Loading...
HomeMy WebLinkAbout4899-11. 2. 3, 4. 5. 6. 7. ,M 0 2 pp L3 H W ~ > W 0 W PQ Z Q H J W W = Q Uj >^ 11T JNA I- I,� III X 01 W ��' IX ~ w IIrlI - ,! I IT i CITRUS EX. R/W AVENUE �.� ------------------------------- -- ------------------------------------------------------------- --------------------- i , - -- ---- -- - - - - - -- -- - -- ----- - -- - --'~— �— --- EX, AC BERM /i—n /i—� /1—� /i= /�� /1�� 4L�� X, AC BERM A _ _ -_— T 7 —� G G G G' I G G �G= G G G G G GA G G G G G G G G G G G G G! G G G G G C G G G G G G G G G G G G G G- -\\ G G G G G G G I - r� _ _ _�.L - - --- - -- - - --- - -- - - - ,.- - - _ \ _ �..,:�ma-m4--. —� „�—� •�----a atv-- amr—-�— __ -- T — T — T m.. --mom ma. -T m4—G.7L—mi—m4--m1.—-— w.—m4 mir—ml�m4—(D�iII7�—mt�._n7V t - .- -R-BP; C- &G _1_ ,. �/ PROP. SIDEWALK EX. R/W---/PROP, R/W PROP, SIDEWALK EX, R/W ��� II I ±110 LF, �I Q ^ a� I I J . , X 0� U I ry W CL N t� w W �7 CITRUS EX. R/W - (E X , A C BERM 11--- - �l--- -- _ TRAFFIC SIGNAL I NTERCONNECT/COMMUNI CATION GENERAL NOTES TRAFFIC SIGNAL INTERCONNECT SHALL CONFORM TO THESE PLANS, THE STATE OF CALIFORNIA STANDARD SPECIFICATI❑NS SECTION 86 AND STANDARD PLANS (DATED JULY 2006), AND THE SPECIAL PR❑VISIONS, ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRI❑R TO C❑MMENCENT OF WORK. THE CONTRACTOR SHALL REPAIR ALL DAMAGED LANDSCAPING AND IRRIGATI❑N TO THE SATISFACTION OF THE ENGINEER, CONDUIT SHALL NOT BE INSTALLED DIRECTLY OVER ANY UTILITY LINE (PARALLEL WITH THE LINE), UTILITY LINE CROSSINGS ARE ALLOWED. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY ENGINEER FOR EXACT EQUIPMENT L❑CATIONS PRI❑R TO FINAL PLACEMENT, PULL BOXES AND SPLICE VAULTS SHALL NOT BE LOCATED IN DRIVEWAYS OR OTHER LOCATIONS WHICH MAY INTERFERE WITH THE MOVEMENT OF PEOPLE OR VEHICLES, PULL BOX L❑CATIONS SHALL BE ADJUSTED AS NEEDED, ALL PULL BOXES SHALL BE No. 6E AND CONDUIT SHALL BE 2" GALVANIZED RIGID METAL UNLESS OTHERWISE SHOWN. ALL SPLICE VAULTS SHALL BE TYPE P48 48.5"x30.5"x30" DEEP (INSIDE), FIBERGLASS, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS". PULL BOXES AND SPLICE VAULTS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT DETAILS FOR PULL BOX AND SPLICE VAULT INSTALLATION. WHERE CONDUIT IS INSTALLED AND DISTURBS EXISTING STRIPING, CONTRACTOR SHALL ARRANGE AND PAY FOR STRIPING, SEE SPECIAL PR❑VISI❑NS FOR CONTRACTOR RESPONSIBILITY FOR TEMPORARY PAVEMENT MARKINGS, 9. ALL PCC SIDEWALK DAMAGED BY THE CONTRACTORS OPERATIONS SHALL BE SAWCUT, REMOVED, AND REPLACED TO EXISTING EXPANSION/SCRIBE JOINTS, 10. LOCATI❑N OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE, THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE, HAND DIG UNTIL CLEAR OF OBSTRUCTIONS, PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING, THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPENCIES OR CONFLICTS PRIOR TO DOING STREET WORK. 11. THE CONTRACTOR SHALL LOCATE, PROTECT, SHORE, BRACE, SUPPORT, AND MAINTAIN ALL EXISTING FACILITIES INCLUDING GAS, WATER, IRRIGATION, SEWER, POWER, STREET LIGHTS, TELEPHONE AND OTHER CONSTRUCTI❑N WHICH MAY BE UNCOVERED OR OTHERWISE AFFECTED BY THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATI❑N OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITIES FORTY-EIGHT (48) HOURS IN ADVANCE OF ANY CONSTRUCTION. 12. ALL TRAFFIC CONTROL DEVICES SHALL BE IN PLACE BEFORE WORK IS STARTED. TRAFFIC CONTROL, WORK ZONES, AND LANE CLOSURES SHALL BE COMPLETELY DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR SHALL FOLLOW THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA MUTCD DATED JANUARY, 2010) FOR CONSTRUCTION AND MAINTENANCE WORK ZONES, CALTRANS STANDARD SPECIFICATI❑NS, AND STANDARD PLANS, DATED 2006, EXACT LOCATI❑N OF ALL TRAFFIC CONTROL TO BE DETERMINED BY THE ENGINEER AND ADDITIONAL WARNING AND/OR CONSTRUCTION SIGNING MAY BE REQUIRED. DEVICES NO LONGER REQUIRED SHALL BE REMOVED AS SOON AS POSSIBLE, CONTRACTOR SHALL PR❑VIDE TRAFFIC CONTROL PLANS TO ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTI❑N, DIC.�LE �aT TOLL FREE 'qqmmw1w' 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 2 1 ±540 LF, CD 0 AVENUE 1 2 1 ±160 LF, EX. R/W -------- --------- T EX. AC BERM LU 13, PEDESTRIAN TRAFFIC MUST BE MAINTAINED AT ALL TIMES, PEDESTRIANS MAY BE RELOCATED ONTO PRIVATE PROPERTY WITH OWNERS PERMISSION ONLY, 14. NO EQUIPMENT OR MATERIALS SHALL BE STORED ON SIDEWALK AT ANY TIME. 15, A 12" VERTICAL SEPARATI❑N BETWEEN NEW CONDUITS AND OTHER UTILITIES SHALL BE MAINTAINED AT CROSSINGS, A 3' MIN, HORIZONTAL SEPARATI❑N BETWEEN NEW CONDUITS AND POWER AND WATER UTILITIES THAT RUN PARALLEL SHALL BE MAINTAINED, A 3' (EXCEPT WHERE NOTED) MINIMUM SEPARATION BETWEEN CONDUIT AND SANITARY SEWER AND STORM DRAINS THAT RUN PARALLEL SHALL BE MAINTAINED, UNLESS OTHERWISE APPROVED BY THE ENGINEER. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 3' CLEARANCE FOR ALL OTHER FACILITIES. 16. TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS MAY NOT BE SHOWN. CONTRACTOR SHALL LOCATE ALL TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS PRIOR TO ANY TRENCHING OR B❑RING, ALL TRAFFIC SIGNAL AND INTERCONNECT CONDUITS SHALL BE MAINTAINED AND PROTECTED, 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING RECORD DRAWINGS FOR ALL WORK THROUGHOUT THE COURSE OF CONSTRUCTION, 18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURVEY MONUMENTS OR MARKERS DURING CONSTRUCTION. SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. .� No. C 40964 EV. 3-31-13 \ CIVIL / _G G ±100 L.F. SCALE: 1:40 0 U') N -F- 0 W N 0 Q N F- I- W W W Z = = W LIIj V) Q TRAFFIC SIGNAL INTERCONNECT/COMMUNICATION CONSTRUCTION NOTES 1� FURNISH AND INSTALL TYPE P48 (SEE GENERAL NOTE #7) SPLICE BOX FURNISH & INSTALL 6-1,5' SCHEDULE 40 HDPE CONDUITS PER DETAIL °C', THE CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN, FURNISH AND INSTALL ONE PULL ROPE IN EACH CONDUIT FOR FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS, FURNISH AND INSTALL 96 STRAND S,M,F.❑, CABLE IN THE BLUE CONDUIT a FURNISH AND INSTALL 2° CONDUIT, FURNISH AND INSTALL 96 STRAND S,M,F,O. CABLE SEE DRAWING NO. 4873 SHEET 4/5 & DRAWING NO. 4873 SHEET 5/5 FOR CONDUIT AND SPLICE BOX INSTALLATION DETAILS Prepared Under The Supervision Of : Date : Felipe U. Molinos, R.C.E. 40964 CIN OF FONTANA, CALIFORNIA FIBER OPTIC INTERCONNECT PLAN °R""" BY: btiA= DT CITRUS AVENUE 1.40 DIED 9YDT ST 10+50. 0—STA. 28+50.00 DAM 4.19.11 CHECKED BY: AOP BY• / DRAWING NO.:,me 1 MP ' rMY FN[;INFFR R_C_F 571152 4899 2