HomeMy WebLinkAbout4514-2EXISTING DETAIL
D
JOIN EXISTIN(
A
BASIS OF BEARINGS:
BEARINGS ARE BASED ON THE NORTH LINE OF THE
NORTHEAST ', OF THE NORTHWEST a, OF SECTION 24,
TOWNSHIP 1 NORTH, RANGE 6 WEST, SAN BERNARDINO
MERIDIAN, AS SHOWN ON TRACT 16325, FILED IN BOOK
312 OF MAPS, AT PAGES 16 THROUGH 24, INCLUSIVE, IN
THE OFFICE OF THE COUNTY RECORDER OF SAN
BERNARDINO COUNTY, BEING NORTH 8923'57' EAST.
BENCH MARK:
DESCRIBED BY NETpcpaffAN WATER DISTRICT SO CALIFORNIA 1992
RANCHO CUCAMONGN NEAR THE IN I ERSEC IlCN OF SUMMIT AVE
AND CHERRY AVE AT THE OCA OF CHEFIRY AVE
AND SLhW AVE 101 FEET QUEST OF THE CENTERJNE CF CHERRY
AVE AND 37 FEET' SOUTH OF THE CENTERiJNE OF SUMMIT AVE SET
FLUSH ON THE NORTI-IWF.ST CORNER OF A 10 FOOT WIDE
CATCHBASIN Q8 FOOT SOUTH CF CURB FACE A STANDARD MWDOC
3 INCH BRASS DISK STAIVIPED '33A 1992'.
NAVD 88 -1508.56 (FEET)
TOLL FREE -qlmmmwp'1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE I ENGR. I CITY I DATE
GENERAL SIGNING AND STRIPING NOTES
1. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS, THE STANDARD SPECIFICATIONS
FOR THE CITY OF FONTANA, AND THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS, DATED
SEPTEMBER 2006.
2. PAVEMENT MARKINGS SHALL CONFORM TO THE CITY OF FONTANA STANDARD STENCILS
3. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC PER SPECIAL PROVISIONS.
4. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE SHOWN ON THE PLANS.
5. ALL SIGNS SHALL BE MOUNTED ON A GALVANIZED STEEL POST, UNLESS OTHERWISE SHOWN, PER CITY STANDARD DETAIL NO. 4003.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES.
7. CONTROL POINTS OR "CAT -TRACKING" TO BE APPROVED BY THE CITY TRAFFIC ENGINEER TWO WORKING DAYS PRIOR TO PAVEMENT STRIPING
APPLICATION.
8. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED -BY METHOD AS DESCRIBED IN SPECIAL PROVISIONS, SECTION E.
9. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD PLAN.
CONSTRUCTION NOTES
1
REMOVE EXISTING CONFLICTING STRIPING OR LEGEND BY SANDBLASTING PER SPECIAL PROVISIONS.
2
APPLY THERMOPLASTIC
12" LIMIT LINE.
3
APPLY THERMOPLASTIC
4" WHITE EDGELINE (DETAIL 27B).
4
APPLY THERMOPLASTIC
4" DOUBLE YELLOW LINE (DETAIL 22).
5
FURNISH AND INSTALL
"OM4-3 (RED)" AND BARRICADE PER CITY STANDARD DETAIL 4000.
6
FURNISH AND INSTALL
W31(CA) AND BARRICADE PER CITY STANDARD DETAIL 4000.
7
FURNISH AND INSTALL
C30(CA) EVERY 300' ON TYPE II BARRICADE
8
RELOCATE EXISTING "R1-1" WITH STREET NAME SIGNS PER CITY STANDARD DETAIL 4003.
9
APPLY THERMOPLASTIC
"STOP" PAVEMENT MARKING.
10
FURNISH AND INSTALL
GLUE -DOWN WHITE DELINEATORS AT 25' O.C.
11
REMOVE AND SALVAGE
EXISTING SIGN.
12
FURNISH AND INSTALL
R11-2 ON BARRICADE.
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN
HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY
ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM
INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT.
SEAL -ENGINEER
Q�pFESS/0
No. 51762 T
Exp. 06-30-10
*
c0\
;r37 rransportatlon & Energy
Solutlons, Inc.
441 W. SKYLINE DRIVE, LA HABRA HEIGHTS, CA 90631
PHONE: (562) 691-6635 / FAX: (562) 694-0688
PREPARED UNDER THE SUPERVISION OF:
8/07/08
GLEN R. PEDERSEN RCE C 51762 DATE
PROPOSED SIGN LEGEND
OM4-3
END LANE
CLOSED
W31 (CA) C30(CA)
40 20 0 40 80
1 "=40' GRAPHIC SCALE
CITY OF FONTANA, CALIFORNIA
SK*M NO 81'f__ PLM
J
=o
0w
Qm
�w
w
DRAWN BY: SCALE:
CM AS SHOWN ABOVE
DESIGNED BY: D=M CANYON �� DATE:
GRP/CM /j . JULY 2008
CHECKED BY:ROVED B • ^/2 DRAWING NO.: 2
GRP
CITY E GINEER R.C.E. 51152 DATE: 4514 2