HomeMy WebLinkAbout4189-1GENERAL NO TES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT /S FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS /N THE "GREEN BOOK" THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. J. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE /N PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK, INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER /N DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET /N DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTRACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS, ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A• REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF ' THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES /N THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION, FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 23 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM /N GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OR STREETS. 30. APPROVED SOILS STER/LANT /S REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. J2. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEERING. 33 AS-BULIT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER STORM DRAIN IMPROVEMENT PLAN TRACT No, 17824 Clry OF FONTANA - - V/ACAA17' (7EXIST. 36" --�T8- 4 AlN EX/ST.24'° - STORM_ DRAIN_SOUTHHI- -GHLAN- A D VENUE - LAT. _ - - - - - LAT. »Ll„ - ------ ---- - ___ - -- -- - - - OP. R/W - FIT lk !! li' I I 'E ST IN III II Zi % U E ILI III �PROP. R/W 7'rfZ NO, V-924 PR W II II jt�l ��j y7_r�I II rTRACT BOUNDARY TOP OF STRUCTURAL PAVEMENT SUBGRADE -III N i 6" MIN. III = 8" MAX. =►I I III s III - z LO w W m II ' STORM DRAIN PIPE - - GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 112" CRUSHED STONE BEDDING. TRENCH DETAIL II I� 7R' X10, 18079 li A4a .2g1 / B&I-72 II II INDEX MAP SCALE. 1 "=100' 3" MAX. SIZE NATIVE BACKFILL COMPACTED 909' NOTES: /VU/ IU J(.fiLL 1. TRENCH WIDTH SHALL BE CONTROLLED 4. COMPACTION SHALL BE 909' IN ALL TO TOP OF PIPE ZONE. ZONES UNLESS OTHERWISE SPECIFIED. 2. TRENCH DEPTHS OF GREATER THAN 5' TRENCH STABILITY SHALL CONFORM SHALL HAVE ADEQUATE SHORING. TO CAL -OSHA REQUIREMENTS. J. CLASS II AGG. BASE ALL TRENCHES LESS THAN 100' IN LENGTH. Q � 34. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE REINFORCING WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STENGTH IN OF., -THESE REACHES SHALL BE fc=5,000 psi FOR VELOCITIES EXCEED/NG 20 FEET PER SECOND AND fc= 6, 000 psi FOR VELOCITIES EXCEED/NG 30 FEET PER SECOND. DIAL 35. MINIMUM D -LOAD FOR ALL R.C.P. IS 1350. BEFORE YOU DIG 36. ADVANCE CONSTRUCT/ON SIGNING INDICATING DURATION OF PROJECT SHALL BE /N TOLL FREE 1-800-227-2600 PLACE ONE WEEK PR/OR TO IMPLEMENT/NG DETOURS A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT LEGEND A. C. B. C. B. V. C. B. W. C.B. C.L. E. C. E.P. E. G. E. V. C. F.L. F. S G.B. H.P. INV. 0. C. P. C. C. (R) R/W TAN. T. C. W V (590.77) 590.77 �pFE3S; O UJI 637 c m C 36 OF* ASPHAL TIC CONCRETE N INDICA TES SLOPE 2: 1 1:1 SLOPE OR FLATTER AC PA VEMENT f OR ADEQUATE SHORING REMOVAL CATCH BASIN CEN TERLINE ® GRIND END CUR VE EDGE OF PA VEMEN T EDGE PA VEMEN T 907 COMPACTED EDGE GRADE NAT/VE BACKFILL SEWER MAIN END VER 77CAL CURVE 6 MAX. SIZE SEWER LA TERAL GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL (1- MAX. SIZE). SEWER MANHOLE -III N i 6" MIN. III = 8" MAX. =►I I III s III - z LO w W m II ' STORM DRAIN PIPE - - GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 112" CRUSHED STONE BEDDING. TRENCH DETAIL II I� 7R' X10, 18079 li A4a .2g1 / B&I-72 II II INDEX MAP SCALE. 1 "=100' 3" MAX. SIZE NATIVE BACKFILL COMPACTED 909' NOTES: /VU/ IU J(.fiLL 1. TRENCH WIDTH SHALL BE CONTROLLED 4. COMPACTION SHALL BE 909' IN ALL TO TOP OF PIPE ZONE. ZONES UNLESS OTHERWISE SPECIFIED. 2. TRENCH DEPTHS OF GREATER THAN 5' TRENCH STABILITY SHALL CONFORM SHALL HAVE ADEQUATE SHORING. TO CAL -OSHA REQUIREMENTS. J. CLASS II AGG. BASE ALL TRENCHES LESS THAN 100' IN LENGTH. Q � 34. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE REINFORCING WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STENGTH IN OF., -THESE REACHES SHALL BE fc=5,000 psi FOR VELOCITIES EXCEED/NG 20 FEET PER SECOND AND fc= 6, 000 psi FOR VELOCITIES EXCEED/NG 30 FEET PER SECOND. DIAL 35. MINIMUM D -LOAD FOR ALL R.C.P. IS 1350. BEFORE YOU DIG 36. ADVANCE CONSTRUCT/ON SIGNING INDICATING DURATION OF PROJECT SHALL BE /N TOLL FREE 1-800-227-2600 PLACE ONE WEEK PR/OR TO IMPLEMENT/NG DETOURS A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT LEGEND A. C. B. C. B. V. C. B. W. C.B. C.L. E. C. E.P. E. G. E. V. C. F.L. F. S G.B. H.P. INV. 0. C. P. C. C. (R) R/W TAN. T. C. W V (590.77) 590.77 �pFE3S; O UJI 637 c m C 36 OF* ASPHAL TIC CONCRETE I'=F INDICA TES SLOPE 2: 1 BEGIN CUR VE BEG. VERTICAL CURVE , AC PA VEMENT BACK SIDEWALK ® REMOVAL CATCH BASIN CEN TERLINE ® GRIND END CUR VE EDGE OF PA VEMEN T EDGE PA VEMEN T EDGE GRADE SEWER MAIN END VER 77CAL CURVE SEWER LA TERAL FLOW LINE FINISH SURFACE GRADE BREAK SEWER MANHOLE HIGH POINT IN VERT SEWER CLEANOUT ON CURVE PORTLAND CEMENT CONCRETE W WATER MAIN RIDGE LINE ------- FIRE LINE RIGHT OF WA Y TANGENT FIRE HYDRANT TOP OF CURB W/D TH IRRIGATION METER VER TI CAL DEPTH INDICA TES EXISTING C-1 MIA TION ® TRENCH AND REPAIR INDICATES PROPOSED ELEVATION RC.a 3&G37 txP, r,, -30 -12 MAraoL_F, it A-szoclAm, INc. cl3(f::2 fgTrsBuRGR AVE, curs ZO RAN coo cucAmomGA, cA • 011730 ,PpoNEE: : C10q) x-81 -&322 RE COF-2010L)"RAWINJIG THESE RECORD DRAWINGF HAI 117 BEEN PREPARED, IN PART, ON THE BASIS OF wF' •.""''!ON COMPILED AND FURNISHED BY OTHERS. THE =NGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE DOCUMENTS AS A RESULT THEREOF. CIVIL ENG/NEER CONTACT PERSON: MADOLE & ASSOCIATES DAVID JENKINS (909) 9J7-9151 EXT 119 REV. REVISION DESCRIP RON DA T F ENGR. CITY DA TF SHOULD CONS TRUC TION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WI THIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO 4 -sill ill CONFORMANCE WITH CONDITIONS AND S TANDA RDS IN EFFECT. 6 OLD HIGHLAND AVENUE) L SO. HIGHLAND AVENUE Q SITE a Q Q Q 2 WALNU T A VENUE VICINITY MAP N. T. S. PRIVATE ENGINEER'S NOT/CE TO CONTRA C TORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, • INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, • THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT /S THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS. CONTRACTOR SHALL COMPLY WITH ALL N. P. D. E. S REQUIREMENTS. CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES, UTILITY BOXES AND LIDS, ETC. CONS TRUC T/ON NO TES: (D-_ CONSTRUCT CATCH BASIN PER S.P.P.W.C. SID. PLAN 300-2, DETAIL ON SHr 3. _ O2 -CONSTRUCT 24" R.C.P. STORM DRAIN (D -LOAD ON PLAN). Q- CONSTRUCT P.C.C. COLLAR PER S.P.P.W.C. STD. PLAN 380-3, DETAIL ON SN7. J. 4� CONSTRUCT J.S. PER S.P.P.W.C. STD. PLAN 331-2, DETAIL ON SHT J. o- CONSTRUCT PIPE CLOSURE PER SAN BERNARDINO COUNT)' FLOOD CONTROL DISTRICT STD. PLAN S.P. 176A, DETAIL HEREON. 6o-- REPAIR TRENCH PER CITY STD. 131. CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA ATTN. BRIAN WREN 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-6632 SO. CALIFORNIA GAS COMPANY ATTN. JACK JARVIS 16231 VALLEY BLVD. FONTANA, CA. 92335 (909) 428-8411 EMERGENCIES. (800) 427-2200 SO. CALIFORNIA EDISON COMPANY 7951 REDWOOD AVE. FONTANA, CA. 92JJ5 (909) 820-5598 - UNDERGROUND (909) 875-5100 - TRANSMISSIONS (9093 357-6233 - DISTRIBUTION CRAWFORD CANYON MUTUAL WATER CO. ATTN. BASIL J. FABRIZ10 (909) 463-9580 WEST SAN BERNARDINO WATER UNDERGROUND SERVICE ALERT (800) 422-4133 SBC A TTN .• JAMES ZIELINSKI 1265 N. VAN BUREN STREET SUI TE 180 ANAHEIM, CA 92807 (714) 666-5415 METROPOLITAN WATER DISTRICT WA TER SYSTEM OPERA 77ON GROUP A TTN: JOE MIRONE (909) 776-2664 BENCH MARK.• IS B. CO. SPSN-00534 1 BASIS OF BEARINGS. ADELPHIA (CABLE TV) ATTN: JACK HA YES 1205 DUPONT AVENUE ONTARIO, CA. 91761 (909) 390-4738 VERIZON ATTN. STEVE HOCK 1400 E. PHILLIPS BLVD. POMONA, CA. 91766 (909) 469-6327 FONTANA WATER COMPANY ATTN: MICHAEL J. McGRAW 8440 NUEVO AVENUE FONTANA, CA 92335 TEL: (909) 822-2201 FAX: (909) 823-5046 WEST VALLEY WATER DISTRICT ATTN. LON TSAI 855 W. BASELINE ROAD RIALTO, CA 92377 (909) 875-1804 SAN GABRIEL VALLEY MUNICIPAL WATER DISTRICT ATTN. DAVE JOHNSON 549 EAST SIERRA MADRE AVENUE AZUSA, CA. 91702-1299 P.O. BOX 1299 (909) 969-7911 QUANT/TY.- 1 EA. 74 LF. 1 EA. 1 EA. 1 EA. 265 SF THE BASIS OF BEARINGS MR THIS MAP /S THE NEAR N/W CORNER HIGHLAND d; SAN SEVNINE NORTH LINE OF THE NORTHEAST QUARTER OF AVES, 343 FT. N OF HIGHLAND, 0.2 MI. W OF SECTION A 70ONSHIP 1 NORTH, RANGE 6 WEST, SAN SEVA/N& IN S CONC. BASE OF SCE TOM SAN BERNARDINO MER/DIW, SHOWN AS ?189* 39' Ift 265 ML W ALONG HOUND AVE FROM 56' r ON TRACT ACIP No. 1607 BLED /N BOOK SIERRA AVE 281, PAGES 69 THROUGH 72, INLYUS/VS OF MAPS, ELEVA 770N: 1,428.6090 RECOMS OF SAN BERNMlVO COUNTY. Prep are Under Th e Sup ervision Of : CITY OF FONTANA, CALIFORNIA STORM DRAIN IMPROVEMENT PLAN MADOLE O L E 1455 AUTO CENTER DRIVE _ SUITE 200 DRAWN BY SAN SEVAINE ROAD SCALE.• w No. 36637 CONTARIO, CA 91761 DM AS SHOWN 909.937.9151 TITLE SHEET Exp: 06-30-08 Engineering Communities for Life www.madoleinc.com DESIGNED BY DATE• s�q c i \ EF TRA C O 17824 JUNE, 2006 TFOFCAL\FOS Date :3 CHECKED B : APP OVED DRAWING NO, 6 EXP. 64o -dg. � RCE 36DJ GH .. � 419 WENDELL L. I WA TSURU'(- A / l TY ENG R R. C. E. 51152 DATE 3 R 4 Z Z Z W Q_ Z O v! Os O� V_ Z 7 JA142-1990\storm\SD01.dwa. 3/15/2007 9:48:12 AM. Dawr