Loading...
HomeMy WebLinkAbout4859-1CITYOFFONTANA SANTA ANA A VENUE, STREET & S TORM DRA IN IMPR 0 VEMEN T PLAN Cl TR US A VE- NUE TO C YPRESS A VENUE STORMDIMIN SHEET6 ----A e. lj� ��y�j ����.�.'j � ��`y.'`<�y {(���Jj Q�,y�� ��q-y[�,.�{�!S�] [yp��'�j t((,i�� f,�,�T � fir -J 'g`' ® m m ®m' M0 a ® G ® ® Y -ti ® B LLl Gf'� ® m O M M M I-�ti M [a m o m mom m ® ® L'�id- O M M EIM 0 © 0- Eau ® � ® � � � ^®` � � � � � ® ® � ® � ® o m 0 ® ® m 0 ® M O ® M O M � � � � ® � � � ® �i .YY� • ® I II 0 4 0255-0112 f N 0255-011-30 0255-01129 0255-01119 ' 0255-01118 0255-01115 025MfI-M 0255-011-13 ����,�_ - ------,-------------^------------------------------ ------------� - --------,---------,- -- _ _ --- --- �,- ---_ - EYL5 71 J -- -- -- -- ------ I - 708 AMA 710 J 696 697 699 inn �n�T W N -{' --------- - -- - -----------------------_---------------------------------------- --- __- pl ------------b b En 0255-071-04^ 0255-071351 ' 0255-071-52' 0255-071 0255-07108 0255-071-39 _I 0255-071-01 0255-071-02 0255-071-0 , , I I J SHEET3 SHEET4 POTHOLE VERIFICAT/ON THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WAS OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ADDITIONAL UNDERGROUND FACILITIES MAY EXIST, OR THE LOCATION OF FACILITIES MAY DIFFER FROM THE LOCATIONS SHOWN ON THE PLANS. THE CONTRACTOR SHALL AT HIS OWN EXPENSE DETERMINE THE EXACT LOCATION OF ALL SUCH UNDERGROUND UTILITIES PRIOR TO DOING ANY WORK OR TAKING ANY ACTION THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR CONTINUOUS OPERATIONS UPON LEARNING OF THE EXISTENCE AND LOCATION OF ANY UNDERGROUND FACILITIES NOT SHOWN ACCURA7FL Y ON. THESE PLANS OR NOT PROPERL Y MARKED BY THE UTILITY OWNER. THE CONT24CTOR SHALL IMMEDIATELY NOTIFY THE UTILITY OWNER AND THE ENGINEER BY TELEPHONE AND IN WRITINGU, NOT/CE TO CONTRACTOR THE EX/S7FNCE AND LOCA77ON OF ANY UNDERGROUND U77LITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY SEARCH OF ALL AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY A CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTTL/TY LINES SHOWN OR NOT SHOWN ON THESE PLANS. CONSTRUCTION CONTRACTOR AGREES THHAT IN ACCORDANCE WITH GENERALL Y ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFELY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CON77N000SL Y AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR Fl/RTHER AGREES TO DEFEND, INDEMNIFY AND HOLO C17Y OF FONTANA HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTION LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. ALL CONTRACTORS AND SUB CONTRACTORS SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE US DEPARTMENT OF LABOR AND WITH THE STA7F OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS "CONSIRUCTTON SAFETY ORDERS". THE CITY OF FONTANA SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR OR SUBCONTRACTORS COMPLIANCE WITH SAID REGULATIONS AND ORDERS. UNAUTHORIZED CHANGES & USES: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY 7HE ENGINEER PREPARING THESE PLANS. BASIS OF BEARING CENTERLINE OF SLOVER AVENUE BE7WEEN SAN BERNARDINO CO. SURV. GPS CON7M MONUMENT NOS 21158 & 21219, BEING THE IN7ERSEC770N OF CITRUS AVENUE & CYPRESS AVENUE RESPEC77-ULL Y, BEING: N89'30'14 "E. BENCHMARK NO. 291 PERPETUA TED: TRANSFERRED ELEVATION FROM CITY OF FONTANA BM 291, A RR SPIKE IN PP NO. 586962H, LOCATED AT THE NE CORNER OF OLEANDER AVE & SANTA ANA AVE, ELEV. 1047.36, TO THE TOP A "PK" NAIL & BRASS WASHER, STAMPED "CITY OF FONTANA BM", SET ON THE TOP OF CURB 1 ' NORTH OF THE NORTHERLY END OF THE NE CURB RETURN AT OLEANDER AVE & SANTA ANA AVE ELEVA770N.• 1044.75 DIC.�LE TOLL FREE —800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT SANTA ANA AVENUE INDEX MA P SCALE: 1 .100, CONSTRUCTIONNOTES QUANT/T/ES Q1 CONSTRUCT 6-1/2" MIN. A.C. PAVEMENT OVER 12" MIN. OF 95.E COMPACTED NATIVE 4, 031 TONS 20 CONSTRUCT COMMERCIAL CONCRETE DRIVEWAY PER CITY OF FONTANA STD. N0. 1002 (WIDTH PER PLAN) 2 EA 03 SAW CUT AND REMOVE EXISTING A. C. PAVEMENT 71,224 SF ® CONSTRUCT 8" AC DIKE PER CITY OF FONTANA STD. DETAIL N0. 1007 200 LF 50 CONSTRUCT 8" CURB AND GUTTER PER CITY OF FONTANA STD. N0. 1000 1, 439 LF © CONSTRUCT 4" PCC SIDEWALK PER CITY OF FONTANA STD. N0. 1006 (W-6) 11,705 SF Q7 CONSTRUCT RESIDENTIAL CONCRETE DRIVEWAY PER CITY OF FONTANA STD. N0. 1002 (WIDTH PER PLAN) 8 EA ® INSTALL STREET LIGHT 16,000 LUMEN PER C17Y OF FONTANA STD N0. 404 (BY OTHERS) 6 EA 90 RELOCATE EXIS17NG POWER POLES (BY OTHERS) 9 EA 10 ADVUST EXIS7ING WATER METER TO GRADE (BY OTHERS) 6 EA 1© ADJUST WATER VAL VE TO GRADE PER CITY OF FONTANA S7T9 DETAIL N0. 6000 8 EA Q2 SIGN TO BE REMOVED, REFER TO SIGNING AND STRIPING PLAN FOR DETAILS 4 EA © REMOVE & CONSTRUCT NW CHAIN LINK FENCE AND GATES ® NEW RIGHT OF WAY LINE 893 LF ® RELOCATE EXISTING MAILBOX 4 EA © REMOVE EXIS17NG TREES AND BUSHES WITHIN PROPOSED PUBLIC RIGHT OF WAY 35 EA © PROTECT IN PLACE -- EA © INSTALL 3" THICK MULCH IN PARKWAY 11, 083 SF ® CONSTRUCT CATCH BASIN PER CITY OF FONTANA STD. N0. 3004 (W & V PER PLAN) 1 EA 19 CONSTRUCT LOCAL DEPRESSION PER CITY OF FONTANA SID. NO. 3003 CASE C 1 EA ® REMOVE EXISTTNG 18" CMP PIPE AND HEADWALLS 1 LS © CONSTRUCT MANHOLE PER CITY OF FONTANA STD NO. 3011 1 EA © CONSTRUCT MANHOLE PER CITY OF FONTANA STD NO. 3013 2 EA © CONSTRUCT 30 R.C.P. PIPE "D" LOAD PER PLAN 759 LF (8 CONSTRUCT 24 " R. C. P. PIPE "D" LOAD PER PLAN 29 LF © CONSTRUCT 18 R. C. P. PIPE "0" LOAD PER PLAN 36 LF REMOVE EXIST 30" R.C.P. PIPE .18 LF © CONSTRUCT PIPE CLOSURE PER DETAIL ON SHEET NO. 2 1 EA ® INSTALL STREET LIGHT CONDUITS PER EDISON PLAN 1 LS ©g CONSTRUCT 15 x21 " CMP ARCH PIPE 13 LF ® CONSTRUCT PIPE HEADWALL PER CAL TRANS STANDARD D89A, SEE SHT 2. 1 EA © CONSTRUCT CONCRETE COLLAR PER CITY OF FONTANA STD N0. 3022 1 EA © GRADE AND CONSTRUCT 4" THICK PCC OVER COMPACTED NA17VE BEHIND WALK OR DRIVEWAY (LIMITS PER PLAN) 2 EA © GRADE ANO CONSTRUCT 4" THICK AC OVER COMPACTED NATIVE BEHIND WALK OR DRIVEWAY (LIMITS PER PLAN) 6 EA ® MODIFY LANDSCAPE & IRRIGATION LINES AS NEEDED 1 LS © ADJUST EXISTING FENCE AND GALE PER FINAL GRADE ELEVATION 283 LF ® CONSTRUCT 6" A. C. CURB PER CITY OF FONTANA SID. NO. 1006 369 LF © REMOVE AND CONSTRUCT GUTTER AS SHOWN ON SHEET 5 40 LF ® CONSTRUCT 3" A. C. SIDEWALK PER C17Y OF FONTANA STD DETAIL N0. 1007 (W-49 1, 484 SF ® CONS7UCT CONCRETE WALL PER VALL DETAIL " ON SHEET 3 410 LF REV. REVISION DESCRIPTION DATE ENGR. CITY DATE I I 025542118 02502117 1 1_ _ 11 Z � Q 711 716 _1 717 0255-081-53 SHEET 5 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. UT/L /TYNOT/F/CAT/ONL /ST AT&T DISTRIBUTION 1265 N VAN BUREN ST 1180 ANAHEIM, CA 92807 (714) 666-5401 FONTANA WATER COMPANY 11142 GARVEY AVE EL MON7F, CA 91733 (626) 448-6183 LEVEL 3 COMMUNICATIONS 1025 ELDORADO BLVD BLDG 33A-522 BROOMF/ELD, CO 80021 (720) 888-6482 TIME WARNER CABLE 1500 AUTO CENTER DR ONTARIO, CA 91761 (909)975-3343 LEGEND KINDER MORGAN ENERGY PARTNERS 1100 TOWN & COUNTRY RD ORANGE, CA 92868 (714) 560-4409 SC GAS 1981 W LUGONA AVE REDLANDS, CA 92374 (909) 335-7755 UTIVOUEST FOR SCE DIST EDISON DISTRIBUTION 7.951 REDWOOD AVE FONTANA, CA 92336 (909) 357-6221 SEWER CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-6632 CONSTRUCT NEW AC PAVEMENT . ra. • � �•� ' PROP SIDEWALK EXIST SIOENVALK GAS—EXIS77NG GAS UNE W EXISTING WA7FR LINE S EXISTING SEWER LINE s0 EXISTING SO UNE PROPOSED WALL FLOW DIREC77ON FS FINISH SURFACE TC TOP OF CURB EG EXIS77NG GROUND EP EDGE OF PAVEMENT ES EXIS77NG SURFACE O Q�OFESSI0�9 �v 20 Z m No. 40964 \j. CIVIC F OF CAUF� Prepared Under The Supervision Of : I-10FREEWAY SLOI/ER VE SANTA ANA AVE p z v v o v JURUPAAVE VKNNffY �uw NTS SHEETINDEX 1 TITLE SHEET — INDEX MAP, VICINITY MAP, GENERAL NOTES, CONSTRUCTION NOTES, & OVAN7777ES 2 GENERAL NOTES TYPICAL SECTIONS & DETAILS 3 SANTA ANA AVE STA 694*86.97 — STA 701 *50.00 4 SANTA ANA AVE STA 701 *50.00 — STA 709+00.00 5 SANTA ANA AVE STA 709*00.00 — STA 716+92.19 6 STORM DRAIN LINE A ICITY OF FONTANA, CALIFORNIA I STREET IMPROVEMENT PLAN DRAWN BY: VA DESIGNED BY: VA/SN DateECKED BY: CH FEUPE U. MOUNOS R.C.E. 40964 SN SANTA ANA AVENUE TITLE SHEET INDEX MAP, VIQ, LAITY MAP, APPROVED ,BY: 01 04`x., f1 DAT .C.E. 51152 SCALE: AS SHOWN DATE: 12/06/10 DRAWING NO.: '� 4859 6 SI\DESIGN SECTI❑N\CIP IMPROVEMENTS\SANTA ANA - CITRUS TO CYPRESS\SHEET l,dwg Mar 14, 11 - 530pm