Loading...
HomeMy WebLinkAbout3921-1TABLE 200-1.2[A] SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1/2" - 1" - 3/4" 100 1/2" 90-100 3/8" 20-60 NO. 4 0-15 NO. 8 0-5 ASTM C 131 TEST GRADING B EX. SEWER MH (1337.16) RIM FL (1330.76) N FL (1330.62) NW FL (1330.74) S PER DWG. N0. 1 86 TRACTN0. 1 681 EX. 8" SEWER MAIN PER D WG NO. 1486 BASIS OF BEARING: VTrTT%TT'TV BARSTOW RT -'FTP T TXTnVX STREET NAME TITLE SHEET FREESIA WAY 3" MAX. SIZE NA TI VE SOIL COMPACTED TO 90% 6" MAX. SIZE NA TI VE SOIL THE CENTERLINE OF MILLER AVENUE SHOWN AS N89'45'10"W PER TRACT NO. 32989 M.B. 44-179 RECORDS OF SAN BERNARDINO COUNTY GENERAL NOTES FOR TRFNr.H REPAIR 1. ALL EXCAVATION WITHIN THE CITY OF FONTANA RIGHT-OF-WAY REQUIRES AN EXCAVATION PERMIT FROM THE PUBLIC WORKS DEPARTMENT. 2. UNDERGROUND SERVICE ALERT SHALL BE NOTIFIED 2 WORKING DAYS PRIOR TO START OF WORK 1-800-422-4133. 3. ALL EXCAVATIONS SHALL BE MADE, PROTECTED, AND SUPPORTED AS REQUIRED FOR SAFETY AND IN THE MANNER SET FORTH IN THE OPERATIONS RULES, ORDERS, AND REGULATIONS PRESCRIBED BY THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY. 4. COMPACTION OF BACKFILL SHALL BE VERIFIED BY ENGINEER AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS PRIOR TO THE PLACING OF THE PERMANENT PAVEMENT. 5. PERMANENT PAVEMENT SHALL BE REPLACED WITHIN 5 DAYS OF EXCAVATION, A MINIMUM 2 -INCH THICKNESS OF TEMPORARY ASPHALT PAVING SHALL BE PLACED WITHIN THE TRENCH AREA UNTIL PERMANENT REPAIR IS COMPLETED. THE TEMPORARY PAVING SHALL BE PLACED AND COMPACTED IN SUCH A MANNER AS TO PROVIDE A SAFE AND SMOOTH TRAVELED SURFACE. PERMITTEE SHALL MAINTAIN THE TEMPORARY PAVEMENT IN A SAFE AND SMOOTH CONDITION UNTIL PERMANENT PAVING IS IN PLACE. 6. PRIOR TO PLACEMENT OF PERMANENT PAVING, EXISTING PAVEMENT CRACKED ADJACENT TO THE TRENCH SHALL BE REMOVED. 7 ALL EDGES OF EXISTING PAVEMENT BEING JOINED AND SURFACE BEING O� MONTANA IMPROVEMENT PROJECT ILLER Q HIGHLAND A AVENUE > T � L) F REESIA WAY TR. 163J9 8. TRENCHES OF 300 FEET OR MORE TO BE PAVED WITH A SELF-PROPELLED PAVING MACHINE. 9. ANY STREET PAVED OR RESURFACED IN THE PREVIOUS 36 MONTHS WHERE THE TRENCH EXTENDS FROM THE CURB MORE THAN 7 FEET OR IS IN A TRAVELED LANE, WILL REQUIRE AN OVERLAY 25 FEET IN BOTH DIRECTIONS FROM THE CENTERLINE OF TRENCH. PER NUMBER 8 ABOVE. 10. IF TRENCH FAILURE SHOULD OCCUR, THE PERMITTEE/DEVELOPER WILL BE NOTIFIED OF SUCH DEFICIENCIES AND ALLOWED TO REMOVED, REPLACE, REMODY THIS WORK. UPON FAILURE OF THE CONTRACTOR TO PROMPTLY COMPLY AND UNDER ORDER OF THE CITY ENGINEER, TRENCH FAILURE SHALL BE REMODIED, REMOVED, REPLACED AT PERMITTEE/DEVELOPER SALE EXPENSES. 11. BEDDING MATERIAL SHALL BE SAND, GRAVEL, CRUSHED AGGREGATE, OR NATIVE FREE -DRAINING GRANULAR MATERIAL HAVING A SAND EQUIVALENT OF NOT LESS THAN 30, AND SHALL HAVE A PERCENTAGE COMPOSITION BY WEIGHT WHICH CONFORMS TO THE FOLLOWING GRADING. X. 10" PKNN OVERLAID SHALL RECEIVE A TACK COAT OF ASPHALT EMULTION. WATER MAIN T'1V__Qr41Z1T10►rrn'kT VICINITY MAP, LOCATION MAP & INDEX MAP, SHEET INDEX LOCUST AVE TO FREESIA WAY FREESIA WAY 6" MIN. 10" MAX. PROPOSED A. C. PVM T. ER SEPARA TE STREET IMP. PLAN wilkitimmoll INDICATE SHEET NUMBERS. TRACT NO. 808 PROPOSED UNDERGROUND BOX CULVERT DRAIN PER SEPARATE STREET IMP. PLAN DWG NO. 3920 -- 243-251-17 1 �= 45846 t'�i UTILITY CONTACT LIST CITY OF FONTANA ATTN: BRIAN WREN 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-6632 THE GAS COMPANY ATTN: GREG GASPAR FONTANA., CA 92335 EMERGENCIES: (800) 427-2200 SO. CALIFORNIA EDISON COMPANY 7951 REDWOOD AVE. FONTANA, CA 92335 (909) 820-5598- UNDERGROUND (909) 875-5100- TRANSMISSIONS (213) 637-1233- PIPELINES (909) 357-6233- DISTRIBUTION UNDERGROUND SERVICE ALERT (800) 422-4133 METROPOLITAN WATER DISTRICT WATER SYSTEM OPERATION GROUP ATTN: JOE MIRONE (909) 776-2664 PACIFIC BELL CO. ATTN: NORMA GUILLOT 1265 N. VAN BUREN STREET SUITE 180 ANAHEIM, CA 92807 (714) 666-5401 COMCAST (CABLE N) ATTN: JACK HAYES 1205 1400 E. PHILLIPS BLVD. DUPONT AVENUE ONTARIO, CA.91761 CRAWFORD CANYON MUTUAL WATER CO. 1909) 390-4738 ATTN: BASIL J. FABRIZIO (909) 463-9580 CONSTRUCTION NOTES 1& --CONSTRUCT 4' DIA. MANHOLE PER CITY STD. DWG. NO. 112 (THE LID SHOULD BE WATER RESISTANT) 20 ---INSTALL 8" EXTRA STRENGTH V.C.P. SEWER MAIN. O3 ---INSTALL 4" V.C.P. SEWER LATERAL AND WYE PER CITY OF FONTANA STD. DWG. NO. 125 4O ---INSTALL 8" W.I.A. SEWER MAIN. O5 ---INSTALL PIPE BEDDING PER DETAIL ON SHEET 1 O6 ---INSTALL PIPE PER CITY STD. 131 , GENERAL NOTES. 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (" GREEK BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXISTS IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEK BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL NOT BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OF TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING , SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF THE INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF THE UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEMPT WHERE OTHERWISE NOTED. 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENT, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR, SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS VERIZON ATTN: STEVE HOOK POMONA, CA 91766 (909) 469-6327 FONTANA WATER COMPANY ATTN: MICHAEL J. MCGRAW 8440 NUEVO AVENUE FONTANA, CA 92335 PH: (909) 822-2201 WEST VALLEY WATER DISTRICT ATTN: LON TSAI 855 W. BASELINE ROAD RIALTO, CA 92377 METROPOLITAN WATER DISTRICT WATER SYSTEM OPERATION GROUP ATTN: JOE MIRONE (909) 776-2664 QUANTITIES 7 EA 1,223 LF 792 LF 335 LF 1, 558 LF RESURFACING 9,348 SF) ,558 LF NOT TO SCALE LOCATION MAP G2 HOMES, LLC 100 N. BARRANCA AVE. SUITE 950 WEST COVINA, CA 91791 PH: 626-858-8677 FAX: 626-858-8676 CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO- CONSTRUCTION SO THE TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM UNDERMINING STREET NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH. TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNA`ION C700. FOR V.D.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PU13LIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. AUfOCAD ALENAME: s e w e r. d w g Q HIGHLAND A cn > � L) Q > Q a BASE INE RD 0 MILLER AV >1 > a Q Z PROJECT w En SITE FOOTHI L BL ADDAW DI NOT TO SCALE LOCATION MAP G2 HOMES, LLC 100 N. BARRANCA AVE. SUITE 950 WEST COVINA, CA 91791 PH: 626-858-8677 FAX: 626-858-8676 CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO- CONSTRUCTION SO THE TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM UNDERMINING STREET NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH. TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNA`ION C700. FOR V.D.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PU13LIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. AUfOCAD ALENAME: s e w e r. d w g