HomeMy WebLinkAbout4144-21POLE AND EQUIPMENT SCHEDULE. . CIRCUIT OR P0LE RUNS POLE VEHICLE SIGNAL PEDESTRIAN PED PUSH O D12& FiT FURNISH AND INSTALL TYPE 90 NEMA CONTROLLER ASSEMBLY, INCLUDING TYPE "R" CABINET, VIDEO DETECTION SYSTEM, BATTERY BACK-UP SYSTEM AND APPURTENANT EQUIPMENT STANDARD LOCATION MOUNTING SIGNAL BUTTON HPSV REFLECTIVE STREET POLESIGNAL LUMINAIRE NAME 'SIGN z POLE SUBMITTED BY STANDARD PLAN ES -3C. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC F.B. REF. W.O. NO. SCALE SHT. NO. TOT. SHT'S. EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. a POLE HF0013 1" = 20' 21 23 NO. TYPE HEIGHT .MAST ARM *F* DIMENSION LUMINAIRE MAST ARM A B MAST MOUNTING 0 MOUNTING 0 ARROW SIGNAL BREAKER, 30AMP LIGHTING BREAKER. SIGNAL CIRCUIT SHALL BE 120V QA 26-4-129 30' 45' 15' 15' 15' 3' MAS SV -1-T --- _-- 4 .�-- 200 WATT DETAIL " B" : r4l - FURNISH AND INSTALLS' PVC SCHEDULE 40 WITH PULL -ROPE FROM P.P. #609759H z z POLE TO THE SERVICE CABINET PER S.C.E. APPROVED DRAWINGS. AT *LEAST 2 WEEKS ADVANCE MAS NOTICE SHALL BE GIVEN TO THE SOUTHERN CALIFORNIA EDISON COMPANY BY U 1-A 109 --- --- --- 16' 4' --- TV- 1-T 04 SP -1 -T --- --- --- — — — C 17-3-129 30' 20' --- 15' 2' 3' MAS SV -1-T --- --- --- --- 200 WATT DETAIL "A$ 1—A 149 --- --- --- 72 30 --- SHEETING DIAMOND GRADE "VIP". THE STREET NAME SIGN(S) SHALL BE INSTALLED --- --- --- -- --- — — — Q — -129 -9-4-129. 9 4 30' 30' 12' 15` 24' 4' MAS SV -1-T 02 SP -1 -T --- --- 200 WATT DETAIL STANDARD PLAN ES -7N, DETAIL U . MAS i� 10 - FURNISH AND INSTALL 3M OPTICOM MODEL 711 EMERGENCY VEHICLE PREEMPTION Q 1-A 10' ---- --. --- 25' 4' --- TV- 1-T --- --- 02kZj —� --- -- —— QG 17-3-1.29 30' . , 20' --- 15' 25' 4' MAS Sv-1—T 04 SP -1 y�2 _ 200 WATT DETAIL O 25' 4' TV -2-T 02 SP -1 -T 944 —�. --- — — — CONDUCTOR AND CONDUIT TABLE A.W.G. CIRCUIT OR P0LE RUNS 0 0 0 O O D12& FiT FURNISH AND INSTALL TYPE 90 NEMA CONTROLLER ASSEMBLY, INCLUDING TYPE "R" CABINET, VIDEO DETECTION SYSTEM, BATTERY BACK-UP SYSTEM AND APPURTENANT EQUIPMENT O D DRAWN BY DESIGNED BY w n RECOMMENDED /APPROVED BY H.F. E.R. (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CALTRANS v z 10 LUMINAIRES - 2 2 2 2 2 2 1 2 1- VIDEO VIDEO CABLE- 1 1 2 Z 1 1 4 4 DETECTION VIDEO SERVICE - � 1 21 2 1 1 j 1 1 4 4 OF PUBLIC WORKSAT HEMLOCK AVENUE 0 WDEPARTMENT 0 FiT FURNISH AND INSTALL TYPE 90 NEMA CONTROLLER ASSEMBLY, INCLUDING TYPE "R" CABINET, VIDEO DETECTION SYSTEM, BATTERY BACK-UP SYSTEM AND APPURTENANT EQUIPMENT [POLE .POLE U DRAWN BY DESIGNED BY w n RECOMMENDED /APPROVED BY H.F. E.R. (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CALTRANS v z POLE SUBMITTED BY STANDARD PLAN ES -3C. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC F.B. REF. W.O. NO. SCALE SHT. NO. TOT. SHT'S. EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. a POLE HF0013 1" = 20' 21 23 THE CONTROLLER ASSEMBLY AND BATTERY BACK UP SYSTEM SHALL BE TESTED a BY REPUBLIC ELECTRIC, SEE SPECIAL PROVISIONS. 0 POLE 2�- FURNISH AND INSTALL 120/240V TYPE III -BF SIGNAL AND LIGHTING SERVICE. USE '50AMP SIGNAL BREAKER, 30AMP LIGHTING BREAKER. SIGNAL CIRCUIT SHALL BE 120V N POLE QF METERED AND LIGHTING SHALL BE 120V UNMETERED. PROVISIONS SHALL BE MADE FOR MOUNTING THE TYPE "V' PHOTOELECTRIC UNIT IN THE SERVICE CABINET. U POLE 3�- FURNISH AND INSTALL TYPE "V' PEC (LIGHTING TYPE) IN SERVICE CABINET. r4l - FURNISH AND INSTALLS' PVC SCHEDULE 40 WITH PULL -ROPE FROM P.P. #609759H z z POLE TO THE SERVICE CABINET PER S.C.E. APPROVED DRAWINGS. AT *LEAST 2 WEEKS ADVANCE F NOTICE SHALL BE GIVEN TO THE SOUTHERN CALIFORNIA EDISON COMPANY BY U CONTACTING THE CUSTOMER SERVICE PLANNER, RDN CARDENAS AT [(909)357-62401. EXACT LOCATIONS SHALL BE DETERMINED BY S.C.E. IN THE FIELD. F51- FURNISH AND INSTALL 3" PVC SCHEDULE 80 RISER AND 36" RADIUS 99 SWEEP ON -P.P. #609759H PER S.C.E. APPROVED DRAWINGS. TOTAL 1/1 2/2 3/3 4/415/51 1 /1- 2/2 8/8 8/8 10 LUMINAIRES - 2 2 2 2 2 2 1 2 1- VIDEO VIDEO CABLE- 1 1 2 Z 1 1 4 4 DETECTION VIDEO SERVICE - � 1 21 2 1 1 j 1 1 4 4 OPTICOM CABLE - 1 1 2 2 1 1 1 1 1 4 1 4 CONDUIT SIZE (INCHES)''' 4" 4" �' �' 2-4" 1. 2-4A TRAFFIC SIGNAL GENERAL -NOTES: 1- ALL VEHICLE INDICATIONS SHALL BE 12" AND SHALL BE INSTALLED WITH "LEY' SIGNAL MODULES. (GENERAL ELECTRIC). 2- ALL PEDESTRIAN HEADS SHALL BE INSTALLED WITH "LED" PEDESTRIAN MODULES, (GENERAL ELECTRIC). 3- SIGNAL POLE LOCATIONS ARE APPROXIMATE. 4- ALL BACK PLATES SHALL BE LOUVERED. 5- ALL BACK PLATES AND VISORS SHALL BE METAL, NO PLASTIC PARTS WILL BE ALLOWED. 6- UNLESS OTHERWISE NOTED, ALL PULL BOXES SHALL BE #5. 7- PULL BOXES SHALL BE INSTALLED PER CALTRANS STANDARDS PLAN ES -8. AND SHALL NOT BE INSTALLED IN OR WITHIN A CURB ACESS RAMP. 8- PULL BOXES LOCATED IN ROADWAYS OR SHOULDER AREAS SUBJECT TO TRAFFIC, SHALL BE TRAFFIC TYPE PER CALTRANS STANDARD PLAN ES -8. 9- SLEEVE NUTS SHALL BE USED FOR ALL (1-A) POLES PER CALTRANS STANDARD PLAN ES -7B. 10- PEDESTRIAN PUSH BUTTON SHALL BE PER CALTRANS STANDARD PLANS ES -5C (TYPE B). AND ES -7A. 11- TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 12- ALL UNUSED TENONS SHALL BE CAPPED. 13— THE CONTRACTOR SHALL NOTIFY COUNTY REPRESENTATIVE TO SCHEDULE A FIELD REVIEW WITH TRAFFIC DIVISION TO DETERMINE THE EXACT LOCATIONS FOR SIGNAL POLES, CONTROLLER CABINET, AND SERVICE CABINET. MARK Underground Service Alert SECTION 4216/4217 OF THE GOVERNMENT ORE ro CODE REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG CHANGES NO CHANGES RESIDENT ENGINEER FIELD CHANGES GRAPHIC SCALE 1"=20' 0 20 40 60 Y. � c W ;ANO. C043788 m EXPIRATION DATE * 6/30/2007 CIVI-. DATE= Of CAL���� . r 0) San Bernardino Ave (D3) DETAIL N.T.S. 0 0 D in N A 0 Hemlock Avel B o z ILw (D3_) DETAIL L.te N.T.S. LEGEND: A 1/27 WHITE REFLECTIVE BORDER B 8" U.C. AND 6" L.C. C 18" D VARIES NOTE: DETAILS "A" AND "B" BACKGROUND COLOR = GREEN LETTER COLOR = WHITE �-- 06 ro, AND X16 05 —J 02 02P J!2 AND �5 nn 0 0 PELCO AB -121 OR EQUAL 0 SIGNAL MAST ARM EMERGENCY VEHICLE DETECTOR MAST ARM MOUNTING CLAMP N.T.S. PHASE SEQUENCE DIAGRAM 06 02 02P 02 AND 06 A 04 Ill 04P � 08 fd4 AND X68 NOTE: . NEGATIVE "A" DIMENSIONS REFER TO A DISTANCE DEPARTING INTERSECTION AWAY FROM BCR OR ECR. SIGNAL POLE LOCATION DETAIL N.T.S. 0 a z 0 U W M Y U 0 M 0 0 a 0 z 0 Q z X W CP z U) COUNTY OF SAN BERNARDINO SAN BERNAKRODIN-0 AVENUE a TRAFFIC SIGNAL CONSTRUCTION NOTES: N. J OF PUBLIC WORKSAT HEMLOCK AVENUE 0 WDEPARTMENT 0 FiT FURNISH AND INSTALL TYPE 90 NEMA CONTROLLER ASSEMBLY, INCLUDING TYPE "R" CABINET, VIDEO DETECTION SYSTEM, BATTERY BACK-UP SYSTEM AND APPURTENANT EQUIPMENT ���p�� TRAFFIC SIGNAL PLAN U DRAWN BY DESIGNED BY w n RECOMMENDED /APPROVED BY H.F. E.R. (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CALTRANS 11 ASSISTANT DIRECTOR DATE FONTANA AREA 0 0 SUBMITTED BY STANDARD PLAN ES -3C. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC F.B. REF. W.O. NO. SCALE SHT. NO. TOT. SHT'S. EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. a JL 8227 HF0013 1" = 20' 21 23 THE CONTROLLER ASSEMBLY AND BATTERY BACK UP SYSTEM SHALL BE TESTED a BY REPUBLIC ELECTRIC, SEE SPECIAL PROVISIONS. 2�- FURNISH AND INSTALL 120/240V TYPE III -BF SIGNAL AND LIGHTING SERVICE. USE '50AMP SIGNAL BREAKER, 30AMP LIGHTING BREAKER. SIGNAL CIRCUIT SHALL BE 120V METERED AND LIGHTING SHALL BE 120V UNMETERED. PROVISIONS SHALL BE MADE FOR MOUNTING THE TYPE "V' PHOTOELECTRIC UNIT IN THE SERVICE CABINET. 3�- FURNISH AND INSTALL TYPE "V' PEC (LIGHTING TYPE) IN SERVICE CABINET. r4l - FURNISH AND INSTALLS' PVC SCHEDULE 40 WITH PULL -ROPE FROM P.P. #609759H z TO THE SERVICE CABINET PER S.C.E. APPROVED DRAWINGS. AT *LEAST 2 WEEKS ADVANCE F NOTICE SHALL BE GIVEN TO THE SOUTHERN CALIFORNIA EDISON COMPANY BY CONTACTING THE CUSTOMER SERVICE PLANNER, RDN CARDENAS AT [(909)357-62401. EXACT LOCATIONS SHALL BE DETERMINED BY S.C.E. IN THE FIELD. F51- FURNISH AND INSTALL 3" PVC SCHEDULE 80 RISER AND 36" RADIUS 99 SWEEP ON -P.P. #609759H PER S.C.E. APPROVED DRAWINGS. F61-- FURNISH AND INSTALL VEHICLE DETECTION SYSTEM. CAMERAS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, SEE SPECIAL PROVISIONS. �- FURNISH AND ANSTALL DOUBLE SIDED STREET NAME SIGNS PER DETAILS SHOWN ON PLAN. SIGNS) SHALL BE ALUMINUM BASE METAL SURFACED .WITH REFLECTIVE SHEETING DIAMOND GRADE "VIP". THE STREET NAME SIGN(S) SHALL BE INSTALLED ON A SEPERATE HORIZONTAL ARM, SEE SPECIAL PROVISIONS. �- FURNISH AND INSTALL R73-3 (36x315') SIGN ON SIGNAL MAST ARM PER CALTRANS STANDARD PLAN ES -7N, DETAIL "U". F91- FURNISH AND INSTALL R3-4 (24�' x24') SIGN ON SIGNAL MAST ARM PER CALTRANS o STANDARD PLAN ES -7N, DETAIL U . i� 10 - FURNISH AND INSTALL 3M OPTICOM MODEL 711 EMERGENCY VEHICLE PREEMPTION Q t`�"1 (E.V.P.) SYSTEM OR EQUAL. THE SYSTEM SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS AND DETAIL SHOWN ON PLAN. 0 [111- AND INSTALL 2" CONDUIT WITH PULL -ROPE FROM EXISTING TELEPHONE BOX .FURNISH TO CONTROLLER CABINET PER SBC REQUIREMENTS. CONTACT SBC SERVICE PLANNER, BRIAN SNOWDEN AT [(714)666-5415] FOR APPROVED DRAWINGS. -12FURNISH. AND INSTALL R9 -3A SIGN S. ON' SIGNAL POLE AS SHOWN ON PLAN. F O 13' - NOT USED ON .THIS PLAN. o' 0 TRAFFIC -SIGNAL INTERCONNECT (SIC) -NOTES:. F4 - FURNISH AND INSTALL YAGI ANTENNA ON SIGNAL POLE. FURNISH AND INSTALL SOLID CORE LMR COAX CABLE FROM THE DESIGNATED ANTENNA TO THE CONTROLLER CABINET, AS SHOWN ON THE PLAN. THE EXACT LOCATION OF THE ANTENNA SHALL BE DETERMINED IN THE FIELD (SEE SPECIAL PROVISIONS). F151- FURNISH AND INSTALL ENCOM RADIO MODEM OR EQUAL. CONTRACTOR SHALL SUPPLY NECESSARY EQUIPMENT TO ENABLE COMPLETE OPERATION OF SPREAD SPECTRUM SYSTEM AT 9600 BAUD RATE. Y N � . TRAFFIC SIGNAL GENERAL -NOTES: 1- ALL VEHICLE INDICATIONS SHALL BE 12" AND SHALL BE INSTALLED WITH "LEY' SIGNAL MODULES. (GENERAL ELECTRIC). 2- ALL PEDESTRIAN HEADS SHALL BE INSTALLED WITH "LED" PEDESTRIAN MODULES, (GENERAL ELECTRIC). 3- SIGNAL POLE LOCATIONS ARE APPROXIMATE. 4- ALL BACK PLATES SHALL BE LOUVERED. 5- ALL BACK PLATES AND VISORS SHALL BE METAL, NO PLASTIC PARTS WILL BE ALLOWED. 6- UNLESS OTHERWISE NOTED, ALL PULL BOXES SHALL BE #5. 7- PULL BOXES SHALL BE INSTALLED PER CALTRANS STANDARDS PLAN ES -8. AND SHALL NOT BE INSTALLED IN OR WITHIN A CURB ACESS RAMP. 8- PULL BOXES LOCATED IN ROADWAYS OR SHOULDER AREAS SUBJECT TO TRAFFIC, SHALL BE TRAFFIC TYPE PER CALTRANS STANDARD PLAN ES -8. 9- SLEEVE NUTS SHALL BE USED FOR ALL (1-A) POLES PER CALTRANS STANDARD PLAN ES -7B. 10- PEDESTRIAN PUSH BUTTON SHALL BE PER CALTRANS STANDARD PLANS ES -5C (TYPE B). AND ES -7A. 11- TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 12- ALL UNUSED TENONS SHALL BE CAPPED. 13— THE CONTRACTOR SHALL NOTIFY COUNTY REPRESENTATIVE TO SCHEDULE A FIELD REVIEW WITH TRAFFIC DIVISION TO DETERMINE THE EXACT LOCATIONS FOR SIGNAL POLES, CONTROLLER CABINET, AND SERVICE CABINET. MARK Underground Service Alert SECTION 4216/4217 OF THE GOVERNMENT ORE ro CODE REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG CHANGES NO CHANGES RESIDENT ENGINEER FIELD CHANGES GRAPHIC SCALE 1"=20' 0 20 40 60 Y. � c W ;ANO. C043788 m EXPIRATION DATE * 6/30/2007 CIVI-. DATE= Of CAL���� . r 0) San Bernardino Ave (D3) DETAIL N.T.S. 0 0 D in N A 0 Hemlock Avel B o z ILw (D3_) DETAIL L.te N.T.S. LEGEND: A 1/27 WHITE REFLECTIVE BORDER B 8" U.C. AND 6" L.C. C 18" D VARIES NOTE: DETAILS "A" AND "B" BACKGROUND COLOR = GREEN LETTER COLOR = WHITE �-- 06 ro, AND X16 05 —J 02 02P J!2 AND �5 nn 0 0 PELCO AB -121 OR EQUAL 0 SIGNAL MAST ARM EMERGENCY VEHICLE DETECTOR MAST ARM MOUNTING CLAMP N.T.S. PHASE SEQUENCE DIAGRAM 06 02 02P 02 AND 06 A 04 Ill 04P � 08 fd4 AND X68 NOTE: . NEGATIVE "A" DIMENSIONS REFER TO A DISTANCE DEPARTING INTERSECTION AWAY FROM BCR OR ECR. SIGNAL POLE LOCATION DETAIL N.T.S. 0 a z 0 U W M Y U 0 M 0 0 a 0 z 0 Q z X W CP z U) COUNTY OF SAN BERNARDINO SAN BERNAKRODIN-0 AVENUE a J OF PUBLIC WORKSAT HEMLOCK AVENUE 0 WDEPARTMENT 0 ���p�� TRAFFIC SIGNAL PLAN U DRAWN BY DESIGNED BY PROD. fNGR. RECOMMENDED /APPROVED BY H.F. E.R. C.N.O. 11 ASSISTANT DIRECTOR DATE FONTANA AREA 0 0 SUBMITTED BY F.B. REF. W.O. NO. SCALE SHT. NO. TOT. SHT'S. CHIEF TRAFFIC DIVISION DATE DIRECTOR 0 PLIBUC WORKS JL 8227 HF0013 1" = 20' 21 23