HomeMy WebLinkAbout4899-11.
2.
3,
4.
5.
6.
7.
,M
0
2 pp
L3
H
W ~
> W
0 W
PQ Z
Q H
J
W
W =
Q
Uj
>^ 11T
JNA
I- I,�
III X
01
W ��' IX
~ w IIrlI -
,! I IT i
CITRUS
EX. R/W
AVENUE
�.�
------------------------------- -- ------------------------------------------------------------- ---------------------
i
,
- -- ---- -- - - - - - -- -- - -- ----- - -- - --'~— �— --- EX, AC BERM
/i—n /i—� /1—� /i= /�� /1�� 4L��
X, AC BERM
A _ _
-_— T 7
—�
G G G G' I G G �G= G G G G G GA
G G G G G G G G G G G G G! G G G G G C G G G G G G G G G G G G G G- -\\ G G G G G G G
I -
r�
_ _ _�.L - - --- - -- - - --- - -- - - - ,.- - -
_ \ _ �..,:�ma-m4--.
—� „�—� •�----a atv-- amr—-�— __ -- T — T — T m.. --mom ma. -T
m4—G.7L—mi—m4--m1.—-— w.—m4 mir—ml�m4—(D�iII7�—mt�._n7V
t - .- -R-BP; C- &G
_1_ ,. �/ PROP. SIDEWALK EX. R/W---/PROP, R/W PROP, SIDEWALK EX, R/W
���
II I ±110 LF,
�I
Q
^ a� I I J . ,
X 0� U I ry
W
CL
N
t� w W
�7 CITRUS
EX. R/W
- (E X , A C BERM 11--- - �l--- -- _
TRAFFIC SIGNAL I NTERCONNECT/COMMUNI CATION GENERAL NOTES
TRAFFIC SIGNAL INTERCONNECT SHALL CONFORM TO THESE PLANS, THE
STATE OF CALIFORNIA STANDARD SPECIFICATI❑NS SECTION 86 AND STANDARD
PLANS (DATED JULY 2006), AND THE SPECIAL PR❑VISIONS,
ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY
OF FONTANA ENGINEERING DIVISION PRI❑R TO C❑MMENCENT OF WORK.
THE CONTRACTOR SHALL REPAIR ALL DAMAGED LANDSCAPING AND IRRIGATI❑N
TO THE SATISFACTION OF THE ENGINEER,
CONDUIT SHALL NOT BE INSTALLED DIRECTLY OVER ANY UTILITY LINE
(PARALLEL WITH THE LINE), UTILITY LINE CROSSINGS ARE ALLOWED.
CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY ENGINEER FOR EXACT
EQUIPMENT L❑CATIONS PRI❑R TO FINAL PLACEMENT,
PULL BOXES AND SPLICE VAULTS SHALL NOT BE LOCATED IN DRIVEWAYS OR
OTHER LOCATIONS WHICH MAY INTERFERE WITH THE MOVEMENT OF PEOPLE
OR VEHICLES, PULL BOX L❑CATIONS SHALL BE ADJUSTED AS NEEDED,
ALL PULL BOXES SHALL BE No. 6E AND CONDUIT SHALL BE 2" GALVANIZED RIGID
METAL UNLESS OTHERWISE SHOWN. ALL SPLICE VAULTS SHALL BE TYPE P48
48.5"x30.5"x30" DEEP (INSIDE), FIBERGLASS, HAVE LOCKING LIDS, AND BE
LABELED "COMMUNICATIONS". PULL BOXES AND SPLICE VAULTS SHALL BE
INSTALLED IN ACCORDANCE WITH THE PROJECT DETAILS FOR PULL BOX AND
SPLICE VAULT INSTALLATION.
WHERE CONDUIT IS INSTALLED AND DISTURBS EXISTING STRIPING,
CONTRACTOR SHALL ARRANGE AND PAY FOR STRIPING, SEE SPECIAL
PR❑VISI❑NS FOR CONTRACTOR RESPONSIBILITY FOR TEMPORARY PAVEMENT
MARKINGS,
9. ALL PCC SIDEWALK DAMAGED BY THE CONTRACTORS OPERATIONS SHALL BE
SAWCUT, REMOVED, AND REPLACED TO EXISTING EXPANSION/SCRIBE JOINTS,
10. LOCATI❑N OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE, THE
CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND
VERIFY ALL CONDITIONS ON THE JOB SITE, HAND DIG UNTIL CLEAR OF
OBSTRUCTIONS, PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600,
TWO (2) WORKING DAYS BEFORE DIGGING, THE ENGINEER SHALL BE NOTIFIED
OF ANY DISCREPENCIES OR CONFLICTS PRIOR TO DOING STREET WORK.
11. THE CONTRACTOR SHALL LOCATE, PROTECT, SHORE, BRACE, SUPPORT, AND
MAINTAIN ALL EXISTING FACILITIES INCLUDING GAS, WATER, IRRIGATION,
SEWER, POWER, STREET LIGHTS, TELEPHONE AND OTHER CONSTRUCTI❑N
WHICH MAY BE UNCOVERED OR OTHERWISE AFFECTED BY THE WORK.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATI❑N
OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL
NOTIFY UTILITIES FORTY-EIGHT (48) HOURS IN ADVANCE OF ANY
CONSTRUCTION.
12. ALL TRAFFIC CONTROL DEVICES SHALL BE IN PLACE BEFORE WORK IS
STARTED. TRAFFIC CONTROL, WORK ZONES, AND LANE CLOSURES SHALL BE
COMPLETELY DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY
BARRIERS TO EXCLUDE VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR
SHALL FOLLOW THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL
DEVICES (CALIFORNIA MUTCD DATED JANUARY, 2010) FOR CONSTRUCTION AND
MAINTENANCE WORK ZONES, CALTRANS STANDARD SPECIFICATI❑NS, AND
STANDARD PLANS, DATED 2006, EXACT LOCATI❑N OF ALL TRAFFIC CONTROL
TO BE DETERMINED BY THE ENGINEER AND ADDITIONAL WARNING AND/OR
CONSTRUCTION SIGNING MAY BE REQUIRED. DEVICES NO LONGER REQUIRED
SHALL BE REMOVED AS SOON AS POSSIBLE, CONTRACTOR SHALL PR❑VIDE
TRAFFIC CONTROL PLANS TO ENGINEER FOR APPROVAL PRIOR TO
CONSTRUCTI❑N,
DIC.�LE �aT
TOLL FREE 'qqmmw1w' 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
2 1 ±540 LF,
CD
0
AVENUE
1
2 1 ±160 LF,
EX. R/W
-------- ---------
T EX. AC BERM
LU
13, PEDESTRIAN TRAFFIC MUST BE MAINTAINED AT ALL TIMES, PEDESTRIANS MAY
BE RELOCATED ONTO PRIVATE PROPERTY WITH OWNERS PERMISSION ONLY,
14. NO EQUIPMENT OR MATERIALS SHALL BE STORED ON SIDEWALK AT ANY TIME.
15, A 12" VERTICAL SEPARATI❑N BETWEEN NEW CONDUITS AND OTHER UTILITIES
SHALL BE MAINTAINED AT CROSSINGS, A 3' MIN, HORIZONTAL SEPARATI❑N
BETWEEN NEW CONDUITS AND POWER AND WATER UTILITIES THAT RUN
PARALLEL SHALL BE MAINTAINED, A 3' (EXCEPT WHERE NOTED) MINIMUM
SEPARATION BETWEEN CONDUIT AND SANITARY SEWER AND STORM DRAINS
THAT RUN PARALLEL SHALL BE MAINTAINED, UNLESS OTHERWISE APPROVED
BY THE ENGINEER. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 3'
CLEARANCE FOR ALL OTHER FACILITIES.
16. TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS MAY NOT BE SHOWN.
CONTRACTOR SHALL LOCATE ALL TRAFFIC SIGNAL CIRCUITS AND
INTERCONNECT CONDUITS PRIOR TO ANY TRENCHING OR B❑RING, ALL
TRAFFIC SIGNAL AND INTERCONNECT CONDUITS SHALL BE MAINTAINED AND
PROTECTED,
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING RECORD
DRAWINGS FOR ALL WORK THROUGHOUT THE COURSE OF CONSTRUCTION,
18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL
EXISTING SURVEY MONUMENTS OR MARKERS DURING CONSTRUCTION.
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
.� No. C 40964
EV. 3-31-13
\ CIVIL /
_G G
±100 L.F.
SCALE: 1:40
0
U') N
-F-
0 W
N 0
Q N
F- I-
W
W W
Z =
= W
LIIj
V)
Q
TRAFFIC SIGNAL INTERCONNECT/COMMUNICATION CONSTRUCTION NOTES
1� FURNISH AND INSTALL TYPE P48 (SEE GENERAL NOTE #7) SPLICE BOX
FURNISH & INSTALL 6-1,5' SCHEDULE 40 HDPE CONDUITS PER DETAIL °C', THE
CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN,
FURNISH AND INSTALL ONE PULL ROPE IN EACH CONDUIT FOR FUTURE CABLE. CONDUIT
SWEEPS SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS, FURNISH AND INSTALL
96 STRAND S,M,F.❑, CABLE IN THE BLUE CONDUIT
a FURNISH AND INSTALL 2° CONDUIT, FURNISH AND INSTALL 96 STRAND S,M,F,O. CABLE
SEE DRAWING NO. 4873 SHEET 4/5 & DRAWING NO. 4873 SHEET 5/5 FOR CONDUIT
AND SPLICE BOX INSTALLATION DETAILS
Prepared Under The Supervision Of :
Date :
Felipe U. Molinos, R.C.E. 40964
CIN OF FONTANA, CALIFORNIA
FIBER OPTIC INTERCONNECT PLAN
°R""" BY: btiA=
DT CITRUS AVENUE 1.40
DIED 9YDT ST 10+50. 0—STA. 28+50.00 DAM 4.19.11
CHECKED BY: AOP BY• / DRAWING NO.:,me 1
MP '
rMY FN[;INFFR R_C_F 571152 4899 2