALL TERMINATE 40 mm (1 1/21 CLEAR OF CONCRETE SURFACES UNLESS OTHERWISE SHOWN. 5. STEPS SHALL CONFORM TO STANDARD PLAN 635 OR 636. THE TOP STEP SHALL BE PLACED DIRECTLY BENEATH THE MANHOLE FRAME. UNLESS OTHERWISE SHOWN. STEPS SHALL BE UNIFORMLY SPACED 350 mm (140) TO 375 mm 051 OC. 6. SEE CONTRACT SPECIFICATIONS FOR PHYSICAL REQUIREMENTS OF WATERSTOP. 7. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN: 2 1 1 MANHOLE FRAME AND COVER PRESSURE TYPE 635 STEEL STEP 636 POLYPROPYLENE PLASTIC STEP AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN MET IC 328 -1 SHEEi20F2 PRESSURE MANHOLE SHAFT WITH ECCENTRIC REDUCER At _ to PLAN 15M O 300 mm (04 O MANHOLE FRAME AND 121 HOOPS COVER PRESSURE TYPE E iv PER STD. PLAN 211 200 teal 686 mm 200 mre � m (8•) (27.1 (e•1 SURFACE ELEVATION D - 952 mm (37 3/4') io n T4. STEPS 0 ZD gS 123 tta (S'I D - 1013 mm (40 3/80) z1 65 mm (2 1/2') D - 1074 mm (431 6-15M04) O 600 SPACING 73�* I OPTIONAL 15 M04) 375 mm 05'1 DOWEL (3.1 125 tree 5.1 -- D = 1135 mm (45 1/21 LO MANHOLE OR N I STORM DRAIN n - i; I CONDUIT PROVIDE CONSTRUCTION JOINT 50 65 mm1 WITH CONTINUOUS WATERSTOP (18') 2 I/2')I WHEN MANHOLE SHAFT IS NOT 200 mm W0000 mm POURED MONOLITHIC WITH SEE NOTE I (81 •) MANHOLE OR STORM DRAIN CONDUIT SECTION A -A ELECTRICALLY BUTT WELD ENDS OR LAP ENDS OF BAR 450 mm U8•) 15M(•4) HOOP BARS AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE PRESSURE MANHOLE SHAFT WITH STANDARD "'" PUBLIC ENBOOXCORKS ANDARDs.NC.. GREENBOOK COMMITTEE ECCENTRIC REDUCER 328-1 1992 rA= USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION REV. 1998USE SHEET 1 OF 2 WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION AAAAAAAA !Q , TOLL FREE `0=00`1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT PRESSURE MANHOLE SHAFT, 5 NOT TO scue CONCRETE COLLAR DETAIL NOT TO SCALE 3 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. 15M O 300 mm 04 O 1 L/2 (TYP.)----% NEW OR o EXIST. PIPE FLOW A 15M O 300 mm (#4 O 12') --J. SO <A -3-15M (94) CIRCULAR TIES, SEE NOTE 9 150 mm 6') MIN CUT - NO. 2 CUT N0. I LINE 4 N 9CUT 0, NO. 2 zl LINE 150 mm CUT N( 6') MIN DETAIL "A' (SEE NOTE 10) SONO -TUBE. OR EQUAL. INTERIOR FORM CUT NO. 1: SAW THE TUBE AT AN ANGLE OF A/2 WITH THE TRANS- VERSE PLANE. REVERSE ONE SECTION AND TAPE BOTH SECTIONS TOGETHER FORMING THE DEFLECTION ANGLE A. CUT NO. 2: SAW THE TUBE LONGITUDINALLY REMOVING A STRIP 3.14 (DO -D ) WIDE ON THE SIDE OPPOSITE THE OPEN JOINT. BEND THE ENDS OF THE CUT TOGETHER AND INSERT THE TUBE IN THE PIPE. 330-C-23 (560-C-3250) CONCRETE 25 mm (I') (TYP.) D L T 300 mm (12.) 300 mm 021 100 mm (4.1 450 mm 081' 300 mm (12') 125 mm (50) 600 mm (249 300 mm (12') 150 mm (61 750 mm (301) 450 mm (181) 175 mm (71) 900 mm (36') 450 mm (181) 225 mm (96) 1050 mm (420) 450 mm (I80) 225 mm (9.1 1200 mm (48') 450 mm (180) 250 mm 009 1425 mm (57') 450 mm (18') 250 mm 009 1500 mm (60*1 525 mm (21') 275 mm (110) 1650 mm (66*1 525 mm (21') 275 mm (1111 1800 mm (721) 600 mm (24-1300 mm (12.) INTERIOR SURFACE OF PIPE DETAIL "B' TYPICAL JOINT FOR REINFORCED CONCRETE PIPE AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER REVISION DESCRIPTION CONCRETE COLLAR FOR RCP STANDARD PLAN PUBLIC WORKS STANDARDS INC., GREENBoITTEE VAR METRIC 380 - 2 Owl rA= USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CONCRETE COLLAR DETAIL NOT TO SCALE 3 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. 15M O 300 mm 04 O 1 L/2 (TYP.)----% NEW OR o EXIST. PIPE FLOW A 15M O 300 mm (#4 O 12') --J. SO <A -3-15M (94) CIRCULAR TIES, SEE NOTE 9 150 mm 6') MIN CUT - NO. 2 CUT N0. I LINE 4 N 9CUT 0, NO. 2 zl LINE 150 mm CUT N( 6') MIN DETAIL "A' (SEE NOTE 10) SONO -TUBE. OR EQUAL. INTERIOR FORM CUT NO. 1: SAW THE TUBE AT AN ANGLE OF A/2 WITH THE TRANS- VERSE PLANE. REVERSE ONE SECTION AND TAPE BOTH SECTIONS TOGETHER FORMING THE DEFLECTION ANGLE A. CUT NO. 2: SAW THE TUBE LONGITUDINALLY REMOVING A STRIP 3.14 (DO -D ) WIDE ON THE SIDE OPPOSITE THE OPEN JOINT. BEND THE ENDS OF THE CUT TOGETHER AND INSERT THE TUBE IN THE PIPE. 330-C-23 (560-C-3250) CONCRETE 25 mm (I') (TYP.) D L T 300 mm (12.) 300 mm 021 100 mm (4.1 450 mm 081' 300 mm (12') 125 mm (50) 600 mm (249 300 mm (12') 150 mm (61 750 mm (301) 450 mm (181) 175 mm (71) 900 mm (36') 450 mm (181) 225 mm (96) 1050 mm (420) 450 mm (I80) 225 mm (9.1 1200 mm (48') 450 mm (180) 250 mm 009 1425 mm (57') 450 mm (18') 250 mm 009 1500 mm (60*1 525 mm (21') 275 mm (110) 1650 mm (66*1 525 mm (21') 275 mm (1111 1800 mm (721) 600 mm (24-1300 mm (12.) INTERIOR SURFACE OF PIPE DETAIL "B' TYPICAL JOINT FOR REINFORCED CONCRETE PIPE AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER BYTFIE CONCRETE COLLAR FOR RCP STANDARD PLAN PUBLIC WORKS STANDARDS INC., GREENBoITTEE 300 mm 12" THROUGH 1800 mm 72" METRIC 380 - 2 1992 1892 REV. 1998 SHEET 1 OF 2 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION NOTES 1. A CONCRETE COLLAR IS REQUIRED WHERE THE CHANGE IN GRADE EXCEEDS 10 PERCENT. 2. FOR CURVE JOINTS (SEE DETAIL B. SHEET 1) IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE THAT IS GREATER THAN 25 mm (11. BUT IS LESS THAN 75 mm((30) A CONCRETE COVER IS REQUIRED IN ACCORDANCE WITH SUBSECTION 306-1.2.4 OF THE SSPWC. IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE THAT IS EQUAL TO OR GREATER THAN 75 mm (30). BUT LESS THAN 150 mm (61. A CONCRETE COLLAR IS REQUIRED. IF THE CLEAR SPACE IS 150 mm (61 OR GREATER. A TRANSITION STRUCTURE IS REQUIRED. 3. CONCRETE COLLAR SHALL NOT BE USED FOR A SIZE CHANGE ON THE MAIN LINE. 4. CONNECTOR PIPES A. WHERE PIPES OF DIFFERENT DIAMETERS ARE JOINED WITH A CONCRETE COLLAR, L AND T SHALL BE THOSE OF THE LARGER PIPE. D= D1 OR D2. WHICHEVER IS GREATER. B. WHEN DI IS EQUAL TO OR LESS THAN 102. JOIN INVERTS AND WHEN DI IS GREATER THAN D2. JOIN SOFFITS. 5. FOR PIPE LARGER THAN 1800 mm (72') SPECIAL COLLAR DETAILS ARE REQUIRED. 6. FOR PIPE SIZE NOT LISTED USE NEXT SIZE LARGER. 7. REINFORCEMENT SHALL CONFORM TO ASTM A 615 M (A 615) GRADE 300(40). 8. WHERE REINFORCING IS REQUIRED THE DIAMETER OF THE CIRCULAR TIES SHALL BE D+(2X WALL THICKNESS) + T. - 9. REINFORCING SHALL BE USED WHERE THE PIPE DIAMETER IS GREATER THAN 525 mm (210) AND ON ALL PIPES WHERE THE SPACES BETWEEN THE EXTREME OUTER ENDS IS 75 mm (30) OR LARGER. CIRCULAR TIES: PIPE DIAMETER NO. OF CIRCULAR TIES 525 mm (211 OR LESS 3 600 mm (240) TO 750 mm (301 3 825 mm (332) TO 1425 mm (57') 4 1500 mm (609 TO 1800 mm (720) 5 WHERE THE SPACE BETWEEN PIPE ENDS EXCEEDS 75 mm (30). THE NUMBER OF CIRCULAR TIES SHALL BE INCREASED TO MAINTAIN AN APPROXIMATE SPACING OF 150 mm (61 O.C. 10. WHERE THE PIPE IS 525 mm (211 OR LESS IN DIAMETER AN INTERIOR FORM OF UNSEALED SONO -TUBE OR EQUAL SHALL BE USED TO PROVIDE A SMOOTH INTERIOR JOINT. THE PAPER FORM MAY BE LEFT IN PLACE (SEE DETAIL A). WHEN THE PIPE IS 600 mm (24') OR LARGER A REMOVABLE INTERIOR FORM SHALL BE USED OR THE INTERIOR JOINT SHALL BE COMPLETELY FILLED WITH MORTAR AND NEATLY POINTED. II. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES: IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN METRIC SHEET 2 OF 2 CONCRETE COLLAR FOR RCP380-2 .300 mm 12" THROUGH 1800 mm 72" Q�pEESSIO e�k9� alfa>�lfltR/7N170I1 p F 11331 WEST SIXTH STREET, ONTARIO, CA 91762 J'�11 k / I - _Iwl (9 933-5225, (909) 933-5228 FAX repared Under The Supervision Of Exp. 9/30/05 b 9TF C!V\P �F CA1-� ___ C D - . - . k� CITY OF FONTANA, CALIFORNIA CITRUS AVENUE STORM DRAIN IMPROVEMENTS DRAWN BY CONSTRUCTION DETAILS/ SCALE: DESIGNED BY: RA A A STA DETAILS DATE. NO SCALE V RE A NUE 6/03 _ CHECKED BY: Date : (-1R' oJ ROVED B. DRAWING NO.: 5 'Vf)"5 3249 JL CITY NGIN ER R.C.E. 51152 DATE: 22