Loading...
HomeMy WebLinkAbout4797-24CONDUCTOR SCHEDULE A.W.G. SIZE POLE OR RUNS cnsiE srzE CIRCUIT AiQ NON -ILLUMINATED STREET NAME SIGN QQQQQ TYPE POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM Q QQ MAST ARM VEHICLE "F'' POLE O 1 1 1 1 1 26A-4-100 NOT USED 45' 15' 12' C 2 -MAS 1 1 1 1 1 08 250W Knox Ave 11. Any existing traffic signals and lighting shall remain in operation POLE O All pull boxes shall be No. 6 and conduit shall be 2" rigid metal 1 1 1 1 12. Q C 4. - 1 1 1 1 15' 12' 4' MAS - Porgy SP -1-T 6 f S 250W So Highland Ave D 1-A 10' - N 12 p U D 4' - - TV -2-T SP -1-T 2 —� W - - E Pow 35' 45' 15' 10' 2 -MAS 18' SV- 1-T SP -1-T 2 C T C W 250W Knox Ave F 1-A 10' - - 10' 4' - POLE OE TV -2-T SP -1-T 4 N - - G 1 35' R 3 0 12' 10' 6' MAS - SV- 1-T SP -1-T 4 �— 1 250W Pow H 1-A 10' - - 10' 4' - - TV -2-T S SPOLE OG E - - 1 1 1 1 1 1 Ppm O 1 1 1 1 1 1 1 1 TOTAL CABLES 12C/3C 1 1 2 2 3 3 4 4 4 4 1 1 2 2 3 3 4 4 _ #10 LUMINAIRES 2 2 2 2 - - 2 2 - - VIDEO COAXIAL CABLE 1 1 2 2 - - 2 2 - 4 VIDEO POWER CABLE 1 1 2 2 - - 2 2 - 4 OPTICOM CABLE 1 1 2 2 - - 2 2 - 4 CONDUIT SIZE (111.) 3 3 3 3 3 3 3 3 3 3 -N- GRAPHIC SCALE 10 0 5 10 20 40 (IN FEET) 1 INCH = 20 FEET KNOX AVENUE a I III PHASE DIAGRAM 01 02 03 04 NOT m HPSV LUMINAIRE NON -ILLUMINATED STREET NAME SIGN USED TYPE POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM "A" "B" MAST ARM VEHICLE "F'' POLE VEHICLE POLE EDESTR Qs ARROW QUAD A 26A-4-100 NOT USED 45' 15' 12' 4' 2 -MAS 18' SV -1-T 05 06 07 08 BZW NEW C&G :I :: — — A. ....... ...... ...... ...... ............. ... O• .7 h w NEW CURBED MEDIAN � I I low— w w c 150' d+ w w � o ¢O ,.,..._ . : r......-- ... O: .,.,,.. R W EX. C & G CONSTRUCTION NOTES F11Install city furnished TYPE 90 Controller equipment package including TYPE "R" Cabinet, Solo Pro Detection, and appurtenant equipment (See Special Provisions). Controller cabinet and foundation to be installed per City Standard Drawing 4001. Contractor shall furnish and install any additional electronic equipment required to provide the desired signal operation as shown on the plan. F2 -]Furnish and install TYPE III -BF Service Equipment Enclosure per City of Fontana and Southern California Edison Company requirements (See Special Provisions). F3 -]Install city furnished Solo Pro camera and bracket per City Standard Plan No. 4004. Furnish and install necessary cables and make necessary connections in the controller cabinet per manufacturer's specifications. Controller cabinet to be modified for video per City of Fontana Standards (See Special Provisions). ® Install city furnished unidirectional, single channel OPTICOM Detector (Model 711 or equal) per detail this sheet and as directed by the Engineer. (See Special Provisions). F5-] Furnish and install R73-3 sign per CALTRANS Standard ES -7N, Detail U. [-6] Furnish and install R3-4 sign per CALTRANS Standard ES -7N, Detail U. Curb/Ber or edge or U w Typical signal placement unless dimensions noted on plans. NOTE: For "X& B" dimensions refer to POLE SCHEDULE, or as directed by the Engineer. Negative "A" refer to a distance departing intersection away from BC or EC. SIGNAL STANDARD PLACEMENT DIMENSIONS AND EQUIPMENT LOCATIONS A w z 0 8 0 12' 2 CG---------------------- POLE 3 F4 SIGNAL MOUNTING .............. ..`•:iii?l'� I 1 1 1 1 1 1 1 1 1 1 I I 1 1 \vl�~\Llll I 1 1 m 1 1 I I 1 1 1 1 16' POLE AND EQUIPMENT SCHEDULE POLE SIGNAL STANDARD PLACEMENT DIMENSIONS SIGNAL MOUNTING PED PUSH BUTTONS HPSV LUMINAIRE NON -ILLUMINATED STREET NAME SIGN N0. TYPE POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM "A" "B" MAST ARM VEHICLE "F'' POLE VEHICLE POLE EDESTR Qs ARROW QUAD A 26A-4-100 35' 45' 15' 12' 4' 2 -MAS 18' SV -1-T SP -1-T 8 �— E 250W Knox Ave 11. Any existing traffic signals and lighting shall remain in operation 3. All pull boxes shall be No. 6 and conduit shall be 2" rigid metal until replaced with new construction. unless otherwise shown. 12. The Contractor shall furnish all equipment, materials, and hardware 4. - C 19A-4-100 35' 30' 15' 12' 4' MAS - SV -1-T SP -1-T 6 f S 250W So Highland Ave D 1-A 10' - - 12' 4' - - TV -2-T SP -1-T 2 —� W - - E 26A-5-100 35' 45' 15' 10' 4' 2 -MAS 18' SV- 1-T SP -1-T 2 -� W 250W Knox Ave F 1-A 10' - - 10' 4' - - TV -2-T SP -1-T 4 N - - G 19A-4-100 35' 25' 12' 10' 6' MAS - SV- 1-T SP -1-T 4 �— N 250W So Highland Ave H 1-A 10' - - 10' 4' - - TV -2-T SP -1-T 1131 E - - t 9r SP ---------------------------------------- 1 6; 3 7 1 1 1 Ir/► 1 / _------'------------------------ �----------------------------------------------------------------------------------------------------------w- --�- ----• L------------------------------------- - O --------------------------------------------------------------------------------------------------------- --�/[ ----- I ' I V� Y.l , , I 150' � , 1 E11-7�7 � w -- I 1 ' - w 1 / - � i � - II I / /4 04 NEW CURBED MEDIAN 1 / ; 2#8 G.F.C.I.) o cit fit5 219 C )2#6 SERVICE) ' 1 2 3 / / c0 / - w 1 1 I 1 :::: 1 1 :'":: .................................................................................................................................................................................................. ......................... 41 06 Q R W 1 '�•'• 2" C &PULL ROPE FOR ' 9 SCE CONDUCTORS EX. C & G ...I OF 8 A SCE P.P. (SERVICE POINT) 1 . ...... 2" Co 2#10 (LIGHTING) 2 %i GENERAL NOTES 1. Traffic signal, signing and striping, and li hting shall conform to 16' Legends for OVERHEAD STREET NAME SIGNS Location: South Highland Ave. & Knox Ave. Ave MAYA South Highland 5700 North East Corner Knox Ave ,µ 6500 North West Corner South Highland 5soo South West Corner Knox Ave 6600 Soutn East Corner EMERGENCY VEHICLE 'ION DETECTOR MAST ARM 3M OPTICOM MODEL 711 E.V.P. MOUNTING DETAIL N.T.S these plans, the Special Provisions, the City of Fontana Standard 8. The controller cabinet shall not be subject to water from sprinklers. 1 of Details, and the State of California Standard Specifications Section 86 (dated May 2006) and Standard Plans (dated May 2006), the The Contractor shall modify sprinkler systems if necessary. California Manual on Uniform Traffic Control Devices (MUTCD) for 9. The alignment of interconnect ducts shall be as straight aspossible. streets and highways dated September 2006. However, when changed in alignment are necessary, sweeps shall have minimum radius of 3 feet. 2. Location of all underground facilities are approximate. The Contractor shall pothole to determine the exact location and verify 10. All vehicle indications shall be 12" and have L.E.D. signal modules. all conditions on the job site. Hand dig foundations until clear of All pedestrian heads shall have L.E.D. pedestrian modules and utilize any obstructions. Phone Underground Service Alert (800) 226-2700, pedestrian countdown timers per the Special Provisions. two working days before digging. 11. Any existing traffic signals and lighting shall remain in operation 3. All pull boxes shall be No. 6 and conduit shall be 2" rigid metal until replaced with new construction. unless otherwise shown. 12. The Contractor shall furnish all equipment, materials, and hardware 4. The Contractor shall make application for electrical service and to construct the traffic signal and lighting as shown on the plans scheduling with Southern California Edison Company four weeks in except as noted city furnished or listed as city provided in the advance of need. Special Provisions. 5. The Contractor shall obtain approval from the Engineer for exact 13. The Contractor shall refer the the City Traffic Engineer in the event equipment locations prior to final placement. See detail on this of a conflict or potential conflict with these plans and/or sheet. specifications for this project. 6. All required construction permits shall be obtained from the City 14. Where traffic signal street crossing conduits are not installed using of Fontana Engineering Division prior to commencement of work. the boring method, trench repairs shall be per detail this sheet, and Special Provisions, Section E. 7. The Contractor shall relocate and/or replace landscaping, sprinklers, and sidewalk affected by the construction to the satisfaction of 15. Traffic sign size shall be for conventional roadways unless otherwise the Engineer. shown on the plans. of