HomeMy WebLinkAbout3789-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICA71ONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT 1S FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
J. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC
EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
SAFETY.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER
REQUIREMENTS.
13. CURVE DA TA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES.
A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25
MILES PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE
TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF
THE SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL
OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH
GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET
SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS
AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
5'
MIN.
GRIND 0.10' MIN.
EXISTING PAVEMENT
AND OVERLAY 0.10' MIN.
NEW PAVEMENT
EXISTING PAVEMENT
REMOVE EXISTING REDWOOD
HEADER WHERE APPLICABLE
r,,_,_-'�J�01N_E�XlST�ING�PA VEMENT DETAIL
1' MIN.
SAWCUT AND REMOVE
EXISTING PAVEMENT
REMOVE EXISTING AC CURB OR
CURB & GUTTER WHERE APPLICABLE
A
NOT TO SCALE
STREET IMPROVEMENT PLANS
.M. NO. 1 w 2� -SIERRA = = INESS
S
PAR
IER ' A AVENU TAMARIND
Fri-
AVENUE,
SANTA
ANA AVENUE,
SL CAJVER AVEN E T CHNOLO Y
= T ' EET
EL .......
ELEVA TION
UTILITY PROVIDERS
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6731
GAS
SOUTHERN CALIFORNIA GAS CO.
SAN DIMAS CA 91773
(800)427-2000
WATER
WEST SAN BERNARDINO COUNTY WATER DISTRICT
855 WEST BASELINE, P.O. BOX 920
RIALTO, CALIFORNIA 92377-0920
(909) 875-1804
TELEPHONE
SBC PACIFIC BELL
(800) 750-2355
ELECTRIC
RON CARDENAZ
SOUTHERN CALIFORNIA EDISON
(909) 357-6240
CABLE - TV
ADELPHIA COMMUNICATIONS
5944 SYCAMORE COURT
CHINO, CA 91710
(909) 591-9571
UNAUTHORIZED CHANGES AND USES
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR,
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
NOTES.
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE
CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST OF
THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE
C1 TY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR JOB SITE COND17IONS DURING THE COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT
SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR 1S REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO
THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE
PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS
SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S.
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
RELATIONS' "CONSTRUCTION SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS"
OF THE U.S. DEPARTMENT OF LABOR OR K17H THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS".
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING 774E COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT 774IS REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL UABILI7Y, REAL OR ALLEGED, IN CONNEC71ON WITH THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR
ENGINEER.
Q) Fza v
Q 00 Ca � � o v � 000
p Z I Z I UW Z I Z I
O- 0� ��= O� 0�
w
I 4� QClq . V
CL 4 �
LOCAL DEPRESSION DETAIL
ADDED DRIVEWAYS ON SHEETS 4,6,12,14,16,17,18,&19; REMOVED ADA ACCESS RAMPS ON SHEET 6; RELOCATED BUS STOP ON SHEET
10 AND 12; REVISED MEDIAN BREAK ON SHEET 15; REVISED PLANS TO EXCLUDE WORK IN COUNTY RIGHT-OF-WAY ON SHEET 2,7,8,9,&1
BASIS OF BEARING
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA STATE PLANE
COORDINATE SYSTEM ZONE 5. BASED LOCALLY ON THE COUNTY OF SAN
BERNARDINO GPS STATION 20377 FILED IN BOOK 004015 PAGE 001548 ON
FILE IN THE OFFICE OF THE COUNTY SURVEYOR OF SAID COUNTY AND GPS
STATION 20384 FILED IN BOOK 004015 PAGE 001555 ON FILE IN THE OFFICE
OF SAID COUNTY SURVEYOR.
BENCHMARK ELEV. 1077.40
LOCATION:
CHISELED BOX IN EASTERLY TOP OF CURB
TAMARIND AVE., 60' SOUTH OF TAMARIND CT.,
500' SOUTH OF SLOVER AVENUE.
NOT TO SCALE
NOTE.
CONSTRUCTION NOTES
THE QUAN77TIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
A. CONTRACTOR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
AFTER FINAL PAVING HAS BEEN INSTALLED.
O CONSTRUCT CONCRETE CURB PER CITY OF FONTANA STD. NO. 1003 (6" CURB) ..................................... 3018 LF
O2CONSTRUCT CONCRETE CURB AND GUTTER PER CITY OF FONTANA STD. NO. 1003 (8" CURB AND GUTTER). .14618 LF
O5 CONSTRUCT 5' WIDE CONCRETE SIDEWALK PER CITY OF FONTANA STD. NO. 1015 ...................................67290 SF
s� CONSTRUCT ACCESS RAMP PER CITY OF FONTANA STD. NO. 1006........................................................14 EA
*O CONSTRUCT 6.5" MIN. AC OVER 12" MIN. 95% COMPACTED NA77VE SUBGRADE.................................... 506644 SF
* 11 CONSTRUCT 6.5" MIN. AC OVER 12" MIN. 957. COMPACTED NATIVE SUBGRADE...................................... 10410 SF
13 PLACE 12" 7741CK 3/4" GRAVEL OVER COMPACTED NATIVE (HORIZONTAL DIMENSIONS AS INDICATED ON PLAN)......
15 CONSTRUCT RESIDENTIAL DRIVEWAY ENTRANCE PER CITY OF FONTANA STD. NO. 102 ................................. 6 EA
20 CONSTRUCT 6" AC DIKE PER CITY OF FONTANA STD. DETAIL 136.......................................................�3 L
FF
25 CONSTRUCT 0" TO 6" CURB TRANSITION (L=2' OR AS OTHERWISE NOTED)........................................4 .13. -1., EA 1
o
28 ADJUST VALVE COVER TO GRADE AFTER FINAL PAVING HAS BEEN INSTALLED ............................................
29 ADJUST MANHOLE RIM TO GRADE AFTER FINAL PAVING HAS BEEN INSTALLED ............................................
41 REMOVE, SALVAGE, AND RELOCATE (TYPE AS INDICATED ON PLAN)......................................................... 2 EA
G
a REMOVE EXISTING WOODEN BOLLARD.........................................................................................`
O43 CONSTRUCT DRIVE APPROACH PER CITY OF FONTANA STD. NO. 1005A ............................................ ... 24.. `4,,EA
1
CONSTRUCT LOCAL DEPRESSION FOR CURB INLET STRUCTURE CITY 0F FONTANA .........................O
STD. DETAIL 121 AND DETAIL ON SHEET 1
S SAWCUT AND REMOVE EXISTING AC PAVING............................................................................... 112678 SF
61 SAWCUT AND REMOVE EXISTING PCC CURB & GUTTER..................................................................... 3270 LF
62 SAWCUT AND REMOVE EXISTING PCC SIDEWALK............................................................................. 28665 SF
S
S REMOVE EXISTING TREE (SIZE PER PLAN)........................................................................................ 160 EA
72 SAWCUT AND REMOVE EXISTING PCC CURB.....................................................................................1040 LF
78 RELOCATE EXISTING VAULT BY 0774ERS............................................................
so RELOCATE EXISTING FIRE HYDRANT BY OTHERS................................................................................... 8 EA
s1 RELOCATE EXISTING STREET LIGHT & APPURTENANCES BY OTHERS...........................................................
S EXIS77NG POWER POLE TO BE RELOCATED BY EDISON COMPANY.............................................................
85 RELOCATE EXISTING TRAFFIC SIGN.................................................................................................... 3 EA
S
86 EXISTING TRAFFIC SIGNAL TO BE RELOCATED PER TRAFFIC SIGNAL PLANS .................................................
S
90 PROTECT 1N PLACE (ITEM AS INDICATED ON PLAN).............................................................................
0
92 EXISTING OVERHEAD POWER LINES TO BE UNDERGROUNDED BY EDISON COMPANY................. ....................... .
93 EXISTING POWER POLE TO BE REMOVED BY EDISON COMPANY............................................................... .
116 RELOCATE EXISTING CABLE TV PULLBOX BY OTHERS........................................................................... .
117 REMOVE EXISTING CATCH BASIN...................................................................................................... 1 EA
9 REMOVE EXISTING STANDPIPE.......................................................................................................... 2 EA
184 SAWCUT, REMOVE & REPLACE EXIS71NG PCC PAVEMENT IN KIND.......................................................... 170 SF
1s6 EXIS77NG GUY POLE AND APPURTENANCES TO BE REMOVED BY EDISON COMPANY .......................................
193 REMOVE EXISTING SIGN................................................................................................................. 29 EA
195 SAWCUT & REMOVE EXISTING DRIVEWAY AND APPURTENANCES............................................................... 5 EA
199 REMOVE EXISTING CROSS GUTTER.................................................................................................1655 SF
202 EXISTING LIGHT POLE AND APPURTENANCES TO BE REMOVED BY EDISON COMPANY .....................................
203 SAWCUT & REMOVE EXISTING CONCRETE IN AREAS INDICATED............................................................... .
225 GRIND EXISTING AC MINIMUM 5' WIDE, 0.10' DEEP AND OVERLAY PER DETAIL ON SHEET 1 ...................... 59100 SF
231 COLD PLANE EXISTING AC MINIMUM 0.10' DEPTH & AC OVERLAY TO MATCH PROPOSED DESIGN GRADES...... 3867 SF
24o CONSTRUCT ACCESS RAMP PER DESIGN SHOWN ON PLANS.................................................................... 2 EA
276 EXISTING STREET LIGHT TO BE RELOCATED BY EDISON COMPANY.............................................................
294 CONSTRUCT DRIVE APPROACH PER CITY OF FONTANA STD. NO. 1005A (MODIFIED M714 CROSS GUTTER STD. 104) .................... 2 EA
296 CONSTRUCT TAPER PER APWA STD. PLAN 140-2 SHOWN ON SHEET 2 (LENGTH AS SHOWN ON PLAN) .............
297 CONS77?UCT MEDIAN FLARE PER APWA STD. PLAN 141-1 SHOWN ON SHEET 2 (LENGTH AS SHOWN ON PLAN)...
305 CONSTRUCT MEANDERING SIDEWALK PER CITY OF FONTANA STD. NO. 1015 ........................................... 12980 SF
332 CONTRACTOR TO MODIFY EXISTING IRRIGA 77ON PIPING AS NECESSARY TO ACCOMMODATE PROPOSED ....................
DESIGN AND SHALL MAINTAIN IRRIGATION SYSTEM FUNCTIONAL AT ALL 77MES DURING CONS7RUCTION
333 CONSTRUCT BUS BAY PER CITY OF FONTANA STD. NO. 1014.................................................................. 1 EA
334 CONSTRUCT FINAL AC TOP COURSE BY OTHERS (AS DIRECTED BY CITY ENGINEER) ......................................
346 CONSTRUCT CONCRETE CURB PER CITY OF FONTANA STD. NO. 1003 (8" CURB FACE) .............................. 7190 LF
347 CONSTRUCT CURB INLET STRUCTURE PER CITY OF FONTANA STD. DETAIL 121 AND ..................................... 1 LS
EXTEND EXISTING STORM DRAIN PIPE TO ACCOMMODATE NEW CATCH BASIN LOCATION
35z CONSTRUCT 6" CONCRETE CURB AND GUTTER PER CITY OF FONTANA STD. PLAN NO. 1003 ........................ 571 LF
*SEE GENERAL NOTES 31 & 32.
Q IREVISED PLANS DUE TO PROJECT COORDINATION 9/05 M.H.M. 0 - moll
NO. REVISION DESCRIPTION DATE ENGR. CITY DATE
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
r %QRpFESS/ONgl�i
O
�= ' 10, y�l
NO. 33366 • rn
EXPIRATION : �
�
'* .. 6-30-2006 .: *0p
Of
,9�; . CIV11. •�� q
1l; of CAS-\�0, r
ABBREVIATIONS
VC .......
VER TI CAL CURVE
TP .......
TOP OF PAVEMENT
TC .......
TOP OF CURB
EL .......
ELEVA TION
FL .......
FLOWLINE
FG .......
FINISH GRADE
FS .......
FINISH SURFACE
CF .......
CURB FACE
GB .......
GRADE BREAK
HP .......
HIGH POINT
INV .......
INVERT ELEVATION
TG .......
TOP OF GRATE
CB .......
CA TCH BASIN
RD .......
ROOF DRAIN
LD .......
LOCAL DEPRESSION
EP........
EDGE OF PAVEMENT
CO TG ....
F
CLEANOUT TOP OF GRATE
SMH ......
SEWER MANHOLE
R .........
RIDGE LINE
P.I.P......
PROTECT IN PLACE
CL .......
CENTERLINE
D W Y......
DRI VEWA Y
VICINITY MAP
NOT TO SCALE
SIG -IT
SHEET INDEX MAP
NOT TO SCALE
SHEET INDEX
SHEET NO.
DESCRIPTION
1
TITLE SHEET
2
TYPICAL STREET SEC77ONS & DETAILS
3-19
STREET IMPROVEMENTS PLAN & PROFILE
CONSTRUCT 6.5" MIN. AC OVER 12" MIN. 957 COMPACTED NA77VE SUBGRADE
CONSTRUCT 6.5" MIN. AC OVER 12" MIN. 957o COMPACTED NATIVE SUBGRADE
SAWCUT AND REMOVE EXISTING AC PAVING
GRIND EXISTING AC MINIMUM 5' WIDE, 0.10' DEEP AND OVERLAY PER DETAIL ON SHEET 1
COLD PLANE EXIS77NG AC MINIMUM 0.10' DEPTH & AC OVERLAY TO MATCH PROPOSED DESIGN GRADES
SAWCUT & REMOVE EXISTING CONCRETE
IN AREA INDICATED
INTERSECTION SIGHT DISTANCE LINE
Hulrrzo�s
Huitt-Zollars, Inc. Ontario
1101 S. MILLIKEN AVENUE, SUITE G * ONTARIO, CALIFORNIA 91761 * (909) 390-8400
APPROVED BY MAURICE H. MURAD
R.C.E
_�FF
EXPIRES DATE
6-30-06
3
0
r
IY
J
CITY OF FONTANA, CALIFORNIA N
0
STREET UNP OVIENEH7 PLANS
0
DRAWN BY: - SCALE: /
P.M. NO. 16264 -SIERRA BUSINESS PARK
H -Z STAFF TITLE SHEET AS SHOWN00
DESIGNED BY: DATE.
CON TRUCTION NOTES & QUANTITY ESTIMATE
M.H.M. 3-2005 0
CHECKED BY: P D__ BY• DWG. NO.: 1
M.H.M.
Lr
•05 3789
TY ENGINEER R.C.E. 51152 DATE: 19 0