HomeMy WebLinkAbout4144-20w 0 Q W z 0 U) R Fi POLE AND EQUIPMENT SCHEDULE .CIRCUIT OR POLE RUNS POLE VEHICLE SIGNAL PEDESTRIAN PED PUSH z� 2k 1 0 STANDARD LOCATION MOUNTING SIGNAL BUTTON HPSV REFLECTIVE STREET -POLE LUMINAIRE � NAME SIGN BY REPUBLIC ELECTRIC, SEE SPECIAL PROVISIONS. z POLE FURNISH ' AND INSTALL 120/240V -TYPE III -BF SIGNAL AND LIGHTING. SERVICE. USE 50AMP br���o FONTANA AREA SIGNAL BREAKER, 30AMP LIGHTING BREAKER. SIGNAL CIRCUIT SHALL BE 120V Q• SUBMITTED BY METERED AND LIGHTING SHALL BE 120V UNMETERED. PROVISIONS SHALL BE NO. TYPE HEIGHT SIGNAL MAST ARM. F DIMENSION. LUMINAIRE MAST ARM A g � MAST MOUNTING 0 MOUNTING 0 ARROW 1» = 20' 20 OA 29-5-129 30 ' 50 15 15 13' 31 MAS SV- 1-T 6 Sp -1-T 04 �--- 200 WATT DETAIL oU POLE © SIGN(S) SHALL BE ALUMINUM BASE METAL SURFACED WITH REFLECTIVE SHEETING DIAMOND GRADE "VIP". THE STREET NAME SIGN(S) SHALL BE INSTALLED MAS ON A SEPERATE HORIZONTAL ARM, SEE SPECIAL PROVISIONS. zPOLE Q �- FURNISH AND IN R73-3 (36"x36') SIGN ON SIGNAL MAST ' ARM PER CALTRANS 13' 4' --- TV- 1-T 04 SP -1 -T 0 STANDARD PLAN ES -7N, DETAIL $I W. -- - 1-A 10' --- --- --- 0 M 15 1 3' 4' MAS SV -1-T 08 SP -1 _ 06 �--- 200 WATT DETAIL © 19-4-129'3p 25 --- n13- NOT USED ON THIS . PLAN. TV -2-T 06 SP -1 -T 08 —� - FURNISH AND INSTALL YAGI - ANTENNA ON SIGNAL POLE. FURNISH AND INSTALL SOLID CORE LMR COAX O 24-4-i29 30 • 35 14 ' 15 14' 4' MAS SV -1-T 02 SP -1 -T 08 �- 200 WATT DETAIL c0 MAS �J 1-A 10' --- --- --- 14' 4' TV -1 T 08 SP -1 -T 02 -� © -4-29 191WATT 30' 25' --- 15' 13' 4' MAS SV -1-T 04 SP -1 02 _._ 200 DETAIL H 0 1-A 10' --- - 13' 4' TV -2-T 02 SP -1 -T 04 -�- --- --- CONDUCTOR AND. CONDUIT TABLE A.W.G. .CIRCUIT OR POLE RUNS 0 — — z� 2k 1 0 0 0 �y 2 EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. U_ DRAWN BY DESIGNED BY PROJ. ENGR. RECOMMENDED /APPROVED BY THE CONTROLLER ASSEMBLY AND BATTERY BACK UP SYSTEM SHALL BE TESTED H.F. E.R. C.N.O.TRAFFIC BY REPUBLIC ELECTRIC, SEE SPECIAL PROVISIONS. o POLE Q - — — — — — — — 1/1 1/1 POLE QB �y 2 EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. U_ DRAWN BY DESIGNED BY PROJ. ENGR. RECOMMENDED /APPROVED BY THE CONTROLLER ASSEMBLY AND BATTERY BACK UP SYSTEM SHALL BE TESTED H.F. E.R. C.N.O.TRAFFIC BY REPUBLIC ELECTRIC, SEE SPECIAL PROVISIONS. z POLE FURNISH ' AND INSTALL 120/240V -TYPE III -BF SIGNAL AND LIGHTING. SERVICE. USE 50AMP br���o FONTANA AREA SIGNAL BREAKER, 30AMP LIGHTING BREAKER. SIGNAL CIRCUIT SHALL BE 120V Q• SUBMITTED BY METERED AND LIGHTING SHALL BE 120V UNMETERED. PROVISIONS SHALL BE POLE MADE FOR MOUNTING THE TYPE "V' PHOTOELECTRIC UNIT IN THE SERVICE CABINET. F.B. REF. �- FURNISH AND INSTALL TYPE "V' PEC (LIGHTING TYPE) IN SERVICE CABINET. SMT. N0. 44- FURNISH AND INSTALLS' PVC SCHEDULE 40 WITH ULL-ROPE FROM P.P. #4446064E TO THE SERVICE CABINET PER S.C.E. APPROVED DRAWINGS. AT LEAST 2 WEEKS ADVANCE POLE QE JL 82.27 NOTICE SHALL BE GIVEN TO THE SOUTHERN CALIFORNIA EDISON COMPANY BY 1» = 20' 20 CONTACTING THE CUSTOMER SERVICE PLANNER, RON CARDENAS AT [(909)357-62401. EXACT LOCATIONS SHALL BE DETERMINED BY S.C.E. IN THE FIELD. 04 POLE QF ON P.P. #4446064E PER S.C.E. APPROVED DRAWINGS. n6 - FURNISH AND INSTALL VEHICLE DETECTION SYSTEM. CAMERAS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, SEE SPECIAL PROVISIONS. oU POLE © SIGN(S) SHALL BE ALUMINUM BASE METAL SURFACED WITH REFLECTIVE SHEETING DIAMOND GRADE "VIP". THE STREET NAME SIGN(S) SHALL BE INSTALLED ON A SEPERATE HORIZONTAL ARM, SEE SPECIAL PROVISIONS. zPOLE Q �- FURNISH AND IN R73-3 (36"x36') SIGN ON SIGNAL MAST ' ARM PER CALTRANS STANDARD PLAN ES -7N, DETAIL "U". �- FURNISH AND INSTALL R3-4 (24!x24!') SIGN ON SIGNAL MAST ARM PER CALTRANS 0 STANDARD PLAN ES -7N, DETAIL $I W. m10 - FURNISH AND INSTALL 3M- OPTICOM MODEL 711 EMERGENCY VEHICLE PREEMPTION (E.V.P.) SYSTEM OR EQUAL. THE SYSTEM SHALL BE INSTALLED PER THE MANUFACTURER'S 0 M TOTAL 1 /1 2/2 3/3 4/4 1 /1 2/2 3/3 8/. 8 8/8 10 LUMINAIRES 2 2 2 2 — 2 2 2 VIDEOVIDEO DEFECTION CABLE t 2 2 — > > 4 4 VIDEO SERVICE Z 2 1 4 4 OPTICOM CABLE t t 2 2 — t1 t 4 1 4 CONDUIT SIZE (INCHES) 3" 1 3" 1 4" 1 4" 2" 1 3" 1 4" 12—e 2-4" TRAFFIC SIGNAL CONSTRUCTION NOTES: 2" C - 22 W Z W v + SAN BERNARD-INO x x 3: PP 8098698h x 0 X TRAFFIC SIGNAL GENERAL NOTES: 1- ALL VEHICLE INDICATIONS SHALL BE 12" AND SHALL BE INSTALLED WITH "LED" SIGNAL MODULES (GENERAL ELECTRIC). 2- ALL PEDESTRIAN HEADS SHALL BE INSTALLED WITH "LED" PEDESTRIAN MODULES, (GENERAL ELECTRIC). 3- SIGNAL POLE LOCATIONS ARE APPROXIMATE. 4- ALL BACK PLATES SHALL BE LOUVERED. 5- ALL BACK PLATES AND VISORS SHALL BE METAL, NO PLASTIC PARTS WILL BE ALLOWED. 6- UNLESS OTHERWISE NOTED, ALL PULL BOXES SHALL BE #5. 7- PULL BOXES SHALL BE INSTALLED PER CALTRANS STANDARDS PLAN ES -8. AND SHALL NOT BE INSTALLED IN OR WITHIN A CURB ACESS RAMP. 8- PULL BOXES LOCATED IN ROADWAYS OR SHOULDER AREAS SUBJECT TO TRAFFIC, SHALL BE TRAFFIC TYPE PER CALTRANS STANDARD PLAN ES -8. 9- SLEEVE NUTS SHALL BE USED FOR ALL (1-A) POLES PER CALTRANS STANDARD PLAN ES -713. 10- PEDESTRIAN PUSH BUTTON SHALL BE PER CALTRANS STANDARD PLANS ES -5C (TYPE B) AND ES -7A. 11- TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE. STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 12- ALL UNUSED TENONS SHALL BE CAPPED. 13- THE CONTRACTOR SHALL NOTIFY COUNTY REPRESENTATIVE TO SCHEDULE A FIELD REVIEW WITH TRAFFIC DIVISION TO DETERMINE THE EXACT LOCATIONS FOR SIGNAL POLES, CONTROLLER CABINET, AND SERVICE CABINET. D 0 z a m � w X U E X w PP 1198768E Underground Service -Alert .SECTION 4216/4217 OF THE GOVERNMENT o, ro CODE REQUIRES , A DIG ALERT IDENTIFICATION Goy, NUMBER BE ISSUED BEFORE A PERMIT TO `'� �' EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG MARK CHANGES NO CHANGES RESIDENT ENGINEER DATE FIELD CHANGES D GUTTER NUE N GRAPHIC SCALE 1"=20' 0 20 40 60 San Bernardino Ave (D3) DETAIL "A N.T.S. D A _T �__[ Live Oak Ave e (D3) DETAIL "B" N.T.S. LEGEND: A 11Z WHITE REFLECTIVE BORDER B 8" U.C. AND 6" L.G. C 1`8" D VARIES NOTE: DETAILS "A" AND "Y' BACKGROUND COLOR = GREEN LETTER COLOR = WHITE 06P 06 01 L01 AND 06 05 _j 02 Pf2P 112 AND5 0 o PELCO AB -121 OR EQUAL O SIGNAL MAST ARM EMERGENCY VEHICLE DETECTOR MAST ARM MOUNTING CLAMP, N.T.S. 0) I O 0 N O Z J e.. w PHASE SEQUENCE DIAGRAM �6P 06 02 Qf2P 02 AND 06 4 04 1 4 1 04P � 108P- 08 08P08 04 AND 08 NOTE: NEGATIVE "A" DIMENSIONS REFER TO A DISTANCE DEPARTING INTERSECTION AWAY FROM BCR OR ECR. SIGNAL POLE LOCATION DETAIL N.T.S. 0 M COUNOF SAN BERNARDINO I SAN BERNARDINO AVENUE 1.0tt n- FURNISH AND INSTALL TYPE 90 NEMA CONTROLLER ASSEMBLY, INCLUDING TYPE "R" CABINET, VIDEO DETECTION SYSTEM, BATTERY BACK-UP SYSTEM AND APPURTENANT EQUIPMENT � DEPARTME'NT 0 (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CALTRANS AT LIVE OAK AVENUE STANDARD PLAN ES -3C. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC �y 2 EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. U_ DRAWN BY DESIGNED BY PROJ. ENGR. RECOMMENDED /APPROVED BY THE CONTROLLER ASSEMBLY AND BATTERY BACK UP SYSTEM SHALL BE TESTED H.F. E.R. C.N.O.TRAFFIC BY REPUBLIC ELECTRIC, SEE SPECIAL PROVISIONS. 2 - FURNISH ' AND INSTALL 120/240V -TYPE III -BF SIGNAL AND LIGHTING. SERVICE. USE 50AMP br���o FONTANA AREA SIGNAL BREAKER, 30AMP LIGHTING BREAKER. SIGNAL CIRCUIT SHALL BE 120V Q• SUBMITTED BY METERED AND LIGHTING SHALL BE 120V UNMETERED. PROVISIONS SHALL BE MADE FOR MOUNTING THE TYPE "V' PHOTOELECTRIC UNIT IN THE SERVICE CABINET. F.B. REF. �- FURNISH AND INSTALL TYPE "V' PEC (LIGHTING TYPE) IN SERVICE CABINET. SMT. N0. 44- FURNISH AND INSTALLS' PVC SCHEDULE 40 WITH ULL-ROPE FROM P.P. #4446064E TO THE SERVICE CABINET PER S.C.E. APPROVED DRAWINGS. AT LEAST 2 WEEKS ADVANCE DIRECTOR 0 BUC WORKS ^ DA JL 82.27 NOTICE SHALL BE GIVEN TO THE SOUTHERN CALIFORNIA EDISON COMPANY BY 1» = 20' 20 CONTACTING THE CUSTOMER SERVICE PLANNER, RON CARDENAS AT [(909)357-62401. EXACT LOCATIONS SHALL BE DETERMINED BY S.C.E. IN THE FIELD. a- FURNISH AND INSTALLS' PVC SCHEDULE 80 RISER AND 36" RADIUS 99 SWEEP ON P.P. #4446064E PER S.C.E. APPROVED DRAWINGS. n6 - FURNISH AND INSTALL VEHICLE DETECTION SYSTEM. CAMERAS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, SEE SPECIAL PROVISIONS. 7 - FURNISH AND INSTALL DOUBLE SIDED STREET NAME SIGNS PER DETAILS SHOWN ON PLAN.' SIGN(S) SHALL BE ALUMINUM BASE METAL SURFACED WITH REFLECTIVE SHEETING DIAMOND GRADE "VIP". THE STREET NAME SIGN(S) SHALL BE INSTALLED ON A SEPERATE HORIZONTAL ARM, SEE SPECIAL PROVISIONS. �- FURNISH AND IN R73-3 (36"x36') SIGN ON SIGNAL MAST ' ARM PER CALTRANS STANDARD PLAN ES -7N, DETAIL "U". �- FURNISH AND INSTALL R3-4 (24!x24!') SIGN ON SIGNAL MAST ARM PER CALTRANS STANDARD PLAN ES -7N, DETAIL $I W. m10 - FURNISH AND INSTALL 3M- OPTICOM MODEL 711 EMERGENCY VEHICLE PREEMPTION (E.V.P.) SYSTEM OR EQUAL. THE SYSTEM SHALL BE INSTALLED PER THE MANUFACTURER'S z SPECIFICATIONS AND DETAIL SHOWN ON PLAN. ° 11 - NOT USED ON THIS PLAN. *-4 F121 - NOT USED ON THIS. PLAN. n13- NOT USED ON THIS . PLAN. 0 TRAFFIC SIGNAL INTERCONNECT (SIC) NOTES: _0614 - FURNISH AND INSTALL YAGI - ANTENNA ON SIGNAL POLE. FURNISH AND INSTALL SOLID CORE LMR COAX *44 CABLE FROM THE DESIGNATED ANTENNA TO THE CONTROLLER CABINET, AS SHOWN ON THE PLAN. SPECIAL PROVISIONS). THE EXACT LOCATION OF THE ANTENNA SHALL BE DETERMINED IN THE FIELD (SEE n15- FURNISH AND INSTALL ENCOM RADIO MODEM OR EQUAL. CONTRACTOR SHALL SUPPLY NECESSARY EQUIPMENT TO ENABLE COMPLETE OPERATION OF SPREAD SPECTRUM SYSTEM AT 9600 BAUD RATE. c0 2" C - 22 W Z W v + SAN BERNARD-INO x x 3: PP 8098698h x 0 X TRAFFIC SIGNAL GENERAL NOTES: 1- ALL VEHICLE INDICATIONS SHALL BE 12" AND SHALL BE INSTALLED WITH "LED" SIGNAL MODULES (GENERAL ELECTRIC). 2- ALL PEDESTRIAN HEADS SHALL BE INSTALLED WITH "LED" PEDESTRIAN MODULES, (GENERAL ELECTRIC). 3- SIGNAL POLE LOCATIONS ARE APPROXIMATE. 4- ALL BACK PLATES SHALL BE LOUVERED. 5- ALL BACK PLATES AND VISORS SHALL BE METAL, NO PLASTIC PARTS WILL BE ALLOWED. 6- UNLESS OTHERWISE NOTED, ALL PULL BOXES SHALL BE #5. 7- PULL BOXES SHALL BE INSTALLED PER CALTRANS STANDARDS PLAN ES -8. AND SHALL NOT BE INSTALLED IN OR WITHIN A CURB ACESS RAMP. 8- PULL BOXES LOCATED IN ROADWAYS OR SHOULDER AREAS SUBJECT TO TRAFFIC, SHALL BE TRAFFIC TYPE PER CALTRANS STANDARD PLAN ES -8. 9- SLEEVE NUTS SHALL BE USED FOR ALL (1-A) POLES PER CALTRANS STANDARD PLAN ES -713. 10- PEDESTRIAN PUSH BUTTON SHALL BE PER CALTRANS STANDARD PLANS ES -5C (TYPE B) AND ES -7A. 11- TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE. STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 12- ALL UNUSED TENONS SHALL BE CAPPED. 13- THE CONTRACTOR SHALL NOTIFY COUNTY REPRESENTATIVE TO SCHEDULE A FIELD REVIEW WITH TRAFFIC DIVISION TO DETERMINE THE EXACT LOCATIONS FOR SIGNAL POLES, CONTROLLER CABINET, AND SERVICE CABINET. D 0 z a m � w X U E X w PP 1198768E Underground Service -Alert .SECTION 4216/4217 OF THE GOVERNMENT o, ro CODE REQUIRES , A DIG ALERT IDENTIFICATION Goy, NUMBER BE ISSUED BEFORE A PERMIT TO `'� �' EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG MARK CHANGES NO CHANGES RESIDENT ENGINEER DATE FIELD CHANGES D GUTTER NUE N GRAPHIC SCALE 1"=20' 0 20 40 60 San Bernardino Ave (D3) DETAIL "A N.T.S. D A _T �__[ Live Oak Ave e (D3) DETAIL "B" N.T.S. LEGEND: A 11Z WHITE REFLECTIVE BORDER B 8" U.C. AND 6" L.G. C 1`8" D VARIES NOTE: DETAILS "A" AND "Y' BACKGROUND COLOR = GREEN LETTER COLOR = WHITE 06P 06 01 L01 AND 06 05 _j 02 Pf2P 112 AND5 0 o PELCO AB -121 OR EQUAL O SIGNAL MAST ARM EMERGENCY VEHICLE DETECTOR MAST ARM MOUNTING CLAMP, N.T.S. 0) I O 0 N O Z J e.. w PHASE SEQUENCE DIAGRAM �6P 06 02 Qf2P 02 AND 06 4 04 1 4 1 04P � 108P- 08 08P08 04 AND 08 NOTE: NEGATIVE "A" DIMENSIONS REFER TO A DISTANCE DEPARTING INTERSECTION AWAY FROM BCR OR ECR. SIGNAL POLE LOCATION DETAIL N.T.S. 0 M COUNOF SAN BERNARDINO I SAN BERNARDINO AVENUE 1.0tt W � DEPARTME'NT 0 PUBLIC WORKS AT LIVE OAK AVENUE �y 2 SIGNAL PLAN U_ DRAWN BY DESIGNED BY PROJ. ENGR. RECOMMENDED /APPROVED BY H.F. E.R. C.N.O.TRAFFIC br���o FONTANA AREA Z Q• SUBMITTED BY ASSISTANT DIRECTOR DATE o 0 F.B. REF. W.O. N0. SCALE SMT. N0. TOT. SHT'S. 04 rn v- 8 • l S. o S . CHIEF TRAFFIC DIVISION DATE DIRECTOR 0 BUC WORKS ^ DA JL 82.27 H F0013 1» = 20' 20 23