HomeMy WebLinkAbout4821-140
EXISTING IIS
R1 -1+R1-4 I
w
EXIST R/W�,i
EXIST C���
100' N 00°14'549'E
7:7T,.* EP
EXISTING
R1-1 +R1-4
� I
w I
I
I
EXIST EP
EX R
112'
30'
I
i
W i
Z I
W i
i
a I
a r
Z � M
a
a
EP
LO
z
N I-II
�I
I IIS
N
I I x
LLI
� II
Lon
II i
I II
ISI
I_1
1
EXIST ling 32'
C & G II
NORTH II
GRAPHIC SCALE
0 20 40 80
( IN FEET )
1 inch = 40 ft.
C/L INT.
10+00.00 SANTA ANA AVE.
=10+00.00 POPLAR AVE. 13+10 JOIN
I EX STRIPING I I Ln .3 i RinivV
� END SANDBLAST END SANDBLAST
� EXISTING R 1-1 +R 1-4 21 POPLAR AVENUE R3-7 EXIST W3-1
-- -- -- -- -- -- -- ---- -- -- -- -- -- -- -- - -- -- -- -
\ 9 7'�
_ \
EXIST C/G�
7 EXIST C/G-�
0 1 1 100' N 3
w N
M
13- 14- 15- 16-
0 6 11N
C-4 2 1
4 1O N 1
0 0
N PROPOSED C/G�_ 04
7 i-
- -- PROPOSED R/W -- -- -- -- -- -- -- -- -\ -_/
DEW
EXISTING R1-1 +R1-4
21 W9-1 T
PROTECT IN PLACE
i DURING CONSTRUCTION
20+50 JOIN
AHEAD �
5
21 W3-1
mp
30' � EXIST
R/W
Of
m
Q
00
0
0
a-
0
a.
12'
I
I
160
RELOCATE R1-1 +R1-4
UPON COMPLETION OF
CONSTRUCTION
BENCHMARK
#2ss
RAILROAD SPIKE IN P.P. N0. 71883 AT THE N.E. CORNER
OF POPLAR AVENUE AND SANTA ANA AVENUE.
ELEV. - 1019.83
0
O
0 +
C4
w
> W
m Z
a J
w
vwi =
Q
10847 POPLAR AVENUE
(NoSTRIPING CONSTRUCTION NOTES
LO
+ _ _ _EXIST C/G�
_- � _ �--CO-
-7
o-- - y- � _ EXIST R/W---*.,
I
21 W4-2
1.
REMOVE CONFLICTING EXISTING STRIPING/MARKINGS BY SANDBLASTING
2.
APPLY
DOUBLE YELLOW PER MUTCD DETAIL 22
3.
APPLY
4" WHITE RIGHT EDGELINE PER MUTCD DETAIL 27B
4.
APPLY
4" SOLID WHITE LINE (L=50')
5.
APPLY
"STOP AHEAD" LEGEND PER CITY STANDARDS
6.
APPLY
"STOP" LEGEND PER CITY STANDARDS
7.
APPLY
12" WHITE LIMIT LINE PER CITY STANDARDS
8.
APPLY
4" STRIPED WHITE LINE PER DETAIL 9
9.
REFRESH STRIPING OR LEGENDS AS NECESSARY
10.
APPLY
18' TYPE VI ARROW PER MUTCD FIG. 3B-21
11.
APPLY
CHANNELIZING LINE PER MUTCD DETAIL 38
No
SIGNING CONSTRUCTION NOTES
21. INSTALL SIGN PER CITY STANDARD DETAIL 4003
22. PLACE TYPE L MARKERS ON EX PP PER STREET PLANS
CITY SIGNING AND STRIPING GENERAL NOTES
O
O
O
�D
+w
0-1
N 3:
W OJ
Z w
J m
w
= w
V
Q
1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
2. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, DIMENSIONS,
AND PROCEDURES DESCRIBED IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES
FOR STREETS AND HIGHWAYS, DATED JANUARY 2010.
3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAY PRIOR TO REMOVAL
OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL
4. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL
CONFORM TO THESE PLANS, THE STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA,
THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS,
DATED JANUARY, 2010.
5. TWO WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY ENGINEER (909) 350-7610 FOR APPROVAL
OF CONTROL POINTS OR "CAT TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING .
6. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS, UNLESS OTHERWISE SHOWN ON PLANS.
7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE
PLANS, PER CITY STANDARD DETAIL 4003.
8• STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS.
9. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED.
10. CROSSWALKS SHALL HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE
SHOWN THE PLANS, PER CITY STANDARD DETAIL 1003.
11. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE DEVELOPER, WHO SHALL
PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTODESK CAD FILES, TO THE CITY ENGINEER.
12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING.
13. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38
ON HIGHWAYS WITH RAISED MEDIANS.
14. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY
STANDARD PLAN.
-- -- -- -- -- ----- -- -- -- -- - -- -- -- -- -- -- -- -- -- --
EXIST R/W 7-7
EXIST C/G�� EXIST C/G�-
N
M
21- 22- 23- 24- 25- 26-
1
N
EXIST C/G:i_� EXIST R W 3
TOLL FREE -qmmmmlw'1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
POPLAR AVENUE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
QFtOFESS�p
w
No. 46354
Exp. 12/31/12
F
OF CA1-�FO�
EXIST C/G�-
z
0
�w
w
_Z
a.„
o V)
L
+off
rl_zx
N w
Prepared Under The Supervision Of
BLAINE A. WOMER, RCE, PRESIDENT
BLAINE A. WOMER CIVIL ENGINEERING
41555 E. FLORIDA AVENUE, SUITE G DRAWN BY:
HEMET, CA 92544 RWS
PH 51-658 1727 DESIGNED BY:
1-658- 47 DT
ate ;� u CHECKED BY;
B ame A. logmler R.C.E. 46354 BAW
APN 0237-101-16-0000
ASP 08-027
CITY OF FONTANA, CALIFORNIA
SIGNING AND STRIPING PLAN
SANTA ANA AVENUE SC 1 E' = 40'
AT DATE:
POPLV AVENUE 09-08-11
APP E 10,DRAWING NO.:
4821
@Trr1
'
E R R. .E. 51152 DATE 1 1
REVISION DESCRIPTION
POPLAR AVENUE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
QFtOFESS�p
w
No. 46354
Exp. 12/31/12
F
OF CA1-�FO�
EXIST C/G�-
z
0
�w
w
_Z
a.„
o V)
L
+off
rl_zx
N w
Prepared Under The Supervision Of
BLAINE A. WOMER, RCE, PRESIDENT
BLAINE A. WOMER CIVIL ENGINEERING
41555 E. FLORIDA AVENUE, SUITE G DRAWN BY:
HEMET, CA 92544 RWS
PH 51-658 1727 DESIGNED BY:
1-658- 47 DT
ate ;� u CHECKED BY;
B ame A. logmler R.C.E. 46354 BAW
APN 0237-101-16-0000
ASP 08-027
CITY OF FONTANA, CALIFORNIA
SIGNING AND STRIPING PLAN
SANTA ANA AVENUE SC 1 E' = 40'
AT DATE:
POPLV AVENUE 09-08-11
APP E 10,DRAWING NO.:
4821
@Trr1
'
E R R. .E. 51152 DATE 1 1